SPECIFICATIONS &
ELECTRICAL INFOR ATION
SPECIFICATIONS
odel ............................................................................................................................................................................................KC-10020SQ
Voltage ......................................................................................................................................................................................................120V
Horsepower......................................................................................................................................................................................3 Peak HP
Amperage....................................................................................................................................................................................................14A
RP (no load speed) ..............................................................................................................................................................................1,680
Phase ..............................................................................................................................................................................................................1
Hertz ..........................................................................................................................................................................................................60Hz
Operating pressure..............................................................................................................................................................................125 PSI
CF @ 40 PSI ..............................................................................................................................................................................................5.6
CF @ 90 PSI ..............................................................................................................................................................................................4.4
Tank size ............................................................................................................................................................................................10 Gallon
ELECTRICAL INFOR ATION
WARNING
A E ECTRICA CONNECTIONS MUST BE DONE BY A QUA IFIED E ECTRICIAN. FAI URE TO COMP Y MAY RESU T IN
SERIOUS INJURY! A ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE COMPRESSOR DISCONNECTED FROM THE
POWER SOURCE. FAI URE TO COMP Y MAY RESU T IN SERIOUS INJURY!
GENERAL INFOR ATION- 120V single phase operation
This air compressor comes with a 120V single phase motor wired for 110V-
120V operation.
WARNING: YOUR COMPRESSOR MUST BE CONNECTED TO A 120V,
WITHAMINIMUM 15-AMP. BRANCH CIRCUIT. FAI URE TO CONNECT
IN THIS WAY CAN RESU T IN INJURY FROM SHOCK OR FIRE.
GROUNDING
Your compressor must be properly grounded. Not all outlets are properly
grounded. If you are not sure if your outlet is properly grounded, have it
checked by a qualified electrician.
WARNING: IF NOT PROPER Y GROUNDED, THIS COMPRESSOR
CAN CAUSE E ECTRICA SHOCK, PARTICU AR Y WHEN USED IN
DAMP OCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD
IS WORN OR DAMAGED IN ANY WAY, HAVE IT REP ACED
IMMEDIATE Y.
If this compressor should malfunction or breakdown, grounding provides a
path of least resistance for electric current, to reduce the risk of electric
shock. This cut-off is equipped with a cord having an equipment-grounding
conductor and grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING: TO MAINTAIN PROPER GROUNDING, DO NOT REMOVE OR
A TER THE GROUNDING PRONG IN ANY MANNER.
120V OPERATION
As received from the factory, your compressor is ready to run for 120V
operation. This machine is intended for use on a electrical circuit that has
an outlet and a plug which looks like the one illustrated in Fig.1.
WARNING: DO NOT USE A TWO-PRONG ADAPTOR FOR THEY ARE
NOT IN ACCORDANCE WITH OCA CODES AND ORDINANCES.
NEVER USE IN CANADA.
FIGURE 1
FIGURE 2
EXTENSION CORDS
The use of any extension cord will cause some loss of power. IT
IS RECOMMENDED TO USE A ONGER AIR HOSE INSTEAD
OF AN EXTENSION CORD. If you do not have a choice, use the
chart in Fig.2 to determine the minimum wire size
(A.W.G-American Wire Gauge) extension cord needed. Use only
3-wire extension cords which have 3-prong grounding type plugs
and 3-hole receptacles which accept the tool’s plug.
For circuits that are further away from the electrical circuit box, the
wire size must be increased proportionately in order to deliver
ample voltage to the compressor motor. Refer to Fig.2 for wire
length and size.
PROPERLY GROUNDED OUTLET
CURRENT CARRYING PRONGS
GROUNDING PRONG
Tool’s
Amperage
Rating
3-6
6-8
8-10
10-12
12-16
Cord Size in A.W.G.
Cord Length in Feet
25 50 100 150
18 16 16 14
18 16 14 12
18 16 14 12
18 16 14 12
14 12 - -