INSTALLATION INSTRUCTIONS
F-2257-091118
Task Lighting
IMPORTANT SAFETY PRECAUTIONS
STRATALUME CONNECTS™
1. Wiring Module w/Hospital Grade Outlet
2. Wiring Module w/Rocker Switch
1 2
AUC/MAUC SERIES – WIRING MODULE
• Shut off power before connecting wiring module to
electrical circuit.
• Install in accordance with all national, state, and local
codes.
• Do not connect to an ungrounded supply.
• Wiring module is intended for undercabinet or
undershelf mounting for use in conjunction with the
Stratalume ConnectsTM undercabinet light xtures.
Failure to install on a mechanically-sound surface may
result in personal injury, xture damage, or potential
re hazard.
This instruction sheet applies for the Stratalume ConnectsTM WML, WML/SW, WML/HGO, WMD, WMD/SW, WMD/
HGO and WMD/MS wiring modules. These accessories are designed to decrease installation time of series-mount
xtures by eliminating the need to electrically wire each xture.
The WML series of wiring modules are used in conjunction with the AUCSL, AUCDL, and AUCLED xture series. The
WMD series of wiring modules are used in conjunction with the AUCSD and AUCDD series.
GENERAL
SEE FIXTURE LABEL OR ANY APPLICABLE RESTRICTIONS.
• Do not install outdoors or in applications not intended
for use.
• Read all markings and labels to ensure correct
installation of wiring module. Supplemental instructions
may be located within the wiring module, in addition to
this instruction sheet, regarding orientation, mounting
restrictions, or optional equipment.
• Read additional instructions provided with the
Stratalume ConnectsTM light xture(s).
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS
BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH
ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT
TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS
AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE.
SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE
FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING
ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS

www.kenall.com |P: 800-4-Kenall |F: 262-891-9701 |10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents
found at www.kenall.com/patents.Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
2
INSTALLATION INSTRUCTIONS
F-2257-091118
HGO — Hospital-Grade Outlet
SW — Switch
MS — Motion Sensor
HARDWARE INCLUDED
All hardware required to mount a wiring module is
supplied with the unit. See Figure 2.
All hardware bags contain:
(A) - Four (4) #8 x 1/2" mounting screws
(B) - Two (2) 8-32 × 3/8" screws (for NM)
Hardware bags provided with WML series wiring
modules also contain:
(C) - Two (2) 8-32 × 3/4" screws (for FMC)
(D) - One (1) NM/FMC connector clamp
(E) - One (1) connector nut
(F) - One (1) NM/FMC connector
INSTALLATION
I. Wiring Module Mounting Procedure Wiring modules
provide power to ConnectsTM light xtures designated
as “series-mount” through the electrical connectors
at each end. Make sure all xtures to be mounted in
the run are indeed “series-mount”. Depending on
the type of electrical accessory provided, the wiring
modules can also provide master switching of the run
by toggle switch or occupancy sensor. The available
hospital-grade outlet can also provide a powersource
for electrical appliances up to 15A.
Use the following steps to mount all Stratalume
ConnectsTM xtures with wiring modules. Refer to xture
instructions for additional information.
1. Determine where xture(s) will be mounted.
Determine location of wiring module within the run. The
wiring module will be mounted rst.
2. Determine overall length of series to ensure
that adequate under-cabinet space exists. Allow
1" clearance on each side for installation of plastic
end covers (provided with xtures) after xtures are
mounted in desired location.
3. Ensure adequate clearance exists at the rear of the
wiring module for electrical connection with FMC or NM
wire.
NOTE: All xtures being mounted together must be
mounted in a straight line to ensure proper electrical
connection is made between xtures.
4. Draw a straight line that will locate the back edge of
all xtures.
5. Lift the wiring module into place in desired location
by lining up the back edge with the line drawn in Step
4.
6. When the wiring module is positioned correctly,
secure xture by the mounting holes (see Figure 1) with
four #8 screws (A).
TERMINOLOGY

www.kenall.com |P: 800-4-Kenall |F: 262-891-9701 |10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents
found at www.kenall.com/patents.Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
3
INSTALLATION INSTRUCTIONS
F-2257-091118
7. Skip to Section II—Electrical Connection.
Make electrical connection at wiring module
before mounting additional xtures.
8. Lift subsequent xtures into place using line drawn
in Step 5 for proper alignment. Mounting ears on
endcaps t into previouslymounted unit. Each new
xture should butt against the previous xture without
gaps.
9. Secure subsequent xtures at opposite ends using
two #8 screws (A).
10. Test operation of xtures and wiring module
electrical accessories before extending series too long.
11. Repeat Steps 8 and 9 for each additional xture in
the series.
12. If interconnect cordset (IC) accessories will be used
to connects runs around corners or across transitions,
plug them into their respective endcaps now. If not,
snap in end covers to hide unused electrical connectors
and mounting hardware.
II. ELECTRICAL CONNECTION PROCEDURE
MAKE SURE AC POWER IS OFF. ELECTRICAL
CONNECTION TO SUPPLY MUST BE MADE WITHIN
POWER MODULE
1. Remove plastic cover by squeezing the ngergrab
area in the middle of the wiring module to disengage
the internal hook from the housing.
2. Remove the two (2) small screws securing the cover
plate to the housing and swing out.
3. Remove access plate from the back of the xture
housing.
4. On WML models, attach supplied NM/FMC
connector (D, E, F) to access panel. On WMD models,
use standard 3/8” conduit tting. Refer to Figure 3.
5. Secure the proper length of supply wire to the NM/
FMC connector using connector-provided screws for
FMC or screws (B) for NM wire. Re-install the access
plate.
6. Connect supply wires to wiring module wires using
appropriate wire nuts. Notice wire labels and color
to ensure correct wires are connected—especially
in two-circuit applications. Make sure secure ground
connection is made.
7. Push wires neatly into wiring module and reinstall
cover plate and plastic cover.
8. Return to Section I – Mounting Procedure, Step 8 for
mounting the Stratalume ConnectsTM light xtures.
III. FINAL ASSEMBLY
After all xtures have been mounted and tested
for operation, install the plastic end cover(s) over
any exposed end to hide electrical connectors and
mounting hardware. Both left and right end covers
simply snap into their respective ends.
Refer to xture instructions for the end cover removal
procedure.

www.kenall.com |P: 800-4-Kenall |F: 262-891-9701 |10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents
found at www.kenall.com/patents.Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
4
INSTALLATION INSTRUCTIONS
F-2257-091118
For technical assistance, call 1-800-4KENALL (1-800-453-6255).
WARRANTY
CUSTOMER SERVICE
For warranty inFormation visit www.kenall.com/resources/certiFied-PerFormance-warranties
This manual suits for next models
1
Table of contents
Popular Control Unit manuals by other brands

pizzato
pizzato CS FS-3 Series manual

Eaton
Eaton Cutler-Hammer IQMSSPM instructions

Sony
Sony DCU-8000 Operation manual

VAT
VAT 642 Series Installation, operating, & maintenance instructions

Mitsubishi Electric
Mitsubishi Electric A1SJ71AP23Q user manual

RabbitCore
RabbitCore RCM3100 Series Getting started manual

Rabbit
Rabbit RabbitCore RCM3000 user manual

GEM
GEM R487 Victoria operating instructions

BENDIX
BENDIX AR-1 ANTILOCK RELAY VALVE manual

Valeo
Valeo SC1000 IVECO operating instructions

Allen-Bradley
Allen-Bradley ControlNet 1786-RPFM installation instructions

LOVATO ELECTRIC
LOVATO ELECTRIC EXM10 00 instruction manual