Kalse TRIAXIAL ELF SK-8301 User manual

1. Magnetic Flux Density (μT)
Suitable for extremely low frequency magnetic field measurement
from 40Hz to 1kHz.
Two measurement units,μT or mG are selectable.
MAX, MIN and Average measurement are possible.
Quick measurement without connecting any external sensor. Also
provides high portability.
●
●
●
●
Range
20.00μT
200.0μT
Resolution
0.01μT
0.1μT
Maximum Input
Accuracy
±2%rdg±5dgt (50/60Hz)
±5%rdg±5dgt (40Hz to 1kHz) 200.0μT
Range Selection : Auto-ranging
Response Speed : Within 2 seconds
True RMS
True RMS
2. Magnetic Flux Density (mG)
Range
200.0mG
2000mG
Resolution
0.1mG
1mG
Maximum Input
Accuracy
±2%rdg±5dgt (50/60Hz)
±5%rdg±5dgt (40Hz to 1kHz) 2000mG
Range Selection : Auto-ranging
Response Speed : Within 2 seconds
SK-8301
INSTRUCTION MANUAL
FOR SAFETY MEASUREMENTS!!
INTRODUCTION
FEATURES
1. UNPACKING AND INSPECTIONS
To prevent an electrical shock hazard to the operator and/or
damage to the instruments, read this instruction manual carefully
before using the instrument. WARNINGS with the symbol on
the instrument and this instruction manual are highly important.
The symbol listed in IEC 61010-1 and ISO 3864 means
"Caution (refer to instruction manual)".
Important Symbols :
WARNING
CAUTION
The symbol in this manual advises the user of an electrical
shock hazard that could result in serious injury or even death.
The symbol in this manual advises the user of an electrical
shock hazard that could cause injury or material damages.
TRIAXIAL ELF
MAGNETIC FIELD METER
(23℃±5℃、<80%RH in non-condensing)
Thank you for purchasing KAISE "SK-8301 TRIAXIAL ELF MAGNETIC
FIELD METER". To obtain the maximum performance of this
instrument, read this Instruction Manual carefully, and take safe
measurement.
SK-8301 provides accurate magnetic field measurement by its triaxial
sensor and True RMS measurement method.
Confirm if the following items are contained in the package in good
condition. If there is any damage or missing items, ask your local
dealer for replacement.
Children and the persons who do not have
enough knowledge about electric measurements
must not use this instrument.
Do not measure the electricity in naked of
barefooted to protect yourself from electrical
shock hazard.
Keep away the instrument from hot and humid
conditions like inside the car. Do not apply hard
mechanical shock or vibration.
Do not polish the case or attempt to clean it with
any cleaning fluid like gasoline or benzine. If
necessary, use silicon oil or antistatic fluid.
Remove the batteries when the instrument is out
of use for a long time. The exhausted batteries
might leak electrolyte and corrode the inside.
1. Magnetic Field Meter
2. Carrying Case (1015)
3. Batteries (1.5V R6P)
4. Instruction Manual
1 pce.
1 pce.
2 pcs.
1 pce.
2. SPECIFICATIONS 3. SAFETY PRECAUTIONS 4. NAME ILLUSTRATION
2-1. GENERAL SPECIFICATIONS
DISPLAY (LCD)
a. Numerical Display : 2000 count, Maximum reading 2000, 15mm high
b. Units and Symbols :
OPERATING PRINCIPLE : Triaxial True RMS (X, Y, Z)
SAMPLING RATE : 2 times/second
RANGE SELECTION : Auto-ranging
MEASUREMENT UNIT : μT/mG (selectable when turn the power on)
OVERLOAD INDICATION : "OL" indication when exceeding 2000 count
BATTERY WARNING : indication at approx. 2.3V±0.15V or less
DISPLAY HOLD : Hold indicating values by DH Key
MAX/MIN/AVERAGE : Measurable by REC Key
AUTO POWER OFF : Power turns off automatically after approx.
30 minutes. (in normal measurement mode / cancelable)
OPERATING POWER SUPPLY VOLTAGE : 2.3V to 3.6V
OPERATING TEMPERATURE & HUMIDITY : 0℃to 40℃, 80%RH
or less in non-condensing
STORAGE TEMPERATURE & HUMIDITY : -20℃to 60℃, 70%RH
or less in non-condensing
TEMPERATURE COEFFICIENT : Accuracy at 23℃±5℃×0.1/℃
SAFETY LEVEL : CE marking approved (IEC-61010-1, CAT I 600V
and EMC Test passed.)
POWER SUPPLY : 1.5V R6P or LR6 (AA) batteries x 2
CURRENT CONSUMPTION : Approx. 20mA (less than 100μA in
auto power off and power-off conditions)
CONTINUOUS OPERATING TIME : Approx. 100 hours (alkaline),
Approx. 50 hours (manganese)
DIMENSIONS & WEIGHT : 148(H)×83(W)×33(D)mm, Approx.
220g (including batteries)
ACCESSORIES : 1015 Carrying Case, 1.5V R6P (AA) batteries x 2,
Instruction Manual
, , MAX, MIN, AVG, μT, mG, ,
AUTO,
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
2-2. MEASUREMENT SPECIFICATION
FREQUENCY CHARACTERISTIC EXAMPLE
WARNING 1. Checks of the Instrument
WARNING 2. Strong Magnetic Field
WARNING 3. Electrical Shock
WARNING 4. Measurable Frequency Range
WARNING 5. Maximum Input Observance
Correct knowledge of electric measurements is essential to avoid
unexpected danger such as operator's injury or damage to the instrument.
Read the following precautions carefully for safety measurements.
Extremely strong magnetic field could be generated depending on
the electromagnetic sources.
Do not touch the instrument on voltage generated circuit or any other
parts. It might cause electrical shock hazard that could result in serious
injury or even death.
Do not measure any magnetic flux density that might exceed the
specified maximum input value.
Measurable frequency range of this instrument is 40Hz to 1kHZ.
Measurement out of this range should be incorrect, and may not
detect the strong magnetic field which is dangerous for the person
who with implant electronic devices such as pacemaker.
Be careful not to get out of safety zone or safely marking area.
The person who with implant electronic devices such as pacemaker
should avoid any dangerous area.
Be careful about displayed measurement values when approaching
uncertain magnetic field sources.
1.
2.
3.
3-1. WARNINGS
3-2. GENERAL WARNINGS AND CAUTIONS
Before measurement, check if there is no damage to the instrument.
Dust, grease and moisture must be removed.
WARNING 1.
WARNING 2.
CAUTION 1.
CAUTION 2.
CAUTION 3.
a. Power ON/OFF
Press this key for 0.5 seconds or less to turn on. To turn off, press it
for 2 seconds or more.
b. Changing Measurement Units
Turn on the instrument holding down DH Key. Measurement unit is
changed into another one, either μT or mG.
NOTE : Factory default setting is "μT".
NOTE :
4-2. POWER Key
Holds displayed value on LCD by pressing this key for 0.5 seconds or
less. (" " lights up)
To release it : Press DH Key again for 0.5 seconds or less.
4-3. DH Key : Display Hold
Press this key for 0.5 seconds or less to start MAX, MIN and Average
measurements (" " lights up). To view each value, press this key
for 0.5 seconds or less during MAX/MIN/AVERAGE measurement.
To return to normal measurement mode : Press REC Key for 2
seconds or more.
※For details of this function, read "5-3. MAX/MIN/AVERAGE
Measurement".
4-4. REC Key : MAX/MIN/AVERAGE measurement
Triaxial sensor is incorporated inside of the X, Y, Z mark.
When measuring, put this mark almost under the magnetic field
source.
4-5. Sensor
DH Key
POWER Key
4-1. LCD
AUTO
MAX
MIN
AVG
Auto-ranging measurement
Lights up in display hold function
Low battery warning
Lights up in MAX/MIN/AVERAGE measurement
Lights up when maximum value is displayed
Lights up when minimum value is displayed
Lights up when average value is displayed
Lights up when auto power off is activated
Lights up in mG measurement
Lights up in μT measurement
:
:
:
:
:
:
:
:
:
:
Fig. 1
Fig. 2
SK-8301
TRIAXIAL ELF
MAGNETIC FIELD METER
Y
X
Z
REC DH
DISPLAY
HOLD POWER
MAX/MIN
AVG
LCD
REC Key
Sensor
The changed measurement unit is displayed from the next
power-on.
0.0
-5.0
-10.0
-15.0
-20.0
1 10010
Frequency [Hz]
100001000
Gain [dB]
- 1 - - 2 - - 3 - - 4 -

- 5 - - 6 - - 7 - - 8 -
Turn on the instrument holding down REC Key. Auto
power off is disabled and " " disappears from LCD.
Check the battery connection, polarity, and capacity (" " lights up
or not).
Confirm that the keys are set correctly.
Confirm that measured accuracy is adopted in the operating
environment.
Confirm that the body of this instrument has no cracks or any
other damages.
Replace the batteries when " " lights up on LCD.
Press REC Key for 0.5 seconds or less during normal measurement.
" " lights up on LCD and starts MAX/MIN/AVERAGE measurements.
NOTE : Auto power off is cancelled in this function.
Press REC Key for 0.5 seconds or less to view MAX, MIN, and
Average values.
"MAX" (maximum value) →"MIN" (minimum value) →"AVG"
(average value) are displayed on LCD each time the key pressed.
To return to MAX/MIN/AVERAGE measuring mode, press REC Key
for 0.5 seconds or less in "AVG" display.
To return to the normal measurement mode, press REC Key for 2
seconds or more. MAX/MIN/AVERAGE measurement is finished
and " " disappears from LCD.
NOTE :
NOTE :
Power turns off automatically after approx. 30 minutes of the last key
operation.
NOTE : Approx. 100μA is consumed even in the power-off condition.
NOTE :
To cancel it :
Before starting measurement, install 2 pcs of 1.5V R6P or LR6
batteries referring to "6-1. BATTERY REPLACEMENT". Replace them
in the same way when " " lights up on LCD.
5-3. MAX/MIN/AVERAGE MEASUREMENT
Fig. 4
Start
MAX/MIN/AVERAGE
measurement
lights up
MAX/MIN/AVERAGE MEASUREMENT EXAMPLE
REC Press (0.5 seconds or less)
Maximum value
display
MAX lights up
REC Press
(0.5 seconds or less)
Minimum value
display
MIN lights up
Average value
display
AVG lights up
Fig. 5
70-1201-8301-1 0904
WARNINGS
Do not touch the instrument on voltage generated circuit or
any other parts. It might cause electrical shock hazard that
could result in serious injury or even death.
Extremely strong magnetic field could be generated depending on
the electromagnetic sources. Read "3. SAFETY PRECAUTIONS"
carefully before starting the measurement.
Frequency range to be measured is 40Hz to 1kHz. Measurement
out of this range should be incorrect.
Do not measure any magnetic flux density that might exceed
the specified maximum input value.
●
●
●
●
Periodical check and calibration is necessary to make safety
measurements and to maintain the specified accuracy. The
recommended check and calibration term is once a year and after the
repair service. This service is available at KAISE AUTHORIZED
SERVICE AGENCY through your local dealer.
6-2. PERIODICAL CHECK AND CALIBRATION
6-3. REPAIR
Repair service is available at KAISE AUTHORIZED SERVICE AGENCY
through your local dealer. Pack the instrument securely with your
name, address, telephone number and problem details, and ship
prepaid to your local dealer.
Caution (refer to instruction manual.)
CE Marking Conformity
3.
4.
5.
Fig. 3
Y
X
Z
SK-8301
TRIAXIAL ELF
MAGNETIC FIELD METER
Y
X
Z
REC DH
DISPLAY
HOLD POWER
MAX/MIN
AVG
Put sensor part, marked X, Y, Z, directly under the
magnetic field source. Or, put this part close to
the object to be measured.
-+
1.5V R6P
-+
1.5V R6P
Battery Cover
-+
1.5V R6P
+
Two 1.5V R6P Batteries
Screw
Pull the screw when the battery cover
is hard to be opened.
5-2. MAGNETIC FLUX DENSITY MEASUREMENT
(μT / mG)
Read INSTRUCTION MANUAL carefully to understand the specification
and functions properly. "3. SAFETY PRECAUTIONS" is very important
for safety measurement.
1. INSTRUCTION MANUAL
2. BATTERY INSTALLATION
4. AUTO POWER OFF
LCD displays "OL" if measurement value exceeds 2000 count.
3. OVERLOAD INDICATION
5. SYMBOL MARK
Press POWER Key for 0.5 seconds or less and turn on the instrument.
Confirm if the appropriate measurement unit, μT or mG is
displayed on the LCD.
Measurement unit can be changed by the following procedures.
How to change the measurement unit :
1)
2)
3)
1.
2.
The following symbol marks shown on the instrument and instruction
manual are listed in IEC 61010-1 and ISO 3864.
5. MEASUREMENT PROCEDURES
5-1. PREPARATION FOR USE
The changed measurement unit is displayed from the
next power-on.
Turn off the instrument by pressing POWER Key for 2 seconds
or more.
Hold down DH Key and press POWER Key for 0.5 seconds or less.
The instrument turns on again and another measurement unit is
displayed on LCD.
NOTE : Factory default setting is "μT". (1μT = 10mG)
NOTE :
Put sensor part, marked X, Y, Z, directly under the magnetic field
source. Or, put this part close to the object to be measured.
NOTE :
Read the measurement value on LCD.
After finishing the measurement, turn off the instrument by
pressing POWER Key for 2 seconds or more.
Triaxial sensor can take the measurement regardless of
the instrument direction. Measurement from front, side,
or any direction is possible.
Available Functions :
MAX/MIN/AVERAGE Measurement (refer to 5-3), Display Hold (refer
to 4-3)
KAISE AUTHORIZED DEALER
1.
2.
3.
4.
Check the following items before asking repair service.
1.
2.
3.
4.
MAX, MIN and Average measurement are possible by using REC Key.
Auto power off is reactivated after returning to the normal
measurement mode.
The instrument does not memorize MAX, MIN and
Average values after finishing this function.
REC Press
(0.5 seconds or less)
REC Press
(0.5 seconds or less)
REC Press
(0.5 seconds or less)
5. MAINTENANCE
6-1. BATTERY REPLACEMENT
WARNING
To avoid electrical shock, stop measurement and turn off the
instrument when to replace battery.
1.
2.
3.
4.
5.
NOTE : Remove the batteries when the instrument is out of use for a
long time. The exhausted batteries might leak electrolyte and corrode
the inside.
Stop measurement and turn off the instrument.
Loosen a screw of battery cover and open it.
NOTE : Pull the screw when the battery cover is hard to be opened.
Remove the exhausted batteries.
Insert 2 pcs of new 1.5V R6P or LR6 batteries in correct polarity.
Fix battery cover and tighten the screw.
SK-8301 is warranted in its entirety against any defects of material or
workmanship under normal use and service within a period of one year from the
date of purchase of the original purchaser. Warranty service is available at KAISE
AUTHORIZED SERVICE AGENCY through your local dealer. Their obligation under
this warranty is limited to repairing or replacing SK-8301 returned intact or in
warrantable defect with proof of purchase and transport charges prepaid. KAISE
AUTHORIZED DEALER and the manufacturer, KAISE CORPORATION, shall not
be liable for any consequential damages, loss or otherwise. The foregoing
warranty is exclusive and in lieu of all other warranties including any warranty of
merchantability, whether expressed or implied.
This warranty shall not apply to any instrument or other article of equipment which
shall have been repaired or altered outside of KAISE AUTHORIZED SERVICE
AGENCY, nor which have been subject to misuse, negligence, accident, incorrect
repair by users, or any installation or use not in accordance with instructions
provided by the manufacturer.
WARRANTY
Product specifications and appearance are subject to change without notice due to continual improvements.
422 Hayashinogo, Ueda City, Nagano Pref., 386-0156 Japan
TEL : +81-268-35-1601 / FAX : +81-268-35-1603
Auto power off is cancelled under MAX/MIN/AVERAGE
measurement.
Other Kalse Measuring Instrument manuals