Installation Manual for Snow Protection Hood (for Outdoor Unit)
This snow protection hood prevents snow from entering the outdoor unit and to prevent strong winds from
blowing against the heat exchanger. Be sure to read this manual carefully for correct performance before
installation work.
: Indicates a hazardous situation that, if not avoided,
could result in death or serious injury.
: Indicates a hazardous situation that, if not avoided,
could result in minor or moderate injury.
1. Applicable Unit
Name Hood for Air Outlet
Model ASG-TP50FCS
Applicable Outdoor Unit
(Representative Model)
(H,Y)VAH(P,R)168, 192B32S
(H,Y)VAH(P,R)168, 192B42S
(H,Y)VAH(P,R)168, 192B52S
NOTICE:
7KHDSSOLFDEOHRXWGRRUXQLWPD\EHGLႇHUHQWGHSHQGLQJRQWKHSURGXFWVHULHV%HVXUHWRFRQ¿UPZLWKWKH
product catalogue before installation.
2. Installation Work
(1) After the snow protection hood is installed, noise at the air outlet side may slightly increase. Consider
carefully the air discharge direction when installing.
(2) Tighten the snow protection hood securely to the top panel and side panel of the outdoor unit with the
supplied screws (accessories). Not doing so may cause vibration or abnormal noise.
(3) Avoid obstacles in the direction of air discharge from the snow protection hood to prevent short circuit
RUDUHGXFWLRQLQWKHDLUÀRZUDWH
(4) Do not install other outdoor units in the direction of the air outlet. If the air blown out of the snow
protection hood is sucked into the other outdoor unit, it may cause a malfunction of the unit.
(5) Double-check the strength of the anchor bolts of the outdoor unit. The wind loads on the outdoor unit
change by attaching the snow protection hood. The required installation strength also changes in
strong wind.
$IWHULQVWDOOLQJWKHVQRZSURWHFWLRQKRRGFRROLQJKHDWLQJSHUIRUPDQFHPD\EHVOLJKWO\DႇHFWHG
depending on usage.
IMPORTANT NOTICE:
• Johnson Controls-Hitachi Air Conditioning pursues a policy of continuous improvement in design and
performance of products.
:HUHVHUYHWKHULJKWWRYDU\VSHFL¿FDWLRQVZLWKRXWQRWLFH
• Johnson Controls-Hitachi Air Conditioning cannot anticipate every possible circumstance that might involve
a potential hazard.
• No part of this manual may be reproduced without Johnson Controls-Hitachi Air Conditioning’ written
permission.
• Keep this manual for future reference.
• Do not use this kit by itself or in combination with other companies’ air conditioners. This kit is designed for
a combination of Johnson Controls-Hitachi Air Conditioning air conditioners only.
• 8VHWKH¿HOGVXSSOLHGVDIHW\ZLUHURSHWRSUHYHQWRXWGRRUXQLWIURPRYHUWXUQLQJ8VHDVWD\RUVDIHW\ZLUH
rope to hold the snow protection hood properly to the outdoor unit against a strong wind or earthquake, for
reinforced installation.
• Perform a test run after installation to check for abnormalities.
• 8VHVLJQDOZRUGVWRLGHQWLI\OHYHOVRIKD]DUGVHULRXVQHVV'H¿QLWLRQVIRULGHQWLI\LQJKD]DUGOHYHOVDUH
provided below with their respective signal words.
1

Service Space for Multiple Outdoor Units Installation
Sealing Procedures (Example)
1
Sealing Agent
(field-supplied)
(field-supplied)
Fill the screw hole
with sealing agent.
Field Supplied
Materials
Clear Sealing Agent with High Viscosity
A silicone (RTV) sealant with a temperature range
from -65oF to 650oF (-54oC to 343oC) intermittent.
Cloth for wiping off surplus sealing agent
Screw into the hole filled with
sealing agent.
* Wipe off any excess sealer
with a cloth.
Screw
(accessories)
Sealing Agent
2
Hood for Left Side Air Inlet
Outdoor Units
Min. 2 inch (50mm) Min. 2 inch (50mm)
Hood for Right Side Air Inlet
If no air inlet hood is provided
between outdoor units,
2 inch (50mm) or more space
is required for servicing.
To hold the snow protection hood properly to the outdoor unit against a strong wind or an earthquake, use
safety wire rope reinforced installation and to prevent the outdoor unit from overturning.
Ɣ ,QVWDOOWKHVQRZSURWHFWLRQKRRGWRDYRLGGLUHFWIDFLQJWKHVHDVRQDORUVWURQJZLQG
Ɣ 3URWHFWWKHVFUHZVDQGWKHVQRZSURWHFWLRQKRRGIURPVFUDWFKHVRUVFUDSHVWKDWPD\FDXVHUXVW
Handle with care the snow protection hood during assembly and installation.
Ɣ $SSO\WRXFKXSFRDWLQJRUVHDOLQJ¿HOGVXSSOLHGDWWKHVFUHZKROHVRIWKHRXWGRRUXQLWLQRUGHUWR
prevent rusting.
Ɣ (YHQWKRXJKWKHKRRGLVVWDLQOHVVVDOWRULURQPD\FDXVHUXVW%HDZDUHRIWKLVGXULQJLQVWDOODWLRQRU
maintenance.
Ɣ 7KHVQRZSURWHFWLRQKRRGLVKHDY\ZHLJKW0RUHWKDQWZRSHRSOHDUHUHTXLUHGIRULQVWDOODWLRQ%HVXUH
to wear personal protective equipment (PPE).
3. Selection of Installation Location
(1) Install the outdoor unit at the suitable height in consideration of snow accumulation. Increase the base
height or additionally provide the frame under the unit (higher than snow accumulation), and secure
the outdoor unit securely with anchor bolts.
(2) Install the unit at location where fallen snow from the building does not hit.
(3) Ensure adequate service space in consideration of snow accumulation height and snow removal
operation.
(4) Clear away any obstacles. There must be no obstacles in the air discharge direction.
(5) When installing multiple outdoor units, provide service space as shown below.
2

4. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: inch (mm)
No. Accessory Qty. Remarks
ASG-TP50FCS
1Right Side Plate 1
2Left Side Plate 1
3Faceplate (1) 2
4Faceplate (2) 2
5Faceplate (3) 2
6Center Support 1
7Horizontal Plate 2
8Screw
(for Assembling)
M5 x 9/16L (14L)
(tapping screw
type C)
42
(2)
Used for assembling.
Use with a weld nut.
(2): Spare
9Screw
(for Installation)
M5 x 1/2L (12L)
(tapping screw
type B)
5
(1)
Used for installation.
Use with a burred,
threaded hole.
(1): Spare
3

5. Installation Procedures
(1) Secure the faceplate (2) ( 4) with the right side plate ( 1) and center support ( 6) together (two
places) by using the assembly screws ( 8).
(3) Secure the faceplate (2) ( 4) then faceplate (1) ( 3) with the left side plate ( 2) and the assembled
parts in step (2) together by using the assembly screws ( 8).
(2) Tighten the faceplate (1) ( 3) by using the assembly screws ( 8).
4
8
6
1
8
8
3
84
2
8
8
3
4

(4) Remove the screws for securing the outdoor unit top plate (eight places), then secure the snow
protection hood (for air outlet) with those removed screws (four places) and installation screws ( 9) (four
places).
(5) Remove the screws for securing the outdoor unit top plate, then secure the faceplate (3) ( 5) (two
pieces) and horizontal plate ( 7) (two pieces) to the outdoor unit and the snow protection hood (for air
outlet) with those removed screws and assembly screws ( 8).
Snow Protection Hood
(for Air Outlet)
Outdoor Unit
Screws for
Fixing Top Plate
9
Snow Protection Hood
(for Air Outlet)
Outdoor Unit
Screws for
Fixing Top Plate
Screws for
Fixing Top Plate
Screws for
Fixing Top Plate
Screws for
Fixing Top Plate
8
5
78
7
5
5

6. Installation Appearance
Outdoor Unit
89-1/8
(2264)
15-3/4
(400)
15-3/4
(400)
15-3/4
(400)
Safety Wire Rope
to Prevent Overturning
(Field-Supplied)
Hood for
Side Air Inlet
(Other Snow Protection
Hood Option)
Hood for
Left Side Air Inlet
(Other Snow Protection
Hood Option)
Hood for Air Outlet
Hood for
Rear Side Air Inlet
(Other Snow Protection
Hood Option)
63-7/16
(1611)
63
(1600)
30-1/8
(765)
30-1/8
(765)
Available Combinations
Applicable Outdoor Unit
(Representative Model)
Model
(H,Y)VAH(P,R)168, 192B32S
(H,Y)VAH(P,R)168, 192B42S
(H,Y)VAH(P,R)168, 192B52S
Hood for Air Outlet ASG-TP50FCS
Hood for Rear Side Air Inlet ASG-TP50BCS
Hood for Left Side Air Inlet ASG-TP50RS
Hood for Right Side Air Inlet ASG-TP50RS
NOTICE:
This manual applies only to the combination indicated with .
For other snow protection hood options, refer to each installation manual.
Unit: inch (mm)
6

7. Maintenance and Servicing
Even if during the warranty period, the snow protection hood becomes rusted under conditions that are
caused by alkaline or corrosive moisture, it is recommended to provide salt damage resistance products to
prevent such damage.
,QRUGHUWRSURORQJWKHSURGXFWOLIHSHUIRUPSHULRGLFDOPDLQWHQDQFHWRSUHYHQWVLJQL¿FDQWDJLQJGXHWR
deterioration. Perform the following tasks as part of routine preventative maintenance for the equipment.
(1) Red Rust Generation Check
,IUHGUXVWLVJHQHUDWHGVFRXUWKHUXVWRႇ
(2) Retighten installation and assembly screws.
Check for loose screws and retighten when inspection and maintenance is performed. In order to
SUHYHQWVFUHZEUHDNDJHEHVXUHWRWLJKWHQWRWKHIROORZLQJWRUTXHVSHFL¿FDWLRQV
* M5 Tapping Screw Type C for Assembling 8: 2.6 + 0.7 [Ibf-ft] (3.5 + 1.0 [N•m])
* M5 Tapping Screw Type B for Fixing Top Plate: 1.8 + 0.7 [Ibf-ft] (2.5 + 1.0 [N•m])
7

© 2017 Hitachi-Johnson Controls Air Conditioning, Inc.
Code No. LIT-12012438
Revised January 2020
P5416962-rev.2
Table of contents
Other Johnson Controls Ventilation Hood manuals

Johnson Controls
Johnson Controls ASG-TP20FAS1 User manual

Johnson Controls
Johnson Controls ASG-TP20RS2 User manual

Johnson Controls
Johnson Controls ASG-TP50BAS User manual

Johnson Controls
Johnson Controls ASG-TP50RS User manual

Johnson Controls
Johnson Controls ASG-TP20LS2 User manual

Johnson Controls
Johnson Controls ASG-TP50LS User manual