King Pigeon S130 User manual

Remote switching machines with a SMS text from your mobile phone!
Remote Monitoring your assets in the worldwide by your mobile Phone!
GSM SMS Controller
GSM SMS Alarm Unit
S130 S140 S150
User Manual
Ver 1.50 Date Issued: 2011-04-06
Table of contents
1. Brief introduction ----------------------------------------------------------------------------3

2. Safety Directions ----------------------------------------------------------------------------3
3. Standard Packing list -----------------------------------------------------------------------4
4. Physical Layout ------------------------------------------------------------------------------4
5. Features ---------------------------------------------------------------------------------------5
6. Settings ----------------------------------------------------------------------------------------6
7. Operation --------------------------------------------------------------------------------------9
8. Installation -----------------------------------------------------------------------------------10
9. Technical specifications ----------------------------------------------------------------17
10. Quality Warranty ---------------------------------------------------------------------------17
11. Trouble Shooting Guide------------------------------------------------------------------17
Model List
Model No.
Differences
S130
2 Digital inputs, 1 Alarm Link output relay, 1 independent output relay for SMS Commands.

S140
4 Digital inputs, 1 Alarm Link output relay, 1 independent output relay for SMS Commands.
S150
8 Digital inputs, 1 Alarm Link output relay, 1 independent output relay for SMS Commands.
Notice: The PC Configurator is free of charge, suitable for S130, S140, S150. For S130, only the input1 and input2 are valid;
For S140, only the input1, input2, input3, input4 are valid. For S150, all inputs are valid.
SMS Command List
SMS COMMAND
Functions & Actions
AA
To arm the system, in this case, any detector triggered will alarm.
BB
To disarm the system, in this case, any detector triggered will not alarm.
CC
To switch ON the independent output relay
DD
To switch OFF the independent output relay
EE
Inquiry the GSM SMS Controller Status
*The commands should plus Password, the format is Password+SMS Command. i.e.: if the password is 1234, then you
can send 1234AA to arm, 1234BB to disarm. The password can be modified by PC Configurator.
1. Brief introduction
The GSM SMS Controller is a very simple device which can be used for authorized door access, controlling
gates, switching of remote equipments, car parking systems. Actually the GSM SMS Controller can be used in
places which require turning ON/OFF your system, machines, and equipments remotely with a SMS text from
your mobile phone and protect your assets.
Moreover, the GSM SMS Controller with multi-digital inputs for digital inputs, when any one of the inputs
triggered, will start the siren or switch on the light automatically. In the meanwhile, the GSM SMS Controller will
send SMSAlert to the owners immediately. This is very useful if you need protect your assets with low cost
solution.
The GSM SMS Controller suitable for below applications:
1. Security Alarm System applications;
2. Supervision and monitoring alarm systems;
3. Automatic monitoring system;
4. Vending Machines security protection;
5. Pumping Stations, Tanks, Oil or Water levels;
6. Buildings and Real Estate;
7. Weather Stations;
8. River Monitoring and Flood Control;
9. Oil and gas pipelines;
10. Corrosion protection
11. Temperatures, water leakage applications;
12. Wellheads, boat, vehicle;
13. Energy saving, street lights control system;
14. Valve controls;
15. Transformer stations;
16. Unmanned machine rooms;
17. Control room application;
18. Automation System, M2M;
19. GSM Access Control System, GSM Gate Opener, etc.

2.Safety Directions
Safe Startup
Do not use GSM SMS Controller when using GSM equipment is prohibited or might bring
disturbance or danger.
Interference
All wireless equipment might interfere network signals of GSM SMS Controller and influence its
performance.
Avoid Use at Gas Station
Do not use GSM SMS Controller at a gas station. Power off GSM SMS Controller when it near
fuels or chemicals.
Power it off near Blasting Places
Please follow relevant restrictive regulations.Avoid using the device in blasting places.
Reasonable Use
Please install the product at suitable places as described in the product documentation.Avoid
signal shielded by covering the mainframe.
Use Qualified Maintenance Service
Maintenance can be carried out only by qualified maintainer.
3. Standard Packing List
Control Unit X1, GSM ANT X1, PC Configurator and User Manual X1(CD), Connectors,AC/DC Adaptor X1.
Optional Accessories: (Wired Detectors)
PIR Motion Detector, Glass Break Detector, Magnetic Window Detector, Temperature Detector, Infrared
Beam Fence, Vibration detector, Water level detector, Siren, etc.
4. Physical Layout
4.1 Control Unit physical layout
LED Instruction
GSM
GSM Module indicator, registering will quickly flick, registered successful will slowly flick.
RELAY
Output relay indicator, when any output relay closed, it will be on; when relay opened, it will be off.
STATUS
Arm Indicator, on is armed, off is disarmed;
Alarm
Alarm Indicator, on is alarming, off is normally;

Interface 1 Instruction
MIC
For listening in the sounds around the GSM SMS Controllers while alarm, the Microphone is
needn’t power, it is the same type for the computer.
SPK
For two way voice communication. When the authorized numbers dial in, the unit will check the
incoming number, if matched, then can create two-way voice communication.
GSM ANT
Connect the GSMANT, if the GSM signal is not strong; please change the 3dB GSMANT.
USB
Connect to the computer, for setup the unit parameters.
Interface 2 Instruction
POWER
External Power Connector, Connect to 2A@12V DC power through AC/DC Adaptor.
SIREN
Will start for 60seconds when alarm. The siren or strobe siren should be <12V DC.
+12V
+12VDC@1A power output for wired detectors.
IN1
Digital input 1, connect to one wire of the wired Detector.
GND
Ground point; connect to another wire of the wired Detector or -12VDC.
IN2
Digital input 2, connect to one wire of the wired Detector.
IN3
Digital input 3, connect to one wire of the wired Detector.
GND
Ground point; connect to another wire of the wired Detector.
IN4
Digital input 4, connect to one wire of the wired Detector.
+12V
+12VDC@1A power output for wired detectors.
IN5
Digital input 5, connect to one wire of the wired Detector.
GND
Ground point; connect to another wire of the wired Detector or -12VDC.
IN6
Digital input 6, connect to one wire of the wired Detector.
IN7
Digital input7, connect to another wire of the wired Detector.
GND
Ground point; connect to another wire of the wired Detector.
IN8
Digital input 8, connect to one wire of the wired Detector.
R1+
Alarm-Link Output Relay. Built in 240VAC@3Arated relay output, connect to the device positive

electrode. Alarm-Link Output Relay.
R1-
Alarm-Link Output Relay. Built in 240VAC@3Arated relay output, connect to the device negative
electrode.Alarm-Link Output Relay.
R2+
Independent Output Relay. Built in 240VAC@3A rated relay output, connect to the device
positive electrode.
R2-
Independent Output Relay. Built in 240VAC@3Arated relay output, connect to the device
negative electrode.
5. Features
1. 1 Independent Output Relay (240VAC@3A) can be switched ON/OFF by sending a SMS text;
2. 1 Alarm-Link Output Relay (240VAC@3A) can be switch on 0-120minutes if controller unit triggered;
3. 2/4/8Alarm logic digital inputs, NC or NO and EOL is optional;
4. 3 SMSAlert numbers and 5 Alarm dial Telephone numbers can accept to the alarm message;
5. Two-way voice communication by external microphone and speaker;
6. Supports armed, disarmed, inquiry status, switch on or off Independent Output Relay by SMS Commands;
7. Password protected, prevents unauthorized user;
8. Can be set up and programmed from PC Configurator by USB cable;
9. Time stamped alarm messages.
10. Backup rechargeable battery inside, can work for 24hours whenAC Power goes off.
11. Can be operated from anywhere, no distance limit;
12. Based on GSM Network, applied to many applications.
6. Settings
The GSM SMS Controller is for user-friendly design. The user can setup it by the PC Configurator through
USB cable. The GSM SMS Controller can not be configured parameters by SMS Commands.
Tips!
1) In order to forbidden the intruders switch off the unit, we equipped the power switch inside, it is nearby the SIMCard socket,
please pay attention to it, and don’t tell others of this. Turn it towards inside is off, turn it towards outside is on. And when setup
the unit, please put the Setting switch to SET position, after setup, switch it to WORK Position. Please see below photo.

2) Please insert the SIMCard firstly, and install the GSMAntenna, please power on to check the LEDs can work or not, then
switch off it before you program it by PC Configurator.
3) The default password is 1234, you can modify it by enter the new password in the PC Configurator.
4) Two way communication: While the authorized users incoming call, the GSM SMS Controller unit will automatically answer the
call, then the two-way voice communication will be created. If you want to test the two way voice communication, please make
sure the other phone is away from the GSM SMS Controller unit at least 500meters. Otherwise, the near-cross will make lots
of noise interference.
5) When the present alarming hasn’t finished, the GSM SMS Controller will not handle the next alarm event till the present
alarming finished. If the present alarming had finished, and the next alarm event still in alarming condition, the GSM SMS
Controller will handle it.
6) When AC Power goes off, the Relay will not work. And the 12VDC power source for the detectors in the Board will be invalid.
The PC Configurator Interface

Please following the below steps one by one to setup it, otherwise you can not setup it successfully.
Step1: Please Contact the unit to the PC, and then install the USB Driver to the computer from the CD firstly.
When successful, it can be found out at the device manager of the XP or Windows 7, please see the
below photo.And remember the COM port.Also, the driver can be downloaded from Silicon Laboratories,
Inc., the model is CP210x.
If the Com port is not Com1~Com5, then please right click the Device, then enter the Properties to
change it, see below photos, after you changed it, and please restart the computer.

Step2: Please insert the SIMCard into the GSM SMS Controller carefully;
Step3: Please running the PC Configurator, needn’t installed it;
Step4: Please connect the GSM SMS Controller to the computer through USB cable, but please don’t switch
on the GSM SMS Controller, otherwise, the setup will be failure;

Step5: Please setup the GSM SMS Controller parameters, the details please see below Function Table 1;
Step6: After you finished the setup, then press “Save Settings”button then switch on the GSM SMS
controller, after 2Seconds, it will alert the Setup successful. If it hasn’t prompted the setup successful, it
means the setup is failure, please check the Com port and USB connection. You can change the Com
Port to try it one by one, if the Communication LED sign is green after you press the “Save Settings”,
it means the Com port is correct, otherwise, it is incorrect, please use the dropdown menu to change it.
Step 7: Switch off the unit then remove the USB cable, and Switch on the Unit to finish the setup.
If it hasn’t prompted the setup successful, it means the setup is failure, please check the Com port and USB
connection, then try to repeat the Step1~Step6 again.
Function Table 1
Items
Description
Com Setting
Select the Com port to communicate between GSM SMS Controller and Computer.
Save Settings
Save the present settings from computer to GSM SMS Controller.
Read Settings
Read the GSM SMS Controller present settings to computer.
Save Profile
Save the present settings from computer as a file.
Load Profile
Load the settings from the Saved file in the computer.
Stop
Stop the communication between the computer and GSM Controller.
Alarm Dial Tel.
Numbers
Please add the country code, e.g.: +86 or 0086 in China. When alarm, the unit will call
these numbers one by one after sent out SMS Alarm message. Please see below tips.
SMS Alert Numbers
Please add the country code, e.g.:+86 or 0086 in China. When alarm, the unit will send
related Digital Input SMS Alert Content to these numbers one by one firstly.
Input Type
Disable: Means this input is invalid; NC: Normal Close, open will alarm; NO: Normal Open,
close will alarm; EOL: End of Line, Means must be connected with a 2.2K resistor between
the GSM SMS controller and digital detector. See installation diagram.
When Input
Activated SMS Alert
Contents
These words or sentences will be sent to the SMS Alert Numbers once the related inputs
triggered. Max. Characters: 34. If the inputs keep the triggered status, the GSM SMS
Controller will handle it as one alarm case, will stop to send SMS Alarm message till the
inputs recovered and triggered again. This is very useful for the detectors continue keep
the triggered status, like temperature detector, water level detectors, etc.
When Input
Recovered SMS
Alert Contents
These words or sentences will be sent to the SMS Alert Numbers once the related inputs
recovered. Max. Characters: 34.
If you tick the Don’t Care means when this input recovered, will not send SMS to SMS
Alert Numbers. If you like to get SMS alert when the Inputs recovered, then please don’t
tick it, in this condition, the GSM SMS Controller only send SMS to all SMS Alert Numbers,
will not dial the Alarm Dial Tel. Numbers. This is very useful for owners to know when the
inputs recovered, like temperature detector, water level detectors, etc.
Alarm Link Output
Relay
Tick it to setup when this input triggered, the alarm link output relay should close, the
relay close time according to Relay Working Time. Otherwise, the alarm link output relay
will not close.

Sound Alarm
Tick it to setup the siren make sounds for 60 seconds when Alarm occurrence.
GSM Jammer
Tick it to setup when the unit detected no GSM signal for more than 90 seconds, the siren
should sound 60seconds, and alarm-link output relay close 4minutes.(Don’t recommend)
Arm
Tick it to setup the unit to arm mode once power on. In this case, any detector triggered
will alarm. The system will send out the preset SMS text to SMS alert numbers, and dial
the Alarm Dial Tel. Numbers one by one, in the meantime, the siren will sound 60seconds
and the alarm-link output relay will close, the relay close time according to Relay Working
Time. Otherwise, the system will in disarmed mode after power on.
Report Time
Fill it to setup the Report time gap, Range: 0~240Hours. The unit will automatically send
its status to the 1st SMS alert numbers according to this setting. Only in Armed mode is
valid.
Alarm Delay Time
To setup the delay time after any input triggered. The range is 0~90Seconds.
Relay Working Time
To setup the Alarm-Link Output Relay Close time when alarm happened. The range is
0~120Minutes.
Power Down Alert
To setup when AC power goes off, how long to send SMS to the 1st SMS Alert Number.
Don’t Care means when AC Power goes off will not send SMS to the 1st SMS Alert Number.
Immediacy Means will send SMS to the 1st SMS Alert Number immediately. When AC goes
on, the GSM SMS Controller will send SMS to 1st SMS Alert Number.
Password
To verify the SMS commands from the authorized users and modify new password.
Notice:
1. In some GSM operators they use different SMS protocols, if the unit can’t return the SMS confirmation is
normally. It is not product problem. Also, you can try to add the country code before the number, see the
below settings:
7. Operating Instructions
The users can Arm/Disarm/Inquiry system status, Switch on or off the independent output relay by sending
SMS Commands to the Control unit. The SMS Commands are below:
For example:
In China, the country code is +86, or 0086.
The user cell phone number is 13570810254 and has been assigned as a SMS Alert number, the simcard number in the
panel is 13512345678.
Problem 1: Alarm but the user hasn’t received the SMS Alert.
Solution: Please plus the country code while you setup the 13570810254 as SMS Alert number, means setup
+8613570810254 to instead of the 13570810254.
Problem 2: The user number can receive the SMS Alert message from alarm panel, but the alarm panel can not receive
the commands from the user number.
Solution: Please add country code to the SIMCard number in the alarm panel. Means send sms commands to
+8613512345678 to instead of 13512345678.
Solution 3: When you use cell phone dial another one, what number it will be displayed then you can set the displayed
number as dial numbers; when you use cell phone send SMS to another cell phone, what number it will be displayed then
you can set the displayed number as SMS Alert number, just use the “+” to replace the “00”, also, you can try the “00”.

Notice:
The system will carry out the commands immediately (with no delay) after the Control Unit receive this SMS commands.
7.1 Armed
7.2 Disarm
7.3 Switch On the independent output relay
7.4 Switch OFF the independent output relay
7.5 Inquiry System Status
Notice:
The Output relay status in the Return SMS is the independent output relay status. It is not the alarm link Output Relay Status.
xxxxEE
“xxxx”stands for the password (1-4 digits).
Return SMS
Armed or At House or Disarmed
AC Power is Ok or AC Power is failed
GSM Value is 17 or other value
Output Relay is Closed or Output Relay is opened
Example
1111DD
When the Password is 1111
xxxxDD
“xxxx”stands for the password
(1-4 digits).
Return SMS
Output Relay Opened.
Example
1111CC
When the Password is 1111
xxxxCC
“xxxx”stands for the password
(1-4 digits).
Return SMS
Output Relay Closed.
Example
1111BB
When the Password is 1111
xxxxBB
“xxxx”stands for the password
(1-4 digits).
Return SMS
System deactivated.
Example
1234AA
When the Password is 1234
xxxxAA
“xxxx”stands for the password
(1-4 digits).
Return SMS
Armed Mode activated.

8. Installation
Before installing the control unit and detectors and sirens, please help to test the system firstly, including wired
detector, power supply, gsm signal, etc.
8.1 Insert SIMcard into Control Unit
In the backside of the control unit, please install the GSM SIM card . The GSM ANT must be Vertical
installation to ensure it in good working condition.
8.2 Connecting the Wired Detectors and Electricity equipments
Please help to see below wiring diagram, then fixed the related wired detectors; the detectors connect to
the related digital inputs.
Tips!
1) Please setup the Disable(Default), NC, NO, EOL type in the PC Configurator correctly;
2) If you setup the input type as Disable (Default), then the input port will be invalid. We recommend customer setup the no-use
input port as Disable type.
3) If you setup the input type as NC, the detector type must be NC, and if more than one detector contact to one input port,
they’re must be in series connection. Please see below diagram.

4) If you setup the input type as NO, the detector type must be NO, and if more than one detector contact to one input port,
they’re must be in parallel connection. Please see the below diagram.
5) If you setup the input type as EOL, (This type is very useful to monitor the detectors connection condition; intruders cut the
detectors’ wires.)
a) if the detector is NC type, then must be in series connection with a 2.2K Resistor;
b) if more than one NC detector contact to one input port, all detectors are NC type, and must be in series connection with a

2.2K Resistor, the 2.2K Resistor must be placed in the last detector. Please see the below diagram.
c) if the detector is NO type, then must be in parallel connection with a 2.2K Resistor;
d) if more than one NO detector contact to one input port, all detectors are NO type, and must be in parallel connection with
a 2.2K Resistor, the 2.2K Resistor must be placed in the last detector. Please see the below diagram.
6) The Unit built-in 2 240VAC@3A rated relays. Please make sure the power cord rated while you connect to equipment device.
Also, please make sure the power consumption is less than 250W for long time working (Approximate 2Hours ). If you need
heavy equipment, please connect an additional relay ;( Notice: When AC Power goes off, the Relay will not work.)
7) The R1+ and R1- are for alarm-link output relay, when the system alarm, will close, the relay close time according to Relay
Working Time. The rated output power is 700W. If you need heavy equipment, please connect an additional relay.
8) The R2+ and R2- are the output relay for SMS Command, CC is close, DD is open, and EE is inquiry the status.
9) The +12VDC is for the Detectors, if the detectors need 12VDC power, then please contact it to the +12VDC. The 12VDC
power is from external power, not from backup battery. So please note: When AC power failure, the +12VDC point will no
power supply.
8.3 Typical application
One of the typical applications of the GSM SMS Controller is for automatically water tank monitoring and
control solution. Please help to see below diagram. Also it can use to lots of other solutions. E.g.:

1. Security Alarm System applications;
2. Supervision and monitoring alarm systems;
3. Automatic monitoring system;
4. Vending Machines security protection;
5. Pumping Stations, Tanks, Oil or Water levels;
6. Buildings and Real Estate;
7. Weather Stations, River Monitoring and Flood Control;
8. Oil and gas pipelines, Corrosion protection
9. Temperatures, water leakage applications, Wellheads, boat, vehicle;
10. Energy saving, street lights control system, Valve controls;
11. Transformer stations;
12. Unmanned machine rooms, Control room application;
13. Automation System, M2M;
14. GSM Access Control System, GSM Gate Opener, etc.
Application Sample 1
Long Distance Automatically Water/Oil Tank Monitoring and Control Solution
This solution is suitable for the tank far away the Pump Motor, the water level detector can use other
types. Also, the user can use the SMS Command to switch on or switch off the Pump motor when use
the independent output relay. This solution is suitable for lots of other similar monitoring applications.

Explanation:
1) Use the water level detector (WL-04) to detect the water level, it can detect the low level and high level, two wires for low
level, connecting to input 1, two wires for high level, connecting to input 2.
2) Set the SIMCard Number in B side GSM SMS Controller as the first SMS Alarm number in A side GSM SMS Controller,
and modify the SMS Alert content as 1234CC (1234 stands for password) to input 1, 1234DD to input 2. So when Low
level detected, the A side GSM SMS Controller will send 1234CC command to B side GSM SMS Controller to switch ON
the Pump, when high level detected, will send 1234DD to B side GSM SMS Controller to Switch OFF the Pump. Means
the A side alarm SMS message as the B side GSM SMS Controller Command.
Application Sample 2
Local Automatically Water/Oil Tank Monitoring and Control Solution

This solution is suitable for the tank nearby the Pump motor, and the owner know how many minutes
that the pump motor can fill the water to the high level. The water level detector can use other types. Also,
the user can use the SMS Command to switch on or switch off the Pump motor when use the independent
output relay. This solution is suitable for lots of other similar monitoring applications.
Application Sample 3
Environment Condition Monitoring Solution
This solution is suitable for environment condition monitoring, when the temperature or humidity
exceed the pre set value, the air conditioner will switch on. Also, the user can use the SMS Command to
switch on or switch off the air conditioner when use the independent output relay. This solution is suitable
for lots of other similar monitoring applications.

8.3 Install the Mainframe
The mainframe should be installed in the position that person can not get it, and there’re with a power
source as well as enough GSM signal coverage.
8.4 Install the Speak and Microphone to the Mainframe
The GSM SMS Controller allows the authorized users call in to create two way voice communications,
also, when the system alarm, the authorized number can listen in the on-site sounds.

While you install the Microphone and Speaker, please make sure keep it away from the GSM SMS
Controller at least 1meters and far from the siren if possible.
9. Technical specifications
Rated Voltage: 12VDC@ 2A
Working temperature: -10℃~+60℃
Storage temperature: -20℃~+60℃
Relative humidity: 10-90%, No condensation
GSM frequency: 850/900/1800/1900Mhz
Communication protocol: GSM PHASE 2/2+ (include data service)
Digital inputs: 2 / 4 / 8
Backup Rechargeable Battery: 24Hours in standby mode.
Related Voltage of the Output Relay: 3A/240VAC
Net Weight: 0.60Kg
10. Warranty
1) This system is warranted to be free of defects in material and workmanship for one year from the date of
purchase.
2) This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the
Operating Instructions. In no event shall the manufacturer be liable for any alarm system altered by
purchasers.
11.Trouble Shooting Guide
PROBLEM
CAUSE
POSSIBLE SOLUTION
GSM Module
initialization
failed
1) Backup battery with low voltage;
GSM Module connection loose
in transportation;
2) GSM Signal is too weak.
1) Please contact theAC Power;
2) Please help to take the panel to a mobile phone repairmen store, and
then ask the engineer to check the GSM Module socket and the GSM
Module connection;
3) Please change another position to install the alarm panel.
Automatically
Restart
1) Backup battery with low
voltage.
1) Please help to contact theAC Power.
False Alarm
1) PIR Motion detector
installation incorrect;
2) NC/NO/EOL is incorrect.
1) Please see the PIR Motion detector installation user manual carefully;
2) Please check the detector NC/NO type, and you’re sure connect a
2.2K Resistor in series in the un-use input ports.
Alarm without
SMS /Dial/
No action
after send
SMS
1) GSM Operator communication
protocol;
2) Haven’t setup SMS Alert/Auto
dial Numbers.
3) Caps Lock letters in the SMS.
1) Please setup the SMSAlert Numbers;
2) Please help to see the sample of setup the telephone numbers;
3) Please check the commands with CAPS LOCK and correct format.
4) Also, please help to change another GSM Operator SIMCard to test it.
Other manuals for S130
1
This manual suits for next models
2
Table of contents
Other King Pigeon Controllers manuals
Popular Controllers manuals by other brands

Pixsys
Pixsys DRR227 user manual

Mitsubishi Electric
Mitsubishi Electric MELSEC-F FX1N-422-BD user manual

Ultraflex
Ultraflex B47 installation instructions

Rockwell Automation
Rockwell Automation Allen-Bradley MicroLogix Reference manual

Western Co
Western Co WRM15 dualB user manual

KNX
KNX GIRA 5065 00 operating instructions