Kaipule IX32 User manual

IX32 Wireless Ceiling PIR Detector User Guide
Front Case
Battery Box
(2PCS) Installing Location
Hanging Panel
Back Shell
Infrared Lens
LED Indicator
Jumper Setting
Tamper Switch
X
XX
Expansive Tube
Screw
#5 Battery
1.Take the screw, expansive
tube and 2 pcs #5 battery.
2.Turn over the alarm, anti-clockwisely
rotate the hanging panel,
and remove it.
3. Insert 2 pcs #5 battery in right
polarity. 5.Hold the device in ordinary grip, let the back
hole face to raisedpart of the panel to install,
then clock wisely whirl it the bottom, so the
device can be fixed.
4.Make location hole as picture indicates,
knock the expansive tube in it, use screw
knife to make the screws entering, then
the panel can fix on the wall.
(1)Underline
and make hole
(1)Upward Installation
(2) Insert tubes
(2)Clockwisely Rotation
(3)Fix the panel
2.5~4.0m
Side looking-
Max.6m
Down looking-
360
Detection Range
--1
Ⅰ.Introduction
IX 32 Wireless Ceiling PIR Intrusion Detector, employs digital micro-control
Energy collected process and dynamic random time division technology.
By use of high precision cylindrical Fresnel lens, increase its energy
received efficiency. High sensitivity and accuracy combined with advanced
software technology, make it more effectively detect true invader, or other
competitors that may cause false alarm. Excellent detective and false-less
performance, optional pulse count, completely meets various environments,
reduce potential false alarm possibly, high performance compared to other
competitors, large capacity internal battery. Exclusive power saved solution,
it supports at least 2 years.
Picture 1 External View Picture 2 Internal Structure
Ⅱ.
Specification
Type: IX32
:Detection Distance 6 @ 25m℃
:RF Range 120m
:Input Voltage VDC(2PCS LR 6 1.5V AA Battery)3
Current 5 A Standby 5mA Alarm:≤1 μ ( ) ≤1 ( )
Detection Range:(as diagram )
Optional lens data
Infrared Area:12+12+6
Max. Detection Square:6 diameterm
RF Frequency: 433.92MHz (Default)/868MHz
Alarm Output: LED indicator turns on >3s
Installing Method: Ceiling Mounted
Mounting Height 2 5~4m:.
Operating Temperature: -20 ~50℃℃
Storage Temperature: -20 ~60℃℃
Dimension: (L*W*H)100*100*33.5mm
Ⅲ.Installation
3.1 Installation Guide
3.2 Installation Procedure
Don’t face hot/cold source
Avoid direct sunshine
Wired detector should be away
from high-pressure cable
Installation base should
be stable

FULL Test Mode
PLUS3 3 pulses
NORM Power Save Mode default()
PLUS2 2 pulses
CODE Code Mode
P(LUS1 1pulse default)
Working Mode
Tamper Switch
Pulse Count
Jumper
--2
3 3 Jumper Switch Function.
IX32 can be set 3 types of operation mode:
:Test mode The detector will give an alarm only after 5s when
it was triggered, and send a monitor signal every 15 minutes to
report the status of detector and battery.
:Power save mode When the detector triggered, only after three
minutes can give an alarm again. the detector will send a monitor
signal every 65 minutes to report the status of detector and battery.
Code mode: Press tamper switch for 3 seconds and then release it,
the detector will send an identification code to the receiver.
IX 32 has the following 3 types of pulse optional:
One pulse: The detector gives an alarm when it checks one pulse.
Two pulse: The detector gives an alarm when it checks two pulses.
Three pulses: The detector gives an alarm when it checks three pulses.
The pulse count is higher and the sensitivity is lower, but can reduce
false alarm.
3.4 Replace battery
The detector will send out low battery signal to the control,
then customer should replace the battery. Remove the detector
bottom cover, placed the new battery in right polarity.(As right
picture shows)
Code study setting:
1. Set the detector to normal mode, install batteries rightly, then LED indicator will turn
on. Set the detector to code mode( panel enrolling please refer to relevant User
Manual),during the 3s after panel pressing confirm key to operate:
a. Wave hands in front of the IX 32 detector, the detector will send panel an alarm signal,
if panel gives corresponding voice prompt, means enroll successfully.
b. Trigger the detector tamper switch, the detector will send out an alarm signal, if panel
gives a corresponding voice prompt, means enroll successfully.
2. Enroll code manually by entering address code: Set the panel to manual code study
mode, then enter 9-digit address code tag of the detector, which will be more efficiently
in enrolling.
Ⅳ.Detector code study setting:
1. Set the detector to test mode to perform walking test. Pulse count can be set by PULSE 1,2,3.
2. Walk breadthwise from any direction at the remote detection coverage at the speed of
0.75m/s, then the LED indicator blinks for several seconds and alarm triggered.
3.Test in different direction to confirm the two boundaries of detection. Ensure the detector
rightly points to the central detection zone.
4. The center of detection zone should not uphill inclined. In order to obtain a good detection
range, please adjust the vertical detection range, to ensure the detector is in right position.
5. Perform the walk test again as above when you have adjusted the detection range.
6. When the detector passed the walking test, please adjust the test mode to normal mode.
Please don’t invert the detector while installing. Here advice user to have a walk test every week.
Ⅴ.Walking test in detection area
Our made product are quite stable in performance, but as the product itself transmission limited in bad circumstance
and conditional application, so it still has limited in usage. As the following situations:
1. Panel power voltage unstable
2. Detector power low voltage ,etc.
Warning: If the problems caused by user’s incorrect operation, our company will not be responsible to it!
Ⅵ.Customer Service