manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. KEST
  6. •
  7. Security Sensor
  8. •
  9. KEST KT-B10W User manual

KEST KT-B10W User manual

HEAD QUARTER :
Address : No.25 Baoyuan Road Dongqian Lake Industry Area ,Dongqian Town Ningbo City / C INA
Phone : 0086 574 88366066 - Fax : 0086 574 88327726
KEST TURKEY :
Adress : İstoç 37 Ada No:5 Bağcılar / İSTANBUL
Phone : +90 (212) 659 50 98 - (212) 659 45 29 - Fax : +90 (212) 659 39 77
KT-B10W Dual Passive Infrared Detector
SPECIFICATIO S
o. Items Specification
1 Operating voltage 9.5VDC~14.5VDC
2 Supply voltage ripple 3.0Vpp@ 12VDC
3 Standby current 16mA
4 Current in alarm 20mA
5 Operating temp. 0~50
6 Storage temp. -40~60
7 Operating humidity 5~95% RH.
8 Storage humidity up to 99% RH.
9 RF immunity 10V/m with 80% AM from 80MHz~1GHz
10 Static immunity 8kV contact 15kV air
12 Transient immunity 2.4kV@ 1.2 joules
13 Walk detection speed 0.15~3.0 m/s
14 Coverage angle 75°(Min.)/90°(Max.)
15 Mounting heights 1.8~3.2M
I STALLATIO
To open the case, use a small flat blade screwdriver and gently push in the tab at the bottom of the case and lift the
cover upwards.
Bracket Mounting Pull back the PCB retaining clip on the right hand side of the housing and lift out the PCB.
Hold the rear housing down on its back on a flat surface. Position the blade of a flat head screwdriver at the mid
point of the groove located between the housing and the swivel knockout. Press down on the screwdriver to pierce
HEAD QUARTER :
Address : No.25 Baoyuan Road Dongqian Lake Industry Area ,Dongqian Town Ningbo City / C INA
Phone : 0086 574 88366066 - Fax : 0086 574 88327726
KEST TURKEY :
Adress : İstoç 37 Ada No:5 Bağcılar / İSTANBUL
Phone : +90 (212) 659 50 98 - (212) 659 45 29 - Fax : +90 (212) 659 39 77
the plastic, then pry upwards to break off the knockout. Remove any rough edges. Feed the system wiring through
the back of the swivel bracket. Secure the bracket in the desired position. With the bracket firmly mounted, position
the socket of the rear housing over the ball of the bracket. Install the washer over the threaded wire conduit making
sure that the pivot pin of the washer is seated in it’s socket on the rear housing. Install the securing nut and tighten
just enough to hold all components together. Re-install and wire up the PCB according to the instructions below.
Adjust the orientation of the housing and set the vertical adjustment of the PCB to the zero position. ext, insert
and tighten the retaining screw. Then, tighten the securing nut.
Wall Mounting If you swivel mount is not being used, use a small screwdriver to remove the appropriate
mounting screw and wiring entrance knockouts from the back plate. Mount the back plate to the wall. Wire up and
re-install the PCB according to the instructions below and adjust the vertical adjustment.
Re-installing the PCB Position the PCB into the notches along the left hand side of the housing and press the
PCB down under the right hand side retainer clip. Set the vertical adjustment; nest insert and tighten the retaining
screw provided
Vertical Adjustment Using the Mounting Height Chart, set the vertical adjustment for the desired coverage. The
height will be indicated by the gauge located at the bottom left hand corner of the circuit board. Ensure that the
PCB retaining screw is tightened just enough to prevent board movement. Moving the circuit board down will
increase the far range and move the near beams farther out from the mounting wall. Moving the circuit board up
will reduce the far range and bring the near beams closer to the mounting wall. Moving the board down too much
will cause the far beams to “look” above the target. As a result, the range may appear shorter.
NOTERange and dead zones may vary due to settings.
Jumpers There are two jumpers on the detector circuit board. Jumper J1 will enable/disable the alarm LED. If J1
is OFF, the LED will not operate on alarm. If J1 is O the LED will operate on alarm. Upon power up, if J1 is O ,
the LED will turn on for approximately one minute to indicate the warm-up period. Jumper J2 is used to configure
the detector to weight of the pets and the installation condition. For an environment with a single animal whose
weight does not exceed 13.6Kg the unit should be set to NORMAL (J2 ON). In an environment with single or
multiple pets whose combined weight is greater than 13.6Kg and not greater than 27.3Kg set J2 to HOSTILE (J2
HEAD QUARTER :
Address : No.25 Baoyuan Road Dongqian Lake Industry Area ,Dongqian Town Ningbo City / C INA
Phone : 0086 574 88366066 - Fax : 0086 574 88327726
KEST TURKEY :
Adress : İstoç 37 Ada No:5 Bağcılar / İSTANBUL
Phone : +90 (212) 659 50 98 - (212) 659 45 29 - Fax : +90 (212) 659 39 77
OFF). When the detector is mounted 1.9 to 2.3M or there is the possibility of the pet getting higher than 1.2M the
HOSTILE setting must be used
Walk esting Place the animal within the coverage area of the detector and then move out of the zone. Encourage
the pet to move around as it normally would and ensure that it moves across the detection pattern of the detector.
Verify that no alarm is initiated. To test for catch performance of humans, create motion in the entire area where
coverage is desired by walking perpendicular to the lens pattern. Should the coverage be incomplete, readjust or
relocate the detector. Once coverage is as required, the alarm LED may be disabled by setting J1 to OFF
IMPORTANT NOTEUpon installation, t e unit s ould be t oroug ly tested to verify proper operation.
T e detector s ould be walk tested weekly by t e end user and annually by t e installer.
OTICE
Select a detector location that will provide the coverage required. Consider the following to avoid false alarms
Do not aim the detector at reflective surfaces such as mirrors or windows as this may distort the coverage pattern or
reflect sunlight directly onto the detector. Avoid locations that are subject to direct high air flow such as near on air
duct outlet.
Do not locate the detector near sources of moisture such as steam or oil.
Do not limit the coverage by placing large obstructions in the detection area, such as plants or cabinets.

Popular Security Sensor manuals by other brands

Lambrecht aem 24513 user manual

Lambrecht

Lambrecht aem 24513 user manual

Lince Bobby Technical manual

Lince

Lince Bobby Technical manual

Visonic SR-740 HEX PG2 installation instructions

Visonic

Visonic SR-740 HEX PG2 installation instructions

Vision-EL 75501 instructions

Vision-EL

Vision-EL 75501 instructions

Fireye FLAME SIGNATURE SCANNER 1000 manual

Fireye

Fireye FLAME SIGNATURE SCANNER 1000 manual

Argus Security VCP100 manual

Argus Security

Argus Security VCP100 manual

SKF TKED 1 Instructions for use

SKF

SKF TKED 1 Instructions for use

SMART Notebook 10 manual

SMART

SMART Notebook 10 manual

GJD D-TECT X 50 MKIII quick start guide

GJD

GJD D-TECT X 50 MKIII quick start guide

Sealey VS0062 instructions

Sealey

Sealey VS0062 instructions

Detection Systems DS1525 installation manual

Detection Systems

Detection Systems DS1525 installation manual

Niko 550-20200 manual

Niko

Niko 550-20200 manual

Omron F39-PTG instruction sheet

Omron

Omron F39-PTG instruction sheet

Satel abax 2 ADD-200 manual

Satel

Satel abax 2 ADD-200 manual

CWSI 360 user manual

CWSI

CWSI 360 user manual

Viessmann CO detector Installation and service instructions for contractors

Viessmann

Viessmann CO detector Installation and service instructions for contractors

MSA Ultra Elite-PF operating manual

MSA

MSA Ultra Elite-PF operating manual

WatchGas NEO user manual

WatchGas

WatchGas NEO user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.