Kenmore 106.89592100 User manual

TECHNICAL EDUCATION
2013 - 15” UNDER COUNTER
ICE MAKERS WITH FILTER
KENMORE MODELS
106.89592100
106.89599100
106.89593100
106.89553100

n
i
FORWARD
This Service Manual, 2013 Kenmore 15” Under Counter Ice Makers with Filter, provides the In-Home Service
Professional with informaon on the installaon, operaon, and service of these 2013 ice makers only.
For specic informaon on the model being serviced, refer to the “Use and Care Guide,” or “Tech Sheet”
provided with the ice maker.
The Wiring Diagrams used in this Service Manual are typical and should be used for training purposes only.
Always use the Wiring Diagram supplied with the product when servicing the ice maker.
GOALS AND OBJECTIVES
The goal of this Service Manual is to provide informaon that will enable the In-Home Service Professional
to properly diagnose malfuncons and repair the New Design 15” Under Counter Ice Makers with Filter.
The objecves of this Service Manual are to:
• Understand and follow proper safety precauons.
• Recognize installaon.
• Successfully access components.
• Successfully troubleshoot and diagnose malfuncons.
• Successfully perform necessary repairs.
• Successfully return the ice maker to its proper operaonal status.

n
ii
TABLE OF CONTENTS
Ice Maker Safety ...........................................................................................................................1-2
Model Numbers ............................................................................................................................1-4
Model & Serial Number Label .......................................................................................................1-5
......................................................................................................................1-5
...................................................................................................................................1-6
TABLE OF CONTENTS .....................................................................................................................2-3
..........................................................................................................2-3
WARRANTY ..................................................................................................................................2-4
ICE MAKER SAFETY .......................................................................................................................2-5
INSTALLATION INSTRUCTIONS .......................................................................................................2-5
ICE MAKER USE ...........................................................................................................................2-15
ICE MAKER CARE .........................................................................................................................2-17
....................................................................................................................2-20
.......................................................................................................2-22
SERVICE NUMBERS .....................................................................................................................2-23
.........................................................................................................................3-2
.....................................................................................................................3-2
Water System ...............................................................................................................................3-4
Electrical System ...........................................................................................................................3-4
.......................................................................................................................3-5
...............................................................................................................4-2
......................................................................................................................4-3
..........................................................................................................4-7
..........................................................................................4-10
Safety ...........................................................................................................................................5-2
.......................................................................................................................5-3
............................................................................................................................5-8
Sealed System Repair ....................................................................................................................6-2
...........................................................6-3
.....................................................................................................6-3
...........................................................................................................................6-4
............................................................................................................6-5
..................................................................................................6-7
...........................................................................................................6-8
.................................................................................................................6-9
...................................................................................................................6-11

GENERAL INFORMATION
n
1-1
Section 1:
General Information
This secon provides general informaon concerning 2013
New Design 15” Ice Makers.
nIce Maker Safety
nModel Numbers
nModel & Serial Number Label
nTech Sheet Locaon
nDimensions

1-2 n
GENERAL INFORMATION
Ice Maker Safety
You can be killed or seriously injured if you don't immediately
You can be killed or seriously injured if you don't follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
IMPORTANTSAFETYINSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury when using your ice maker, follow these basic
precautions:
SAVETHESEINSTRUCTIONS
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Disconnect power before manually cleaning the inside components.
Disconnect power before servicing.
Replace all parts and panels before operating.
Use two or more people to move and install ice maker.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.

GENERAL INFORMATION
n
1-3
DANGER
Electrical Shock Hazard
Only authorized technicians should perform
diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can result in
death or electrical shock.
Ice Maker Safety (cont.)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
7
0LUMBING0ROBLEMS
Ice Maker Water Filtration System
Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI Standards 42.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
■It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
■Use replacement filter P6RFWG2K, P6RFGEG2K, P6RFKG2K, Part
Number ICE2.
Style 1 – When the water filter status display changes from “GOOD”
to “ORDER,” order a new filter. When the filter indicator reads
“REPLACE,” it is recommended that you replace the filter.
Style 2 – Press FILTER to check the status of your water filter. If the
filter indicator light is yellow and the words “ORDER FILTER” appear
on the display screen, order a new filter. If the filter indicator light is
red, it is recommended that you replace the filter.
■These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
■Refer to the “Warranty” section for the Manufacturer’s name, address
and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
02/",%-2%#/--%.$%$3/,54)/.3
Water Not Entering Drain
Properly If the drain hose is not aligned over the drain, move the ice maker to align the drain.
NOTE:Service technicians cannot repair plumbing problems outside of the ice maker. Call a licensed, qualified
plumber.
System tested and certified by NSF
International against NSF/ANSI
Standard42 for the reduction of
Chlorine Ta ste and Odor.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor50% reduction 1.9727 mg/L 2.0 mg/L ± 10% 0.71 mg/L 0.7788 mg/L 70.2 72.81
0%2&/2-!.#%$!4!3(%%4
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.50 gpm (1.89 Lpm) @ 60 psi
® NSF is a registered trademark of NSF International.
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
Verify the controls are in the off position so that the appliance does not start when energized.
Keep other people a safe distance away from the appliance to prevent potential injury.

1-4 n
GENERAL INFORMATION
Model Numbers
KENMORE
106.89592100
106.89599100
106.89593100
106.89553100
*Introductory Models
KENMORE 2013 NEW DESIGN ICE MAKERS WITH
FILTER

GENERAL INFORMATION
n
1-5
Model & Serial Number Labal
Tech Sheet Location
MODEL &
SERIAL
NUMBER
LABEL
t,/Z>WKK>KZWKZd/KEKE&/Ed/> ϴ
^^/E'tdZs>sEd,E/>d^,d
Zz^d>ϱϬη/D,/EͲϮϬϭϯdϯ
tĂƚĞƌsĂůǀĞ
dĞĐŚ^ŚĞĞƚ

1-6 n
GENERAL INFORMATION
Notes
15” Dimensions Inches
Carton Depth 28 1/2
Carton Height 36 3/8
Carton Width 17 3/8
Cutout Depth (in) 24
Cutout Height (in) 34
Cutout Width (in) 15
Depth 23 1/8
Height 34 3/8
Width 14 7/8
Depth Closed Excluding Handles 23 1/8
Depth Excluding Doors 21 1/2
Depth With Door Open 90 Degree 36 7/8
Gross Weight 98
Maximum Height 34 3/8
Minimum Height 33 7/8
Net Weight 90
Oset Cabinet Door Handle @90 2 5/8
Width Doors Open 90 Degrees 14 7/8
Width of Cabinet Only 14 7/8
Width with Doors Closed 14 7/8
Dimensions

INSTALLATION ANd OperATINg INSTrucTIONS
n
2-1
Section 2:
Installation and
Operating Instructions
This secon provides operaonal use and care informaon for
2013 New Design 15” Ice Makers.
nTABLE OF CONTENTS
nPROTECTION AGREEMENTS
nWARRANTY
nICE MAKER SAFETY
nINSTALLATION INSTRUCTIONS
nICE MAKER USE
nICE MAKER CARE
nTROUBLESHOOTING
nPERFORMANCE DATA SHEET
nSERVICE NUMBERS

2-2 n
INSTALLATION ANd OperATINg INSTrucTIONS
8VH&DUH*XLGH
0DQXDO GHXVR\FXLGDGR
*XLGHGXWLOLVDWLRQHWGHQWUHWLHQ
(QJOLVK(VSDÙRO)UDQÐDLV
0RGHOV0RGHORV0RGÔOHV
.HQPRUH§
,FH0DNHU
)ÊEULFDGHKLHOR
0DFKLQHÍJODÐRQV
FRORUQXPEHUQàPHURGHFRORUOHQXPÑURGHODFRXOHXU
31:$
6HDUV%UDQGV0DQDJHPHQW&RUSRUDWLRQ
+RIIPDQ(VWDWHV,/86$
ZZZNHQPRUHFRP
ZZZVHDUVFRP
6HDUV&DQDGD,QF
7RURQWR2QWDULR&DQDGD0%&
ZZZVHDUVFD

INSTALLATION ANd OperATINg INSTrucTIONS
n
2-3
7$%/(2)&217(176
3527(&7,21$*5((0(176
:$55$17<
,&(0$.(56$)(7<
,167$//$7,21,16758&7,216
8QSDFNWKH,FH0DNHU
/RFDWLRQ5HTXLUHPHQWV
(OHFWULFDO5HTXLUHPHQWV
:DWHU6XSSO\5HTXLUHPHQWV
&RQQHFW:DWHU6XSSO\
'UDLQ3XPS,QVWDOODWLRQ
'UDLQ&RQQHFWLRQ
'RRU5HYHUVDO6LGH 6ZLQJ 2QO\
/HYHOLQJ
:DWHU)LOWUDWLRQ6\VWHP
,&(0$.(586(
+RZ<RXU,FH0DNHU:RUNV
8VLQJWKH&RQWUROV
1RUPDO6RXQGV
,&(0$.(5&$5(
&OHDQLQJ
9DFDWLRQDQG0RYLQJ&DUH
7528%/(6+227,1*
,FH0DNHU2SHUDWLRQ
,FH3URGXFWLRQ
,FH4XDOLW\
3OXPELQJ3UREOHPV
$FFHVVRULHV
3(5)250$1&('$7$6+((7
6(59,&(180%(56 %$&.&29(5
¸1',&(
7$%/('(60$7,·5(6
3527(&7,21$*5((0(176
0DVWHU3URWHFWLRQ$JUHHPHQWV
&RQJUDWXODWLRQVRQPDNLQJDVPDUWSXUFKDVH
<RXUQHZ
.HQPRUH§SURGXFWLVGHVLJQHGDQGPDQXIDFWXUHGIRU\HDUVRI
GHSHQGDEOHRSHUDWLRQ%XWOLNHDOOSURGXFWVLWPD\UHTXLUH
SUHYHQWLYHPDLQWHQDQFHRUUHSDLUIURPWLPHWRWLPH7KDWVZKHQ
KDYLQJD0DVWHU3URWHFWLRQ$JUHHPHQWFDQVDYH\RXPRQH\DQG
DJJUDYDWLRQ
7KH0DVWHU3URWHFWLRQ$JUHHPHQWDOVRKHOSVH[WHQGWKHOLIHRI
\RXUQHZSURGXFW+HUHVZKDWWKH$JUHHPHQWLQFOXGHV
✔3DUWVDQGODERUQHHGHGWRKHOSNHHSSURGXFWVRSHUDWLQJ
SURSHUO\XQGHUQRUPDOXVHQRWMXVWGHIHFWV2XUFRYHUDJH
JRHVZHOOEH\RQGWKHSURGXFWZDUUDQW\1RGHGXFWLEOHVQR
IXQFWLRQDOIDLOXUHH[FOXGHGIURPFRYHUDJHUHDOSURWHFWLRQ
✔([SHUWVHUYLFHE\DIRUFHRIPRUHWKDQDXWKRUL]HG
6HDUVVHUYLFHWHFKQLFLDQVZKLFKPHDQVVRPHRQH\RXFDQ
WUXVWZLOOEHZRUNLQJRQ\RXUSURGXFW
✔8QOLPLWHGVHUYLFHFDOOVDQGQDWLRQZLGHVHUYLFHDVRIWHQDV
\RXZDQWXVZKHQHYHU\RXZDQWXV
✔k1ROHPRQyJXDUDQWHHqUHSODFHPHQWRI\RXUFRYHUHG
SURGXFWLIIRXURUPRUHSURGXFWIDLOXUHVRFFXUZLWKLQWZHOYH
PRQWKV
✔3URGXFWUHSODFHPHQWLI\RXUFRYHUHGSURGXFWFDQWEHIL[HG
✔$QQXDO3UHYHQWLYH0DLQWHQDQFH&KHFNDW\RXUUHTXHVWqQR
H[WUDFKDUJH
✔)DVWKHOSE\SKRQHqZHFDOOLW5DSLG5HVROXWLRQqSKRQH
VXSSRUWIURPD6HDUVUHSUHVHQWDWLYHRQDOOSURGXFWV7KLQNRI
XVDVDkWDONLQJRZQHUVPDQXDOy
✔3RZHUVXUJHSURWHFWLRQDJDLQVWHOHFWULFDOGDPDJHGXHWR
SRZHUIOXFWXDWLRQV
✔)RRG/RVV3URWHFWLRQDQQXDOO\IRUDQ\IRRGVSRLODJH
WKDWLVWKHUHVXOWRIPHFKDQLFDOIDLOXUHRIDQ\FRYHUHG
UHIULJHUDWRURUIUHH]HU
✔5HQWDOUHLPEXUVHPHQWLIUHSDLURI\RXUFRYHUHGSURGXFWWDNHV
ORQJHUWKDQSURPLVHG
✔GLVFRXQWRIIWKHUHJXODUSULFHRIDQ\QRQFRYHUHG
UHSDLUVHUYLFHDQGUHODWHGLQVWDOOHGSDUWV
2QFH\RXSXUFKDVHWKH$JUHHPHQWDVLPSOHSKRQHFDOOLVDOO
WKDWLWWDNHVIRU\RXWRVFKHGXOHVHUYLFH<RXFDQFDOODQ\WLPH
GD\RUQLJKWRUVFKHGXOHDVHUYLFHDSSRLQWPHQWRQOLQH
7KH0DVWHU3URWHFWLRQ$JUHHPHQWLVDULVNIUHHSXUFKDVH,I\RX
FDQFHOIRUDQ\UHDVRQGXULQJWKHSURGXFWZDUUDQW\SHULRGZH
ZLOOSURYLGHDIXOOUHIXQG2UDSURUDWHGUHIXQGDQ\WLPHDIWHU
WKHSURGXFWZDUUDQW\SHULRGH[SLUHV3XUFKDVH\RXU0DVWHU
3URWHFWLRQ$JUHHPHQWWRGD\
6RPHOLPLWDWLRQVDQGH[FOXVLRQVDSSO\)RUSULFHVDQG
DGGLWLRQDOLQIRUPDWLRQLQWKH86$FDOOąąą
&RYHUDJHLQ&DQDGDYDULHVRQVRPHLWHPV)RUIXOOGHWDLOVFDOO
6HDUV&DQDGDDWąąą
6HDUV,QVWDOODWLRQ6HUYLFH
)RU6HDUVSURIHVVLRQDOLQVWDOODWLRQRIKRPHDSSOLDQFHVJDUDJH
GRRURSHQHUVZDWHUKHDWHUVDQGRWKHUPDMRUKRPHLWHPVLQWKH
86$RU&DQDGDFDOOąąą0<ą+20(§
7$%/(2)&217(176
3527(&7,21$*5((0(176
:$55$17<
,&(0$.(56$)(7<
,167$//$7,21,16758&7,216
8QSDFNWKH,FH0DNHU
/RFDWLRQ5HTXLUHPHQWV
(OHFWULFDO5HTXLUHPHQWV
:DWHU6XSSO\5HTXLUHPHQWV
&RQQHFW:DWHU6XSSO\
'UDLQ3XPS,QVWDOODWLRQ
'UDLQ&RQQHFWLRQ
'RRU5HYHUVDO6LGH 6ZLQJ 2QO\
/HYHOLQJ
:DWHU)LOWUDWLRQ6\VWHP
,&(0$.(586(
+RZ<RXU,FH0DNHU:RUNV
8VLQJWKH&RQWUROV
1RUPDO6RXQGV
,&(0$.(5&$5(
&OHDQLQJ
9DFDWLRQDQG0RYLQJ&DUH
7528%/(6+227,1*
,FH0DNHU2SHUDWLRQ
,FH3URGXFWLRQ
,FH4XDOLW\
3OXPELQJ3UREOHPV
$FFHVVRULHV
3(5)250$1&('$7$6+((7
6(59,&(180%(56 %$&.&29(5
¸1',&(
7$%/('(60$7,·5(6
3527(&7,21$*5((0(176
0DVWHU3URWHFWLRQ$JUHHPHQWV
&RQJUDWXODWLRQVRQPDNLQJDVPDUWSXUFKDVH
<RXUQHZ
.HQPRUH§SURGXFWLVGHVLJQHGDQGPDQXIDFWXUHGIRU\HDUVRI
GHSHQGDEOHRSHUDWLRQ%XWOLNHDOOSURGXFWVLWPD\UHTXLUH
SUHYHQWLYHPDLQWHQDQFHRUUHSDLUIURPWLPHWRWLPH7KDWVZKHQ
KDYLQJD0DVWHU3URWHFWLRQ$JUHHPHQWFDQVDYH\RXPRQH\DQG
DJJUDYDWLRQ
7KH0DVWHU3URWHFWLRQ$JUHHPHQWDOVRKHOSVH[WHQGWKHOLIHRI
\RXUQHZSURGXFW+HUHVZKDWWKH$JUHHPHQWLQFOXGHV
✔3DUWVDQGODERUQHHGHGWRKHOSNHHSSURGXFWVRSHUDWLQJ
SURSHUO\XQGHUQRUPDOXVHQRWMXVWGHIHFWV2XUFRYHUDJH
JRHVZHOOEH\RQGWKHSURGXFWZDUUDQW\1RGHGXFWLEOHVQR
IXQFWLRQDOIDLOXUHH[FOXGHGIURPFRYHUDJHUHDOSURWHFWLRQ
✔([SHUWVHUYLFHE\DIRUFHRIPRUHWKDQDXWKRUL]HG
6HDUVVHUYLFHWHFKQLFLDQVZKLFKPHDQVVRPHRQH\RXFDQ
WUXVWZLOOEHZRUNLQJRQ\RXUSURGXFW
✔8QOLPLWHGVHUYLFHFDOOVDQGQDWLRQZLGHVHUYLFHDVRIWHQDV
\RXZDQWXVZKHQHYHU\RXZDQWXV
✔k1ROHPRQyJXDUDQWHHqUHSODFHPHQWRI\RXUFRYHUHG
SURGXFWLIIRXURUPRUHSURGXFWIDLOXUHVRFFXUZLWKLQWZHOYH
PRQWKV
✔3URGXFWUHSODFHPHQWLI\RXUFRYHUHGSURGXFWFDQWEHIL[HG
✔$QQXDO3UHYHQWLYH0DLQWHQDQFH&KHFNDW\RXUUHTXHVWqQR
H[WUDFKDUJH
✔)DVWKHOSE\SKRQHqZHFDOOLW5DSLG5HVROXWLRQqSKRQH
VXSSRUWIURPD6HDUVUHSUHVHQWDWLYHRQDOOSURGXFWV7KLQNRI
XVDVDkWDONLQJRZQHUVPDQXDOy
✔3RZHUVXUJHSURWHFWLRQDJDLQVWHOHFWULFDOGDPDJHGXHWR
SRZHUIOXFWXDWLRQV
✔)RRG/RVV3URWHFWLRQDQQXDOO\IRUDQ\IRRGVSRLODJH
WKDWLVWKHUHVXOWRIPHFKDQLFDOIDLOXUHRIDQ\FRYHUHG
UHIULJHUDWRURUIUHH]HU
✔5HQWDOUHLPEXUVHPHQWLIUHSDLURI\RXUFRYHUHGSURGXFWWDNHV
ORQJHUWKDQSURPLVHG
✔GLVFRXQWRIIWKHUHJXODUSULFHRIDQ\QRQFRYHUHG
UHSDLUVHUYLFHDQGUHODWHGLQVWDOOHGSDUWV
2QFH\RXSXUFKDVHWKH$JUHHPHQWDVLPSOHSKRQHFDOOLVDOO
WKDWLWWDNHVIRU\RXWRVFKHGXOHVHUYLFH<RXFDQFDOODQ\WLPH
GD\RUQLJKWRUVFKHGXOHDVHUYLFHDSSRLQWPHQWRQOLQH
7KH0DVWHU3URWHFWLRQ$JUHHPHQWLVDULVNIUHHSXUFKDVH,I\RX
FDQFHOIRUDQ\UHDVRQGXULQJWKHSURGXFWZDUUDQW\SHULRGZH
ZLOOSURYLGHDIXOOUHIXQG2UDSURUDWHGUHIXQGDQ\WLPHDIWHU
WKHSURGXFWZDUUDQW\SHULRGH[SLUHV3XUFKDVH\RXU0DVWHU
3URWHFWLRQ$JUHHPHQWWRGD\
6RPHOLPLWDWLRQVDQGH[FOXVLRQVDSSO\)RUSULFHVDQG
DGGLWLRQDOLQIRUPDWLRQLQWKH86$FDOOąąą
&RYHUDJHLQ&DQDGDYDULHVRQVRPHLWHPV)RUIXOOGHWDLOVFDOO
6HDUV&DQDGDDWąąą
6HDUV,QVWDOODWLRQ6HUYLFH
)RU6HDUVSURIHVVLRQDOLQVWDOODWLRQRIKRPHDSSOLDQFHVJDUDJH
GRRURSHQHUVZDWHUKHDWHUVDQGRWKHUPDMRUKRPHLWHPVLQWKH
86$RU&DQDGDFDOOąąą0<ą+20(§

2-4 n
INSTALLATION ANd OperATINg INSTrucTIONS
.(1025((/,7(§/,0,7(' :$55$17<
:KHQWKLVDSSOLDQFHLVLQVWDOOHGRSHUDWHGDQGPDLQWDLQHG
DFFRUGLQJWRDOOVXSSOLHGLQVWUXFWLRQVWKHIROORZLQJZDUUDQW\
FRYHUDJHDSSOLHV7RDUUDQJHIRUZDUUDQW\VHUYLFHFDOO
ąąą0<ą+20(§ąąą
2QH<HDU/LPLWHG:DUUDQW\RQ$SSOLDQFH
)RURQH\HDUIURPWKHGDWHRISXUFKDVHIUHHUHSDLUZLOOEH
SURYLGHGLIDQ\QRQFRQVXPDEOHSDUWRIWKLVDSSOLDQFHIDLOVGXH
WRGHIHFWVLQPDWHULDORUZRUNPDQVKLS,IWKHDSSOLDQFHLVHYHU
XVHGIRURWKHUWKDQSULYDWHIDPLO\SXUSRVHVWKLVFRYHUDJH
DSSOLHVIRURQO\ GD\VIURPWKHSXUFKDVHGDWH
)LYH<HDU/LPLWHG:DUUDQW\RQ6HDOHG6\VWHP
)RUILYH\HDUVIURPWKHGDWHRISXUFKDVHWKHVHDOHGUHIULJHUDQW
V\VWHPRIWKLVDSSOLDQFHLVZDUUDQWHGDJDLQVWDQ\GHIHFWVLQ
PDWHULDORUZRUNPDQVKLS1HZV\VWHPFRPSRQHQWVZLOOEH
VXSSOLHGIRUGHIHFWLYHRQHVIUHHRIFKDUJH<RXDUHUHVSRQVLEOH
IRUWKHODERUFRVWRIFRPSRQHQWLQVWDOODWLRQDIWHUWKHILUVW\HDU
IURPWKHGDWHRISXUFKDVH,IWKHDSSOLDQFHLVHYHUXVHGIRU
RWKHUWKDQSULYDWHIDPLO\SXUSRVHVWKLVFRYHUDJHDSSOLHVIRU
RQO\RQH\HDUIURPWKHSXUFKDVHGDWH
7KLVZDUUDQW\FRYHUVRQO\GHIHFWVLQPDWHULDODQG
ZRUNPDQVKLS6HDUVZLOO127SD\IRU
&RQVXPDEOHSDUWVWKDWFDQZHDURXWIURPQRUPDOXVH
LQFOXGLQJEXWQRWOLPLWHGWRILOWHUVEHOWVLQFDQGHVFHQWOLJKW
EXOEVDQGEDJV
$VHUYLFHWHFKQLFLDQWRLQVWUXFWWKHXVHULQFRUUHFWSURGXFW
LQVWDOODWLRQRSHUDWLRQRUPDLQWHQDQFH
$VHUYLFHWHFKQLFLDQWRFOHDQRUPDLQWDLQWKLVSURGXFW
'DPDJHWRRUIDLOXUHRIWKLVSURGXFWLILWLVQRWLQVWDOOHG
RSHUDWHGRUPDLQWDLQHGDFFRUGLQJWRWKHDOOLQVWUXFWLRQV
VXSSOLHGZLWKWKHSURGXFW
'DPDJHWRRUIDLOXUHRIWKLVSURGXFWUHVXOWLQJIURPDFFLGHQW
DEXVHPLVXVHRUXVHIRURWKHUWKDQLWVLQWHQGHGSXUSRVH
'DPDJHWRRUIDLOXUHRIWKLVSURGXFWFDXVHGE\WKHXVHRI
GHWHUJHQWVFOHDQHUVFKHPLFDOVRUXWHQVLOVRWKHUWKDQWKRVH
UHFRPPHQGHGLQDOOLQVWUXFWLRQVVXSSOLHGZLWKWKHSURGXFW
'DPDJHWRRUIDLOXUHRISDUWVRUV\VWHPVUHVXOWLQJIURP
XQDXWKRUL]HGPRGLILFDWLRQVPDGHWRWKLVSURGXFW
'LVFODLPHURILPSOLHGZDUUDQWLHVOLPLWDWLRQRIUHPHGLHV
&XVWRPHUVVROHDQGH[FOXVLYHUHPHG\XQGHUWKLVOLPLWHG
ZDUUDQW\VKDOOEHSURGXFWUHSDLUDVSURYLGHGKHUHLQ,PSOLHG
ZDUUDQWLHVLQFOXGLQJZDUUDQWLHVRIPHUFKDQWDELOLW\RUILWQHVVIRU
DSDUWLFXODUSXUSRVHDUHOLPLWHGWRRQH\HDURUWKHVKRUWHVW
SHULRGDOORZHGE\ODZ6HDUVVKDOOQRWEHOLDEOHIRULQFLGHQWDORU
FRQVHTXHQWLDOGDPDJHV6RPHVWDWHVDQGSURYLQFHVGRQRW
DOORZWKHH[FOXVLRQRUOLPLWDWLRQRILQFLGHQWDORUFRQVHTXHQWLDO
GDPDJHVRUOLPLWDWLRQRQWKHGXUDWLRQRILPSOLHGZDUUDQWLHVRI
PHUFKDQWDELOLW\RUILWQHVVVRWKHVHH[FOXVLRQVRUOLPLWDWLRQVPD\
QRWDSSO\WR\RX
7KLVZDUUDQW\DSSOLHVRQO\ZKLOHWKLVDSSOLDQFHLVXVHGLQWKH
8QLWHG6WDWHVRU&DQDGD
7KLVZDUUDQW\JLYHV\RXVSHFLILFOHJDOULJKWVDQG\RXPD\DOVR
KDYHRWKHUULJKWVZKLFKYDU\IURPVWDWHWRVWDWH
,Q&DQDGDLQKRPHUHSDLUVHUYLFHLVQRWDYDLODEOHLQDOO
DUHDVQRUZLOOWKLVZDUUDQW\FRYHUXVHURUVHUYLFHUWUDYHODQG
WUDQVSRUWDWLRQH[SHQVHVLIWKLVSURGXFWLVORFDWHGLQDUHPRWH
DUHDDVGHILQHGE\6HDUV&DQDGD,QFZKHUHDQDXWKRUL]HG
VHUYLFHULVQRWDYDLODEOH
6HDUV%UDQGV0DQDJHPHQW&RUSRUDWLRQ
+RIIPDQ(VWDWHV,/
6HDUV&DQDGD,QF
7RURQWR2QWDULR&DQDGD0%&
3URGXFW5HFRUG
,QWKHVSDFHEHORZUHFRUG\RXUFRPSOHWHPRGHOQXPEHUVHULDO
QXPEHUDQGSXUFKDVHGDWH<RXFDQILQGWKLVLQIRUPDWLRQRQWKH
PRGHODQGVHULDOQXPEHUODEHO
+DYHWKLVLQIRUPDWLRQDYDLODEOHWRKHOS\RXREWDLQDVVLVWDQFHRU
VHUYLFHPRUHTXLFNO\ZKHQHYHU\RXFRQWDFW6HDUVFRQFHUQLQJ
\RXULFHPDNHU
0RGHOQXPEHU BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
6HULDOQXPEHU BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
3XUFKDVHGDWHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
6DYHWKHVHLQVWUXFWLRQVDQG\RXUVDOHVUHFHLSWIRUIXWXUH
UHIHUHQFH

INSTALLATION ANd OperATINg INSTrucTIONS
n
2-5
,&(0$.(56$)(7<
,167$//$7,21,16758&7,216
8QSDFNWKH,FH0DNHU
5HPRYLQJ3DFNDJLQJ0DWHULDOV
5HPRYHWDSHDQGJOXHIURP\RXULFHPDNHUEHIRUHXVLQJ
■7RUHPRYHDQ\UHPDLQLQJWDSHRUJOXHIURPWKHH[WHULRURI
WKHLFHPDNHUUXEWKHDUHDEULVNO\ZLWK\RXUWKXPE7DSHRU
JOXHUHVLGXHFDQDOVREHHDVLO\UHPRYHGE\UXEELQJDVPDOO
DPRXQWRIOLTXLGGLVKVRDSRYHUWKHDGKHVLYHZLWK\RXU
ILQJHUV:LSHZLWKZDUPZDWHUDQGGU\
■'RQRWXVHVKDUSLQVWUXPHQWVUXEELQJDOFRKROIODPPDEOH
IOXLGVRUDEUDVLYHFOHDQHUVWRUHPRYHWDSHRUJOXH'RQRW
XVHFKORULQHEOHDFKRQWKHVWDLQOHVVVWHHOVXUIDFHVRIWKHLFH
PDNHU7KHVHSURGXFWVFDQGDPDJHWKHVXUIDFHRI\RXU
LFHPDNHU
You can be killed or seriously injured if you don't immediately
You can be killed or seriously injured if you don't follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
IMPORTA NT SAFETY INSTRUCTIONS
WARNING
: To reduce the risk of fire, electric shock, or injury when using your ice maker, follow these basic
precautions:
SAVE THESE INSTRUCTIONS
■
Plug into a grounded 3 prong outlet.
■
Do not remove ground prong.
■
Do not use an adapter.
■
Do not use an extension cord.
■
Disconnect power before manually cleaning the inside components.
■
Disconnect power before servicing.
■
Replace all parts and panels before operating.
■
Use two or more people to move and install ice maker.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
W10541616B
How Your Ice Maker Works
When you first start your ice maker, the water pan will fill and the
system will rinse itself before starting to make ice. The rinsing process
takes about 5 minutes.
Under normal operating conditions, the ice maker will cycle at preset
temperatures. The ice level sensor located in the ice storage bin will
monitor the ice levels.
IMPORTANT: If the water supply to the ice maker is turned off, be sure
to set the ice maker control to OFF.
The Ice Making Process
1. Water is constantly circulated over a
freezing plate. As the water freezes into
ice, the minerals in the water are
rejected. This produces a sheet of ice
with a low mineral content.
LEARNMORE
In an effort to conserve natural resources, this ice maker includes a condensed User Guide. A complete Use and Care
Guide can be downloaded at www.jennair.com/manuals.
The model number is located on the inside of the ice maker.
Register your ice maker at www.jennair.com.
Para una version de estas instrucciones en español, visite www.jennair.com.
User Guide
Ice Maker
You can be killed or seriously injured if you don’t immediately follow instructions.
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the
instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
DANGER
WARNING
IMPORTA NT SAFETY INSTRUCTIONS
WARNING:To reduce the risk of fire, electric shock, or injury when using your ice maker, follow these basic
precautions:
SAVE THESE INSTRUCTIONS
■Plug into a grounded 3 prong outlet.
■Do not remove ground prong.
■Do not use an adapter.
■Do not use an extension cord.
■Disconnect power before cleaning.
■Disconnect power before servicing.
■Replace all parts and panels before operating.
■Use two or more people to move and install ice maker.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.
Operating Your Ice Maker
,&(0$.(56$)(7<
,167$//$7,21,16758&7,216
8QSDFNWKH,FH0DNHU
5HPRYLQJ3DFNDJLQJ0DWHULDOV
5HPRYHWDSHDQGJOXHIURP\RXULFHPDNHUEHIRUHXVLQJ
■7RUHPRYHDQ\UHPDLQLQJWDSHRUJOXHIURPWKHH[WHULRURI
WKHLFHPDNHUUXEWKHDUHDEULVNO\ZLWK\RXUWKXPE7DSHRU
JOXHUHVLGXHFDQDOVREHHDVLO\UHPRYHGE\UXEELQJDVPDOO
DPRXQWRIOLTXLGGLVKVRDSRYHUWKHDGKHVLYHZLWK\RXU
ILQJHUV:LSHZLWKZDUPZDWHUDQGGU\
■'RQRWXVHVKDUSLQVWUXPHQWVUXEELQJDOFRKROIODPPDEOH
IOXLGVRUDEUDVLYHFOHDQHUVWRUHPRYHWDSHRUJOXH'RQRW
XVHFKORULQHEOHDFKRQWKHVWDLQOHVVVWHHOVXUIDFHVRIWKHLFH
PDNHU7KHVHSURGXFWVFDQGDPDJHWKHVXUIDFHRI\RXU
LFHPDNHU
You can be killed or seriously injured if you don't immediately
You can be killed or seriously injured if you don't follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
IMPORTA NT SAFETY INSTRUCTIONS
WARNING
: To reduce the risk of fire, electric shock, or injury when using your ice maker, follow these basic
precautions:
SAVE THESE INSTRUCTIONS
■
Plug into a grounded 3 prong outlet.
■
Do not remove ground prong.
■
Do not use an adapter.
■
Do not use an extension cord.
■
Disconnect power before manually cleaning the inside components.
■
Disconnect power before servicing.
■
Replace all parts and panels before operating.
■
Use two or more people to move and install ice maker.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
Plumbing Problems
Ice Maker Water Filtration System
Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI Standards 42.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
■It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
■Use replacement filter P6RFWG2K, P6RFGEG2K, P6RFKG2K, Part
Number ICE2.
Style 1 – When the water filter status display changes from “GOOD”
to “ORDER,” order a new filter. When the filter indicator reads
“REPLACE,” it is recommended that you replace the filter.
Style 2 – Press FILTER to check the status of your water filter. If the
filter indicator light is yellow and the words “ORDER FILTER” appear
on the display screen, order a new filter. If the filter indicator light is
red, it is recommended that you replace the filter.
■These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
■Refer to the “Warranty” section for the Manufacturer’s name, address
and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
PROBLEM RECOMMENDED SOLUTIONS
Water Not Entering Drain
ProperlyIf the drain hose is not aligned over the drain, move the ice maker to align the drain.
NOTE:Service technicians cannot repair plumbing problems outside of the ice maker. Call a licensed, qualified
plumber.
System tested and certified by NSF
International against NSF/ANSI
Standard42 for the reduction of
Chlorine Taste and Odor.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Ta ste/Odor 50% reduction 1.9727 mg/L 2.0 mg/L ± 10% 0.71 mg/L 0.7788 mg/L 70.2 72.81
Performance Data Sheet
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.50 gpm (1.89 Lpm) @ 60 psi
® NSF is a registered trademark of NSF International.

2-6 n
INSTALLATION ANd OperATINg INSTrucTIONS
&OHDQLQJ%HIRUH8VH
$IWHU\RXUHPRYHDOORIWKHSDFNDJLQJPDWHULDOVFOHDQWKH
LQVLGHRI\RXULFHPDNHUEHIRUHXVLQJLW6HHWKHFOHDQLQJ
LQVWUXFWLRQVLQWKHk,FH0DNHU&DUHyVHFWLRQ
/RFDWLRQ5HTXLUHPHQWV
■7RHQVXUHSURSHUYHQWLODWLRQIRU\RXULFHPDNHUWKHIURQWVLGH
PXVWEHFRPSOHWHO\XQREVWUXFWHG7KHLFHPDNHUPD\EH
FORVHGLQRQWKHWRSDQGWKUHHVLGHVEXWWKHLQVWDOODWLRQ
VKRXOGDOORZWKHLFHPDNHUWREHSXOOHGIRUZDUGIRU
VHUYLFLQJLIQHFHVVDU\
■,QVWDOODWLRQRIWKHLFHPDNHUUHTXLUHVDFROGZDWHUVXSSO\
LQOHWRI¹⁄₄PP2'VRIWFRSSHUWXELQJZLWKDVKXWRII
YDOYHRUDVXSSO\OLQH3DUW1XPEHU5%DQGRQLFH
PDNHUVWKDWUHTXLUHWKHLQVWDOODWLRQRIDGUDLQSXPSDQ
DSSURYHGGUDLQSXPS3DUW1XPEHU$RQO\WRFDUU\WKH
ZDWHUWRDQH[LVWLQJGUDLQ
■&KRRVHDZHOOYHQWLODWHGDUHDZLWKWHPSHUDWXUHVDERYH
£)£&DQGEHORZ£)£&%HVWUHVXOWVDUH
REWDLQHGEHWZHHQ£)DQG£)&DQG£&
■7KHLFHPDNHUPXVWEHLQVWDOOHGLQDQDUHDVKHOWHUHGIURP
WKHHOHPHQWVVXFKDVZLQGUDLQZDWHUVSUD\RUGULS
■:KHQLQVWDOOLQJWKHLFHPDNHUXQGHUDFRXQWHUIROORZWKH
UHFRPPHQGHGRSHQLQJGLPHQVLRQVVKRZQ3ODFHHOHFWULFDO
DQGSOXPELQJIL[WXUHVLQWKHUHFRPPHQGHGORFDWLRQDV
VKRZQ
127(6
■&KHFNWKDWWKHSRZHUVXSSO\FRUGLVQRWGDPDJHGRU
SLQFKHGRUNLQNHGEHWZHHQWKHLFHPDNHUDQGWKH
FDELQHW
■&KHFNWKDWWKHZDWHUVXSSO\OLQHLVQRWGDPDJHGRU
SLQFKHGRUNLQNHGEHWZHHQWKHLFHPDNHUDQGWKH
FDELQHW
■&KHFNWKDWWKHGUDLQOLQHRQVRPHPRGHOVLVQRW
GDPDJHGRUSLQFKHGRUNLQNHGEHWZHHQWKHLFHPDNHU
DQGWKHFDELQHW
■&KRRVHDORFDWLRQZKHUHWKHIORRULVHYHQ,WLVLPSRUWDQWIRU
WKHLFHPDNHUWREHOHYHOLQRUGHUWRZRUNSURSHUO\,I
QHHGHG\RXFDQDGMXVWWKHKHLJKWRIWKHLFHPDNHUE\
FKDQJLQJWKHKHLJKWRIWKHOHYHOLQJOHJV6HHk/HYHOLQJy
(OHFWULFDO5HTXLUHPHQWV
%HIRUH\RXPRYH\RXULFHPDNHULQWRLWVILQDOORFDWLRQLWLV
LPSRUWDQWWRPDNHVXUH\RXKDYHWKHSURSHUHOHFWULFDO
FRQQHFWLRQ
$YROW+]$&RQO\RUDPSHOHFWULFDOVXSSO\
SURSHUO\JURXQGHGLQDFFRUGDQFHZLWKWKH1DWLRQDO(OHFWULFDO
&RGHDQGORFDOFRGHVDQGRUGLQDQFHVLVUHTXLUHG
,WLVUHFRPPHQGHGWKDWDVHSDUDWHFLUFXLWVHUYLQJRQO\\RXULFH
PDNHUEHSURYLGHG8VHDUHFHSWDFOHZKLFKFDQQRWEHWXUQHG
RIIE\DVZLWFKRUSXOOFKDLQ
,03257$17,IWKLVSURGXFWLVFRQQHFWHGWRD*)&,*URXQG
)DXOW&LUFXLW,QWHUUXSWHUHTXLSSHGRXWOHWQXLVDQFHWULSSLQJRI
WKHSRZHUVXSSO\PD\RFFXUUHVXOWLQJLQORVVRIFRROLQJ,FH
TXDOLW\PD\EHDIIHFWHG,IQXLVDQFHWULSSLQJKDVRFFXUUHGDQG
LIWKHFRQGLWLRQRIWKHLFHDSSHDUVSRRUGLVSRVHRILW
5HFRPPHQGHG*URXQGLQJ0HWKRG
7KHLFHPDNHUPXVWEHJURXQGHG7KHLFHPDNHULVHTXLSSHG
ZLWKDSRZHUVXSSO\FRUGKDYLQJDSURQJJURXQGLQJSOXJ7KH
FRUGPXVWEHSOXJJHGLQWRDPDWLQJSURQJJURXQGLQJW\SH
ZDOOUHFHSWDFOHJURXQGHGLQDFFRUGDQFHZLWKWKH1DWLRQDO
(OHFWULFDO&RGHDQGORFDOFRGHVDQGRUGLQDQFHV,IDPDWLQJ
ZDOOUHFHSWDFOHLVQRWDYDLODEOHLWLVWKHSHUVRQDOUHVSRQVLELOLW\
RIWKHFXVWRPHUWRKDYHDSURSHUO\JURXQGHGSURQJZDOO
UHFHSWDFOHLQVWDOOHGE\DTXDOLILHGHOHFWULFLDQ
$ 5HFRPPHQGHGORFDWLRQIRUHOHFWULFDODQGSOXPELQJIL[WXUHV
% )ORRUOHYHO
3¹⁄₂"
(8.9 cm)9"
(22.9 cm)
11¹⁄₂"
(29.2 cm)
24"
(60.1 cm)
15"
(38.1 cm)
34"
(86.4 cm)
Min.
34¹⁄₂"
(87.6 cm)
Max.
B
A
28¹⁄₂"
(72.4 cm)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Ice Maker Operation
Scan the code at left with your mobile device, or visit
https://jennair.custhelp.com
for
recommendations that may help you avoid a service call.
Problem Solver
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
PROBLEMRECOMMENDED SOLUTIONS
Ice Maker Will Not Operate Check that it is plugged into a grounded 3 prong outlet.
Check that the control is turned on.
Replace the fuse or reset the circuit breaker.
NOTE:If problems continue, contact an electrician.
Room temperature must be above 55°F (13°C). Otherwise, bin thermostat may sense cold room temperature
and shut off even though the bin is not full of ice. The ice maker may not restart once it does shut off.
If there was a large amount of water added to the ice maker, wait a few minutes for the drain pump to clear. If
there is still water in the bin, check to see whether the drain hose is kinked.
For models with drain pumps, check that the drain hose is not damaged, or kinked or pinched between cabinet
and ice maker. Use only Whirlpool approved drain pump kit, Part Number 1901A.
Ice Maker Seems NoisyWater overflowing the reservoir is normal. This overflow helps to purge minerals that were removed from the
water during the ice making process.
If there is a “whooshing” sound, check the following things:
■Make sure that the water supply is hooked up and turned on.
■Make sure that the drain cap is tight and the water drain pan pump is securely attached to the water pan.
If there is ice between the evaporator plate and the cutting grid, check that the ice maker is level. If the ice
maker is level, and the problem persists, run a cleaning cycle.
If the ice maker is connected to a water supply pressure in excess of 60 psi, you may hear a loud sound during
water filling associated with the flow of water through the inlet valve. Call a licensed, qualified plumber to
determine the best method to reduce the supply water pressure (50 psi is recommended).

INSTALLATION ANd OperATINg INSTrucTIONS
n
2-7
:DWHU6XSSO\5HTXLUHPHQWV
&KHFNWKDWWKHZDWHUVXSSO\OLQHVDUHLQVXODWHGDJDLQVWIUHH]LQJ
FRQGLWLRQV,FHIRUPDWLRQVLQWKHVXSSO\OLQHVFDQLQFUHDVHZDWHU
SUHVVXUHDQGGDPDJH\RXULFHPDNHURUKRPH'DPDJHIURP
IUR]HQVXSSO\OLQHVLVQRWFRYHUHGE\WKHZDUUDQW\
$FROGZDWHUVXSSO\ZLWKZDWHUSUHVVXUHRIEHWZHHQDQG
SVLDQGN3DLVUHTXLUHGWRRSHUDWHWKHLFHPDNHU
,I\RXKDYHTXHVWLRQVDERXW\RXUZDWHUSUHVVXUHFDOODOLFHQVHG
TXDOLILHGSOXPEHU
5HYHUVH2VPRVLV:DWHU6XSSO\
,03257$17
■$UHYHUVHRVPRVLVZDWHUILOWUDWLRQV\VWHPLVQRW
UHFRPPHQGHGIRULFHPDNHUVWKDWKDYHDGUDLQSXPS
LQVWDOOHG
■)RUJUDYLW\GUDLQV\VWHPVRQO\
■7KHSUHVVXUHRIWKHZDWHUVXSSO\FRPLQJRXWRIDUHYHUVH
RVPRVLVV\VWHPJRLQJWRWKHZDWHULQOHWYDOYHRIWKHLFH
PDNHUQHHGVWREHEHWZHHQDQGSVLDQG
N3D
,IDUHYHUVHRVPRVLVZDWHUILOWUDWLRQV\VWHPLVFRQQHFWHGWR\RXU
FROGZDWHUVXSSO\WKHZDWHUSUHVVXUHWRWKHUHYHUVHRVPRVLV
V\VWHPQHHGVWREHDPLQLPXPRIWR SVLWRN3D
127(7KHUHYHUVHRVPRVLVV\VWHPPXVWSURYLGHJDO/RI
ZDWHUSHUKRXUWRWKHLFHPDNHUIRUSURSHULFHPDNHURSHUDWLRQ
,IDUHYHUVHRVPRVLVV\VWHPLVGHVLUHGRQO\DZKROHKRXVH
FDSDFLW\UHYHUVHRVPRVLVV\VWHPFDSDEOHRIPDLQWDLQLQJWKH
VWHDG\ZDWHUVXSSO\UHTXLUHGE\WKHLFHPDNHULV
UHFRPPHQGHG)DXFHWFDSDFLW\UHYHUVHRVPRVLVV\VWHPVDUHQRW
DEOHWRPDLQWDLQWKHVWHDG\ZDWHUVXSSO\UHTXLUHGE\WKHLFH
PDNHU
,IWKHZDWHUSUHVVXUHWRWKHUHYHUVHRVPRVLVV\VWHPLVOHVVWKDQ
WRSVLWR N3D
■&KHFNWRVHHZKHWKHUWKHVHGLPHQWILOWHULQWKHUHYHUVH
RVPRVLVV\VWHPLVEORFNHG5HSODFHWKHILOWHULIQHFHVVDU\
■$OORZWKHVWRUDJHWDQNRQWKHUHYHUVHRVPRVLVV\VWHPWRUHILOO
DIWHUKHDY\XVDJH
,I\RXKDYHTXHVWLRQVDERXW\RXUZDWHUSUHVVXUHFDOODOLFHQVHG
TXDOLILHGSOXPEHU
&RQQHFW:DWHU6XSSO\
5HDGDOOGLUHFWLRQVEHIRUH\RXEHJLQ
,03257$17
■3OXPELQJVKDOOEHLQVWDOOHGLQDFFRUGDQFHZLWKWKH
,QWHUQDWLRQDO3OXPELQJ&RGHDQGDQ\ORFDOFRGHVDQG
RUGLQDQFHV
■8VHFRSSHUWXELQJRUVXSSO\OLQH3DUW1XPEHU53
DQGFKHFNIRUOHDNV
■,QVWDOOWXELQJRQO\LQDUHDVZKHUHWHPSHUDWXUHVZLOOUHPDLQ
DERYHIUHH]LQJ
7RROV 1HHGHG
*DWKHUWKHUHTXLUHGWRROVDQGSDUWVEHIRUHVWDUWLQJLQVWDOODWLRQ
■)ODWEODGHVFUHZGULYHU
■⁷⁄₁₆DQG¹⁄₂RSHQHQGZUHQFKHVRUWZRDGMXVWDEOHZUHQFKHV
■¹⁄₄QXWGULYHU
127('RQRWXVHDSLHUFLQJW\SHRU ³⁄₁₆PPVDGGOH
YDOYHZKLFKUHGXFHVZDWHUIORZDQGFORJVPRUHHDVLO\
&RQQHFWLQJWKH:DWHU/LQH
7XUQRIIPDLQZDWHUVXSSO\7XUQRQQHDUHVWIDXFHWORQJ
HQRXJKWRFOHDUOLQHRIZDWHU
8VLQJD¹⁄₂FRSSHUVXSSO\OLQHZLWKDTXDUWHUWXUQVKXWRII
YDOYHRUWKHHTXLYDOHQWFRQQHFWWKHLFHPDNHUDVVKRZQ
127(7RDOORZVXIILFLHQWZDWHUIORZWRWKHLFHPDNHUD
PLQLPXP¹⁄₂GLDPHWHUKRPHVXSSO\OLQHLVUHFRPPHQGHG
1RZ\RXDUHUHDG\WRFRQQHFWWKHFRSSHUWXELQJ8VH¹⁄₄
PP2'VRIWFRSSHUWXELQJIRUWKHFROGZDWHUVXSSO\
■(QVXUHWKDW\RXKDYHWKHSURSHUOHQJWKQHHGHGIRUWKH
MRE%HVXUHERWKHQGVRIWKHFRSSHUWXELQJDUHFXW
VTXDUH
■6OLSFRPSUHVVLRQVOHHYHDQGFRPSUHVVLRQQXWRQFRSSHU
WXELQJDVVKRZQ,QVHUWHQGRIWXELQJLQWRRXWOHWHQG
VTXDUHO\DVIDUDVLWZLOOJR6FUHZFRPSUHVVLRQQXWRQWR
RXWOHWHQGZLWKDGMXVWDEOHZUHQFK'RQRWRYHUWLJKWHQ
3ODFHWKHIUHHHQGRIWKHWXELQJLQWRDFRQWDLQHURUVLQNDQG
WXUQRQPDLQZDWHUVXSSO\DQGIOXVKRXWWXELQJXQWLOZDWHULV
FOHDU7XUQRIIVKXWRIIYDOYHRQWKHZDWHUSLSH
,03257$17$OZD\VGUDLQWKHZDWHUOLQHEHIRUHPDNLQJWKH
ILQDOFRQQHFWLRQWRWKHLQOHWRIWKHZDWHUYDOYHWRDYRLG
SRVVLEOHZDWHUYDOYHPDOIXQFWLRQ
%HQGWKHFRSSHUWXELQJWRPHHWWKHZDWHUOLQHLQOHWZKLFKLV
ORFDWHGRQWKHEDFNRIWKHLFHPDNHUFDELQHWDVVKRZQ
/HDYHDFRLORIFRSSHUWXELQJWRDOORZWKHLFHPDNHUWREH
SXOOHGRXWRIWKHFDELQHWRUDZD\IURPWKHZDOOIRUVHUYLFH
$ %XOE
% 1XW
$ &RPSUHVVLRQVOHHYH
% &RPSUHVVLRQQXW
& &RSSHUWXELQJ
A
B
B
C
A

2-8 n
INSTALLATION ANd OperATINg INSTrucTIONS
5HDU9LHZ
5HPRYHDQGGLVFDUGWKHVKRUWEODFNSODVWLFWXEHIURPWKH
HQGRIWKHZDWHUOLQHLQOHW
7KUHDGWKHQXWRQWRWKHHQGRIWKHWXELQJ7LJKWHQWKHQXWE\
KDQG7KHQWLJKWHQLWZLWKDZUHQFKWZRPRUHWXUQV'RQRW
RYHUWLJKWHQ
127(7RDYRLGUDWWOLQJEHVXUHWKHFRSSHUWXELQJGRHVQRW
WRXFKWKHFDELQHWVVLGHZDOORURWKHUSDUWVLQVLGHWKH
FDELQHW
,QVWDOOWKHZDWHUVXSSO\WXEHFODPSDURXQGWKHZDWHUVXSSO\
OLQHWRUHGXFHVWUDLQRQWKHFRXSOLQJ
7XUQVKXWRIIYDOYH21
&KHFNIRUOHDNV7LJKWHQDQ\FRQQHFWLRQVLQFOXGLQJ
FRQQHFWLRQVDWWKHYDOYHRUQXWVWKDWOHDN
'UDLQ3XPS,QVWDOODWLRQ
RQPRGHOVUHTXLULQJGUDLQSXPSLQVWDOODWLRQRQO\
'R1RW,QVWDOO2QWKH)ROORZLQJ0RGHOV
■0RGHOVWKDWKDYHDIDFWRU\LQVWDOOHGGUDLQSXPS
■0RGHOVWKDWGRQRWUHTXLUHDGUDLQSXPS
127(&RQQHFWGUDLQSXPSWR\RXUGUDLQLQDFFRUGDQFHZLWKDOO
VWDWHDQGORFDOFRGHVDQGRUGLQDQFHV,WPD\EHGHVLUDEOHWR
LQVXODWHGUDLQWXEHWKRURXJKO\XSWRGUDLQLQOHWWRPLQLPL]H
FRQGHQVDWLRQRQWKHGUDLQWXEH,QVXODWHGWXEHNLW3DUW1XPEHU
:LVDYDLODEOHIRUSXUFKDVH'UDLQSXPSLVGHVLJQHG
WRSXPSZDWHUWRDPD[LPXPKHLJKWRIIWP8VHRQO\
DSSURYHGGUDLQSXPSNLW3DUW1XPEHU$
.LW&RQWDLQV
■'UDLQSXPSNLW3DUW1XPEHU$
■⁵⁄₈,'[¹⁄₈GUDLQWXEHLFHPDNHUELQWRGUDLQSXPS
UHVHUYRLULQOHW
■¹⁄₂,'[IWPGUDLQWXEHKRVHGUDLQSXPSGLVFKDUJHWR
KRXVHKROGGUDLQ
■⁵⁄₁₆,'[FPYHQWWXEHGUDLQSXPSUHVHUYRLUYHQWWR
LFHPDNHUFDELQHWEDFN
■&DEOHFODPSVVHFXUHVYHQWWXEHWREDFNRILFHPDNHU
■[³⁄₈SXPSPRXQWLQJVFUHZVVHFXUHVGUDLQSXPSWR
EDVHSODWHDQGFODPSVWREDFNRILFHPDNHU
■⁵⁄₈VPDOODGMXVWDEOHKRVHFODPSVHFXUHVYHQWWRGUDLQ
SXPS
■⁷⁄₈ODUJHDGMXVWDEOHKRVHFODPSVHFXUHVGUDLQWXEHWRLFH
PDNHUELQDQGGUDLQSXPSUHVHUYRLULQOHW
■5HDUSDQHO
■,QVWUXFWLRQVKHHW
,I,FH0DNHU,V&XUUHQWO\,QVWDOOHG
127(,ILFHPDNHULVQRWLQVWDOOHGSOHDVHSURFHHGWRk'UDLQ
3XPS,QVWDOODWLRQyVHFWLRQ
3XVKWKHVHOHFWRUVZLWFKWRWKH2IISRVLWLRQ
8QSOXJLFHPDNHURUGLVFRQQHFWSRZHU
7XUQRIIZDWHUVXSSO\:DLWWRPLQXWHVIRUWKHLFHWRIDOO
LQWRWKHVWRUDJHELQ5HPRYHDOOLFHIURPELQ
8QVFUHZWKHGUDLQFDSIURPWKHERWWRPRIWKHZDWHUSDQ
ORFDWHGLQVLGHWKHVWRUDJHELQ$OORZZDWHUWRGUDLQ
FRPSOHWHO\5HSODFHGUDLQFDS6HHk'UDLQ&DSyLOOXVWUDWLRQ
'UDLQ&DS
,ILFHPDNHULVEXLOWLQWRFDELQHWVSXOOLFHPDNHURXWRIWKH
RSHQLQJ
'LVFRQQHFWZDWHUVXSSO\OLQH6HHk:DWHU6XSSO\/LQHy
LOOXVWUDWLRQ
$ &RSSHUWXELQJ
% :DWHUVXSSO\WXEHFODPS
& ,QOHWZDWHUWXEHFODPSDQG
VXSSO\OLQHFRQQHFWRU
$ /LQHWRLFHPDNHU
% 1XWSXUFKDVHG
& )HUUXOHSXUFKDVHG
' 6XSSOLHGOLQHIURPLFHPDNHU
A
C
B
DA B C
$ 'UDLQFDS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
Ice Production
Ice Quality
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
PROBLEMRECOMMENDED SOLUTIONS
Ice Maker Runs But Produces
No IceCheck that the control is turned on.
Check that the water supply is properly connected and turned on.
If the drain cap is loose, water will empty from the water pan, and you will have either thin ice or no ice. Tighten
the drain cap.
Clean the drain tube.
Check that there are no kinks in the drain line.
Ice Maker Runs But Produces
Very Little IceIf the accelerated ice production feature is turned on, this feature increases the ice production rate to provide
you with more ice in the same amount of time.
Room temperatures of more than 90°F (32°C) will normally reduce ice production.
Dirt or lint may be blocking the airflow through the condenser.
If there is white scale buildup in the ice maker’s water or freezing system, you should clean the ice maker.
If the drain cap is loose, water will empty from the water pan, and you will have either thin ice or no ice. Tighten
the drain cap.
Ensure that the cutter grid is securely in place and that its harness plug is connected.
Check that water filter is properly installed.
PROBLEM RECOMMENDED SOLUTIONS
Off Taste, Odor or Gray Color
in the IceIf there is unusually high mineral content in the water supply, the water may need to be treated.
If there is mineral scale buildup, clean your ice maker.
Do not store any foods in the ice bin.
Make sure that all packaging materials were removed at the time of installation.
Thin, Soft or Clumps of Ice If there is unusually high mineral content in the water supply, the water may need to be treated.
If there is mineral scale buildup, clean your ice maker.
If there are clumps of ice in the bin and if ice is not used regularly, it will melt and formclumps. Break the clumps
with the ice scoop provided.

INSTALLATION ANd OperATINg INSTrucTIONS
n
2-9
:DWHU6XSSO\/LQH
'UDLQ3XPS,QVWDOODWLRQ
127('RQRWNLQNVPDVKRUGDPDJHWXEHVRUZLUHVGXULQJ
LQVWDOODWLRQ
8QSOXJLFHPDNHURUGLVFRQQHFWSRZHU
5HPRYHUHDUSDQHO6HHk5HDU3DQHOyLOOXVWUDWLRQIRUVFUHZ
ORFDWLRQV3XOOUHDUSDQHODZD\IURPWKHGUDLQWXEHDQG
GLVFDUG
5HDU3DQHO
5HPRYHWKHROGGUDLQWXEHDQGFODPSDWWDFKHGWRWKHLFH
PDNHUELQ
127('LVFDUGROGGUDLQWXEHDQGFODPS
,QVWDOOQHZGUDLQWXEH⁵⁄₈,'[¹⁄₈IURPLFHPDNHUELQWR
GUDLQSXPSUHVHUYRLULQOHWXVLQJQHZDGMXVWDEOHFODPSV6HH
k'UDLQ7XEHyLOOXVWUDWLRQ
127(6
■'RQRWNLQN
■7ULPWXEHOHQJWKLIUHTXLUHG
'UDLQ7XEH
,QVWDOOYHQWWXEH⁵⁄₁₆,'[>FP@WRGUDLQSXPS
UHVHUYRLUYHQW8VHRQH⁵⁄₈VPDOODGMXVWDEOHFODPSVXSSOLHG
6HHk3DUWV/RFDWLRQVyLOOXVWUDWLRQ
127('RQRWLQVWDOOKRXVHKROGGUDLQWXEHDWWKLVWLPH
3DUWV/RFDWLRQV
5HPRYHSRZHUFRUGFODPSDQGJURXQGVFUHZDWWDFKHGWR
LFHPDNHUSRZHUFRUGZKLFKLVPRXQWHGWRWKHXQLWEDVH
6HHk3DUWV/RFDWLRQVyLOOXVWUDWLRQ
127(&ODPSDQGVFUHZZLOOEHUHXVHG
6OLGHGUDLQSXPSLQWRWKHLFHPDNHUEDVHRQWKHULJKWVLGH
7KHSXPSPRXQWLQJWDEVKRXOGVOLSLQWRWKHUHFWDQJXODUVORW
LQWKHLFHPDNHUEDVH,WZLOOEHQHFHVVDU\WRWLSWKHSXPS
VOLJKWO\WRVOLSLQWRWKHVORW6HHk'UDLQ3XPS0RXQWLQJ7DE
6ORWyLOOXVWUDWLRQ
$ ¹⁄₄FRSSHUWXELQJ
% &DEOHFODPS
& ¹⁄₄FRPSUHVVLRQQXW
' )HUUXOHVOHHYH
( ,FHPDNHUFRQQHFWLRQ
$ 6FUHZORFDWLRQV
B
C
D
E
A
C
B
A
A
$ ⁷⁄₈DGMXVWDEOHKRVHFODPS
% 'UDLQWXEHLFHELQWRGUDLQSXPS
& ⁷⁄₈DGMXVWDEOHKRVHFODPS
' 'UDLQSXPSUHVHUYRLULQOHW
$ 9HQWWXEH
% ⁵⁄₈KRVHFODPS
& 'UDLQSXPSGLVFKDUJHWXEH
' 'UDLQSXPS
( ,FHPDNHUXQLWSRZHUFRUG
) [³⁄₈SXPSPRXQWLQJ VFUHZV
* 'UDLQSXPSSRZHUFRUGFODPS
DQGVFUHZ
A
B
C
D
A
B
C
D
E
FG

2-10 n
INSTALLATION ANd OperATINg INSTrucTIONS
'UDLQ3XPS0RXQWLQJ7DE6ORW
'UDLQ3XPS,QVWDOOHG
$OLJQWKHVFUHZKROHVDWWKHUHDURIWKHSXPS8VHWZR
ą[³⁄₈VFUHZVVXSSOLHG6HHk3DUWV/RFDWLRQVy
LOOXVWUDWLRQ
&RQQHFWGUDLQWXEHWRLFHPDNHUELQRXWOHW⁵⁄₈,'XVLQJ⁷⁄₈
DGMXVWDEOHFODPSVXSSOLHG6HHk'UDLQ7XEHyLOOXVWUDWLRQ
&RLOLFHPDNHUSRZHUFRUGLQWRDFPGLDPHWHUFRLO
:UDSHOHFWULFDOWDSHDURXQGWKHSRZHUFRUGLQVHYHUDO
SODFHVWRNHHSWKHFRUGLQDFRLO/RFDWHFRLOHGSRZHUFRUG
EHWZHHQWKHGUDLQSXPSDQGVLGHRIHQFORVXUHDQGSOXJLQWR
WKHUHFHSWDFOHRIWKHGUDLQSXPS6HHk3DUWV/RFDWLRQVy
LOOXVWUDWLRQ
$WWDFKWKHGUDLQSXPSSRZHUFRUGWRLFHPDNHUXQLWEDVH
ZLWKFODPSDQGVFUHZUHPRYHGLQ6WHSWKDWZDVXVHGWR
DWWDFKLFHPDNHUSRZHUFRUG6HHk3DUWV/RFDWLRQVy
LOOXVWUDWLRQ
3ODFHQHZUHDUSDQHOVPDOORQHIRULFHPDNHUVODUJH
RQHIRUDJDLQVWWKHEDFNRIWKHLFHPDNHU5RXWHWKH
YHQWWXEHDQGGUDLQSXPSGLVFKDUJHWXEHWKURXJKFXWRXWVLQ
WKHUHDUSDQHO
6HFXUHUHDUSDQHOZLWKRULJLQDOVFUHZV6HHk5HDU3DQHOy
LOOXVWUDWLRQ
6HFXUHYHQWWXEHWREDFNRILFHPDNHUXVLQJFODPSVDQG
WKUHH[³⁄₈VFUHZVVXSSOLHG6HHk9HQW7XEHy
LOOXVWUDWLRQ
9HQW7XEH
127('RQRWSLQFKNLQNRUGDPDJHWKHYHQWWXEH&KHFNWKDW
LWLVQRWGDPDJHGRUSLQFKHGRUNLQNHGEHWZHHQWKHFDELQHW
DQGWKHLFHPDNHU
$WWDFK¹⁄₂,'[IWPGUDLQWXEHWRSXPSGLVFKDUJH
WXEH6HHk3DUWV/RFDWLRQVyLOOXVWUDWLRQ
&RQQHFWLFHPDNHUWRZDWHUVXSSO\DQGLQVWDOOLFHPDNHUDV
VSHFLILHGE\WKHSURGXFWLQVWDOODWLRQLQVWUXFWLRQV
&KHFNDOOFRQQHFWLRQVIRUOHDNV
3OXJLQLFHPDNHURUUHFRQQHFWSRZHU
7XUQRQLFHPDNHU
:DLWIRUULQVLQJF\FOHDSSUR[LPDWHO\PLQXWHVWREHVXUH
WKHLFHPDNHULVRSHUDWLQJSURSHUO\
$ 0RXQWLQJWDEVORW
$ 'UDLQSXPSLQVWDOOHG
A
A
$ 9HQWWXEH
% &ODPSVDQGVFUHZV
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Ice Maker Operation
Scan the code at left with your mobile device, or visit
https://jennair.custhelp.com
for
recommendations that may help you avoid a service call.
Problem Solver
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
PROBLEMRECOMMENDED SOLUTIONS
Ice Maker Will Not Operate Check that it is plugged into a grounded 3 prong outlet.
Check that the control is turned on.
Replace the fuse or reset the circuit breaker.
NOTE:If problems continue, contact an electrician.
Room temperature must be above 55°F (13°C). Otherwise, bin thermostat may sense cold room temperature
and shut off even though the bin is not full of ice. The ice maker may not restart once it does shut off.
If there was a large amount of water added to the ice maker, wait a few minutes for the drain pump to clear. If
there is still water in the bin, check to see whether the drain hose is kinked.
For models with drain pumps, check that the drain hose is not damaged, or kinked or pinched between cabinet
and ice maker. Use only Whirlpool approved drain pump kit, Part Number 1901A.
Ice Maker Seems NoisyWater overflowing the reservoir is normal. This overflow helps to purge minerals that were removed from the
water during the ice making process.
If there is a “whooshing” sound, check the following things:
■Make sure that the water supply is hooked up and turned on.
■Make sure that the drain cap is tight and the water drain pan pump is securely attached to the water pan.
If there is ice between the evaporator plate and the cutting grid, check that the ice maker is level. If the ice
maker is level, and the problem persists, run a cleaning cycle.
If the ice maker is connected to a water supply pressure in excess of 60 psi, you may hear a loud sound during
water filling associated with the flow of water through the inlet valve. Call a licensed, qualified plumber to
determine the best method to reduce the supply water pressure (50 psi is recommended).

INSTALLATION ANd OperATINg INSTrucTIONS
n
2-11
'UDLQ&RQQHFWLRQ
*UDYLW\'UDLQ6\VWHP
&RQQHFWWKHLFHPDNHUGUDLQWR\RXUGUDLQLQDFFRUGDQFHZLWK
DOOVWDWHDQGORFDOFRGHVDQGRUGLQDQFHV,IWKHLFHPDNHULV
SURYLGHGZLWKDJUDYLW\GUDLQV\VWHPIROORZWKHVHJXLGHOLQHV
ZKHQLQVWDOOLQJGUDLQOLQHV7KLVZLOOKHOSNHHSZDWHUIURP
IORZLQJEDFNLQWRWKHLFHPDNHUVWRUDJHELQDQGSRWHQWLDOO\
IORZLQJRQWRWKHIORRUFDXVLQJZDWHUGDPDJH
■'UDLQOLQHVPXVWKDYHDPLQLPXPRI⁵⁄₈ PPLQVLGH
GLDPHWHU
■'UDLQOLQHVPXVWKDYHDGURSSHU FPGURSSHU
FPRIUXQRU¹⁄₄GURSSHUPPSHUFP
RIUXQDQGPXVWQRWKDYHORZSRLQWVZKHUHZDWHUFDQVHWWOH
■7KHIORRUGUDLQVPXVWEHODUJHHQRXJKWRDFFRPPRGDWH
GUDLQDJHIURPDOOGUDLQV
■7KHLGHDOLQVWDOODWLRQKDVDVWDQGSLSHZLWKD¹⁄₂FP
WR FP39&GUDLQUHGXFHULQVWDOOHGGLUHFWO\EHORZ
WKHRXWOHWRIWKHGUDLQWXEHDVVKRZQ<RXPXVWPDLQWDLQD
FPDLUJDSEHWZHHQWKHGUDLQKRVHDQGWKH
VWDQGSLSH
,03257$17$GUDLQSXPSLVQHFHVVDU\ZKHQDIORRUGUDLQLV
QRWDYDLODEOH$'UDLQ3XPSNLW3DUW1XPEHU$LV
DYDLODEOHIRUSXUFKDVH
6LGH 9LHZ
'UDLQ3XPS6\VWHPRQVRPHPRGHOV
,03257$17
■&RQQHFWWKHLFHPDNHUGUDLQWR\RXUGUDLQLQDFFRUGDQFH
ZLWKWKH,QWHUQDWLRQDO3OXPELQJ&RGHDQGDQ\ORFDOFRGHV
DQGRUGLQDQFHV
■7KHGUDLQSXPSGLVFKDUJHOLQHPXVWWHUPLQDWHDWDQRSHQ
VLWHGGUDLQ
■0D[LPXPULVHIWP
■0D[LPXPUXQIWP
127(6
■,IWKHGUDLQKRVHEHFRPHVWZLVWHGDQGZDWHUFDQQRWGUDLQ
\RXULFHPDNHUZLOOQRWZRUN
■,WPD\EHGHVLUDEOHWRLQVXODWHWKHGUDLQOLQHWKRURXJKO\XS
WRWKHGUDLQLQOHW$Q,QVXODWLRQ6OHHYHNLW3DUW1XPEHU
:LVDYDLODEOHIRUSXUFKDVH
&RQQHFWLQJWKH'UDLQ
$IWHUHQVXULQJWKDWWKHGUDLQV\VWHPLVDGHTXDWHIROORZWKHVH
VWHSVWRSURSHUO\SODFHWKHLFHPDNHU
3OXJLQWRDJURXQGHGSURQJRXWOHW
6W\OH)RUJUDYLW\GUDLQV\VWHPSXVKWKHLFHPDNHULQWR
SRVLWLRQVRWKDWWKHLFHPDNHUGUDLQWXEHLVSRVLWLRQHGRYHU
WKH39&GUDLQUHGXFHU6HHk*UDYLW\'UDLQ6\VWHPy
6W\OH)RUGUDLQSXPSV\VWHPFRQQHFWWKHGUDLQSXPS
RXWOHWKRVHWRWKHGUDLQ6HHk'UDLQ3XPS6\VWHPy
5HFKHFNWKHLFHPDNHUWREHVXUHWKDWLWLVOHYHO6HH
k/HYHOLQJy
,ILWLVUHTXLUHGE\\RXUORFDOVDQLWDWLRQFRGHVHDOWKH
FDELQHWWRWKHIORRUZLWKDQDSSURYHGFDXONLQJFRPSRXQG
DIWHUDOOZDWHUDQGHOHFWULFDOFRQQHFWLRQVKDYHEHHQPDGH
$ 'UDLQKRVH
% FPDLUJDS
& 39&GUDLQUHGXFHU
' &HQWHURIGUDLQVKRXOGEHFP
IURPIURQWRIGRRUZLWKRUZLWKRXWWKH³⁄₄
FPSDQHORQWKHGRRU7KHGUDLQ
VKRXOGDOVREHFHQWHUHGIURPOHIWWRULJKW
⁵⁄₁₆> FP@IURPHLWKHUVLGHRIWKH
LFHPDNHU
1⁷⁄₈"
(4.8 cm)
23"
(58.4 cm)
2" - 1¹⁄₂"
(5 cm - 3.8 cm)
1" (2.54 cm)
A
D
C
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
Plumbing Problems
Ice Maker Water Filtration System
Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI Standards 42.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
■It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
■Use replacement filter P6RFWG2K, P6RFGEG2K, P6RFKG2K, Part
Number ICE2.
Style 1 – When the water filter status display changes from “GOOD”
to “ORDER,” order a new filter. When the filter indicator reads
“REPLACE,” it is recommended that you replace the filter.
Style 2 – Press FILTER to check the status of your water filter. If the
filter indicator light is yellow and the words “ORDER FILTER” appear
on the display screen, order a new filter. If the filter indicator light is
red, it is recommended that you replace the filter.
■These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
■Refer to the “Warranty” section for the Manufacturer’s name, address
and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
PROBLEM RECOMMENDED SOLUTIONS
Water Not Entering Drain
ProperlyIf the drain hose is not aligned over the drain, move the ice maker to align the drain.
NOTE:Service technicians cannot repair plumbing problems outside of the ice maker. Call a licensed, qualified
plumber.
System tested and certified by NSF
International against NSF/ANSI
Standard42 for the reduction of
Chlorine Taste and Odor.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Ta ste/Odor 50% reduction 1.9727 mg/L 2.0 mg/L ± 10% 0.71 mg/L 0.7788 mg/L 70.2 72.81
Performance Data Sheet
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.50 gpm (1.89 Lpm) @ 60 psi
® NSF is a registered trademark of NSF International.
Ice Maker Operation
Scan the code at left with your mobile device, or visit
https://jennair.custhelp.com
for
recommendations that may help you avoid a service call.
Problem Solver
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
PROBLEMRECOMMENDED SOLUTIONS
Ice Maker Will Not Operate Check that it is plugged into a grounded 3 prong outlet.
Check that the control is turned on.
Replace the fuse or reset the circuit breaker.
NOTE:If problems continue, contact an electrician.
Room temperature must be above 55°F (13°C). Otherwise, bin thermostat may sense cold room temperature
and shut off even though the bin is not full of ice. The ice maker may not restart once it does shut off.
If there was a large amount of water added to the ice maker, wait a few minutes for the drain pump to clear. If
there is still water in the bin, check to see whether the drain hose is kinked.
For models with drain pumps, check that the drain hose is not damaged, or kinked or pinched between cabinet
and ice maker. Use only Whirlpool approved drain pump kit, Part Number 1901A.
Ice Maker Seems NoisyWater overflowing the reservoir is normal. This overflow helps to purge minerals that were removed from the
water during the ice making process.
If there is a “whooshing” sound, check the following things:
■Make sure that the water supply is hooked up and turned on.
■Make sure that the drain cap is tight and the water drain pan pump is securely attached to the water pan.
If there is ice between the evaporator plate and the cutting grid, check that the ice maker is level. If the ice
maker is level, and the problem persists, run a cleaning cycle.
If the ice maker is connected to a water supply pressure in excess of 60 psi, you may hear a loud sound during
water filling associated with the flow of water through the inlet valve. Call a licensed, qualified plumber to
determine the best method to reduce the supply water pressure (50 psi is recommended).
This manual suits for next models
3
Table of contents
Other Kenmore Ice Maker manuals
Popular Ice Maker manuals by other brands

Viking
Viking 15"W installation guide

U-Line
U-Line Origins BI-98 Specifications

Hoshizaki
Hoshizaki FM-600AKE instruction manual

Hoshizaki
Hoshizaki KM-2100SWH3 instruction manual

Follett
Follett HCC1400A Operation and service manual

Manitowoc
Manitowoc F-STYLE OR NON MANITOWOC BIN 7601193 installation instructions