10 /12
RS485 Modbus
JXBS-3001-TH--RS Temperature Humidity Sensor User Manual
III. CONFIGURATION TOOL INSTALLATION
We provide CONFIGURATION TOOL , which can be easily used to test our sensor device.
3.1 Sensor Access Computer
Transmitter can be connected to PC with the RS485 to USB adapter. You can check the COM port number
through Device Manager (right click My Computer).
3.2 How To Use Configuration Tool
Please note that this software can only test one device at the same time. After connecting the physical device,
click the CONNECT button to read the information. In the UNCONNET state, you can modify BAUD and ADDR in
COMMUNICATION SETTINGS.
Under the software, different check boxes can be selected according to different situations. For example, you can
choose the GAS option to test the RS485 OXYGEN SENSOR , you can choose the NORMAL option to test the
RS485 TEMPERATURE AND HUMIDITY SENSOR .
ⅣCOMMUNICATION PROTOCOL
4.1 Communication Basic Parameters
TABLE 5 Communication Basic Parameters