Karat AC User manual

Product installation and operation manual
KARAT
URINAL SENSOR

Thank you for your insight in choosing our urinal flushing sensor. I believe you
will be immensely pleased after choosing it. From now on, you become a guest
of our company. We are ready to provide you with high-quality services. In order
to ensure that this product can give full play to its unique performance and pro-
long its service life, We advise you to read the following content before use to
ensure that you can use this product normally.
The urinal flush sensor is carefully designed based on the principle of infrared
induction. It integrates the quality of bureau technology. It has the following ad-
vantages:
1. Intelligence: automatic sensing, which can distinguish whether the user is
using the urinal and make a judgment to flush.
2. Automaticity: the user does not need to take any action within the sensing
range of the urination sensor to realize flush automatically.
3. Hygiene: the function of flushing urinal can be achieved without getting close
to the appliance, which is convenient and hygienic and Effectively eliminate
cross infection of bacteria.
4. Applicability: the product has beautiful appearance, simple and convenient
installation, and is suitable for all kinds of new construction sites and refitting of
old projects.
II Product performance parameters
I Product functions and characteristics
Model AC DC AC/DC
Power
Power supply
Nominal diameter
Ambient
temperature
Induction time
Flushing volume
Induction distance
Applicable water
pressure
Working:≤4W
Standby:≤2W
Working:≤4W
Standby:≤2W
Standby:≤0.2mW
DC6V AC220V/50Hz DC6V
AC220V/50HZ
Start the device after induction for more than 3 seconds, two-stage flushing
Under static water pressure 0.17 ± 0.01Mpa: flushing volume ≤3L per cycle
55cm, subject to the test of 297mmx297mm wood pulp copy paper
G1/2" (DN15)
0.05~0.6MPa
1-55℃
III Product structure diagram
(The picture is for reference only, and the real object shall prevail)
Battery box
(only for DC) G1/2”
inlet G1/2”
G1/2”
inlet G1/2” G1/2”
inlet G1/2”
Filter
regulating
valve
Filter
regulating
valve
Manual
button
Solenoid valve
without button Solenoid valve
with button
Power
supply Power
supply
Host machine
box
Host
machine
box
Coil
Outlet Coil
Outlet
Automatic model Manual automatic
all-in-one model
KARAT URINAL SENSOR

IV Parts and fittings of the machine
G1/2”
inlet G1/2”
G1/2”
inlet G1/2”
Host machine box
Protection box
Host machine box
nfrared
induction eye
Panel
face frame
(only for the
machine with
manual flush
button)
Manual button
Integrated pane
fixed bracket
(to match the integrated panel)
Assembly of mechanical button
framed panel
face frame
(to match the framed panel)
Solenoid valve
Protection box
Solenoid valve with button
AC power supply
Elbow
(inlet accessory for
top inlet machine)
decorative cup
(accessory for
top inlet machine)
Host machine box
工 shaped rubber L shaped pipe
DC battery box
(AC / DC standby power supply)
KARAT URINAL SENSOR

V Description of installation steps
Quarter nut Flat rubber pad hose
(for the machine
with back inlet)
1 Installation diagram of machine with top inlet
2 Installation diagram of machine with back inlet
The front diagram
The front diagram
Reserved hole for
host machine box
urinal
urinal
Ground
side diagram
side diagram
Depth of wall excavation 90mm
Depth of wall excavation 90mm
The ceramic tile surface shall not be
lower than the top surface of the
protective box
The ceramic tile surface shall not be lower than
the top surface of the protective box
finished wall
finished wall
Urinal
Urinal
Ground
Ground Ground
Adults 550/ Kids 380
Adults 550/ Kids 380
Reserved hole for
host machine box
Unit: mm
Central position of the host machine box
The joint of
back inlet
metal hose
The position of
urinal inlet
265 to 330
KARAT URINAL SENSOR

3 installation steps
1.Wall excavation and water pipe laying
water inlet channel
Groove for host machine
water outlet slot
waster draining slot
branch pipe water supply pipe
draining pipe of urinal
Reserve the slots of the host machine box of the sensor, the water inlet and outlet pipes, and
the drainage pipe of the urinal according to the size of the installation diagram. and reserve
the position of installing the urinal; Open the groove and slots and lay the pipes after posi-
tioning the installation.
2.Flushing pipeline 3.installation of the host machine
the sealing ring
needs to be put into
the union
the sealing ring must be
placed in the union. After
installation, open the water
source to confirm that
there is no water leakage,
and then proceed to the
next installation work.
protect the urinal
before flushing the
pipe to prevent debris
from flushing into the
urinal and causing
blockage
Note:
Note:
Note:
Note:
the sealing ring needs to
be put into the union
Screw the union at the end
of the host machine
marked with water inlet
onto the prepared water
inlet pipe
Screw the metal hose onto
the water outlet connector
of the host machine
(The product has been
equipped with sealing rings
when leaving the factory)
4.Install elbow or water outlet connector
1)Top water inlet method: install elbow 2)Back water inlet mode: install metal hose
Screw the elbow with
union(G1/2”) to
the water outlet of
the host machine
KARAT URINAL SENSOR

Note:
Note:
5.Power line connection
protective box
host machine box
wire
cover of battery box
battery box
preparing
battery wiring
1.Remove the protective box
2.AC type: connect the reserved wire on the host
power box with 220V power supply, and tie the
wire head with electrical tape
3.Direct waste type: take out the DC battery box,
remove the cover, install four No. 5 dry batteries
in the direction, and install the battery box cover
into the host machine after tightening it
4.AC / DC type: install the AC power supply and
DC power supply at the same time according to
the above method.
5.Connect all butt joints
(As shown in the left figure)
6.Gap filling, tiling, urinal installation
1.Installation method of top water inlet
2.Back water inlet installation mode
ceramic tile
protective box
Connect to
the elbow
Install the protective
box, fill the gap with
cement and paste
tiles
the ceramic tile surface
cannot be lower than
the top surface of the
protective box
Water outlet joint
Bevel nut
L shaped elbow
Decorative cup
I-shaped glue
urinal
Installation steps
a. Insert the I-shaped glue into the lower
nozzle of the urinal
b. Put the decorative cup on the elbow
c. Insert the L shaped elbow into the
I-glue
d. Fix the splay elbow on the water outlet
joint with a beveled nut
e. Cover the decorative cups respec-
tively
Bevel sealing ring should be put into
bevel nut
branch pipes supply pipe
host machine box
metal hose
urinal draining pipe
Install the protection box after connecting the wires and
circuits. Fill the gap with cement.The channel containing
the metal hose cannot be filled with cement,as the
metal hose should be able to stretch freely.
KARAT URINAL SENSOR

Note:
Note:
ceramic
tiles
ceramic
tiles
ceramic
tiles
host
machine
box
metal hose
draining pipe
2. Wall tiles: Only metal hose joints
and drain pipe joints that can be
freely retracted are reserved
The slot of metal hoses cannot be filled
with cement. The ceramic tile surface
shall not be lower than the top surface of
the protective box.
The ceramic tile surface shall
not be lower than the top
surface of the protective box
ceramic tile wall
No filler
Metal hose
back water inlet joint
wall
urinal urinal
draining
pipe
protective
box
ceramic tiles ceramic tiles
3. Connect the metal hose firmly with the water inlet connector behind the urinal.
4. Hang and secure the urinal, and insert the drain into the reserved groove.
1. Before installing and connecting the sensor host, be sure to wash the sundries in the water
pipe to prevent blocking the solenoid valve filter screen;
2. A sealing ring shall be placed in each connector to prevent water leakage.
KARAT URINAL SENSOR

ceramic
tile wall
ceramic
tile wall
ceramic
tile wall
protective
box
7. Installation of main control panel
1. Installation method of framed panel
Screwdriver
panel
face frame
face frame
face frame
face frame
nduction eye
nduction eye
sucker
Plug in wire
induction eye
face frame
manual button
Only for the machine
with manual button
Screwdriver
1. Unscrew the two screws on the protection box with a screwdriver and take out the protective box after
the main machine is put into the wall according to the installation requirements and the wall is tiled.
2. Suck it with a sucker or gently push it straight from the back with your hand to remove the stainless
steel panel sucked on the face frame.
3. Connect the black male plug of the electric eye with the black female plug of the solenoid valve. Con-
nect the red male plug of the power supply or battery box with the red female plug of the electric eye. (for
AC and DC products, the red male plug of the battery box is connected with the red female plug of the
power supply).
4. Put the face frame on the installation position of the wall, then put four M4*40 machine screws through
the mounting holes on the four corners of the face frame and face the screw holes on the main box.
Tighten the screws with a screwdriver to make the face frame firmly installed without loosening.
5. After fixing the face frame, place the stainless steel panel on the corresponding position of the face
frame. Let the magnet on the face frame tightly attract it, so that it cannot loose and fall.
KARAT URINAL SENSOR

2. Other panel installation methods
surface panel
panel
Stainless steel panel
Curved panel
Filter strip
1. Unscrew the fixing screws on the filter strip and remove the
filter strip.
2. Connect the induction eye and the power pair wiring in the
main box.
3. Align the two mounting holes on the panel with the two
mounting holes in the middle of the host bottom box, and then fix
the panel on the host bottom box with m4x40mm round head
screws.
4. Install the filter strip back on the panel and fix it with
m2.5x6mm screws
1) Suck out the stainless steel panel on the face frame with a suction
cup.
2) Connect the electric eye and the power pair wiring in the main box
3) Align the two mounting holes on the face frame with the two mounting
holes in the middle of the host bottom box, and then fix the face frame
on the host bottom box with m4x40mm round head screws.
4) Install the stainless steel panel
1.Put the fixing bracket into the wall hole and lock it with the main box
with m4*40 machine thread
2.Plug the red and black plugs of the electric eye on the panel into the
corresponding plugs of the host respectively (for AC and DC products,
the red plug of the battery box in the host box is connected with the red
plug of the power supply)
3.Insert the spring at the bottom of the panel into the hook of the fixed
support, and then press and push the panel into the upper slot of the
support
panel installation
wiring
Mounting bracket
KARAT URINAL SENSOR

VI Instructions
Note:
8.Installation completed
panel
panel
urinal urinal
ceramic tiles ceramic tiles
after installation, check the connec-
tion of the power line, and then have
several times try to flush water.
1.Operation method
2.Precautions for operation
1) When the user enters the sensing area, the sensor will conduct the first stage of pre flushing
after sensing for 3 seconds, and then the sensor will be effective after sensing for 3 seconds.
When the user leaves the sensing area for 3 seconds, the second stage of cleaning and
flushing will be carried out (this flushing time can be set by the remote control within 2 seconds
to 15 seconds); If users use it continuously within one minute, the first stage of pre flushing will
not be carried out, and only the second stage of cleaning and flushing will be carried out after
the user leaves (environmental protection and water-saving design). The sensor will be auto-
matically cleaned and flushed once without being used for 24 hours. The sensing distance of
the sensor can be adjusted within the range of 30cm to 80cm; The factory default sensing
distance is set to 55cm.
2) For products with manual pressing function, the users can push the manual button to flush
the urinal when the AC power supply is cut off or the DC battery is exhausted, or other abnor-
malities occur leading to the automatic induction failure.
1)In order to avoid the possibility of failure, do not install the product in front of stainless steel
walls and other high-strength reflective surfaces or other infrared sensors.
2)If you need to use it in special environments such as dark black clothes with high intensity
reflection or easy absorption of infrared rays, please consult the supplier to choose anti color
difference sensor products to achieve the best effect
KARAT URINAL SENSOR

VII Function adjustment
Note:
Note:
3. The standby power supply of DC products and AC / DC products must be replaced
with a new dry battery after the power is exhausted (as shown in the figure below)
3)If there is dirt in the induction eye window, please clean it in time to avoid affecting the use
effect.
4)If you find that the use effect is not good during use, please operate according to "VII:
function adjustment"
5)If you find that the flushing water is insufficient during use, please clean the filter.
6) For DC type (dry battery) products, when the dry battery voltage is lower than about 4.5V,
the indicator light will be red when the sensor eye has induction, indicating that the dry battery
voltage is insufficient and the battery needs to be replaced.
7) If you find that the AC type urinal flushing sensor is not inductive or the power supply is in
poor contact, please turn off the power immediately and find relevant professionals for mainte-
nance to avoid electric shock or other accidents.
battery box
Battery box cover
No.5 dry battery rack
when replacing dry batteries, correctly install four 1.5V
alkaline No. 5 dry batteries into the battery rack according
to the "+" "-" mark on the battery rack, then put the battery
rack into the battery box and fasten the cover of the battery
box. Old and new batteries cannot be mixed.
Remove the panel and adjust the function according to the installation method of the panel.
1. Water volume adjustment
Adjust water consumption .Firstly remove the panel and
adjust the regulating valve with a "straight" screwdriver
(as shown in the figure). Turn left to increase the water
volume and right to decrease water volume. (some types
of panels need to remove the lower frame before using
the screwdriver to adjust the regulating valve, and the
adjustment method is the same)
KARAT URINAL SENSOR

VIII Maintenance and precautions
2. Adjustment of sensing distance and flushing time
1. Cleaning
2. Clean the filter
3. It is strictly forbidden to wash with water directly
4. Do not use corrosive cleaners
The sensing distance and flushing time of urinal flushing sensor have been set to the best use
state when leaving the factory. If you need to change it, you can use a special remote control to
adjust it. For details, please consult the customer service center or dealer of the company
If there are obstacles or dirt in front of the induction
window that will affect the normal induction, the
obstacles must be cleared and the induction window
must be cleaned in time
Adjust the regulating valve to turn off the water
source with a "-" screwdriver, unscrew the filter,
clean it with a toothbrush, and then re-install it.
Since the host machine contains electronic control
circuits, it is strictly forbidden to wash the surface
directly with water to prevent accidents
Do not use corrosive cleaners so as not to damage
and affect the appearance when cleaning applianc-
es,because plastic or stainless steel products are
used for panels and induction windows.
KARAT URINAL SENSOR

IX Simple fault analysis and elimination
When the sensor has the following appearance, it may not be caused by appliance failure.
Please analyze and eliminate them according to the following table.
Appearance
No water
Cause Inspection and analysis Elimination
No stop
of water
Small
amount
of water The opening of regulat-
ing valve is too small
Impurities in the solenoid
valve
Check whether there is
normal power supply to
the sensor
AC type: connect the
power supply
DC type: replace the
battery
Filter clogged
Filter clogged
Poor connector contact
Abnormal sensing
distance Whether to adjust
Whether it is loose
or not connected
Abnormal water supply Check the water source Turn on the water supply
Adjust with remote control
Tighten all connectors
Clean the filter
Cleaning solenoid valve
Clean the filter
Adjust the regulating valve
counterclockwise
Abnormal power supply
Matters needing attention
In case of failure in operation, please refer to "simple fault analysis and
elimination" for inspection and maintenance. When the fault cannot be
eliminated, it is not recommended that the customer dismantle the
components and parts for maintenance without authorization. Contact
the customer service center or dealer to arrange professionals for
maintenance.
KOHLER ASIA PACIFIC LIMITED
Address: 14/F, No.88 Gloucester Road, Wanchai, Hong Kong
KARAT URINAL SENSOR
This manual suits for next models
2
Table of contents
Popular Security Sensor manuals by other brands

Summit Treestands
Summit Treestands Seat-O-The Pants instructions

GEV
GEV LBB 18235 manual

Interlogix
Interlogix EV520-P Series Installation sheet

Optex
Optex WX Shield Series installation instructions

Analog Devices
Analog Devices ADIS16407 manual

Tie Down Engineering
Tie Down Engineering Roof Zone 13809 installation instructions

Optex
Optex inSight INS-HX-80N installation instructions

Elkron
Elkron DC600S Installation, programming and functions manual

PCB Piezotronics
PCB Piezotronics 8162-055A Installation and operating manual

Samotech
Samotech SM301Z user manual

Servodan
Servodan niko 41-720 user manual

Tyco
Tyco Visonic TOWER-30AMPG2 installation instructions