JNJ SPAS SPA-329 User manual

1
PROGRAMMING INSTRUCTIONS
1. Illustration to buttons
F
AM
PM
LIGHT
OZONE
OFFON
PUMP2BLOWER PUMP1 PUMP3
SET
LOCKED HEAT
C
F/
OZONE
PUMP2
HEAT
PUMP3
ON/OFF
CD
MEM
CLOSE
HOUR
OPEN
MIN
SET
VOL+
TEMP
Fig﹒1:Sketch map of big massage bathtub
“
MIN
”Radio channel up / Minute
“
ON/OFF
”power On/ Off or mode shift
“
HOUR
”radio channel down/ Hour
“
CD
RADIO
”radio on/ off or CD shift
“
SET
VOL+
”volume up/ time setting shift
“
CF/
”blower on/ off or ℃& ℉Shift
“
OPEN
”volume down/ open memory channel
“ ”LED & fiber optic lights on/ off
“
MEM
”radio channel memory/ lock channel
“ ”whirlpool pump 1&2 on/ off
“
CLOSE
”select radio channel / close channel
“
PUMP2
”waterfall & column pump on/ off
“
OZONE
”ozonizer on/off
“
PUMP3
”whirlpool pump 3 & circulation pump
on/ off.
“
HEAT
”preheat on/ off or preset
“
TEMP
”Temperature setting
Note:
1. All the functions listed on the key in blue letter only works on the “off” model.
2.
PUMP2
function is not available on SPA-329,312, which model without water column and waterfall.

2
2. Functions Summary
(1) Constant heating, preheating, displaying and setting water temperature.
(2) Display time in AM & PM 12 hours mode.
(3) Circulation cleaning and presetting circulation cleaning.
(4) Radio, 10 channels memory or circumscribe device of CD or DVD, offering power output for DVD/CD and TV
set.
(5) Display and adjust 87 grade volume.
(6) Infrared remote control.
(7) Underwater multicolor LED light and ozone.
(8) Freezing-proof protection.
(9) Functions memory when power shut down suddenly
(10)Fahrenheit & Celsius temperature display shift.
(11) Three whirlpool pumps,One circulation pump, One water Column & waterfall pump, One blower.
(12) Functions locked on panel.
(13) Limit working watts control (optional)
(14) Selection of 110-120V/60Hz, 220-240V/50-60Hz, or 380-415/50Hz
3. Operations
1) When the spa is connect with power, the control panel will be in dark light, and LCD screen on the panel will be
displaying time and current water temperature, and the radio channel will be display “---“. Under the situation, it
indicates the spa system is on off status, the preheat and circulation cleaning functions are turned off.
If the water temperature sensor is broken circuit, the screen will display“E1”, if the water temperature sensor is
short circuit, the screen will display” FF”. In this case, the heater can not work normally, please check the wire of
which is connecting with the water temperature sensor.
AM
AM
Fig﹒3:normal water temperature. Fig﹒4:water temperature sensor broken circuit
2) Lock operation :
This is a manual and automatic function. If there is no any operation on the panel in 30 minutes, all the current
working functions will be locked automation.
On the “off” status, press the “
MEM
”the key to lock any functions, and the screen will display the “locked
“ signal.To press the“
MEM
”key twice to unlock the functions,once the function is unlocked, the
“ locked” signal will disappear on the screen.
3) Time setting operation:

3
On the “ off” status and the preheat and circulation cleaning without working, press“
HOUR
”or “
MIN
”
key to start time setting.。The “:” signal will stop to flash, but the minute and hour will flash at this time。
To press the “
HOUR
”key one time,will add one hour, the hour number will be displaying on the screen.
Pressing the“
HOUR
” without stop, the hours will increase continually till stop pressing the key. The hours
adjustment range is AM 0~PM 11.
To press the “
MIN
”key one time,will add one minute, the minute number will be displaying on the screen.
Pressing the“
MIN
”without stop, the minutes will increase continually till stop pressing the key. The minutes
adjustment range is 0-59.
After finishing the time setting, the system will quit out the time setting mode in 6 seconds.
4) Operation to circulation-cleaning setting:
Only one circulation-cleaning program can be set in one day in a spa. The circulation cleaning working status will
be displaying on the LCD screen. When it works or can not see from the screen. If the “ ”signal is
displaying on the screen, it indicates the circulation-cleaning is on, and the“ ” signal is disappeared, it
indicates the circulation cleaning is off. See following Fig﹒5-6.
AM
AM
Fig﹒5:Circulation-cleaning off Fig﹒6:Circulation-cleaning on
All the setting steps of circulation-cleaning must be operated on the “off” status, the LCD screen will be displaying
“---”at this status.
(1) 、Press “
PUMP3
”, to enter the Circulation-cleaning setting model, and the screen will flash the
“ ”signal.
(2)、Press“
OPEN
”,can start the circulation-cleaning setting (If press“
CLOSE
”key, or without any pressing
in 6 seconds ,the circulation-cleaning will be shut down, and the system will quit out the setting model
automatically.), And this time,“ ”signal won’t flash。The system enter into the setting mode for the
start time of circulation-cleaning setting, the screen will flash a time number (this time is the start time of the
circulation-cleaning.), at this moment,press the “
MIN
”and“
HOUR
” key to set the time.

4
To press the “
HOUR
”key one time,will add one hour, the hour number will be displaying on the screen.
Pressing the“
HOUR
” without stop, the hours will increase continually till stop pressing the key. The hours
adjustment range is AM 0~PM 11.
To press the “
MIN
”key one time,will add one minute, the minute number will be displaying on the screen.
Pressing the“
MIN
”without stop, the minutes will increase continually till stop pressing the key. The minute
adjustment range is 0-59.
After seting the start time of Circulation-cleaning,and move on to set the working time of circulation-cleaning.
(3)、Press “
SET
VOL+
”key to shift to the setting mode of the working time of circulation-cleaning. At this
moment, the time displaying on the screen is at least 5 minute., the working time number on the screen
won’t flash. To press the “
MIN
”key one time, the working time will add 5 minute. The maximum
working time of circulation time is19 hours 55 minutes(this time can be adjusted according to the user).
After setting the working time of Circulation-cleaning,and move on to set the ozone working in synchronization
(4)、And then press the“
SET
VOL+
”key again to set startup the ozonizer working in synchronization, at this
time, the “
OZONE
”signal will be flashing on the screen. This flashing signal indicates the ozonizer doesn’t
work in synchronization. Press the“
OZONE
”key to startup the ozonizer, when the ozonizer woks, the
“
OZONE
”signal will be displaying on the screen.
(5)、after the steps are done, press the”
PUMP3
”key to confirm the setting, or wait for 6 seconds, the
system will confirm the circulation cleaning setting and quit out setting mode.
Detailed steps refer to the below Fig.
(1)
PUMP3
MIN
(2)
OPEN
set: start time of Circulation-cleaning
HOUR
(3)
SET
VOL+
MIN
set: working time of Circulation-cleaning
(4)
SET
VOL+
OZONE
startup ozonizer in synchronization

5
(5)Press “
PUMP3
”to confirm
*** Notice ***
(1)、the setting steps of Circulation-cleaning must be operated on the “ off” status.
(2)、During the whole setting process, the circulation pump and ozonizer are not
working.
5、Preheating setting:
Only one preheating setting program can be set in one day in a spa. The preheating woking status will be
displaying on the LCD screen. If it’s work or not ,can be seen from the screen. If the “ON”signal is diplaying on
the screen, it indicates the preheating is working, and the“OFF”signal is displaying on the screen, it indicates
the preheating is not working. See following Fig﹒7-8.
AM
ON
AM
OFF
Fig﹒7:Preheating On Fig﹒8:Preheating Off
All the setting steps must be operated on the “ off” status, the LCD screen will be displaying”---“ signal at this
status.
(1)、Press“
HEAT
”, to enter into the preheating setting model, and the screen will flash the “ON/OFF” signal.
(2)、Press“
OPEN
”,can start the preheating setting (If press“
CLOSE
”key, or without any pressing in 6
seconds ,the preheating will be shut down, and the system will quit out the setting model automatically.), the
signal on the screen will be from” ON/OFF” turn into “ON”, won’t flash, just displaying, The system is on the
setting mode for the start time of preheating setting, the screen will flash a time number(this time is the start
time of the preheating. (Press on the “
CLOSE
”key can turn show down preheating setting, and the “OFF”
signal will be displaying on the screen).
at this moment,press the “
MIN
”and“
HOUR
” key to set the time.
To press the “
HOUR
”key one time,will add one hour, the hour number will be displaying on the screen.
Pressing the“
HOUR
” without stop, the hours will increase continually till stop pressing the key. The hours

6
adjustment range is AM 0~PM 11.
To press the “
MIN
”key one time,will add one minute, the minute number will be displaying on the screen.
Pressing the“
MIN
”without stop, the minutes will increase continually till stop pressing the key. The minutes
adjustment range is 0-59.
After setting the start time of preheating,and move on to set the working time of preheating.
(3)、Press “
SET
VOL+
”key to shift to the setting mode of the working time of preheating. At this moment, the
time displaying on the screen is at least 10 minute, the working time number on the screen won’t flash.
Pressing the “
MIN
”key each time, the working time will add 10 minute, Pressing the “
HOUR
”
key each time, the working time will add one hours . The maximum working time of preheating is 19 hours
50 minutes.
After setting the working time of preheating,and move on to set water temperature.
(4)、And then press the“
SET
VOL+
”key to set the water temperature, at this time, the “SET”signal will
be flashing on the screen. Pressing the“
TEMP
”key to increase the temperature, loose the key when
temperature reach the require degrees. The limited temperature is 18-40℃.
(5)、after all steps are done, press the”
HEAT
”key to confirm the setting, or wait for 6 seconds, the
system will confirm the preheating setting and quit out setting mode.
(1)
HEAT
MIN
(2)
OPEN
set: start time of Preheating
HOUR
MIN
(3)
SET
VOL+
set: working time of preheating
HOUR
(4)
SET
VOL+
TEMP
set: temperature degrees
(5)Press“
HEAT
”to confirm

7
*** Notice ***
1、all the setting steps of preheating must be operated on the “off” status, and the
LCD displays “---”.
2、Please note that if the screen shows "on" or "off". If the screen showing "on"
signal, indicates preheating function is on. , when the time reach to the set time
of preheating, the heater will work automatically. If the screen show "off"
signal, indicates preheating setting is not successfully, the heater won’t start at
anytime, please reset the preheating program.
3、During the whole setting process, the circulation pump and heater are not
working.
6、Preheating working status:
When time reach the set time of preheating program, and the “ON” signal of preheating is displaying on the
screen, meanwhile, the tub is filled with enough water. The preheating program will be startup automation, the
heater beginning to heat and the circulation pump will be working at the same time. The screen is showing the
countdown of preheating.
Once the temperature reach to the setting degrees, the heater will stop heating automatically. Once the
temperature is below the setting degrees, the heater will begin to heat automatically. As soon as the countdown
time is finished, the preheating program will shut down, and heater stop working automatically.
During the preheating process, to press the“
HEAT
”key or“
ON/OFF
”key to quit out the preheating
program, turn off the heater.
7、Circulation-cleaning working status:
On the “off” status, when time reach the set time of circulation-cleaning, and the “ ”signal of circulation
cleaning is displaying on the screen, meanwhile, the tub is filled with enough water. The circulation-cleaning
program will be start-up automatically, the circulation pump and ozonizer will begin to work at the same time. The
screen is showing the countdown of circulation-cleaning.
The working time of ozonier is: works for 15 minutes and stop for one hour and 45 minutes, and then begin to
works for 15 minutes and stop for one hour and 45 minutes. This working status will last till the
circulation-cleaning time is finished.
As soon as the countdown time of is finished, the circulation-cleaning program will shut down automatically.
During the circulation-cleaning process, to press the “
ON/OFF
”key to shut down the circulation-cleaning
program, the circulation pump will be off automatically.
*** Notice ***
1, if the setting temperature is lower than or equal with water temperature in the tub,
Even the Preheating program is on, the circulation pump and heater won’t be working.
2, For the “I” type heater, the circulation pump must be or more than 1HP, otherwise
there is no enough water pressure in the heater tube to push on the valve of water
pressure sensor, so the heater can’t start to work.(there is a water pressure sensor in
the heater tube).

8
3, If the above conditions are delivered, and the heater is still not working, please draw
the wire of water pressure sensor from the heater, then connect two ends of this wire
directly, and the heater will works normally.
8、Turn ON/ OFF operation.
On the “off” model, to press the “ ”key to turn on, and press the “ ” key again to turn off. When all
systems was turned off and the screen shows “---“signal; when it was turned on, the”---“signal will disappear. Like
the following Fig.
AM
OFF
AM
OFF
Fig﹒9:OFF Fig﹒10:ON
9、Temperature setting
On the “on” status, meanwhile, the heater is working, the temperature can be adjusted. To press the“
TEMP
”
key each time, the temperature will add one degree. Pressing the “
TEMP
”key without stop, the degree will
increase continually till 45℃. When the degree is reach 40℃,to press the “
TEMP
”key, the degree will be 18℃
again. The adjustable temperature degrees is 18-45℃.
10、Operation of Radio & CD:
AM
PUMP3
Fig.11:Radio frequency is 105.2 MHZ,Save the present frequency to channel 3 (Save channel)
or Exchange the frequency form channel 3 to the present (Searching channel)
Ⅰ)、Key
AUDIO
CD
is the ON/OFF key for radio and CD。It is only available in the status of power on. The first
pressing is turning on the radio,the second pressing will turn off the radio and turn on the CD at the same time,
and the third,will turn off the radio and CD simultaneous.
Ⅱ)、LCD will show present frequency and volume of the radio after turning on the radio。
Ⅲ)、on the working of status,The volume of the present radio frequency can be changed by pressing
“
MIN
”&“
HOUR
”。
Ⅳ)、Pressing the key “
CLOSE
”will take out the memorized radio frequency,Pressing the key

9
“
CLOSE
”continually will take out the memorized radio frequency from channels will be saved at present
channel by pressing this key continually。If none of the channel,LCD will display “---”。
Ⅴ)、Press the key“
MEM
”could memorize the present radio channel,Pressing the key
“
MEM
”continually to select the present radio channel from memory。The channel of max is 10,
situations of channel is 0-9。
Ⅵ)、The volume can be changed by pressing key “
SET
VOL+
”&“
OPEN
”。
11、Operation of Pump :
The “Pump1” key are controlling two whirlpool pumps for massage, the “Pump2” key is controlling for the
pump for water Column & waterfall. the “Pump 3” key is controlling a single whirlpool pump for massage. When
press the “pump 3” key,the screen is displaying the””signal. ( if the screen is displaying the signal
“”, this signal is indicating the circulation pump is working).
12、Operation of Ozone:
The ozone could be working on the circulation-cleaning program.
Press the key “
OZONE
”to turn on/off the ozonizer. After the ozonizer is turned on, it will last working forever
till it is turn off.
The working situation is working 15 minutes every two hours, in other words, works for 15 minutes and stop for
one hour and 45 minutes, and then begin to works for 15 minutes and stop for one hour and 45 minutes.
13、Operation of lights:
To press the “ ”key to turn on or off the underwater light and fiber optic lights.
All the lights can be turned on on any mode, so to turn on is way to test if the spa system is connect with power
successfully or not.
14、Operation of constant water temperature:
1), To press the “
HEAT
”key two times( the first time is to turn on the circulation pump)to turn on the heater,
and press “
TEMP
”to set the temperature degrees. The heater will be working, not stop,till the
temperature reach the set degrees. Once temperature is below the set degrees, the heater will begin to work
again automatically . For example:if the temperature is set at 35,when the water temperature reaches or
exceeds 35,the heater will be shut down automatically and the circulation pump will stop too in 5 seconds.
However,when the water temperature reach or lower than 34,the heater will start up automatically again to
heat the water. In this way, the user can keep the same water at anytime if the spa system is with power.
2)、If the water temperature sensor is broken circuit, the screen will display “E1”, if the water temperature sensor
is short circuit, the screen will display” FF”. In this case, the heater can not work normally, please check the wire
of which is connecting with the water temperature sensor.
15、Operation of blower:

10
1)To press the“
CF/
”key to turn on/off blower. The blower can work without any water in tub. So it’s way to
test if the spa system connect with power successfully or the controller is working or not?
2) Blower will be shut down automatically after it has been working for 2 hours.
16、Fahrenheit & Celsius temperature shift:
On the “ off” mode, to press the“
CF/
”key to shift the Fahrenheit or Celsius degrees.
17、If the water lever in the tub is not reaching the water level sensor, no pumps, no
heater, no ozonizer can be turned on, expect the blower. The signals will be flashing on
the screen.
18、Frozen preventing control:
The heater & circulation pump will be turned on automatically when water temperature is below 5℃,and will be
shut down when the temperature reaches 10℃. To keep this function on, must ensure the spa is connect with
power well.
4.Electric parameters
(1) Performance index:
Rated voltage:220VAC/50Hz(110VAC/60Hz)Maximum working current:60A(100A/110V)
Voltage-resistance:1250V/1 minute without penetration。Isolative resistance :>=200MΩ
Water resistance grade:IPX5。Electric shock resistance:first grade
(2) Output loading index
Heater:AC220V/3KW x 1 Surf Water pump:AC220V/3 HP x 1
water pump:AC220V/2HP x 2 water pump:AC220V/1HP x 1
Air pump:AC220V/0.7kw x 1
spa light:AC12V/5W x 2 Ozone:AC12V/15W x 1
water pump:AC220v/0.35HP x 1
Radio:1) Frequency Range:FM:87.0~108.0MHz
2) Maximum Output Power:10W
3) Speaker:8Ωdamp proof speaker
5. Warning Information
a. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
b. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
c. This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
d. Children should be supervised to ensure that they do not play with the appliance.
e. Details concerning cleaning and other maintenance
f. Maintenance of water purity, especially PH values and chlorine concentrations.
g. Cleaning and disinfection
h. Use and installation of a cover.
i. Disposal of water
j. Precautions to avoid damage due to water freezing
k. Precautions to avoid damage when the appliance is left empty for extended period.
2.2 Sub-clause 7

11
The installation instruction shall state the substance of the following:
-Earthed appliances must be permanently connected to fixed wiring;
-The appliance should be supplied through a residual current device (RCD) having a rated residual operating
current not exceeding 30 mA.
-The floor has to be capable of supporting the expected load.
-An adequate drainage system has to be provided to deal with overflow water.
-Details of how to follow the wiring rules, for example, specifying that parts are installed in the correct
zone and that equipotential bonding is carried out.
WARNING
1、DANGER:RISK OF ELECTRIC SHOCK,Connect only to a circuit protected by a Ground
Fault Circuit lnterrupter.
2、Grounding is required. The unit should be installed by a qualified service representative and
ground.
3、FOR YOUR SAFETY-This product should be installed by a professional service
technician,qualified in hydrotherapy bath installation.
4、lt’s prohibited to cover the instrument with something while operating.
5、when using at the first time ,Be sure there is water in heater pipe before staring.

12

13
Table of contents
Other JNJ SPAS Hot Tub manuals
Popular Hot Tub manuals by other brands

Aquatic
Aquatic HOTSOAK 69 AI16AIR7036HS Specification sheet

Marquis
Marquis ULTIMATE HOT TUB EXPERIENCE! owner's manual

Canadian Spa
Canadian Spa ERIE SE GL owner's manual

KIRAMI
KIRAMI Premium Pearly Instructions for use

Jacuzzi
Jacuzzi Nova 5 Specification sheet

Conair
Conair Deluxe MBTS4TC Instruction booklet

treesse
treesse Rest Preinstallation manual

Aquatic
Aquatic HOTSOAK 64 AI5AIR6636HS Specification sheet

Jacuzzi
Jacuzzi SIGNA 5 Specification sheet

Image
Image IMSB63120, IMSG63120 user manual

American Standard
American Standard Cadet Elite 2773EC Features & dimensions

Medisana
Medisana FS 888 instruction manual