Kentrox DataSmart 486 User manual

DataSMART® 486 and 488
E1/FE1 Frame Monitoring DSU/CSUs
E1/FE1 Frame Monitoring
DSU/CSUsProvideend-to-endcircuit
monitoringforFrameRelay
networks
nIdentifywhenbandwidth
adjustmentsareneeded
nIsolatethesource of slow
networkperformance:the
LAN,localloop,orWAN
nG.704performancemonitoring
for E1 services
nX.21/V.35dataportavailable
foravarietyofequipment
nAdd/drop voice port available
forvoice and data traffic
integration
nStandards-based,in-band
managementwithSNMP
nEasylocalmanagement with
10Base-Taccess and
front-panelLCD
nFreeDataSMART®Installer
andAlarmsUtilitysoftware
n5-yearmanufacturer’s
warrantyensuresreliability
DataSMART E1/FE1
Frame Monitoring
DSU/CSUs provide
comprehensive, easy-
to-use, end-to-end
circuit monitoring to
improve Frame Relay
network performance.
WithDataSMARTFrameMonitoringDSU/CSUs,
service providers and network managers have the tools
todeliverreliable,high-performance Frame Relay
services. Frame Monitoring DSU/CSUs help verify
Service Level Agreements between the PTT and
customer, match bandwidth to application needs, and
isolate performance problems to the LAN, the WAN, or
the local loop.
DataSMARTDSU/CSUsmaximizeyour network
uptime with convenient management features, such as
in-bandaccessforsimplifiedremotemanagement.
Each DSU/CSU includes an integrated Ethernet port and
a front-panel LCD for easy local management, along with
standards-basedSNMP management.
DataSMARTE1/FE1FrameMonitoringDSU/CSUs,
teamedwith FrameVision Reporter software, deliver the
tools and information necessary to ensure ongoing
savings – and a quick return on investment.

DataSMART
E1/FE1Frame MonitoringDSU/CSUs
Page2
The DataSMART 486 and 488 support FrameVision Reporter software to deliver key
performance measurements on individual customer circuits.
Verify Frame Relay performance
DataSMART Frame Monitoring
DSU/CSUs help you isolate circuit
availabilityproblems andmeasure
round-trip delay from DSU to DSU.
You can see the exact time a service
outage occurred and how long it
lasted, to determine if it was an
isolated incident or a chronic problem.
You can monitor bandwidth utilization
at the port and virtual circuit to deter-
mine the right bandwidth to meet your
application requirements.
Advanced management and
diagnostics
The DataSMART DSU/CSUs have
advanced management features that
enable you to take active control of
your network, such as in-band SNMP
management and an integrated
Ethernet port. Comprehensive E1
diagnostic tools help you identify and
resolve performance issues in the
Frame Relay local loop before they
affect service. With the DataSMART,
you can remotely configure your units,
and receive SNMP traps for important
network events.
Standards-basedManagement
The DataSMART embedded SNMP
agent supports SETs, GETs and Traps,
as well as standard MIBs, such as
MIB II and the E1 MIB. And for compre-
hensive control, an enterprise MIB
supports all available functions. These
MIBs are available on the ADC Kentrox
web site (www.kentrox.com).
DataSMART Installer forWindows
Free with each unit, DataSMART
Installer software is an intuitive,
Windows-based utility that
dramatically reduces setup time.
Alarms Utility
Downloadable free from
www.kentrox.com, Alarms Utility
monitors the entire network for inter-
face and device errors, posting them to
the event log in an HP OpenView
management system. Customer icons
uniquely identify all ADC Kentrox
devices for easy recognition by the
Network Node Manager.
The DataSMART 488 integrates voice and data traffic onto a single E1/FE1 line.
With in-band management and local Ethernet connectivity, the DataSMART 486 and
488 can be managed easily from a remote or local site. The management system
can be located anywhere on the business network.
DataSMART E1/FE1 Frame Monitoring DSU/CSU Product Portfolio:
DATA
NETWORK USER NETWORK OR VIDEO VOICE RATES
PHYSICAL INTERFACE PROTOCOLS USER PORTS
DataSMART486 E1 X.21 ClearChannel 1 0 Nx64k,
Single-Port FE1 V.35 FrameRelay 2.048 Mbps
EIA-530
RS449
DataSMART488 E1 X.21 ClearChannel 1 1 Nx64k,
Single-Port FE1 V.35 FrameRelay 2.048 Mbps
Add/Drop EIA-530
RS449
E1/FE1

Page3
E1/FE1FrameMonitoringDSU/CSUs
NETWORK INTERFACE
LineRate E1 (2048 Kbps) + 50 ppm
Framing G.704
LineCode HDB3
Protocol ClearChannel
FrameRelay
LineImpedance
120Ω+10Ωat 1024 KHz
75Ω+10Ωat 1024 KHz
MechanicalDA15 socket for 120Ω
Adapter for 75ΩBNC
LightningProtection
120Ω interface withstands lightning
surges defined per FCC Part 68, and
unit recovers
TERMINAL INTERFACE (DataSMART 488)
LineRate E1 (2048 Kbps) + 50 ppm
Framing G.704
LineCode HDB3
Protocol ClearChannel(DS0)
LineImpedance
120Ω+10Ωat 1024 KHz
75Ω+10Ωat 1024 KHz
MechanicalDA15 socket for 120Ω
Adapter for 75ΩBNC
DATA PORT INTERFACE
BitRate Nx64 kbps (N=1...31)
Electrical V.35 compatible
X.21 via adapter
V.11/X.27/EIA-530
MechanicalDB25 socket
MANAGEMENT
ControlPorts
DCEandDTE
EIA-574
DE9 socket
Daisy chain
38.4 kbps maximum
Englishmenus
Async ASCII or SLIP/PPP
EthernetPort
10Base-T RJ45 socket
Transmit and receive LEDs
SNMPAgent
MIB II (RFC 1213)
DS1/E1MIB(RFC1406)
FrameRelayMIB(RFC1315)
Enterprise MIB*
TELNETserver
Responds to Ping
Security filters
(for IP source addresses)
Up to 10 SNMP Trap hosts
In-band From network or router
Shared or dedicated VC
Frame Relay or ATM DXI
LCDFront panel display of unit status
Front panel configuration of unit
ALARMS
Traps SNMP Traps via SLIP/PPP, Ethernet or
in-band
ASCII Transmitted out async control port
FRAME RELAY CIRCUIT MANAGEMENT
Methodology
Non-intrusive,in-band
Virtual Circuit (VC)Traffic
Group Measurements: % bandwidth
utilization, kbps, delays, VC status
(24hour)
Detail: Frames, octets, kbps, delay
measurements, VC status
VCStatus Up, down, BECN set, FECN set, DE set,
bandwidth utilization threshold exceeded,
delay threshold exceeded
VCTraffic Detail Measurement Intervals
Current/previous second; cur/prev 15
min; cur/prev 2 hour; cur 24 hour;
previous 7 complete days, 12 2-hour
intervals for current day
VCDelay Measurements
Maximum observed delay, average delay,
attempts made, measurement packets
lost Automatic delay measurements for
up to 64 active VCs
VCDelay Diagnostics
Round-trip VC delay via in-band
FrameRelayPerformanceThresholds
User configurable
Access bandwidth utilization
Round-trip delay
Frame Relay Statistics
Non-integral number of octets
Invalid header address
InvalidHDLC FCS
Aborted frames
FPING responses lost (system total)
Reports Frame statistical
Framegroup(VC summary)
Frameindividual (VC detail)
Frame VC utilization
Burst: data sent above CIR and above
excess burst rates
LOCAL LOOP DIAGNOSTICS
LoopTestsLine loopback
Payload loopback
Data port loopback
LineTest Codes
223-1, 215-1, QRS, 3-in-24, 1-in-8, All 1s,
All 0s
DataTest Codes
511, 2047
BERTTester
Independent BERT on all test codes
LOCAL LOOP
PERFORMANCE MONITORING
DataStorage
Last 24 hours of data in 15 minute
increments; last 7 days of data in
24-hour increments
Monitors Network and terminal interface
Reports Based on G.821 for performance
Far end
Alarm history
Network interface statistical
Terminal interface statistical
(add/drop only)
DIAGNOSTICS
LEDs Power/fail
E1
Data port transmit
Data port receive
Dataport CTS
Dataport RTS
LoopTestsLocal loopback
Data terminal loopback
Terminal interface loopback
(add/drop only)
STANDARDS
EN60590
EN55022 Class B
EN50081-2
ITU G.703, G.704, G.821
BABTNTR4, CTR12,CTR13
REGULATORY (Call for current status)
ACNAustralian Communications Authority and
SpectrumManagement
BABTNTR4
CE 0682
_
X
_
TUVGS
ENVIRONMENT
Operating 0° to 50° C
5% to 90% RH, non-condensing
Storage -20° to 66° C
5% to 65% RH
POWER
AC85-265VAC, 47-63 Hz, 8W
PHYSICAL
Usage Desktop or tray mount
Dimensions19.68 cm W x 4.32 cm H x 29.21 cm D
Weight 1.14 kg (approx.)
*MIB files available at www.kentrox.com.
Specifications

DataSMART
E1/FE1Frame MonitoringDSU/CSUs
Worldwide Sales Offices
Corporate
Headquarters +1-503-643-1681
Australia +61-2-9975-1499
Belgium +32-2-712-6555
Canada +1-905-629-3104
China +86-10-65007001
Germany +49-211-53065530
Korea +82-2-333-8989
Latin America +1-310-640-2922
Singapore +65-227-5621
UnitedKingdom +44-1705-481691
ADCKentrox
14375 NW Science Park Drive
Portland, Oregon 97229
(800)733-5511
(503)643-1681
FAX(503)641-3341
WebSite www.kentrox.com
E-mail [email protected]
Pre-sales Support (800)733-5511
Literature Hotline (800)232-5879
Copyright1998,ADCKentrox.AnEqualOpportunityEmployer.DataSMART is a registeredtrademarkandFrameVision is a trademarkof
KentroxIndustries,Inc.,dba ADC Kentrox.ADCKentroxisa registered trademarkofADCTelecommunications,Inc.Thesetrademarks
areregisteredintheU.S.PatentandTrademarkOfficeandmayberegisteredinothercountries.Allothertrademarksmentionedarethe
propertyoftheirrespectivecompanies.Specificationspublishedherearecurrentorplannedasofthedateofpublication.ADCKentrox
reservestherighttochangespecificationswithoutpriornotice.Youmayverifyproductspecifications by contacting anyofouroffices.
8/98 05-04-007
OrderingGuide
Description Model No.
FrameMonitoringDSU/CSUs
DataSMART486 E1/FE1 72486
FrameMonitoringDSU/CSU
DataSMART488 E1/FE1Add/Drop 72488
FrameMonitoringDSU/CSU
MountingAccessories
Mounting Tray, 1 Stand-alone unit 78031
Managementand ReportingSoftware
FrameVisionReporter 70304
DataSMARTInstaller 70305
Alarms Utility 70451
*Call for availability.
1
2
3
BackPanel & Cable Guide
To Network andTerminal Equipment
930xx091 DA15P to DA15S
930xx101 DA15P to Stub
930xx121 DA15P to RJ48C Modular Plug
930xx131 DA15P to DA15P
77892 DA15P to RJ48C Socket Adapter
77895 DA15P to 2 x 75 ohm Socket Coaxial
Adapter
960xx009 BNC Plug to BNC Socket
960xx010 BNC Plug to BNC Plug
93005132 DA15P to DA15P, Crossover
77993003 DA15P to Barrier Strip Adapter
ToControlTerminal
95006022 DE9S to DE9P, 6 ft. (2.4 m)
95005023 DE9S to DB25P, 5 ft. (2 m)
93001211 DE9P to RJ48, Cisco 2500 SLIP
ToControl Port
78899 DE9S to RJ45 Adapter
78891 DataSMART Installation Kit
4
ToData Equipment
V.35
95010054 DB25P to MRAC34P, 10 ft. (4 m)
95010073 DB25P to MRAC34P, tail circuit timing
(DCEto DCE)
95001074 DB25P to MRAC34S, 1 ft. (0.4 m)
78904 DB25PtoMRAC34S Adapter
X.21
78902 DB25P to DA15S, X.21 Adapter
95010061 DB25P to DB25P, 10 ft. (4 m)
95010058 DB25P to DB25P, tail circuit timing (DCE
toDCE)
95010066 DB25P to DC37P (EIA-530 to RS449)
To 10Base-T LAN
95007077 RJ45 Plug to RJ45 Plug,
Cat. 3 UTP, 7 ft. (2.8 m)
95007078 RJ45 Plug to RJ45 Plug, Crossover,
Cat. 3 UTP, 7 ft. (2.8 m)
NOTE: xx denotes length of cable, contact factory
for available lengths. DA, DB, DC, DE designate the
size of the shell which encapsulates the cable
connector.
P = Plug (male); S = Socket (female).
*
3 42
1
3 42
1 1
DataSMART 486 E1/FE1
Frame Monitoring DSU/CSU
DataSMART 488 E1/FE1 Add/Drop
Frame Monitoring DSU/CSU
This manual suits for next models
5
Table of contents
Other Kentrox Network Hardware manuals