Kingeye ki-g18 User manual

User Manual for GSM / LED Touch Keypad Wireless Intelligent Home Alarm System
I. Foreword
Thank you for purchasing and using GSM / LED touch keypad wireless intelligent home alarm system. This is a
Hi-performance and Hi-tech household security product. It will make your life safer and more colorful.
Please read the below information carefully before using for a proper usage.
II. Brief introduction of the Product
A. Product components: This product is composed of alarm host, basic accessories and optional accessories.
Alarm Host Basic Accessories Wireless Optional Accessories
GSM/ LED
Touch Screen
Alarm Host
wireless remote, wireless
door sensor,
wireless wide-angle PIR
sensor, wired indoor siren.
intelligent door sensor, intelligent control door sensor, high
capacity li-ion battery wide-angle PIR sensor, gas alarm, smoke
alarm, indoor siren with sound and light, outdoor siren with
sound and light, doorbell button, LED keypad, LCD keypad and
more.
Table 1: Product components
III. Function Features
zTouch keypad, concise LED display. Nice looking and easy operation.
zCompatible with GSM network, reports alarm events by calling and SMS.
zUse SIM card,upto 6 phone numbers(2 for management center, 4 for personal) can be pre-stored and then dial in
sequence when alarming. Each number can be set as phone call alarm or SMS alarm according to actual needs.
z15 wireless zones (Each zone supports up to 4 sensors) and 1 dedicated zones for remotes (Supports up to 10
remotes). 8 wired zones can be extended and each wired zone can be separately armed and disarmed.
zRecord up to a 10 second voice message in the host, then can be heard via phone when answering alarm call.
zIntelligent logic analysis technology, corresponding zone number can be displayed by LED lights. Corresponding
zone number and sensor name can be displayed via SMS.
zDisconnection alarm, auto priority to occupy the telephone and monitoring function to hear what is happening.
z5-ways of arm/disarm:SMS, remote controller, built-in keypad, wireless keypad(optional device), phone call.
zNon-volatile chip, information stored automatically when off power.
zOne-key arm,learning sensors to alarm host, very easy operation.
zBuilt-in Li-Ion backup battery, available in AC\DC. System self-check, alert of low backup battery power.
zSupports CID uploading to CMS(Center monitoring Station) , can user our GSM CID connector to have this
function.
zExtended Functions: Wireless “Ding Dong” doorbell.
Open and closed status (of door and window) mornitoring and alert
Wireless siren with sound and light
WirelessDVRfunctions.
And more.
IV. Understanding of the Products
A. Understanding of the Alarm Host
A
way
Ho m e
Em e rg e n c y
Learning
Pro g ra m
LED display for wireless zones

Working power:AC=100~240V DC=12VDC (1A)
Static current:≤50mA(when not charging), Alarm currnt:≤500mA
otes, 60 wireless sensors.
zr
zn battery, 3.7V / 1200 mAh
zS
A
larm lights for wired zone s
A
rm & d isa rm lig hts f o r wire d zo ne s
LED display for wired and wireless zones
/
Signal/PowerLight
Lo w - Po w e r Li g h t
Mic
StatusLight
Em e r g e n c y Num b e r Disa rm /ESC Co nfirm
Pro g ra m
Awa y
Ho m e
Install GSM antenna here
Fro
nt Side
S I
Back Side
1. Specifications:
z
z
zSuppots upto 10 wireless rem
Wo king condition: Temperature:-10~50℃Humidity:<80%
Back-up battery: Li-io
tandby: 24 hours
Sp e a ke r
kup Battery ON/OFFBac
Po w e r
Extend 8 Wired Zones here
Optional
()
ON
OFF
Connect Wired Siren Here
Re c o r d
Play
SIM
M C ard S l ot

zChar
zGSM MHZ),Quad-Band(850 / 900 / 1800 / 1900 MHZ)
zGSM
z
2. Zo ns
zZ
ce like doors, windows, etc., generally use wireless door magnet sensors
rtain PIR sensors
wide
y use panic button, wireless
g
zones get triggered, the host will alarm
“antime
d
4. How to operate the alarm host
zPreparation
1. Insert SIM card properly: keep the m
2. Fix t antenna attached in p otating it to the port on
3. Connect p nect the power irs
4. de the backup ba n the back side of the host
ck and see if GSM signal is good enough
GSM Signal OK Signal is not normal or SIM card not
inserted properly
ging time: 12 hours
frequency: Dual-Band(900 / 1800
emitting power:2W
Product dimension(host) 150×107×26(mm)
ne types and definitio
one types: Perimeter zone, Motion zone, Emergency zone
zDefinitions:
Perimeter zone: Detecting the spa
and wireless cu
Motion zone: Detecting the space like living room, aisles and bedrooms, etc., generally use wireless
-angle PIR sensors.
Emergency zone: Detecting the space like Emergency area (such as emergency distress, medical rescue,
gas leakage and
fire alarm, etc., this zone keep 24-hour monitoring status automatically. Generall
gas sensors and
wireless smoke sensors.
3. Modes of armin
z“Away Arm” mode:Once any detectors in perimeter zones or motion
immediately and meantime dial “#” automatically.
Home Arm” mode:Once any detectors in perimeter zones get triggered, the host will alarm immediately and me
ial “#” automatically. It will not alarm after any detectors in the motion zone are triggered.
issed conner at the right lower side.
ackage by r
he antenna: Install the top of the host.
ower: con adaptor to DC port of the alarm host f
ttery switch o
t, then plug it to the AC socket.
to “ON”
Turn on the backup battery: Sli
5. Che
Type
2-Band Signal light keeps flash about every
(900/1800 MHZ)2 seconds Signal light keeps on
4-Band Signal light keeps flash about every Signal light keeps flash about every
(850/900/180 MHZ)3 seconds 1 seconds
0/1900
zStart to p
Note:
zNo op thin 20 seconds after pressing any key, the alarm host will exit from the programming status.
zAny operation is effective only after 【Start to progra ad to previous step;
und “Di Di----” from the alarm host indicates su i” indicates failed operation
clas on
(For users) p
Cod
e struction
Setting
rogram
eration wi
m】, any pressing on ESC will le
ccessful operation,“Di D
zThe so
sificati To be
rogrammed Setting Operation In Default
Start to
program —— SET + XXXXXX+ ENT 8 8 8 8 8 8
“XXXXXX”:6-digit program password
N
know Input phone 0 + X+ ENT +Tel
+
Y+ENT
cludes1~6.
protocol.
“3~6” for personal.12 digits at most.
No number
ecessary to
numbers 0 number+ ENT
“X”:Group number of telephone
numbers,in
“1” for C ID protocol.
“2” for XSJ
“Y”: 0 or 1. (“0”: phone alarm; “1”: SMS

alarm)
1 “X”: 0 or 1. (“0”: 0 second; “1”: 15 0
1 + X+ ENT seconds)
Exit delay
Entry delay 2 + ENT 15
seconds) 0
2 + X“X”: 0 or 1. (“0”: 0 second; “1”:
Emergency
alarm sound 3 3 + X+ ENT “X”: 0 or 1. “0”:silent;“1”:audiable;1
Perimeter
4 4 + X+ ENT “X”: 0 or 1. “0”:silent;“1”:audiable;1
zone, motion
zon alarm
sound
Program “X”: 0 or 1. (“0”:add; “1”: delete)
0~15” No setting
wireless
sensors
7 7 + X+ENT+ Y Y +
ENT “YY”: Zone numbe. Includes“0
May know
check
se ; “1”: open) 0
On/Off of door
& window state 9 9 + X+ ENT “X”: 0 or 1.(“0”:clo d
If upload arm &
disarm to
management
center
5 5 + X+ ENT “X”: 0 or 1.(“0” Not upload; “1”: Upload) 0
Unnec
to kno
8 + 0+ ENT+ X X X X No code
essary
w
User Code 8 + ENT “X X X X”:4-digit user code
Table 2: Program Setting
N
zsword(Users must know and operate)
:
ENT】
Notes
4. Ho
the speaker of host.
z
the o
zDisa p twice to successfully
com
ote: Press ESC to exit from the programming state after finishing programming.
How to change programming pas
In order to keep program password safe and to be easily remembered, users can change it via below setting
【SET + 999999 + ENT + Six Digital New Programming Passwords + ENT + Six Digital New Programming
Passwords +
:
1. Press SET, then programming light on.After finishing setup, programming light off.
2. The sound “Di Di----” from the alarm host indicates successful operation,“Di Di” indicates failed operation
w to operate the Alarm Host? (Necessary for users to know and operate)
zRecord:Kee lose to
p pressing the “record button” on the back of the alarm host and speak c
Then release, the voice recorded.
zPlay:Keep pressing the “play button” on the back of the alarm host and you will hear the previous record.
Arm:BY wireless remote:press the corresponding arm button and the host will beep once to successfully complete
peration
By Host panel(Keypad): press“▲▼”to choose “armed away” or “armed home”
rm: By wireless remote: press the corresponding disarm button and the host will bee
plete the operation
By Host panel(Keypad): 【ESC + master code + ENT 】→the host will beep twice to successfully complete
the operation
zEmergency: By wireless remote: Press Emergency key and the host will alarm immediately;
By host panel(Keypad): press ,and the host will alarm immediately.

zm: After receiving the call, you will hear the recorded voice message immediately, it can be played
ut “8” to enter into the listening status for 20 seconds automatically, you can hear the alarming event
, the host will end the call and stop dialing any auto dialer#.
zXX, YYYY”, “XX” means zone number, “YYYY” means the detailed
tically hang up after beep to successfully complete
the operation.
otely by phone, but keep notes that you can’t set “Armed Home” by
zword
the operation.
zAr
an ly”.
N
t panel would disarm automatically when getting this
SMS, a
zarm and disarm of 8 wired zones: When the host is armed, press “1~8” number key can arm/disarm the
Monitor open and closed states of door and window: When the smart zone is ON, the arm operation is normal if all
ors or windows are closed. But if any door or window is open, the host will sounds “Di Di Di” and at the
sa
No
operation.
zof the doorbell
No function, need to add and program a wireless doorbell button.
5. C io
zAlarm processing mode: immediately after the system alarms, it starts to dial in sequence from the 1st group
5th group number(skip empty numbers) automatically. It dials circularly for three times, the
answered number and the numbers succussfully reveived SMS will not dial repeatedly.
lay host co ) within preset exit delay
zAlarm delay alert: the alarm host sounds “Di” eve alarm delay time.
rm priority: The alarm ho ou rep
alarms s “Ding Dong” .
ernal power supply cut ale so
zLower voltage alert: Low-Power light on the host
Wireless zones:
Zone Type Applicable Sensor Name Remark
Telephone alar
for 30 seconds repeatedly, then follow the below instruction:
1. Inp
sounds from phone. Each extra press of “8” can prolong 20 second listening in.
2. Input”#” to play the recorded voice message for one time automatically
3. Input “*”
4. Directly hang off the telephone, the host will end the call and automatically dial the next auto dialer#.
SMS reporting: Mobile will get SMS like “ System Alarming
sensor.
zArm remotely by phone: 30 seconds after successfully dial the telephone number of host, enter the password of
host after the beep---enter 1 after beep—the host will automa
Notes: You can set “Armed Away” rem
this way.
Disarm remotely by phone: 30 seconds after successfully dial the telephone number of host, enter the pass
of host after the beep---enter 0 after beep—the host will automatically hang up after beep to successfully complete
m by SMS: You can edit SMS “ XXXXXXBF” to host panel, the host panel would arm automatically when getting this SMS,
d also will message back to mobile “Arm successful
otes: Arm by SMS is only for “Armed away”!
zDisarm by SMS: You can edit SMS “ XXXXXXCF” to host panel, the hos
nd also will message back to mobile “Disarm successfully”.
zHow to use the extended functions:
Separate
cooresponding zone. Status light of the cooresponding zone on indicates armed, off indicates disarmed.
the do
me time the status light flashes frequently.
te: 1. This function is available only with wireless intelligent door sensor programmed.
2. If arm by phone call, the operation is same as original.
3. If arm by remote controller or wireless keypad, it will arm successfully after two succsessive arm
Wireless “Ding-Dong” doorbell: the alarm host will sounds “Ding Dong” three times after each press
button.
te: This is an optional function. To have this
aut ns
number to the
zExit de alert: the alarm sounds “Di” every 1 se nd (door/window is closed
time.
ry 1 second within preset
zAla st’s “Ding Dong” s nd will switch to alarm sound and dial to ort if it receives
ignal when sounds
zExt rt: the alarm host unds “Di” every 8 seconds.
will be on when power gets very low.
z
Zone Number Sensor Type

W te & Wireles d00 —— ireless remo s Keypa
01 ~ 05 Emergency zone Wirele moke Alarm,
Wireless Gas Alarm& Panic button etc.
ss S
06 ~ 10 Perimeter zone Wireless Curtain PIR etc.
Wireless Door/Window Sensor &
11 ~ 15 Motion zone etc.
Wireless sensors
Wireless Wide-Angle PIR Motion Sensor
Su s upto
4 wireless
sensors for
each zone
pport
Note:Default set before shipment
Wireless Wireless Wireless door Wireles
sensor remote sensor PIR s
s wide-angle
ensor
Wireless gas
sensor
Wireless
smoke sensor
Zone Number 00 06 11 02 03
How to connect optional wired sensors (no need to connect
2.2K balance resistors)
White Zone 1 door sensor
Yellow Zone 2 curtain PIR sensor
Blue Zone 3 curtain PIR sensor
Green Zone 4 wide-angle PIR sensor
Purple Zone 5 wide-angle PIR sensor
Brown Zone 6 panic button
10
NC. They will get open when alarming. No need to connect 2.2K balance
resis
1
Red + sensor+12Vpoweroutput
Black - GND
Grey Zone 7 gas sensor
Orange Zone 8 smoke sensor
Wire connection notes: sensors have to be
tor
+ +
GND
ARM
GND
ARM
GND
+
GND
ARM
NC
Sensor zone port Sensors w/o power supply Alarm host zone port
s w/power supply Alarm host
B. Understandi
Wireless Rem
ng of Basic Accessories
ote
Features
z
zurgent help.
:
To control the alarm host to arm and disarm.
With the emergency key for
Away
Disarm
Home
Specif
zOperating power: 27A 12V alkaline battery
distance: ≥100m (in open area)
ervice life: ≤1 year
ications:
Emergency
zEmitting
zS
Installation and Usage:
zFor users to take along.
zGenerally, press the “Away” key to arm before leaving home; and press the “Disarm” key to disarm;

Home” is only effective for sensors in
r Zone (door sensor\curtain PIR sensor) and sensors in Emergency Zone (Like Gas
\Emergency button), it is not effective all sensors in Motion
when you feel shorter control distance.
“Home” is setting “Armed home”, please take notes that “Arm
Perimete
sensor\Smoke sensor\Glass sensor
zone(Like wide-angle PIR).
zPlease replace the batteries after one year usage and
How to program
A.Add
1.【Start to program】(Please refer to Table 2)
2.【Wireless configuration】:【70 + ENT+ 00 + ENT】(At this time, “Learn” light keep on)
y on remote controller twice successively, if you hear “Di----” form the alarm host and see the
“L ashes five times and off, it indicates successfully added.
B. Dele
3.【Star
4. guration】:【71 + ENT+ 00 + ENT】if you hear “Di Di---” form the alarm host and see the “Learn”
light flashe
Notes: 1. Yo e, totally 10 available to be add
2. A are cancelled after your cancelling operation. You have to do the adding
operation
Wireless Door
Press any ke
earn” light fl
te
t to program】(Please refer to Table 2)
【Wireless confi
s two times and off, it indicates successfully cancelled.
u can only add 1 remote controller each tim ed.
ll the remote controllers
if you need one or more.
Sensor
Features
z
:
zGenerally set as Perimeter zone.
If any door or window is opened, it will transmit the alarm signals to the alarm host.
Specifica
zEmitting distance: ≥100m (in open area)
Alarm Distance: <4cm
tions:
zOperating power: 23A 12V alkaline battery
zService life: ≤1 year
z
Installation and Usage
zFix the part of magnet onto the door frame in a position of 1.6m
ure to keep the
art of magnet and part of emitting in parallel, the space between the two parts shall be less than
above the ground to prevent any children from bumping onto it
zFix the part of emitting onto the door frame, make s
p
10mm
zUpon the working light flashes frequently in blue, please replace the batteries
How to add and delete door sensors
A. Add
1.【Start to program】(Please refer to Table 2)
【Wireless configuration】:【70 + ENT+ XX
2. + ENT】(At this time, “Learn” light keep on)
Notes: “XX” indicates group number of defense
Trigger the door sensor twice successively, if
light flashes five times and off, it indicates successfully added.
rogram】(Please refer to Table 2)
WT+ XX + ENT】if you hear “Di Di---” form the alarm host and see the
“Learn” light fl uccessfully cancelled.
Notes: 1. You can only add 1 wireless door sensor each time. Each group is available to add 4 wireless door sensors
zone, including 01~06.
you hear “Di----” form the alarm host and see the “Learn”
B. Delete
1.【Start to p
2.【ireless configuration】:【71 + EN
ashes two times and off, it indicates s

3. Al less door sensor in this group are cancelled after your cancelling operation for one group . You
have to do the adding operation if you need one or more.
Wireless
2. When exceeds 4,the latter added wireless door sensors will cover the former added one.
l the wire
Wide-Angle PIR Sensor
Features:
zM
stereoscopic space, generally set in
ainly monitor and control indoor
Motion Zone.
zWhen human body enters into the
detecting area, the sensor will transmit
the alarm signals to the alarm host.
S e
zEmitting distance: ≥150m (in open area)
etecting distance: 110° 10×10m
p cifications:
zOperating power: 9V alkaline battery
zService life: ≤1 years
zD
Installation and Usage
zFix the bracket on suitable wall surface or in wall corner at a distance of 2~2.4m above the ground;
the sensor onto the bracket;
he power switch on the side to “ON”, and it will enter
conds;
zOpen the sensor shell to connect the batteries well and adjust jumper line (short circuit “5S”: The sensor
will detect once every 5 seconds; short circuit “5MIN”: The sensor will detect once every 5 minutes;
suggestion: short circuit “5S” for testing and “5MIN” for normal use;
zFix
zAdjust the sensor to a proper angle and then slide t
into the normal working state after 30 se
zUpon the working light flashes frequently in blue, please replace the batteries.
How to add and delete door sensors
A. Add
1.【Start to program】(Please refer to Table 2)
Wireless configuration】:【70 + ENT+ XX + ENT】(At thi
2.【s time, “Learn” light keep on)
Notes: “XX” indicates group number of defense zone, including 11~15.
mitting Switch” twice successively to trigger PIR sensor, if you hear “Di----” form the alarm
host and see the “Learn” light flashes five times and off, it indicates successfully added.
ram】(Pleas )
r “Di
light flashes two times and off, i
i
When exceeds 4,the la
3. All the wireless PIR se p are cancelled after
have to do the adding operation if you need one or more.
Press the “Learning E
B. Cancel
1.【Start to prog e refer to Table 2
2.【Wireless configuration】:【71 + ENT+ XX + ENT】if you hea
t indicates successfully cancelled.
Di---” form the alarm host and see the “Learn”
Notes: 1. You can only add 1 w
2.
reless PIR sensor each time. Each grou
tter added wireless PIR sensors will cov
nsors in this grou
p is available to add 4 wireless PIR sensors
er the former added one.
your cancelling operation for one group . You
Wired Siren (omitted)
V. Common Problems and Solutions
Symptoms of Faults Possible Cause Solution
The alarm host can’t fully record
Did
wh
not keep pressing the record
button all the time while recording
Keep pressing the record button all the time
ile recording
OFF ON
Em i t t i n g b u t t o n
Po w e r Ri g h t : O
Sw i t c h
N
Le f t : O FF
”
Lo w
power
light

Repeatedly receiving the alarm
telephone
Fail to operate according to the
operation instruction of the
telephone alarm
Fo after answering
re e:
Hos
llow the below instructions
the alarm phone calls and hearing the
corded messag
(See Point 6 of “How to operate the Alarm
t?”)
Can’t receive alarm sms or
can’t receive sms reply after 2. d enough Aill
made arm or disarm operation
by sms
1. SIM card is not insert properly
GSM signal is not goo
1. Insert SIM card properly
2. djust alarm host’s installation position t
the signal status shows “OK”
The host does not alarm after
the detector is triggered in arm mode (Armed Away and Armed
Motion zone is triggered
state
1. Caused by the functions of arm
Home);
2. Have already setup time for Entry
Delay or Exit Delay
1.“Armed Away” mode: alarm goes off when
any sensor is triggered;
2. “Armed Home” mode: alarm goes off when
any sensor in Perimeter zone is triggered
and it won’t alarm when any sensor in
3. Program to adjust the time for Entry Delay
or Exit Delay
The PIR sensor doesn’t work d to the
is in the
tect once every 5 minutes;
1. Not properly connecte
power
2. Port of the detector
power-down mode.
1. Open the sensor shells to install the
batteries well and slide the power switch
to “On”;
2. “5S”: detect once every 5 seconds;
“5MIN”: de
The detecting distance of PIR The ambient temperature in the
g area is too high.
When the ambient temperature in the
detecting area exceeds the human body
sensor gets shorter detectin
temperature, the detecting distance will get
shorter, it’s normal.
The host does not alarm after Failed to follow the operation Follow the operation instruction of “Ho
the new added wireless instruction of “Adding and dele
detector is triggered. sensors” to add the new wireless
sensor
ting
w to
program” to activate the new wireless sensor
The PIR sensor flashes
e ently in blue.
Batteries are running out. Replace with new batteries of the same
specification.
fr qu
Th door sensor’s indicator
flashes frequently.
Batteries are running out. Re
spe
e place with new batteries of the same
cification.
The distance of the remote
roller gets shorter.
Batteries are running out. Replace with new batteries of the sam
cont
e
specification.
VI. D tenance and Care
This alarm is the hi-tech product with the outstanding design and sophisticated technique, and shall be used carefully.
To make the alarm to operate for a long term stably and to prolong the service life, it is recommended that:
zTry to put the alarm host in the dry and well-ventilated places.
zDo not put the host and any wireless detectors in too cold, too hot or dusty places to prevent it from curtailing the
service lives of electric parts and preventing the plastic shell from distorting and accelerating to age.
zDo not put the host and any wireless detectors in low and too exposed places to prevent the children from touching
them or the thieves from finding them.
zRegular testing is necessary for finding and resolving problems in time.
zRegularly check the batteries in all wireless sensors and replace the running out batteries to ensure the normal
operation of them.
zYou’d better keep the power of the alarm host and all wireless accessories off while a long-time vacancy of the
system.
aily Main