Jaspi Inverter Nordic 8 User guide

Installer manual
LEK
JÄSPI Inverter Nordic
8, 12, 16, 20
Air/water heat pump
IHB EN 2214-2
531786


Table of Contents
41 Important information
4Safety information
4Symbols
4Marking
5Serial number
6Inspection of the installation
7Indoor module
7Control module
82 Delivery and handling
8Transport
9Assembly
11Compressor heater
11Condensation
12Supplied components
13Removing the side panel and top panel
143 The heat pump design
14General
18Distribution box
19Sensor placement
204 Pipe connections
20General
20Symbol key
20Pipe coupling heating medium circuit
225 Electrical connections
22General
22Accessibility, electrical connection
23Connections
286 Commissioning and adjusting
28Preparations
28Balance temperature
28Filling and venting
28Start-up and inspection
28Post adjustment and venting
29Adjustment, charge flow
307 Control
30General
30LED status
30Master control
31Control conditions
32Control - Heat pump EB101
358 Service
35Temperature sensor data
369 Disturbances in comfort
36Troubleshooting
37Alarm list
4010 Accessories
4111 Technical data
41Dimensions
42Sound levels
43Technical specifications
51Energy labelling
56Electrical circuit diagram
64Item register
67Contact information
3Table of Contents |JÄSPI Inverter Nordic

Safety information
This manual describes installation and service procedures
for implementation by specialists.
The manual must be left with the customer.
This appliance can be used by children
aged from 8 years and above and per-
sons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning use
of the appliance in a safe way and under-
stand the hazards involved. Children shall
not play with the appliance. Cleaning
and user maintenance shall not be made
by children without supervision.
This is an original manual. It may not be
translated without the approval of
Kaukora.
Rights to make any design or technical
modifications are reserved.
Electrical installation and wiring must be
carried out in accordance with national
provisions.
JÄSPI Inverter Nordic must be installed via
an isolator switch. The cable area has to be
dimensioned based on the fuse rating used.
If the supply cable is damaged, only
Kaukora, its service representative or similar
authorised person may replace it to prevent
any danger and damage.
Symbols
Explanation of symbols that may be present in this
manual.
NOTE
This symbol indicates danger to person or ma-
chine.
Caution
This symbol indicates important information
about what you should consider when in-
stalling or servicing the installation.
TIP
This symbol indicates tips on how to facilitate
using the product.
Marking
Explanation of symbols that may be present on the
product’s label(s).
Danger to person or machine.
!
Read the User Manual.
Disconnect the voltage supply before starting
work.
Dangerous voltage.
JÄSPI Inverter NordicChapter 1 | Important information4
1 Important information

Serial number
The serial number can be found at the top left on the
rear cover and at the bottom on the side.
LEK
Data
Serie.nr.
Art.nr.711453
OUT
IN
Caution
You need the product's (14 digit) serial number
for servicing and support.
5Chapter 1 | Important informationJÄSPI Inverter Nordic

Inspection of the installation
Current regulations require the heating installation to be inspected before it is commissioned. The inspection must
be carried out by a suitably qualified person. Fill in the page for information about installation data in the User
manual.
DateSignatureNotesDescription
✔
Heating medium (see section "Pipe connec-
tions")
System flushed
System vented
Particle filter
Shut-off and drain valve
Charge flow set
Electricity (see section "Electrical connections")
Fuses property
Safety breaker
Earth circuit-breaker
Heating cable type/effect
Fuse size, heating cable (F3)
Communication cable connected
JÄSPI Inverter Nordic addressed (only
when cascade connection)
Connections
Main voltage
Phase voltage
Miscellaneous
Condensation water pipe
Insulation condensation water pipe,
thickness (if KVR 10 is not used)
NOTE
Check the connections, main voltage and phase voltage before the machine is started, to prevent damage
to the heat pump electronics.
JÄSPI Inverter NordicChapter 1 | Important information6

Indoor module
JÄSPI Tehowatti Air
Stainless Steel, 3 x 400 V
LVI Code 505 85 28
Control module
JÄSPI MCU40
Control module
LVI Code 526 01 53
7Chapter 1 | Important informationJÄSPI Inverter Nordic

Transport
JÄSPI Inverter Nordic must be transported and stored
vertically.
NOTE
Ensure that the heat pump cannot fall over
during transport.
Check that the heat pump has not been damaged during
transport.
Lift from the street to the set up location
If the base allows, the simplest thing is to use a pallet
truck to move the JÄSPI Inverter Nordic to the set up
location.
NOTE
The centre of gravity is offset to one side (see
print on the packaging).
LEK
C:a 180 kg
Approx. 180 kg
If JÄSPI Inverter Nordic needs to be transported across
soft ground, such as a lawn, we recommend using a
crane truck that can lift it to the installation location.
When JÄSPI Inverter Nordic is lifted with a crane, the
packaging must be untouched.
If a crane vehicle cannot be used the JÄSPI Inverter Nor-
dic can be transported on an extended sack truck.
JÄSPI Inverter Nordic must be taken from its heaviest
side and two people are required to lift JÄSPI Inverter Nor-
dic.
Lift from the pallet to final positioning
Before lifting remove the packaging and the securing
strap to the pallet.
Place lifting straps around each machine foot. Lifting
from the pallet to the base requires four persons, one
for each lifting strap.
Scrapping
When scrapping, the product is removed in reverse order.
Lift by the bottom panel instead of a pallet!
JÄSPI Inverter NordicChapter 2 | Delivery and handling8
2 Delivery and handling

Assembly
■Place JÄSPI Inverter Nordic outdoors on a solid level
base that can take the weight, preferably a concrete
foundation. If concrete slabs are used they must rest
on asphalt or shingle.
■The lower edge of the evaporator must not be lower
than the level of the average local snow depth. The
base should be at least 70 mm tall.
■JÄSPI Inverter Nordic should not be positioned next
to noise sensitive walls, for example, next to a bed-
room.
■Also ensure that the placement does not inconveni-
ence the neighbours.
■JÄSPI Inverter Nordic must not be placed so that recir-
culation of the outdoor air is possible. Recirculation
entails reduced power and impaired efficiency.
■The evaporator must be sheltered from direct wind / ,
which negatively affects the defrosting function. Place
JÄSPI Inverter Nordic protected from wind / against
the evaporator.
■A small amount of water may drip from the drainage
hole under JÄSPI Inverter Nordic. Make sure that this
water can run away by selecting a suitable material
underneath JÄSPI Inverter Nordic (see section "Con-
densation").
■Care must be exercised so that the heat pump is not
scratched during installation.
LEK
F2120
min 300 mm
LEK
F2120
LEK
min
70 mm
Do not place JÄSPI Inverter Nordic directly on the lawn
or other non solid surface.
If there is a risk of snow slip from roof, a protective roof
or cover must be erected to protect the heat pump, pipes
and wiring.
9Chapter 2 | Delivery and handlingJÄSPI Inverter Nordic

Installation area
The distance between JÄSPI Inverter Nordic and the house wall must be at least 350 mm, but not more than 500 mm
in locations that are exposed to the wind. The free space above JÄSPI Inverter Nordic must be at least 1,000 mm.
The free space in front must be at least 1,000 mm for any future servicing.
350 mm
Fritt utrymme bakom
Fritt utrymme framför
dock 1000 mm för ev. framtida service
Min. avstånd
vid användning
av flera F2300
600 mm
1000 mm
400 mm
Minimalt
fritt utrymme
600mm
Minimalt
fritt utrymme
Minimum free
space Minimum free space
Minimum distance during use
of several JÄSPIInverterNordic
600 mm
600 mm
At least 1,000
mm
Free space behind*
350 – 500 mm
400 mm
Free space in front for any future servicing
* The space behind must not exceed 500 mm in locations that are exposed to the wind.
JÄSPI Inverter NordicChapter 2 | Delivery and handling10

Compressor heater
JÄSPI Inverter Nordic is equipped with two compressor
heaters that heat the compressor before start-up and
when the compressor is cold.
The compressor heater (EB10) must have been active for
at least 3 hours before compressor operation can be
initiated. This is done by connecting control voltage.
JÄSPI Inverter Nordic permits compressor start after the
compressor has been warmed up. This can take up to 3
hours.
NOTE
The compressor heater must have been active
for approx. 3 hours before the first start, see
section “Start-up and inspection”.
Condensation
The condensate drain pan collects and leads away the
condensation water.
NOTE
It is important to the heat pump function that
condensation water is led away and that the
drain for the condensation water run off is not
positioned so that it can cause damage to the
house.
Condensation run-off should be checked regu-
larly, especially during the autumn. Clean if
necessary.
■The condensation water (up to 50 litres/24 hrs) that
collects in the trough should be routed away by a pipe
to an appropriate drain, it is recommended that the
shortest outdoor stretch possible is used.
■The section of the pipe that can be affected by frost
must be heated by the heating cable to prevent
freezing.
TIP
Pipe with heating cable for draining the
condensation water trough is not included.
To ensure the function, the accessory KVR 11
should be used.
■Route the pipe downward from the heat pump.
■The outlet of the condensation water pipe must be at
a depth that is frost free or alternatively indoors (with
reservation for local ordinances and regulations).
■Use a water trap for installations where air circulation
may occur in the condensation water pipe.
■The insulation must seal against the bottom of the
condensation water trough.
Drainage of condensation
Stone caisson
LEK
Frostfritt djup
F2120
Frost proof
depth
If the house has a cellar the stone caisson must be posi-
tioned so that condensation water does not affect the
house. Otherwise the stone caisson can be positioned
directly under the heat pump.
Drain indoors
Water seal
The condensation water is lead to an indoor drain (sub-
ject to local rules and regulations).
When routing pipes indoors, condensation water pipes
must be insulated against condensation.
Route the pipe downward from the heat pump.
The condensation water pipe must have a water seal to
prevent air circulation in the pipe.
11Chapter 2 | Delivery and handlingJÄSPI Inverter Nordic

Gutter drainage
LEK
F2120
Frostfritt
djup
Frost free
depth
Water seal
Route the pipe downward from the heat pump.
The condensation water pipe must have a water seal to
prevent air circulation in the pipe.
Caution
If none of the recommended alternatives is
used good lead off of condensation water must
be assured.
Supplied components
JÄSPI Inverter Nordic-8,
JÄSPI Inverter Nordic-12
Filterball (G1").
LEK
LEK
2 x flexible pipes (DN25, G1")
with 4 x gaskets.
JÄSPI Inverter Nordic-16,
JÄSPI Inverter Nordic-20
Filterball (G1 1/4").
LEK
LEK
2 x flexible pipes (DN25, G1
1/4") with 4 x gaskets.
JÄSPI Inverter NordicChapter 2 | Delivery and handling12

Removing the side panel and top panel
Unscrew the screws and lift off the top panel.
LEK
13Chapter 2 | Delivery and handlingJÄSPI Inverter Nordic

General
JÄSPI Inverter Nordic (1x230V)
LEK
GQ1
AA2
UB1
BT12
EP2
XL1
BT3
XL2
HS1
XL21
BT84
QN1
QN4
RM1
QN2
BP11
QN34
BT15
BT14 EB10
QA40 GQ10
BT17
RA1
BP9
BP1
BP2
BP8
XL20
BT81
HQ9
CA1
X6
JÄSPI Inverter NordicChapter 3 | The heat pump design14
3 The heat pump design

JÄSPI Inverter Nordic (3x400V)
LEK
GQ1
AA2
UB1
BT12
EP2
XL1
BT3
XL2
HS1
XL21
BT84
QN1
QN4
RM1
QN2
BP11
QN34
BT15
BT14 EB10
QA40 GQ10
BT17
RF2RA1
BP9
BP1
BP2
BP8
XL20
BT81
HQ9
PF1
15Chapter 3 | The heat pump designJÄSPI Inverter Nordic

LEK
Data
Serie.nr.
Art.nr.711453
OUT
IN
PZ4
BT16
PZ1
BT28
EP1
WM5
XL40
XL1
XL2
PZ3
PZ3
JÄSPI Inverter NordicChapter 3 | The heat pump design16

Pipe connections
Heating medium connection, supply (from
JÄSPI Inverter Nordic)
XL1
Heating medium connection, return (to
JÄSPI Inverter Nordic)
XL2
Service connection, high pressureXL20
Service connection, low pressureXL21
Connection, drain condensation water troughXL40
HVAC components
Condensation water troughWM5
Sensors etc.
High pressure pressostatBP1
Low pressure pressostatBP2
Low pressure transmitterBP8
High pressure sensorBP9
Pressure sensor, injectionBP11
Temperature sensor, returnBT3
Temperature sensor, condenser supply lineBT12
Temperature sensor, hot gasBT14
Temperature sensor, fluid pipeBT15
Temperature sensor, evaporatorBT16
Temperature sensor, suction gasBT17
Temperature sensor, ambientBT28
Temperature sensor, suction gas evaporatorBT84
Electrical components
Base cardAA2
Capacitor (1x230V)CA1
Compressor heaterEB10
FanGQ1
Signal lamp (LED 201)PF1
InverterQA40
Harmonic filter (3x400V)RA1
Choke (1x230V)RA1
EMC filter (3x400V)RF2
Terminal block (1x230V)X6
Cooling components
EvaporatorEP1
CondenserEP2
CompressorGQ10
Particle filterHQ9
Drying filterHS1
Expansion valveQN1
4-way valveQN2
Bypass valveQN4
Expansion valve, subcoolingQN34
Non-return valveRM1
Miscellaneous
Type platePZ1
Serial numberPZ3
Sign, pipe connectionsPZ4
Cable gland, incoming supplyUB1
Designations according to standard EN 81346-2.
17Chapter 3 | The heat pump designJÄSPI Inverter Nordic

Distribution box
LEK
AA2 FC1
X24 F4 F2 F1
S2
S1
X23
X22
X21
X28 X27 F3 X2 X1 X5
X9
S3
Electrical components
Base cardAA2
Terminal block, incoming supplyX1
Terminal block, compressor supplyX2
Terminal block, external control voltageX5
Terminal block, connection KVRX9
Terminal block, Compressor blocking,
Tariff
X21
Terminal block, communicationsX22
Terminal block, communicationsX23
Terminal block, fanX24
Terminal block, expansion valve QN1X27
Fuse, operating 230V~, 4AF1
Fuse, operating 230V~, 4AF2
Fuse for external heating cable, KVR, 250mAF3
Fuse, fan, 4AF4
Miniature circuit-breaker (Replaced with automat-
ic protection (FB1) when installing accessory
KVR 11.)
FC1
EMC filter for inverterRF2
DIP switch, addressing heat pump during multi
operation
S1
DIP switch, different optionsS2
Reset buttonS3
JÄSPI Inverter NordicChapter 3 | The heat pump design18

Sensor placement
Sensors
1
1
2 1 2 3 4 1 2 3 4
234 1234
BT28
BT3
BT12
BT16
BT14
BT15
BT17
BT81
BT84
BP8
BP8
BP11
BP9
BP11
BT3
BT28
BT16
BT12
BT14
BT15
BT17
BT81
BT84
BP8
BP9
BP9
BP11
Low pressure transmitterBP8
High pressure sensorBP9
Pressure sensor, injectionBP11
Temperature sensor, returnBT3
Temperature sensor, condenser supply lineBT12
Temperature sensor, hot gasBT14
Temperature sensor, fluid pipeBT15
Temperature sensor, evaporatorBT16
Temperature sensor, suction gasBT17
Temperature sensor, ambientBT28
Temperature sensor, injection, EVI compressorBT81
Temperature sensor, suction gas, evaporatorBT84
19Chapter 3 | The heat pump designJÄSPI Inverter Nordic

General
Pipe installation must be carried out in accordance with
current norms and directives.
The pipe dimension should not be less than the recom-
mended pipe diameter according to the table. However,
each system must be dimensioned individually to man-
age the recommended system flows.
Minimum system flows
The installation must be dimensioned to manage at least
the minimum defrosting flow at 100% pump operation,
see table.
Minimum
recommen-
ded pipe di-
mension
(mm)
Minimum
recommen-
ded pipe di-
mension
(DN)
Minimum
flow during
defrosting
(100%
pump
speed (l/s)
Air/water
heat pump
22200.27
Inverter Nord-
ic-8 (1x230V)
JÄSPI Inverter
Nordic-8
28250.35
Inverter Nord-
ic-12
(1x230V)
Inverter Nord-
ic-12
28250.38Inverter Nord-
ic-16
35320.48Inverter Nord-
ic-20
NOTE
An undersized system can result in damage to
the product and lead to malfunctions.
JÄSPI Inverter Nordic can only operate up to a return
temperature of about 55 °C and an outgoing temperat-
ure of about 65 °C from the heat pump.
JÄSPI Inverter Nordic is not equipped with shut-off valves
on the heating medium side, rather these must be in-
stalled to facilitate any future servicing. The return tem-
perature is limited by the return line sensor.
Water volumes
Depending on the size of your JÄSPI Inverter Nordic, an
available water volume is required to prevent short op-
erating times and to enable defrosting. For the optimum
operation of JÄSPI Inverter Nordic, a minimum available
water volume of 10 litres multiplied by the size number
is recommended. E.g. JÄSPI Inverter Nordic-12: 10 litres
x 12 = 120 litres. This applies individually to heating and
cooling systems.
NOTE
The pipe installation must be flushed out be-
fore the heat pump is connected so debris
cannot damage component parts.
Symbol key
MeaningSymbol
Shut-off valve
Tapping valve
Non-return valve
Circulation pump
Expansion vessel
Filterball
Pressure gauge
Safety valve
Trim valve
Reversing valve/shunt
Control module
Air/water heat pump
Radiator system
Domestic hot water
Water heater
Pipe coupling heating medium
circuit
Connecting the climate system
Install as follows:
■expansion vessel
■pressure gauge
■safety valves
■drain valve
For draining the heat pump during prolonged power
failures.
■non-return valve
Installations with only one heat pump: a non-return
valve is only required in those cases where the place-
ment of the products in relation to each other can
cause self-circulation.
Cascade installations: each heat pump must be fitted
with a non-return valve.
JÄSPI Inverter NordicChapter 4 | Pipe connections20
4 Pipe connections
Other manuals for Inverter Nordic 8
1
This manual suits for next models
3
Table of contents
Other Jaspi Heat Pump manuals