JENIX DS-103M User manual

DONG SAHN JENIX CO., LTD.
DS-103M
Height & Weight Auto Measuring Scale
English Manual

DS-103M
1
Contents
Structures
Assembling Procedures
How to use
Conversion of BMI, Fatness and Sound
Correction of weight error
BMI & FAT categories
Trouble shooing
Specifications

2
Touch-bar
(touch-rod)
Display panel
LED for conversion of BMI/FAT
Power switch
Rail
Bolt screws (M5x10: 6pcs)
Connector for power input
Base
Weighing board (feet board)
Balancing rubber screws (5pcs)
FAT lamp
BMI lamp
Conversion
Switch/button
Sound lamp
1. Structures

3
Step 1
Step 2
Step 3 Step 4
2. Assembling procedures
Assembling
Put together rail ⑤ & base⑧,
then, screw 6pcs bolts tight
as in the drawing.
Lay down the body on its side
and join 2 pairs of connectors in the bottom of the base,
according to the same colors and shapes.
2 connectors from the rail and the rest 2 from the base.
Make the scale horizontal by using 5pcs of
rubber screws ⑩. Please be sure if the bottom
of the scale contacted completely on the ground.
Balancing rubber screws
(5pcs)
Connect the power cord.
Correct pose
When stepping on a weighing board with
right pose, touch bar will be automatically
running down in 3 seconds.
Please pay attention not to make any movement
and not to lean against the rail while measuring.

FAT BMI
4
after 1 min.
3. How to use
1. Plug in the DC power adapter.
2. Push the power switch ④ for 2seconds.
(push for 2 seconds to turn off also)
3. Check if BMI lamp is on. (whenever pushing
the conversion button, the lamp of BMI or FAT
will be alternately changed)
conversion
button
pin
4. Stepping on a weighing board (feet shaped).
and do not make any movement.
It is a start signal.
5. Measuring is completed when touch bar touches
your head and goes up.
6. Check the measured values.
The numbers will disappear 1 minute later.
weight
height
BMI index
⊙ If you move out while measuring, touch bar will be back to its original position.
⊙ Please try not to make any movement while you are on the weighing board.
⊙ Measured values will disappear 1 minute later.
⊙ To use it again, step on the weighing board when there is no flickering in the display.
Caution

5
FAT BMI
FAT BMI “3sec.”
4. Conversion of BMI, FAT and Sound
BMI↔FAT
Sound↔No sound
Each time pushing the button,
BMI or FAT changes in return.
conversion button
pin
Each time pushing for 3 seconds the button,
Sound on or off changes in return.
conversion button
pin
sound on sound off

6
< uP >
conversion
button
< dN >
when the measured weight value is lower than real weight
1. Push the setting button for 10 seconds by using
a pin. Then, the touch-bar will go down and
stop at the level of the display.
2. Put a weight or an
object of which weight
you’ve already known.
(ex. 20kg)
3.
Push (or keep pushing) the
touching plate until exact weight
displayed.
4. Push the conversion button for 3 seconds
to finish correction.
This number is just for showing
changes and does not mean
setting value.
5. Correction of weight error
“push for 3 seconds”
when the measured weight is higher than real weight
1. Push the setting button for 10 seconds.
2. Put a weight or an object of which weight you’ve already known. (ex. 20kg)
3. Push the setting button one more time to select “DOWN” from “UP”
4. Push (or keep pushing) the touching plate until exact weight displayed
This number is just for showing
changes and does not mean
setting value.
5. Push the conversion button for 3 seconds
to finish correction.
“push for 3 seconds”
20kg

7
6. BMI & FAT categories
Weight (Kg)
Height (m )
²²² Adult ²²²
2
²²² Baby ²²²
BMI = 2
under 20: under weight
20 ~ 25: normal
25 ~ 30: over weight
over 30: obese
under 15: under grown
15 ~ 18: normal
18 ~ 20: over weight
over 20: obese
BMI Criterion
Weight
(Height-100)x0.9
※ This FATNESS formula is applied to only adults whose height
is over 130cm(4.26 ft). This cannot be applied to children and
adolescents.
Fatness =
under 100: under weight
100 ~ 110: normal
110 ~ 120: over weight
120 ~ 130: Light fat
130 ~ 140: Medium fat
over 140: High fat (obese)
Fatness Criterion
x100(%)
<Adult. Male>
※ As fatness rate for female doesn’t display in model DS-103M,
we recommend you to use only BMI mode at all times.
Body Mass Index
From Wikipedia, the free encyclopedia
The body mass index (BMI), or Quetelet index, is a statistical measure of body weight based on a person's
weight and height. Though it does not actually measure the percentage of body fat, it is used to estimate a
healthy body weight based on a person's height.
Due to its ease of measurement and calculation, it is the most widely used diagnostic tool to identify weight
problems within a population, usually whether individuals are underweight, overweight or obese.
It was invented between 1830 and 1850 by the Belgian polymath Adolphe Quetelet during the course of
developing "social physics. Body mass index is defined as the individual's body weight divided by the square
of his or her height.
Weight
(Height-105)x0.9
Fatness = x100(%)
<Adult. Female>

Touch-bar doesn’t move
check if the power is plugged in or connection is loose.
Turn off the power, pull down the touch-bar 5~10 cm downward, and turn on.
If the touch-bar in the top with no power but there is any sound, pull it down 5~10cm
downward and turn it on.
Touch-bar stopped
in the middle of
operation
If the touch-bar sopped in the middle (or bottom), turn if off and pull it up to
the top (or middle) of the rail, and then turn it on.
Height or weight
error or inaccuracy
Try to measure with a standard rod or thing to find if it’s error or not.
Check if the bottom of the scale is completely fixed on the ground.
Try “Correction of weight error” in the page 6.
Try “Zero setting” by yourself or request repairing service.
Others
If possible, please use this scale at one place. Frequent changes of location can
cause inaccuracy.
If you had to change location, please don’t forget to fix the scale completely on the ground.
Sometimes in case of problem in an adapter, it seems to work well but actually
causes malfunctioning.
Please do not pull or push the touch-bar forcibly by a hand while it is moving.
8
7. Trouble shooting
Touch-bar doesn’t move at all Make sure a power cord connection is loose or unplugged.
Make sure you stepped on weighing board while display flicking.
Please check the power switch is working well.
Touch-bar stopped in the
middle of moving
Turn the power off and on again.
Make sure nothing is on the weighing board area.
Height or weight values measured
are different. (accuracy problem)
After turning off and on, try measuring 5~10 times more.
Adjust level again.
Reset height or weight according to the page 6 (correction).
Others As it is sensitive system, please use in a fixed place, if possible.
This product is designed for free voltage (AC 100~220V).
Do not touch the power cord with wet hands.
(Electric shock can be caused)
As it is sensitive, please do not impact against the touch-bar.
Please use in a measurable range.
Please do not use when the scale is not yet ready (flickering)
Please be careful not to spill any liquid or something inflammable.
Plug out before cleaning and do not use water, benzene, thinner or alcohol onto
the product but only use dry duster.
CLEANING
NOTICE
POWER
Caution
To avoid users’ damages and to keep safe, please read this precautions.

9
Customer Center 02-2625-2222 (Tel)02-2625-2228 (Fax)
jenix@jenix.co.kr
8. SPECIFICATIONS
Model
Height range
Height method
Weight range
Weight method
Tolerance
Input
Output
Display
Material
Size (mm / inch)
Product weight
Temperature range
Measuring order
Measuring time
Device for leveling
Error compensation
Voice output
Print out
Fatness Formula
Features
DS-103M (Height, Weight auto measuring system)
90 ~ 200cm (measuring unit: 0.1cm)
Magnetic linear encoder
10 ~ 200kg (measuring unit: 0.1kg)
Load cell
Height: ±0.1cm (±0.003ft), Weight: ±0.1kg(±0.220lb)
AC 110V/220V, 50-60Hz, 1A
DC 12, 2A
Digital Value on 7 segments (FND)
Aluminum
410(W)×550(L)×2190(H)
12kg / 26.46 lb
10℃ ~ 40℃
Height, Weight and BMI simultaneously
5 seconds (for measurement of height and weight)
5pcs of rubber headed screws
User's operation (refer to user's manual)
English / Chinese / Korean (select one when buying)
Optional. Select one out of RS232 & Blue tooth
Fatness (WHO standard), BMI (KMA standard)
Easy to use, Excellent stability and design
Adapter
* A printer is optional.
* Blue tooth application can be downloaded from Google Play (Android only).
2 ultrasonic sensors are built in the touch bar for smooth touching.
/ 2.95~6.56 ft
/ 22.05~440.92 lb
/ 50℉~104℉
/ 16.1"(W)x21.7"(L)x86.5"(H)


DONG SAHN JENIX CO., LTD.
www.jenix.co.kr
1283 Oriro Guro-gu, Seoul, Korea Tel 82 2 2625 2222 Fax 82 2 2625 2228 jenix@jenix.co.kr
Healthy life Happy life
Table of contents