Keysight Technologies 11852B Manual

The test & measurement
equipment you need at
the price you want.
Alltest carries the world’s largest selection of
used/refurbished benchtop test & measurement
equipment at 50% the price of new.
O
Our equipment is guaranteed working, warrantied, and
available with certified calibration from our in-house staff
of technicians and engineers.
• 10+ full time technicians with over 150 years of
specialization
• 90 day warranty & 5 day right of return on all
equipment
•
• 1-3 year warranties for new and
premium-refurbished equipment
• Every unit tested to OEM specifications
• Satisfaction guaranteed
You have plans, we will help you achieve them.
Any project. Any budget.
Get a quote today!
CCall (732) 919-3339 or email sales@alltest.net.
t
Alltest Instruments, Inc.
500 Central Ave.
Farmingdale, NJ 07727
P: (732) 919-3339
F: (732) 919-3332
alltest.net
s
sales@alltest.net

Keysight 11852B
Minimum Loss Pad
User’s and
Service Guide

2 Keysight 11852B User’s and Service Guide
Notices
Copyright Notice
© Keysight Technologies 2014 - 2019
No part of this manual may be reproduced in
any form or by any means (including electronic
storage and retrieval or translation into a for-
eign language) without prior agreement and
written consent from Keysight Technologies as
governed by United States and international
copyright laws.
Manual Part Number
11852-90009
Edition
Edition 2, January 29, 2019
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies
Bayan Lepas Free Industrial Zone,
11900 Penang, Malaysia
Technology Licenses
The hardware and/or software described in
this document are furnished under a license
and may be used or copied only in accordance
with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this product
and for other Keysight products may be down-
loaded from the Web. Go to http://www.key-
sight.com/go/conformity. You can then search
by product number to find the latest Declara-
tion of Conformity.
U.S. Government Rights
The Software is “commercial computer soft-
ware,” as defined by Federal Acquisition Regu-
lation (“FAR”) 2.101. Pursuant to FAR 12.212
and 27.405-3 and Department of Defense FAR
Supplement (“DFARS”) 227.7202, the U.S.
government acquires commercial computer
software under the same terms by which the
software is customarily provided to the public.
Accordingly, Keysight provides the Software to
U.S. government customers under its standard
commercial license, which is embodied in its
End User License Agreement (EULA), a copy of
which can be found at http://www.key-
sight.com/find/sweula. The license set forth in
the EULA represents the exclusive authority by
which the U.S. government may use, modify,
distribute, or disclose the Software. The EULA
and the license set forth therein, does not
require or permit, among other things, that
Keysight: (1) Furnish technical information
related to commercial computer software or
commercial computer software documenta-
tion that is not customarily provided to the
public; or (2) Relinquish to, or otherwise pro-
vide, the government rights in excess of these
rights customarily provided to the public to
use, modify, reproduce, release, perform, dis-
play, or disclose commercial computer soft-
ware or commercial computer software
documentation. No additional government
requirements beyond those set forth in the
EULA shall apply, except to the extent that
those terms, rights, or licenses are explicitly
required from all providers of commercial
computer software pursuant to the FAR and
the DFARS and are set forth specifically in
writing elsewhere in the EULA. Keysight shall
be under no obligation to update, revise or
otherwise modify the Software. With respect
to any technical data as defined by FAR 2.101,
pursuant to FAR 12.211 and 27.404.2 and
DFARS 227.7102, the U.S. government
acquires no greater than Limited Rights as
defined in FAR 27.401 or DFAR 227.7103-5 (c),
as applicable in any technical data.
Warranty
THE MATERIAL CONTAINED IN THIS DOCU-
MENT IS PROVIDED “AS IS,” AND IS SUBJECT
TO BEING CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO THE MAXI-
MUM EXTENT PERMITTED BY APPLICABLE
LAW, KEYSIGHT DISCLAIMS ALL WARRAN-
TIES, EITHER EXPRESS OR IMPLIED, WITH
REGARD TO THIS MANUAL AND ANY INFOR-
MATION CONTAINED HEREIN, INCLUDING
BUT NOT LIMITED TO THE IMPLIED WARRAN-
TIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS OR FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES
IN CONNECTION WITH THE FURNISHING,
USE, OR PERFORMANCE OF THIS DOCU-
MENT OR OF ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND THE USER
HAVE A SEPARATE WRITTEN AGREEMENT
WITH WARRANTY TERMS COVERING THE
MATERIAL IN THIS DOCUMENT THAT CON-
FLICT WITH THESE TERMS, THE WARRANTY
TERMS IN THE SEPARATE AGREEMENT
SHALL CONTROL.
Safety Information
CAUTION
A CAUTION notice denotes a hazard. It calls
attention to an operating procedure, practice,
or the like that, if not correctly performed or
adhered to, could result in damage to the
product or loss of important data. Do not pro-
ceed beyond a CAUTION notice until the indi-
cated conditions are fully understood and met.
WARNING
A WARNING notice denotes a hazard. It calls
attention to an operating procedure, practice,
or the like that, if not correctly performed or
adhered to, could result in personal injury or
death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully
understood and met.

Keysight 11852B User’s and Service Guide 3
Safety Symbols
The following symbols on the instrument and in the documentation indicate precautions which
must be taken to maintain safe operation of the instrument.
Regulatory Markings
When you see this symbol on your instrument,
you should refer to the instrument’s
instruction manual for important information.
This symbol indicates hazardous voltages.
The laser radiation symbol is marked on products
that have a laser output.
This symbol indicates that the instrument
requires alternating current (ac) input.
This symbol indicates that the power line switch
is ON.
This symbol indicates that the power line switch
is OFF or in STANDBY position.
The CE mark is a registered trademark of the
European Community. This CE mark shows that
the product complies with all the relevant
European Legal Directives.
The CSA mark is a registered trademark of the
Canadian Standards Association.
This text indicates that the instrument is an
Industrial Scientific and Medical Group 1 Class A
product (CISPER 11, Clause 4).

4 Keysight 11852B User’s and Service Guide
Waste Electrical and Electronic Equipment (WEEE) Directive
This instrument complies with the WEEE Directive marking requirement. This affixed product label
indicates that you must not discard this electrical or electronic product in domestic household
waste.
Product category:
With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified
as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://
about.keysight.com/en/companyinfo/environment/takeback.shtml for more information.
Sales and Technical Support
To contact Keysight for sales and technical support, refer to the support links on the following
Keysight websites:
–www.keysight.com/find/adapters
(product-specific information and support, software and documentation updates)
–www.keysight.com/find/assist
(worldwide contact information for repair and service)

Keysight 11852B User’s and Service Guide 5
Table of Contents
Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Regulatory Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Waste Electrical and Electronic Equipment (WEEE) Directive . . . . . . . . . . . . . . . . . . . . 4
Product category: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Sales and Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Operating Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

6 Keysight 11852B User’s and Service Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Keysight 11852B User’s and Service Guide 7
List of Figures
Figure 1 11852B minimum loss pad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

8 Keysight 11852B User’s and Service Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Keysight 11852B User’s and Service Guide 9
List of Tables
Table 1 Operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 2 Physical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

10 Keysight 11852B User’s and Service Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Keysight 11852B User’s and Service Guide 11
General Information
To obtain optimum performance from this minimum loss pad, observe these simple precautions.
– Make connections carefully to avoid misalignment and connector damage or inaccurate
measurements.
– Keep the connectors free of dirt and metallic particles.
– For information on connector cleaning and care, refer to Keysight Technologies' Microwave
Connector Care Manual.
Figure 1 11852B minimum loss pad
Description
The 11852B minimum loss pad is a 50Wto 75Wor 75Wto 50Wimpedance converter with type-N
connectors. The standard 11852B has a female 50W and a male 75W connector. The 11852B
Option 004 has a male 50W and a female 75W connector. Figure 1 is a representation of a standard
11852B.
CAUTION
Mating a 50Wmale connector with a 75Wfemale connector will destroy the 75Wconnector.

12 Keysight 11852B User’s and Service Guide
Operating Characteristics
Physical Characteristics
Table 1 Operating characteristics
Characteristic Description
Frequency range dc to 3.0 GHz
Nominal insertion loss 5.7 dB
Return loss 75Wside (50Wside terminated) ¡ 32dB, dc to 2 GHz
¡ 27dB, 2 GHz to 3 GHz
Return loss 50Wside (75Wside terminated) ¡ 32dB, dc to 2 GHz
¡ 27dB, 2 GHz to 3 GHz
Maximum input power 250 mW (+24 dBm)
Table 2 Physical characteristics
Characteristic Description
Standard connectors 50Wtype-N (f), 75Wtype-N (m)
Option 004 connectors 75Wtype-N (f), 50Wtype-N (m)
Net weight 0.11 kg (4 oz)
Shipping weight 0.26 kg (9 oz)
Diameter 14 mm (0.6 in)
Length 70 mm (2.8 in)
Female center conductor protrusion 0.204 to 0.207 inch
Male center conductor protrusion 0.208 to 0.211 inch

This information is subject to change
without notice. Always refer to the
Keysight website for the latest
revision.
© Keysight Technologies 2014 - 2019
Edition 2, January 29, 2019
Printed in Malaysia
*11852-90009*
11852-90009
www.keysight.com
Table of contents
Other Keysight Technologies Adapter manuals

Keysight Technologies
Keysight Technologies UXG X Series User manual

Keysight Technologies
Keysight Technologies 11904S Manual

Keysight Technologies
Keysight Technologies 11854A Service manual

Keysight Technologies
Keysight Technologies N1022B User manual

Keysight Technologies
Keysight Technologies E2613A User manual

Keysight Technologies
Keysight Technologies 11920A Manual

Keysight Technologies
Keysight Technologies 16065C Operation manual

Keysight Technologies
Keysight Technologies 16200B Operation manual

Keysight Technologies
Keysight Technologies V281C Service manual

Keysight Technologies
Keysight Technologies 86211A Service manual