WARNING
1. Please carefully read and fully understand the warnings
and operating instructions before use. If the equipment
is used in a manner not specied by the manufactur-
er, the protection provided by the equipment may be
impaired.
2. Please test the detector on a known live source within
the rated AC voltage range before use.
3. If the detector appears damaged or is not working
properly, stop using it immediately.
4. Do not attempt to detect voltage higher than 1000V.
5. Use caution when working with voltages above AC
30Vr.m.s, 42V peak or DC 60V. Such voltages pose
a shock hazard. Clean the tester casing with a damp
cloth and mild detergent. Do not use abrasives or
solvents!
6. There may still be voltage even when no acousto-optic
alarm is on.
7. The insulation type, wire thickness, distance from
voltage source, shielded wire, other wires, socket
design, and other factors may adversely a󰀨ect test
result. If there are uncertainties, use other methods to
verify the voltage.
8. Do not assume neutral or ground wire is safe to touch.
Incorrect or poorly connected circuits may cause wires
to be charged.
9. When low battery indication appears, please replace
batteries.
10. Use caution when using the tool, keep hands away
from clear tip.
11. Comply with local and national safety regulations
and requirements.
12. The detector will not detect any voltage if:
• The wire is shielded
• The operator is not connected with the ground or
isolated from e󰀨ective ground
• The voltage is DC
13. The detector may not detect voltages if:
• The operator does not hold the detector
• The operator is wearing gloves
• The wire under test is partially buried or in a
grounded metal conduit
• The magnetic eld generated by the voltage source is
blocked, suppressed or interfered with
• The frequency of the voltage being detected is not
perfect sine wave and may be distorted by harmonics
The detector is used outside of the operating
specications (see Technical Specication for details)
Low voltage mode (24V AC - 1000V AC)
Suitable for testing low-voltage motor (<90V), audio systems, arc
welding machines, underground mine lighting, cables with thick
insulation layer, and other weak electromagnetic AC signals.
High voltage mode (90 AC - 1000V AC)
For detecting urban electric supply and three-phase systems.
For example, power distribution units, electrical panels, electrical
appliances.
Operating Instructions
1. Turning on the detector
Short press the power button. The buzzer will beep twice
and the red indicator light on the panel will light up, indicat-
ing that the detector is on and ready for use. The default AC
voltage detection range is 90-1000V.
2. Turning on/o󰀨 the ashlight
Flashlight on/o󰀨: Short press the ashlight button to turn
on/o󰀨 the ashlight. The ashlight will automatically turn o󰀨
when the detector is not used for 5 minutes or press
ashlight button again to turn o󰀨 immediately.
3. AC voltage detection
Place the sensor head near the test object or the power
socket with the AC voltage. When AC voltage is detected,
the red LED in the tip and buzzer will be on. Sensing Buzzer
and LED increase in frequency when the detector gets closer
to the test object. Note: Please unplug other
electrical devices on the socket before detection.
4. Detection range selection
1) When the detector is on, the default mode is high voltage
mode, with detection range 90-1000V. The red indicator light
will switch to green, and the device will switch to low voltage
mode, with range of 24-1000V. In low voltage mode, the
detector is more sensitive to electrical interferences/noise.
Please only use low voltage mode during weak electrical
eld environment.
VT-1100 - VOLTAGE DETECTOR
USER MANUAL
5. Auto power o󰀨
The detector will auto power o󰀨 when it is not used for 5
minutes.
6. Turning o󰀨 the detector manually
Long press the power button for 2 seconds to tum o󰀨 the
detector
Technical Specications
7. Low battery Indication
When the battery voltage is lower than 2.4V, the detector will
automatically shut down.
Battery Replacement
1. Hold the detector with one hand,
use your thumb of the other hand to
press down on the battery
compartment latch, and pull the end
of the detector.
2. Pull out the end of the detector
along the direction shown at right
pictures and replace the batteries.
WARNING:
Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zlnc), or rechargeable
(nl-cad, nl-mh, etc) batteries.
Standards: IEC/EN61010-1, IEC/EN 61010-2-030,
IEC/EN 61326-1, IEC/EN 61326-2-2
VT-1100 - VOLTAGE DETECTOR
USER MANUAL
Tel 914.793.0700 | Fax 914.793.4527 | jonard.com
VT-1100

Popular Security Sensor manuals by other brands

STEINEL Multisensor True Presence BT IPD manual

STEINEL

STEINEL Multisensor True Presence BT IPD manual

Oregon Scientific MSR939 user manual

Oregon Scientific

Oregon Scientific MSR939 user manual

Wetekom 25 44 41 instruction manual

Wetekom

Wetekom 25 44 41 instruction manual

Dorlen Water Alert SS-1 instructions

Dorlen

Dorlen Water Alert SS-1 instructions

STEINEL IS 360 D TRIO installation instructions

STEINEL

STEINEL IS 360 D TRIO installation instructions

Hytronik HIM38/RF Installation and instruction manual

Hytronik

Hytronik HIM38/RF Installation and instruction manual

HomeMatic HMIP-SMO-2 Mounting instruction and operating manual

HomeMatic

HomeMatic HMIP-SMO-2 Mounting instruction and operating manual

FireClass FC400CH quick start guide

FireClass

FireClass FC400CH quick start guide

Ansell VIKING PROTECH II owner's manual

Ansell

Ansell VIKING PROTECH II owner's manual

Scott Alpride Series quick start guide

Scott

Scott Alpride Series quick start guide

STEINEL IS 180-2 installation instructions

STEINEL

STEINEL IS 180-2 installation instructions

Trox Technik RM-O-M Installation and operating manual

Trox Technik

Trox Technik RM-O-M Installation and operating manual

Siemens 5SM6011-1 operating instructions

Siemens

Siemens 5SM6011-1 operating instructions

PCB Piezotronics IMI SENSORS 641B01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 641B01 Installation and operating manual

PCB Piezotronics ICP 105C12/NC Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP 105C12/NC Installation and operating manual

INIM ED100 Product description

INIM

INIM ED100 Product description

TAKATA 3-POINT SEAT BELT installation guide

TAKATA

TAKATA 3-POINT SEAT BELT installation guide

Megger Detex 514242 Series instruction manual

Megger

Megger Detex 514242 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.