Keysight Technologies 11904S Manual

Keysight 11904S
2.4 mm/2.92 mm Adapter Set
User’s and
Service Guide

2 Keysight 11904S User’s and Service Guide
Notices
Copyright Notice
© Keysight Technologies 2012 - 2019
No part of this manual may be reproduced in
any form or by any means (including electronic
storage and retrieval or translation into a for-
eign language) without prior agreement and
written consent from Keysight Technologies as
governed by United States and international
copyright laws.
Manual Part Number
11904-90009
Edition
Edition 6, February 20, 2019
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies
Bayan Lepas Free Industrial Zone,
11900 Penang, Malaysia
Technology Licenses
The hardware and/or software described in
this document are furnished under a license
and may be used or copied only in accordance
with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this product
and for other Keysight products may be down-
loaded from the Web. Go to http://www.key-
sight.com/go/conformity. You can then search
by product number to find the latest Declara-
tion of Conformity.
U.S. Government Rights
The Software is “commercial computer soft-
ware,” as defined by Federal Acquisition Regu-
lation (“FAR”) 2.101. Pursuant to FAR 12.212
and 27.405-3 and Department of Defense FAR
Supplement (“DFARS”) 227.7202, the U.S.
government acquires commercial computer
software under the same terms by which the
software is customarily provided to the public.
Accordingly, Keysight provides the Software to
U.S. government customers under its standard
commercial license, which is embodied in its
End User License Agreement (EULA), a copy of
which can be found at http://www.key-
sight.com/find/sweula. The license set forth in
the EULA represents the exclusive authority by
which the U.S. government may use, modify,
distribute, or disclose the Software. The EULA
and the license set forth therein, does not
require or permit, among other things, that
Keysight: (1) Furnish technical information
related to commercial computer software or
commercial computer software documenta-
tion that is not customarily provided to the
public; or (2) Relinquish to, or otherwise pro-
vide, the government rights in excess of these
rights customarily provided to the public to
use, modify, reproduce, release, perform, dis-
play, or disclose commercial computer soft-
ware or commercial computer software
documentation. No additional government
requirements beyond those set forth in the
EULA shall apply, except to the extent that
those terms, rights, or licenses are explicitly
required from all providers of commercial com-
puter software pursuant to the FAR and the
DFARS and are set forth specifically in writing
elsewhere in the EULA. Keysight shall be
under no obligation to update, revise or other-
wise modify the Software. With respect to any
technical data as defined by FAR 2.101, pursu-
ant to FAR 12.211 and 27.404.2 and DFARS
227.7102, the U.S. government acquires no
greater than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as applicable
in any technical data.
Warranty
THE MATERIAL CONTAINED IN THIS DOCU-
MENT IS PROVIDED “AS IS,” AND IS SUBJECT
TO BEING CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO THE MAXI-
MUM EXTENT PERMITTED BY APPLICABLE
LAW, KEYSIGHT DISCLAIMS ALL WARRAN-
TIES, EITHER EXPRESS OR IMPLIED, WITH
REGARD TO THIS MANUAL AND ANY INFOR-
MATION CONTAINED HEREIN, INCLUDING
BUT NOT LIMITED TO THE IMPLIED WARRAN-
TIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS OR FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES
IN CONNECTION WITH THE FURNISHING,
USE, OR PERFORMANCE OF THIS DOCU-
MENT OR OF ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND THE USER
HAVE A SEPARATE WRITTEN AGREEMENT
WITH WARRANTY TERMS COVERING THE
MATERIAL IN THIS DOCUMENT THAT CON-
FLICT WITH THESE TERMS, THE WARRANTY
TERMS IN THE SEPARATE AGREEMENT
SHALL CONTROL.
Safety Information
CAUTION
A CAUTION notice denotes a hazard. It calls
attention to an operating procedure, practice,
or the like that, if not correctly performed or
adhered to, could result in damage to the
product or loss of important data. Do not pro-
ceed beyond a CAUTION notice until the indi-
cated conditions are fully understood and met.
WARNING
A WARNING notice denotes a hazard. It calls
attention to an operating procedure, practice,
or the like that, if not correctly performed or
adhered to, could result in personal injury or
death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully
understood and met.

Keysight 11904S User’s and Service Guide 3
Certification
Keysight Technologies certifies that this product met its published specifications at the time of
shipment from the factory. Keysight Technologies further certifies that its calibration
measurements are traceable to the United States National Institute of Standards and Technology
(NIST, formerly NBS), to the extend allowed by the Institute’s calibration facility, and to the
calibration facilities of the other International Standards Organization members.
Regulatory Markings
The CE mark is a registered trademark
of the European Community. This CE
mark shows that the product complies
with all the relevant European Legal
Directives.
The CSA mark is a registered
trademark of the Canadian
Standards Association.
ICES/NMB-001 indicates that this ISM
device complies with the Canadian
ICES-001.
Cet appareil ISM est conforme a la
norme NMB-001 du Canada.
This text indicates that the instrument
is an Industrial Scientific and Medical
Group 1 Class A product (CISPER 11,
Clause 4).
This symbol indicates the time period
during which no hazardous or toxic
substance elements are expected to
leak or deteriorate during normal use.
Forty years is the expected useful life
of the product.

4 Keysight 11904S User’s and Service Guide
Waste Electrical and Electronic Equipment (WEEE) Directive
This instrument complies with the WEEE Directive marking requirement. This affixed product label
indicates that you must not discard this electrical or electronic product in domestic household
waste.
Product category:
With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified
as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://
about.keysight.com/en/companyinfo/environment/takeback.shtml for more information.
Sales and Technical Support
To contact Keysight for sales and technical support, refer to the support links on the following
Keysight websites:
–www.keysight.com/find/adapters
(product-specific information and support, software and documentation updates)
–www.keysight.com/find/assist
(worldwide contact information for repair and service)

Keysight 11904S User’s and Service Guide 5
Table of Contents
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Regulatory Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Waste Electrical and Electronic Equipment (WEEE) Directive . . . . . . . . . . . . . . . . . . . . 4
Product category: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Sales and Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 General Information
Adapter Set Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Adapter set contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Calibration definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Adapters (2.4 mm and 2.92 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Connector adapter sets documented in this manual . . . . . . . . . . . . . . . . . . . . . . . . 12
Equipment required but not supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Incoming Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Clarifying the Sex of Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2 Specifications
Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Temperature — what to watch out for . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Mechanical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Pin depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Residual errors after calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3 Use, Maintenance, and Care of the Devices
Electrostatic Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Visual Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Look for obvious defects and damage first . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
What causes connector wear? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Inspect the mating plane surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Slotted connectors (2.92 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Precision slotless connectors (2.4 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Calibration Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Full two-port calibration overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Two-port calibration procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Cleaning the Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

6 Keysight 11904S User’s and Service Guide
Gaging Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Connector gage accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
When to gage connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Gaging Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Gaging 2.4 mm and 2.92 mm connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
How to make a connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Final connection using a torque wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
How to separate a connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Operational Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Connect the 2.4 mm lowband load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Handling and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4 Performance Verification
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
How Keysight Verifies the Devices in Your Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Recertification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
How often to recertify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Where to send a kit for recertification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
5 Troubleshooting
Troubleshooting Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Returning a Kit or Device to Keysight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Where to look for more information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
How Keysight Verifies the Devices in Your Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Recertification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
How often to recertify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Where to send a kit for recertification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Keysight 11904S User’s and Service Guide 7
List of Figures
Figure 2-1 Connector pin depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 3-1 ESD protection setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 3-2 Full two-port calibration - Keysight 8510 VNA using calibration kit defini-
tion CK_292MMA3 and higher . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 3-3 Gaging 2.4 mm and 2.92 mm connectors . . . . . . . . . . . . . . . . . . . . . . 35
Figure 3-4 Wrench positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 3-5 Using the torque wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 3-6 2.4 mm to 2.92 mm adapter to lowband load . . . . . . . . . . . . . . . . . . . 39
Figure 3-7 2.4 mm to 2.92 mm adapter to sliding load . . . . . . . . . . . . . . . . . . . . 41
Figure 5-1 Troubleshooting flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

8 Keysight 11904S User’s and Service Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Keysight 11904S User’s and Service Guide 9
List of Tables
Table 1-1 Clarifying the sex of connectors: examples . . . . . . . . . . . . . . . . . . . . . 14
Table 2-1 Environmental specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 2-2 Pin depth limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 2-3 Electrical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 3-1 Torque wrench information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

10 Keysight 11904S User’s and Service Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

1 General Information
12 Keysight 11904S User’s and Service Guide
Adapter Set Overview
The Keysight 11904S adapter set is designed to give network analyzer systems with 2.4 mm test
ports (such as the Keysight 8510, 8722, and the PNA Series) the ability to perform measurements
on devices with 2.92 mm connectors. The set can be used to achieve calibrated measurements of
2.92 mm devices up to 40 GHz, and 2.4 mm devices up to 50 GHz.
Adapter set contents
The basic 11904S adapter set includes the following items:
– User’s and Service Guide (x 1)
– 2.4 mm to 2.92 mm adapters (x 4)
– 5/16 in, 56 N-cm (5 in-lb) torque wrench for use on the 2.92 mm connectors (x 1)
– Open-end wrench for the 7 mm flats on some of the components (x 1)
Calibration definitions
The calibration definitions are for you to use with your analyzer. Refer to your network analyzer
User’s Guide, or embedded Help for information on modifying the calibration kit standard
definitions.
8510
– 2.92 mm A.3, contains modified standards data to account for the adapters, which are inserted
after a 2.4 mm calibration is performed.
– 2.4 mm A.4, contains calibration definitions for only the 2.4 mm devices.
Adapters (2.4 mm and 2.92 mm)
Like the other devices in the kit, the adapters are built to very tight tolerances to provide good
broadband performance and to ensure stable, repeatable connections.
The adapters are designed so that their nominal electrical lengths are the same, which allows them
to be used in calibration procedures for non-insertable devices (such as adapter removal).
The male 2.4 mm and 2.92 mm connectors are metrology grade. The female PSC-2.4 mm is a
metrology–grade, precision slotless connector. The female 2.92 mm connectors have slotted
contacts and therefore cannot be considered metrology grade. Due to the extremely thin wall of
the 2.92 mm female connector, a slotless metrology grade 2.92 mm connector pair does not
currently exist.
Connector adapter sets documented in this manual
The part numbers provided in this manual are the recommended replacement parts for this set. The
devices in this set should meet the specifications published in this manual.
Equipment required but not supplied
Some items are required or recommended for successful operation of your kit, but are not supplied
with the kit.

General Information 1
Keysight 11904S User’s and Service Guide 13
Incoming Inspection
To verify the electrical performance of the devices in this set, see Chapter 4, "Performance
Verification".
Check for damage. The foam-lined storage case provides protection during shipping. If the case or
any device appears damaged, or if the shipment is incomplete, refer to the Keysight contact
numbers located at the end of this manual. Keysight will arrange for repair or replacement of
incomplete or damaged shipments without waiting for a settlement from the transportation
company. See “Returning a Kit or Device to Keysight” on page 49.

1 General Information
14 Keysight 11904S User’s and Service Guide
Clarifying the Sex of Connectors
In this document and in the prompts of the PNA calibration wizard, the sex of cable connectors and
adapters is referred to in terms of the center conductor. For example, a connector or device
designated as 1.85 mm –f– has a 1.85 mm female center conductor.
8510-Series, 872x, and 875x ONLY: In contrast, during a measurement calibration, the network
analyzer softkey menus label a 1.85 mm calibration device with reference to the sex of the
analyzer’s test port connector—not the calibration device connector. For example, the label
SHORT(F) refers to the short that is to be connected to the female test port. This will be a male
short from the calibration kit.
A connector gage is referred to in terms of the connector that it measures. For instance, a male
connector gage has a female connector on the gage so that it can measure male devices.
Table 1-1 Clarifying the sex of connectors: examples
Terminology Meaning
Short –f– Female short (female center conductor)
Short (f) Male short (male center conductor) to be connected to female port

General Information 1
Keysight 11904S User’s and Service Guide 15
Preventive Maintenance
The best techniques for maintaining the integrity of the devices in the kit include:
– routine visual inspection
– routine cleaning
– proper gaging
– proper connection techniques
All of these are described in Chapter 3, "Use, Maintenance, and Care of the Devices". Failure to
detect and remove dirt or metallic particles on a mating plane surface can degrade repeatability
and accuracy and can damage any connector mated to it. Improper connections, resulting from pin
depth values being out of the observed limits (see Table 2-2 on page 20) or from bad connection
techniques, can also damage these devices.

1 General Information
16 Keysight 11904S User’s and Service Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Keysight 11904S 2.4 mm/2.92 mm Adapter Set
User’s and Service Guide
17
2 Specifications
Environmental Requirements 18
Mechanical Characteristics 19
Electrical Specifications 21
This chapter provides the environmental requirements, mechanical characteristics, and electrical
specifications of the 11904S adapter set.

2 Specifications
18 Keysight 11904S User’s and Service Guide
Environmental Requirements
The Keysight 8497K Attenuator is designed to fully comply with Keysight Technologies’ product
operating environmental specifications as shown in Table 2-1.
Temperature — what to watch out for
Changes in temperature can affect electrical characteristics. Therefore, the operating temperature
is a critical factor in performance. During a measurement calibration, the temperature of the
calibration devices must be stable and within the range shown in Table 2-1.
Table 2-1 Environmental specifications
Parameter Limits
Temperature
–Operating
[a]
–Storage
– Error-corrected range[b]
[a] The temperature range over which the calibration standards maintain conformance to their specifications.
[b] The allowable network analyzer ambient temperature drift during measurement calibration and during measurements when the network
analyzer error correction is turned on. Also, the range over which the network analyzer maintains its specified performance while correction
is turned on.
– +20 °C to +26 °C
– –40 °C to +75 °C
– ± 1 °C of measurement calibration temperature
Altitude
–Operating
–Storage
– < 4,500 meters (_15,000 feet)
– < 15,000 meters (_50,000 feet)
Relative humidity
–Operating
–Storage
Always non-condensing
– 0 to 80% (26 °C maximum dry bulb)
– 0 to 90%
CAUTION
Avoid unnecessary handling of the devices during calibration because your fingers act as a heat
source and may increase the temperature of the device.

Specifications 2
Keysight 11904S User’s and Service Guide 19
Mechanical Characteristics
Mechanical characteristics such as center conductor protrusion and pin depth are not performance
specifications. They are, however, important supplemental characteristics related to electrical
performance. Keysight Technologies verifies the mechanical characteristics of the devices in the kit
with special gaging processes and electrical testing.
This ensures that the device connectors do not exhibit any center conductor protrusion or improper
pin depth when the kit leaves the factory.
“Gaging Connectors” on page 32 explains how to use gages to determine if the kit devices have
maintained their mechanical integrity. Refer to Table 2-2 for typical and observed pin depth limits.
Pin depth
Pin depth is the distance the center conductor mating plane differs from being flush with the outer
conductor mating plane. See Figure 2-1. The pin depth of a connector can be in one of two states:
either protruding or recessed.
Protrusion is the condition in which the center conductor extends beyond the outer conductor
mating plane. This condition will indicate a positive value on the connector gage.
Recession is the condition in which the center conductor is set back from the outer conductor
mating plane. This condition will indicate a negative value on the connector gage.
Figure 2-1 Connector pin depth
The pin depth value of each calibration device in the kit is not specified, but is an important
mechanical parameter. The electrical performance of the device depends, to some extent, on its
pin depth. The electrical specifications for each device in the kit take into account the effect of pin
depth on the device’s performance. Table 2-2 lists the typical pin depths and measurement
uncertainties, and provides observed pin depth limits for the devices in the kit. If the pin depth of a
device does not measure within the observed pin depth limits, it may be an indication that the
device fails to meet electrical specifications. Refer to Figure 2-1 for a visual representation of
proper pin depth (slightly recessed).

2 Specifications
20 Keysight 11904S User’s and Service Guide
When measuring pin depth, the measured value (resultant average of three or more
measurements) is not the true value. Always compare the measured value with the observed pin
depth limits in Table 2-2 to evaluate the condition of device connectors.
Table 2-2 Pin depth limits
Device Typical pin depth Measurement uncertainty[a]
[a] Approximately +2 sigma to -2 sigma of gage uncertainty based on studies done at the factory according to recommended procedures.
Observed pin depth limits[b]
[b] Observed pin depth limits are the range of observation limits seen on the gage reading due to measurement uncertainty. The depth could
still be within specifications.
Opens 0 to –0.0127 mm
0 to –0.00050 in
+0.0030 to –0.0030 mm
+0.00012 to –0.00012 in
+0.0030 to –0.0157 mm
+0.00012 to –0.00062 in
Shorts 0 to –0.0127 mm
0 to –0.00050 in
+0.0015 to –0.0015 mm
+0.00006 to –0.00006 in
+0.0015 to –0.0142 mm
+0.00006 to –0.00056 in
Fixed loads –0.0025 to –0.0203 mm
–0.0001 to –0.00080 in
+0.0030 to –0.0030 mm
+0.00012 to –0.00012 in
+0.00050 to –0.0234 mm
+0.00002 to –0.00092 in
Adapters (2,4 to 2.4) –0 to –0.0381 mm
–0 to –0.00150 in
+0.0030 to –0.0030 mm
+0.00012 to–0.00012 in
+0.0030 to –0.0411 mm
+0.00012 to –0.00162 in
Adapters (2.4 to 2.92)[c]
[c] 2.4 mm to 2.92 mm adapters require a 3.5 mm connector gage to measure the 2.92 mm end.
0 to –0.0381 mm
0 to –0.00150 in
+0.0030 to –0.0030 mm
+0.00012 to–0.00012 in
+0.0030 to –0.0411 mm
+0.00012 to –0.00162 in
Sliding loads 0 to –0.0127 mm
0 to –0.00050 in
+0.0015 to –0.0015 mm
+0.00006 to –0.00006 in
+0.0015 to –0.0142 mm
+0.00006 to –0.00056 in
Table of contents
Other Keysight Technologies Adapter manuals

Keysight Technologies
Keysight Technologies E2613A User manual

Keysight Technologies
Keysight Technologies 87300B User guide

Keysight Technologies
Keysight Technologies 11920A Manual

Keysight Technologies
Keysight Technologies V281C Service manual

Keysight Technologies
Keysight Technologies 11852B Manual

Keysight Technologies
Keysight Technologies 11854A Service manual

Keysight Technologies
Keysight Technologies 86211A Service manual

Keysight Technologies
Keysight Technologies 16065C Operation manual

Keysight Technologies
Keysight Technologies 16200B Operation manual

Keysight Technologies
Keysight Technologies UXG X Series User manual