1. Remove all packaging material
2. Attach network and coaxial video cables as
required.
3. Set DIP switches as required.
4. Attach power to the 5Vdc power jack.
Note: for rack mount configuration see product
manual or EE1R3 Quick Start Guide.
LED Status Description
PWR ON Power is supplied to the unit
OFF No power to the unit
VDSL ON The VDSL link is established
FAST The VDSL link is being
established – approx. 10 sec.
SLOW No VDSL connection
CO ON Unit in Central Office (CO) mode
CPE ON Unit in Customer Premises
Equipment (CPE) mode
Ethernet RJ45 Port Status LEDs - TP
LNK ACT
ON Effective network connection has
been established for the port
FLASH
Data traffic is passing through
the port
OFF No effective network connection
has been established for the port
100
ON Port operating at 100Mbps
OFF Port operating at 10Mbps or a
link is not established
DIP Switch Settings
mode
Office (CO)
(default)
Premises
Equipment
(CPE)
Note: when the unit is set to CPE mode D P switches 2, 3
& 4 have no function.
Troubleshooting