5/8
Analog Output
JXBS-3001-EC Soil Electric Conductivity Sensor User Manual
TABLE 3 Wiring Sequence
Power supply Positive ( 12-24V DC )
Voltage/current output Positive
Voltage/current output Negative
We provide default cable length of 1.5meters, you can extend the cable yourself according to your needs.
2.3 Speed measurement method
Select the appropriate measurement site, avoid the stones, ensure that the steel needle does not hit a hard object,
throw the topsoil at the required depth of measurement, keep the underlying soil tightness, grip the sensor
vertically into the soil, insert It is not possible to shake left and right. It is recommended to measure multiple times
within a small area of a measurement point to obtain the average value.
2.4 Buried method
Dig a pit with a diameter of >20cm vertically and insert the sensor steel needle horizontally into the wall of the pit
at a predetermined depth. After the pit is buried tightly and stable for a period of time, it can be measured and
recorded for several days, months, or even longer.
2.5 Precautions
1, steel needle must be fully inserted into the soil.
2. Avoid direct sunlight on the sensor and cause excessive temperature. Use caution in the field against
lightning strikes.
3, do not violently bend the steel needle, do not force pull the sensor leads, do not beat or violently hit the
sensor.
4, sensor protection grade IP68, the sensor can be soaked in water.
5, due to the presence of radio frequency electromagnetic radiation in the air, it should not be in a state of
power in the air for a long time.