Jaga BRIZA 26 HIGH PERFORMANCE User manual

BRIZA 26
HIGH PERFORMANCE
MANUAL

TABLE OF CONTENTS
.USED SYMBOLS.............................................................................................................
.WARNINGS AND SAFETY ............................................................................................
.PACKAGING AND COMPONENTS.............................................................................
.INSTALLATION ................................................................................................................
..ACOUSTIC INSULATION..............................................................................................................................
.GENERAL INFORMATION ............................................................................................
..OPERATIONAL LIMITS:.................................................................................................................................
..ELECTRICAL CONNECTION GENERAL.................................................................................................
..OPERATING LIMITS.......................................................................................................................................
.WALL MOUNTED MODEL ............................................................................................
..OVERVIEW.......................................................................................................................................................
..CONFIGURATION..........................................................................................................................................
..DIMENSIONS .................................................................................................................................................
.INSTALLATION ..............................................................................................................
.CEILINGMOUNTEDMODEL.....................................................................................
..OVERVIEW....................................................................................................................................................
..CONFIGURATION.......................................................................................................................................
..DIMENSIONS ...............................................................................................................................................
..INSTALLATION ............................................................................................................................................
.INITIAL START ...............................................................................................................
.MAINTENANCE ..........................................................................................................
..SPECIAL NOTE..........................................................................................................................................
..ROUTINE MAINTENANCE .....................................................................................................................
..ELECTRICAL CIRCUIT.............................................................................................................................
.WARRANTY .................................................................................................................
.DISSASSEMBLY INSTRUCTIONS...........................................................................
.REFERENCE STANDARDS.......................................................................................
DECLARATION OF CONFORMITY
JAGA N.V. - Verbindingslaan 16 - B 3590, declares under its sole responsibility that the
product to which this declaration relates:
is in conformity with the following standards or documents provided that these are used in
accordance with our instructions:
CEO JAGA N.V.
Jan Kriekels
BRIZA 12, BRIZA 22, BRIZA 26
NBN EN 603351 BASED ON EN 603351:2012 + A11:2014 +
A12:2017 + A13:2017 + A1:2019 + A2:2019 + A14:2019
NBN EN 60335280 BASED ON EN 60335280:2003 + A1:2004 + A2:2009
- Low Voltage 2014/35/EC
- EMC 2014/30/EC
- Machinery 2006/42/EC
- RoHS 2011/65/EU
Following the provision of Directives as amended:
08/02/2022
2 JAGA CANADA | BRIZA | MANUEL | .. | V.

Important info
The unit must be installed by a certified installer in accordance with the installati-
on instructions and the local building codes. Please follow this instruction manual
and file it somewhere safe! The unit must always be accessible for maintenance
and inspection.
The warranty is void when:
- the installation, maintenance or operation instructions in this manual are not respected.
- modifications have been made to the product,before, during or after product installation.
- maintenance has been carried out by unauthorized people.
- maintenance has been carried out by someone other thanJaga.
- access to the unit has been restricted due to on-site conditions.
- the initial start-up has been carried out before a general cleaning of both the fan and the coil.
1. USED SYMBOLS
the DANGER sign warns the operator and maintenance staff about risks that may cause
death, physical injury or illnesses of any kind.
DANGER: ELECTRICAL HAZARD
DANGER: SHARP EDGES
DANGER: HOT SURFACES
DANGER: MOVING PARTS
ATTENTION: IMPORTANT WARNING
the ENVIROMENTAL SAFEGUARD sign provides instructions on how to use the unit in an
ECO-friendly manner.
EN
3
JAGA CANADA | BRIZA | MANUEL | .. | V.

2. WARNINGS AND SAFETY
Handling guidelines:
The unit must be handled with care in order to avoid damage to the unit’s interior and exterior parts.
The unit might have sharp edges; use gloves during installation/adjustment.
All the operations listed below must be carried out in accordance with local health and safety regula-
tions.
Storage conditions:
Up to four packaged units may be stacked on top of each other. All units must be stored in a dry area.
Technical spaces and positioning:
Incorrect installation of the unit may cause noise and vibrations issues.
3. PACKAGING AND COMPONENTS
Follow these instructions when removing the packaging:
–check for any visible damage
–open the packaging
–check if the manual is in the package
–remove the packaging material and put it in the appropriate collection point or recycling facility, in
compliance with the local regulations.
Dispose of the packaging materials in compliance with the national or local regulations.
Do not leave the packaging within reach of children.
4. INSTALLATION
–installation must be carried out by certified technicians. Incorrect installation could cause product
failure, a reduced performance or an increased noise level.
–the unit must be installed in accordance with the local building codes.
–Always use personal protective equipment.
–the unit must remain accessible for inspection and maintenance, the trench must be removable at
all times.
..ACOUSTIC INSULATION
Sound absorption
Sound is reflected by hard materials. Soft, porous materials are best suited for sound absorption. A
combination of different materials can reduce the reflection of sound.
Contact noise insulation
Sound travels very easily through hard materials. Soft rubber material can be used to reduce contact
noise. The effect of this insulation strongly depends on:
–installation method: make sure that vibrations cannot be transferred between different elements,
e.g. between the built-in heaters and other metallic parts, through pipes, along air ducts etc.
–installation of acoustic insulation in hollow acoustic spaces. Avoid cavities between insulation and
pipes.
4 JAGA CANADA | BRIZA | MANUEL | .. | V.

5. GENERAL INFORMATION
DANGER!
The unit is not intended for industrial applications.
Do not insert objects into the supply and return air openings.
IMPORTANT!
–the unit will only function correctly if the installation and operation manual is strictly followed.
–all clearances indicated in the manual must be respected in order to guarantee performance, and to
allow installation and maintenance.
–in case valve packages are to be installed, make sure that there is enough room left.
–periodic access to the unit is required for inspection, maintenance and repairs.
–pay attention to the signs and symbols indicated on the fan coil units.
Unit identification:
The serial number is tagged on unit’s right side (on the left if the connections are on the unit’s right
side).
Information regarding unintended use:
The unit has been designed to function as a fan coil for both heating and cooling applications; any
other use is strictly forbidden. Installing the unit in an explosive environment is prohibited.
Decommissioning:
When the unit is not used for long periods of time, it must be disconnected from the mains electrical
connection.
If the unit is not used during the winter period, the water in the system may freeze. A suitable quantity
of anti-freeze liquid should be mixed with the water.
Mixing the water with glycol modifies the unit’s performance. Pay attention to the safety
instructions on the packaging regarding glycol.
Restart after prolonged shutdown:
Before restarting:
–clean or replace the stainless steel fan guard.
–clean the coil.
–clean or unclog the condensate drain.
–bleed the air from the hydronic system.
–it is advisable to run the unit at maximum speed and to check for abnormalities.
..OPERATIONAL LIMITS:
An installation that does not meet the specified operational limits releases Jaga NV from all liability
with respect to damage to objects or people.
–mains voltage: V - ph - Hz
–maximum water inlet temperature: °C - °F
–maximum exchanger pressure: bar - PSI
–supply voltage: V ± %
EN
5
JAGA CANADA | BRIZA | MANUEL | .. | V.

..ELECTRICAL CONNECTION GENERAL
IMPORTANT!
The electrical connection of the unit must be carried out by qualified personnel, in compliance with
the regulations applicable in the country where the unit is installed. Non-conforming electrical con-
nections releases Jaga N.V. from liability concerning damage to objects and persons.
DANGER!
–Always install a general automatic switch in a protected area near the unit, which has a characteris-
tic delayed curve, sufficient capacity and breaking power. There must be a minimum distance of
mm between the contacts.
–Earth connection is compulsory by law to ensure user safety while the unit is in use.
–Check that the voltage and the frequency of the electrical system correspond to V (±%) single
phase at Hz; that the available installed power is sufficient for running the equipment and that
the supply cables are of adequate section for the maximum current required.
–Make sure the electrical supply system complies with current National safety regulations.
–The connections must be implemented in accordance with the diagrams supplied with the unit.
Use an HRN-F type, flexible, double insulated, bipolar + earth cable with a . mm section to
connect the unit to the mains.
–If the unit is mounted on a metal surface, the earth connection must be installed in compliance with
local regulations. The earth conductor must be longer than the other conductors so that it is the last
one to release in the event the connection comes loose.
0-10V
Speed control input
GND
LN
NEUTRAL (N)
L (HOT)
Red / Not used
Blue
Blue
Yellow / Green
Black or Brown
Yellow
White / Not used
Blower
Motor
As reference: controlled by external
thermostat (not included)
CIRCUIT BREAKER OR FUSE
MAX. AMPS
To be provided by the installer. The circuit breaker
or fuse need to provide full disconnection from the
supply mains in all poles under overvoltage category III
accordance with the wiring rules.
6 JAGA CANADA | BRIZA | MANUEL | .. | V.

..OPERATING LIMITS
If the appliance is supplied with chilled water, the condensation forming on the heat exchanger will
be drained via the condensation drain connection.
At very low chilled water temperature and very high humidity, condensation may form on compo-
nents other than the heat exchanger. This is not collected in the condensation drain, but might drip
from under the appliance.
To avoid this, a minimum permitted water temperature must be taken into account in function of the
relative humidity and temperature of the ambient air.
5.3.1. PERMITTED MINIMUM WATER TEMPERATURE (°C)
AMBIENT TEMPERATURE / DRY BULB TEMPERATURE °F
. °F . °F °F . °F . °F . °C
RH %
% . °F . °F . °F . °F . °F . °F
% . °F . °F . °F . °F . °F . °F
% . °F . °F . °F . °F . °F . °F
% . °F . °F °F . °F . °F °F
% . °F °F . °F . °F °F /
% °F . °F . °F °F //
% . °F . °F °F ///
Permitted minimum water temperature
EN
7
JAGA CANADA | BRIZA | MANUEL | .. | V.

6. WALL MOUNTED MODEL
..OVERVIEW
Casing made from electrolytic galvanized steel
Dynamic Low H2O hydrophilic coil
Hydraulic connection
(2-pipe 3/4" NPT)
Hydraulic connection
(4-pipe 1/2" NPT
Condensate tray with 3/4"
drain connection 1" filter rack (2" or 4" rack
upon request)
Electrical connection
Centrifugal fan(s) with
double inlet
..CONFIGURATION
BABW/BT BABW/BF BABW/FT BABW/FF
SUCTION the bottom of the unit the bottom of the unit the front of the unit the front of the unit
AIR OUTLET the top of the unit the front of the unit the top of the unit the front of the unit
8 JAGA CANADA | BRIZA | MANUEL | .. | V.

T T T
L / / /
HEIGHT / / /
WIDTH / / /
LENGTH / / /
A / / /
B / / /
..DIMENSIONS
L
22 /
13 /*
3 /*
10 /
L+2 /
A
B
B - 11 /*
B - 2 /*
B
A
3 /
11 /
2 /
3 /
L- /*
/
11 /
25 /
1 /*
15 /*
13 /*
5 /*
Min.
3 /1 /
3 /
1 /
Dimensions in Inches
EN
9
JAGA CANADA | BRIZA | MANUEL | .. | V.

6.3.1. Installation dimensions
L
≥5 /≥7 /
≥9 / ≥7 /
≥5 /
≥5 /
≥5 /
≥5 /
≥9 /
≥5 /
≥10 /
≥12 /
≥12 /
≥10 /
≥7 / ≥5 /
≥6 /
≥6 /
Dimensions in Inches
10 JAGA CANADA | BRIZA | MANUEL | .. | V.

Stop hydraulic
connection during
assembly
208V / 60Hz 0-10V
Speed control input
GND
LN
Red
Blue
Blue
Yellow / Green
Black or Brown
Yellow
White
NOT USED
4 /
1 /
/
2 /
5 /
20 /
15 /
9 /
7 /
2 /
19 /
12 /
6.3.2. Hydraulic & electrical connection
Dimensions in Inches
7. INSTALLATION
With casing: Mark and drill the mounting holes for the back plate and the device (-).
Without casing: Mark and drill the mounting holes for the the device.
The type of wall determines which type of screw or plug must be used.
Make sure that the wall is level and has sufficient loadbearing capacity!
WITH CASING WITHOUT CASING
1
2
6
3
5
7
4
8
EN
11
JAGA CANADA | BRIZA | MANUEL | .. | V.

. Insert the screws of the back plate (-) and let them stick out cm.[]
.Install the back plate.
.Tighten the screws. []
1 2
WITH CASING
.Place the screws of the device(-) and let them stick out cm. []
.Place the device in the correct position.
.Tighten the screws. []
12
Connect the device electrically.
208V / 60Hz 0-10V
Speed control input
GND
LN
Red
Blue
Blue
Yellow / Green
Black or Brown
Yellow
White
NOT USED
12 JAGA CANADA | BRIZA | MANUEL | .. | V.

Connect the device to the hydraulic system by using the specified inlet/ outlet connections. Make sure that the connections are
air tight, use a sealant for this. The coil is equipped with a de-aerater.
If the unit is used for cooling, the hydraulic pipes must be insulated.
When using devices for cooling: iron couplings prohibited.
Use a back-off wrench when fastening the
hydronic connections!
Remove black plug at hydraulic
connection.
IN
OUT
Install the condensate drain. The device must be hung with a downward slant towards the condensate drain, to ensure that the
condensation water is drained quickly. (cm/m)
The condensate drain system must be set up with an adequate p-trap in order to prevent the infiltration of odours. Always install
a plug for cleaning in the lower part of the p-trap in order to allow quick disassembly.Pour water into the condensate collection
pan and check if the liquid is drained properly. Otherwise, check the inclination and look for possible blockages.
If the condensation drain pan is not used, the drain pipe must be connected directly to the condensation trap. In this
case, the hydraulic pipes and the valves used for cooling water must be insulated against condensation
Position the drain pipes without mechanical stress on the drain connection of the unit.
EN
13
JAGA CANADA | BRIZA | MANUEL | .. | V.

Install the support bolts in the back plate.Let the bolts stick
out cm.
Install the grille. Put the screws in the mounting holes.
Ideally, the air is blown towards the wall.
Mount the casing. Make sure the mounting holes are in line
with the support bolts. []
Secure the casing by tightening the stay bolts.[]
WITH CASING
MIN. CM
WITH CASING WITH CASING 1
2
14 JAGA CANADA | BRIZA | MANUEL | .. | V.

8. CEILING-MOUNTED-MODEL
..OVERVIEW
..CONFIGURATION
BABW/BT BABW/FT
SUCTION the bottom of the unit the front of the unit
AIR OUTLET the top of the unit the top of the unit
Dynamic Low H2O hydrophilic coil
Hydraulic connection
(2-pipe 3/4" NPT)
Condensate pump
(BY OTHERS)
Hydraulic connection
(4-pipe 1/2" NPT)
Condensate tray with 3/4"
drain connection
1" filter rack (2" or 4" rack
upon request)
Electrical connection
Centrifugal fan(s) with
double inlet
EN
15
JAGA CANADA | BRIZA | MANUEL | .. | V.

..DIMENSIONS
T T T
HEIGHT / / /
WIDTH / / /
LENGTH / / /
22 /
11 / 10 /
L + 3 /
L1 /
L- /*
13 /*
1 /
*
Dimensions in Inches
8.3.1. Installation dimensions
max. 118 /max. 118 /
≥ 12 / ≥ 12 /
5 /5 /
≥6 / ≥6 /
5 /5 /
Dimensions in Inches
16 JAGA CANADA | BRIZA | MANUEL | .. | V.

8.3.2. Hydraulic & electrical connection
208V / 60Hz
0-10V
Speed control input
GND
LN
Red
Blue
Blue
Yellow / Green
Black or Brown
Yellow
White
NOT USED
/
5 /
20 /
8 /
15 /
9 /
10 /
7 /
2 /
19 /
12 /
11 /
..INSTALLATION
Mark and drill the mounting holes for the the device.
The type of wall determines which type of screw or plug must
be used.
Make sure that the wall is level and has sufficient loadbearing
capacity!
.Place the screws of the device(-) and let them stick out
cm. Use a washer between screw head and the appliance. []
.Place the device in the correct position.
.Tighten the screws. []
Threaded rods: mount the unit on the threaded rods. Use a
washer between screw head and the appliance.
The installer should provide sound dampening material.
1
2
Dimensions in Inches
Stop hydraulic
connection during
assembly EN
17
JAGA CANADA | BRIZA | MANUEL | .. | V.

Connect the device to the hydraulic system by using the specified inlet/ outlet connections. Make sure that the connections are
air tight, use a sealant for this. The coil is equipped with a de-aerater.
If the unit is used for cooling, the hydraulic pipes must be insulated.
When using devices for cooling: iron couplings prohibited.
Use a back-off wrench when faste-
ning the hydronic connections!
Remove black plug at hydraulic
connection.
IN
OUT
Connect the condensate pump.
Connect the device electrically.
208V / 60Hz 0-10V
Speed control input
GND
LN
Red
Blue
Blue
Yellow / Green
Black or Brown
Yellow
White
NOT USED
18 JAGA CANADA | BRIZA | MANUEL | .. | V.

9. INITIAL START
IMPORTANT!
Start-up and Commissioning of the fancoil must be carried out by skilled staff, qualified to work on
this type of product.
DANGER!
Before start-up, make sure the installation has been carried out in compliance with in this manual.
Before start-up the fancoil unit, check if:
. the unit is positioned correctly
. the supply and return pipes are properly connected and insulated
. the pipes are clean and air is removed
. the inclination of the unit towards the drain and the p-trap are correct
. the coils are clean
. the wiring connections are correct and properly tightened
. the supply voltage is correct
. the electric power consumption is correct and does not exceed the maximum value indicated in
the catalog
10. MAINTENANCE
DANGER!
–maintenance must be carried out by qualified technicians.
–do not insert sharp objects into the supply and return grilles
the unit has sharp edges; use gloves during maintenance!
DANGER!
Always use the main disconnect switch to isolate the unit from the mains before carrying out any
maintenance or inspection work. Make sure that no one accidentally turns on the power to the unit;
lock the master switch in the off position.
..SPECIAL NOTE
Maintenance and cleaning of the stainless steel protection grille:
a dirty grille obstructs the air flow, so clean the grille at regular intervals, depending on the room’s
purpose and how it’s used. The grille should never be disassembled for maintenance and can be
easily cleaned by using a vacuum cleaner.
Cleaning the unit:
always disconnect the power supply before servicing the fan!!
–cleaning at regular intervals is important, depending on the room’s purpose and how it’s used
–clean with a vacuum cleaner or air compressor. Do not use solvent- or detergent based products.
..ROUTINE MAINTENANCE
Every 6 months: Check the condition of the coil and condensate drain:
If necessary:
–remove any dirt from the coil surface
–remove dust using an air compressor
–wash with water and brush gently
–dry by using compressed air
–keep the condensate drain free from any obstructions that may prevent normal water flow
EN
19
JAGA CANADA | BRIZA | MANUEL | .. | V.

Bleed air from the system.
. start the circulation pump and open the supply valve for a few minutes.
. stop the circulation pump.
. loosen the vent screw on the inlet collector and bleed the air.
. repeat steps to until there is no more air escaping the system
..ELECTRICAL CIRCUIT
The following steps are recommended to perform maintenance on the electrical circuit:
–check the unit’s power consumption using a clip-on meter and compare the reading with the values
shown in the documentation;
–inspect the electrical contacts for corrosion and loose wires.
11. WARRANTY
The fan coil unit is intended strictly for conditioning the indoor climate. Any unintended use is
strictly forbidden and voids all warranty on the product. Installation, maintenance and operation of
the unit is only allowed for authorized staff.
Please follow these instructions carefully
The warranty is void when:
–the installation procedure has not been followed,
–the fan coil has not been periodically cleaned,
–the unit has been used in an improper or irresponsible manner,
–repairs have been carried out by others than Jaga,
–product modifications have been carried out by others, before or after the installation,
–the product is not accessible for cleaning or maintenance.
If you have any questions or complaints, please contact your supplier or installer. The copyright of
these instructions is the property of Jaga.
12. DISSASSEMBLY INSTRUCTIONS
SAFEGUARD THE ENVIROMENT
Jaga cares about protecting the environment.
When the unit is dismantled it is important to strictly follow these procedures:
–the unit must be dismantled by a firm that is authorized to dispose of scrap machinery/products
The unit as a whole is composed of secondary raw materials and the following conditions must be
met:
–if the unit contains antifreeze, then dispose of the antifreeze as indicated in the glycol supplier’s
instructions.
–the electronic components are considered special waste, and must be recycled as such
–the pipe insulation and the sound-absorbing lining must be removed and processed as urban waste
Please follow and file these instructions!
20 JAGA CANADA | BRIZA | MANUEL | .. | V.
Table of contents
Other Jaga Fan manuals
Popular Fan manuals by other brands

LUCCI Air
LUCCI Air FIJIAN II Series manual

SLE
SLE SLE5000 Model J user manual

cecotec
cecotec ENERGYSILENCE 2000 COOL TOWER SMART instruction manual

Omega Altise
Omega Altise OAELITEB Operation, maintenance and safety instructions

Airwood
Airwood Matchables Wood Vent installation instructions

UBERHAUS DESIGN
UBERHAUS DESIGN FS40A-U2 owner's manual