11
KDC-1032/132/132CR
KDC-133/233/234SGY
ADJUSTMENT
1.
IC10 (X34-) -TheTuner adjustment method
• When IC10 and its circumference are repaired, according
to the following order, it readjusts if needed.
• The adjustment item changes with parts to exchange.Please
refer to "Parts vs Adjustment item table".
1-1.
VCO coil adjustment - adjustment of tunning voltage
Voltage Check Point :Vt-Check Land
(PWB Side B, around D506)
Adjustment Coil :L507 (VCO Coil)
The adjustment method :VCO coil is turned and adjusted
according to the following tables.
Type Mode freq. Voltage Fig.
E/M AM 1611kHz 5.5 ±0.1(V) 2, 3 (C)
KAM1700kHz 5.8 ±0.1(V) 2, 3 (C)
JFM90.0MHz 5.6 ±0.1(V) 2, 3 (C)
M : AM Adjustment
ForYour Information :The frequency of this unit is only set
up by preset key in case this adjustment
1-2. Adjustment of 1st & 2nd-MIX coil
Voltage Check Point : S-METER-Check Land
(PWB Side B, around W572)
Adjustment Coil : 1
st IFT=L508 / 2nd IFT=L509
Setting of Signal Generator : Refer to the following tables
Type Mode freq. Mod. ANT Input Fig.
KAM1000kHz OFF 35dBµEMF 1~3 (B),(C)
E/M/J AM 999kHz OFF 35dBµEMF 1~3 (B),(C)
qThe appearance and the coil with which S-METER DC volt-
age serves as the maximum are turned and adjusted in the
above-mentioned SG input.
wBy the above-mentioned adjustment method, same adjust-
ment is performed to both sides (1st & 2nd MIX Coil).
1-3. Adjustment of FM ANT & RF coil
Voltage Check Point : S-METER-Check Land
(PWB Side B, around W572)
Adjustment Coil : ANT Coil = L505
RF Coil = L506
Setting of Signal Generator : Refer to the following tables
Type Mode freq. Mod. ANT Input Fig.
E/M FM 87.5MHz OFF 5 or 11dBµEMF 1~3 (A),(C)
KFM87.9MHz OFF 5 or 11dBµEMF 1~3 (A),(C)
JFM76.0MHz OFF 5 or 11dBµEMF 1~3 (A),(C)
qThe appearance and the coil with which S-METER DC volt-
age serves as the maximum are turned and adjusted in the
above-mentioned SG input.
wBy the above-mentioned adjustment method, same adjust-
ment is performed to both sides (ANT & RF Coil).
1-4.
Adjustment of STEREO (adjustment of 456k-VCO)
Adjust in TEST MODE
• How to enter the test mode
While pressing on [FM] and Preset [6] keys, reset the unit.
• Adjustment method
Complete on condition that show “STANDBY” when press-
ing on Preset [1] and Preset [6] keys for 1 second or more.
(Writing adjustment valve to the E2PROM.)
Effect of adjustment is in cofirmation of adjustment status
at Preset [4] key.
• Display of Preset [4]
Adjustment OK:“EPO” (7-segment LCD model)
Adjustment NG:“EPE” (7-segment LCD model)
• Releasing the test mode
Reset mode only.
ACC off, Power off, Power down and Remove the panel
mode is not releasing.
[Fig.3]
(UNDER VIEW)
[Fig.2]
[Fig.1]
(OVER VIEW)
(REAR VIEW)
(TUNER ANT)
(A)
(B)
S-METER
Check Land
IC10
Vt
Check Land
FM-SG
AM-SG
(C)DC Voltmeter
L509
L508
L507
L506
L505