Kanmor 506 Series User manual

1 of 4 © 2005 U 506x - 12/05
U506x
12/05
Thermostat 506x
- User Brochure
Table of Contents
Display.............................................................. 1
Symbol Description........................................... 2
User Interface................................................... 2
View the Temperatures..................................... 2
Adjust the Temperature Settings ...................... 3
Night Setback Operation .................................. 4
Select a Manual Override................................. 4
Error Messages ................................................ 4
Cleaning the Thermostat ................................. 4
Warranty ........................................................... 4
Features:
•
• Large Multilingual Display
•
• Remote Air Sensing
•
• Manual Override
•
• Floor Heating
•
• Night Setback
•
• Backlight
Display
Item Field
Displays an abbreviated
name or symbol of the
selected item
Number Field
Displays the current value
of the selected item
Status Field
Displays the current
status of the control’s
inputs, outputs and
operation
Menu Field
Displays the
current menu

© 2005 U 506x - 12/05 2 of 4
The thermostat has 3 menus:
View - view the measured temperatures
Adjust - adjust the operating temperatures
Schedule - select a manual override
User Interface
View the Indoor Temperature
If an indoor sensor is active:
View the Temperature
If a floor sensor is installed:
View the Outdoor Temperature
If an outdoor sensor is installed:
View the Temperatures
Symbol Description
OFF
Thermostat is in the off mode of
operation.
INSTALLER / USER
A padlock is shown while in the user
access level.
WARNING
Shown when an error message is
present.
INDOOR TEMPERATURE
Shown together with the measured
indoor air temperature.
SLEEP
Shown while operating at the sleep
temperature.
EXTERNAL NIGHT SETBACK
Shown when external night setback
signal is present.
HEAT
Thermostat is in the heating mode of
operation.
MANUAL OVERRIDE
Shown when an override is manually
selected.
OUTDOOR TEMPERATURE
Shown together with the measured
outdoor temperature.
INDOOR TARGET
Shown together with the desired indoor
air temperature.
WAKE
Shown while operating at the wake
temperature.
HEAT CONTACT
Shows when the heat contact is
closed.
•
• To change the Indoor Target: Press the up or down
button.
•
• To change the FLOOR MIN when there is no Indoor
temperature: Press the up or down button.
•
• Press the Menu button to change the menu.
•
• Press the Item button to advance to the next item
within a menu.
•
• Press the up or down button to change the setting.

3 of 4 © 2005 U 506x - 12/05
Adjust the Temperature Settings
Adjust the of Operation
Step 2 Adjust the Indoor Target Temperature
If an indoor sensor is active:
Step 3 Adjust the Temperature
If a floor sensor is active:
Step 4 Adjust the Temperature Units°C /°F
•
• Press the up or down button to select between
‘OFF’ or ‘HEAT’.
•
• Press the up or down button to permanently
adjust the Indoor Target temperature.
•
• Wake is the normal operating temperature.
•
• Sleep is the operating temperature while a night
setback signal or manual override is present.
Wake
Sleep
•
• Press the up or down button to permanently
adjust the Floor Minimum temperature.
•
• Wake is the normal operating temperature.
•
• Sleep is the operating temperature while a night
setback signal or manual override is present.
•
• Select either °C or °F.
•
• Press the up or down button to change.
or
or
or
or
Wake
Sleep
•
• Press the menu button to enter the Adjust menu.
•
• Adjust menu allows changes to the temperatures.
Step 1 Enter the Adjust Menu

© 2005 by tekmar Control Systems Ltd. Used with permission.
kanmor trademark is used under license. 4 of 4 All specifications are subject to change without notice.
Printed in Canada. U 506x - 12/05.
kanmor Control Systems Ltd.
5100 Silver Star Road
Vernon, B.C. CANADA V1B 3K4
250-545-2693 Fax. 250-549-4349
Web Site: www.kanmor.com
Limited Warranty and Product Return Procedure
Limited Warranty The liability of kanmor Control Systems Ltd.
(“kanmor”) under this warranty is limited. The Purchaser, by taking
receipt of any kanmor product (“Product”), acknowledges the terms
of the Limited Warranty in effect at the time of such Product sale and
acknowledges that it has read and understands same.
The kanmor Limited Warranty to the Purchaser on the Products sold here-
under is a manufacturer’s pass-through warranty which the Purchaser is
authorized to pass through to its customers. Under the Limited Warranty,
each kanmor Product is warranted against defects in workmanship and
materials if the Product is installed and used in compliance with kanmor’s
instructions, ordinary wear and tear excepted. The pass-through warranty
period is for a period of twenty-four (24) months from the production date
if the Product is not installed during that period, or twelve (12) months
from the documented date of installation if installed within twenty-four (24)
months from the production date.
The liability of kanmor under the Limited Warranty shall be limited to, at
kanmor’s sole discretion: the cost of parts and labor provided by kanmor to
repair defects in materials and/or workmanship of the defective product; or
to the exchange of the defective product for a warranty replacement product;
or to the granting of credit limited to the original cost of the defective product,
and such repair, exchange or credit shall be the sole remedy available
from kanmor, and, without limiting the foregoing in any way, kanmor is not
responsible, in contract, tort or strict product liability, for any other losses,
costs, expenses, inconveniences, or damages, whether direct, indirect,
special, secondary, incidental or consequential, arising from ownership or
use of the product, or from defects in workmanship or materials, including
any liability for fundamental breach of contract.
The pass-through Limited Warranty applies only to those defective Prod-
ucts returned to kanmor during the warranty period. This Limited Warranty
does not cover the cost of the parts or labor to remove or transport the
defective Product, or to reinstall the repaired or replacement Product, all
such costs and expenses being subject to Purchaser’s agreement and
warranty with its customers.
Any representations or warranties about the Products made by Purchaser to
its customers which are different from or in excess of the kanmor Limited War-
ranty are the Purchaser’s sole responsibility and obligation. Purchaser shall
indemnify and hold kanmor harmless from and against any and all claims,
liabilities and damages of any kind or nature which arise out of or are related
to any such representations or warranties by Purchaser to its customers.
The pass-through Limited Warranty does not apply if the returned Product
has been damaged by negligence by persons other than kanmor, accident,
fire, Act of God, abuse or misuse; or has been damaged by modifications,
alterations or attachments made subsequent to purchase which have not
been authorized by kanmor; or if the Product was not installed in compli-
ance with kanmor’s instructions and/or the local codes and ordinances; or
if due to defective installation of the Product; or if the Product was not used
in compliance with kanmor’s instructions.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO
CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION,
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE
PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS
OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLA-
TION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY
LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY
CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT
EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUC-
TION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY
THE GOVERNING LAW.
Product Warranty Return Procedure All Products that are believed to
have defects in workmanship or materials must be returned, together with
a written description of the defect, to kanmor through its Representative. If
kanmor receives an inquiry from someone other than a kanmor Represen-
tative, including an inquiry from Purchaser (if not a kanmor Representative)
or Purchaser’s customers, regarding a potential warranty claim, kanmor’s
sole obligation shall be to provide the address and other contact informa-
tion regarding the appropriate Representative.
Cleaning the Thermostat
The thermostat’s exterior can be cleaned using a damp cloth. Moisten the cloth with water and wring out prior to wiping
the thermostat. Do not use solvents or cleaning solutions.
Error Messages
When the thermostat encounters a sensor problem, a
Warning Symbol together with a description appears on
the display. To correct the error, please refer to the Data
Brochure or contact a qualified installer.
Night Setback Timer Operation
When an external control with a timer is installed, the thermostat night setback can be activated. When the timer signal
is received, a time clock symbol appears. The thermostat now operates at the sleep temperature.
Select a Manual Override
•
• When the manual override is set to ‘On’, the thermostat
operates at the sleep temperature.
•
• Press the up or down button to set to ‘On’.
•
•
The override remains until it is manually changed to ‘OFF’.
Other Kanmor Thermostat manuals
Popular Thermostat manuals by other brands

Signature
Signature TSTSC operating instructions

Neomitis
Neomitis RTMA Installation and operating instructions

Cosa
Cosa Alarko C4D0-5V/Bat Installation and user manual

Danfoss
Danfoss ECL Comfort 210 installation guide

Purmo
Purmo TempCo Comfort 24V user manual

ensto
ensto ECO16TOUCH Installation and operating instructions