Klimasan S 56 SC User manual

S 56 SC
S 88 SC
S 149 SC
S 149 SL
S 149 WIC ST
S 149 WIC H
S 240SC M1
S 240SC M1C
D 372 SL M4
D 372 SC M4
D 372 SC M4 TD
D 372 SC M4C
D 372 SC M4C TD
D 372 SC M4C STD
D 372 SC M5C
D 372 WIC ST
D 372 WIC H
D 418 G CD
D 418 G CD C
SC 505 HP
SC 505 STD
SC 505 TF
SC 600 STD
SC 600 HG
S 650 SC


Part 9.1. For Model With Electronic Control System
Part 9.2. For Carel Ecobox And Carel Energy Saving Controlled Models
1

3. PRECAUTIONS AND SAFETY INSTRUCTIONS BEFORE THE
INITIALSTART-UP
Your visi/cooler must be plugged certainly in an earthed wall
socket.
Before operating the visi/cooler, ensure that the mains socket is
checked for proper earthing (grounding) and nominal voltage and
frequency requirements by the authorized service staff or a qualified
electrician. If the supply cord is damaged, it must be replaced by the
manufacturer, oritsauthorizedserviceorasimilarlyqualifiedpersonin
ordertoavoidanyhazard.
Donotusemultisocketandextensioncable.
The main power supply to which the visi-cooler is connected
must have a leakage current relay.
The nominal voltage and frequency requirements for the body are
specifiedonthedataplate.
Never make any repairs or carry out maintenance while the
visi/coolerispluggedinthemainssocket.
Do not position the visi/cooler in a place, close to a source of strong
heat or exposed to direct sunlight.Always remember that the UV lights
in the sunlight deteriorates food in the glass door visi/coolers. The
appliancecanbeusedinambienttemperatureofmax.32°C.
Unlessotherwisestated, donotplace yourcoolerto openareaswhere
watercanleakin.
Donotwashwithpressurizedwaterorhosewhen cleaningtheproduct
and its surroundings, use a wet cloth. Otherwise, the water which may
intrudeinto theelectrical componentsoftheproduct cancause electric
shockandfirerisk.
Start the visi-cooler on a level surface. Position it on the floor and
make sure that it is level using a bubble gauge. If the visi-cooler is
found to tilt in one particular direction, please adjust the height of
the corresponding leg until it is level. Then please move the
visi/coolertothelocationwhereitwillbeused.
2

Do not relocate the cooler or move the cooler on its rollers while
its loaded with product. If cooler is empty, please do not push the
cooler to pass over cables or door frames, to avoid roller
damages. Never push the cooler when the pavement is uneven,
havinginclination,ortherearestairsnearby.
All the components that produce heat are located at the bottom part of
yourvisi/coolerexceptthemodelsS56SCandS88SC.Thesemodels
havetheheatproducingcomponentsonthetop.
Proper air circulation at this part is very important to ensure
performance, therefore while positioning the visi/cooler, allow
minimum10cmofspacefromthesides.
Canopy lamps of S 56 SC and S 88 SC can be replaced only by
skilledpersons.
Donotletchildrengetintoandplayaroundthebody.
Keepthevisi/coolerkeyandplasticbagscoveringtheaccessoriesand
theManuelinasafeplaceoutofreachofchildren.
Donotplaceanyexplosivesandflammablesinthevisi/coolerforsafety
reasons.
Leavethetopofthevisicoolerfree,sothathotairfrombottomcan
circulateeffectively.
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenanceshallnotbemadebychildrenwithoutsupervision.
3

PLEASE CHECK YOUR REFRIGERANT GAS TYPE FROM THE
RATINGLABEL: R134a,R600a, R290orR744(CO )
2
OnlyforthemodelswithR600aorR290gas:
R600a/R290 gas is used in some models, explained in this
instruction manuel. R600a/R290 is an environmentally friendly
gas and used in appliances which have effective cooling
technology. This gas is flammable only under certain conditions.
You must follow up the following rules if you wish to get normal
operatingconditions.
WARNING : Keep ventilation openings, in the appliance
enclosureorinthebuilt-instructure,clearofobstruction.
WARNING : Do not use mechanical devices or other means to
acceleratethedefrostingprocess.
WARNING : Donotdamagetherefrigerantcircuit.
WARNING : Do not use electrical appliances inside the food
storagecompartmentsoftheappliance.
WARNING : In order to reduce flammability hazards, the
installation of this appliance must only be carried out by a
suitablyqualifiedperson.
Do not tangle with the device due to maintenance, repair or any
otherreasonsotherthanauthorizedservice.
Plug off the device against any possible freezing or icing and
leavefordefrosting.
Choose original components for all parts necessary for
replacementontheproduct.
4

OnlyformodelswithR744( )gas:
WARNING: The refrigeration system is under high pressure. Do
nottamperwithit.
Contact qualified service personal before servicing. Please
ensuretocomplywithlocalregulations.
Pressure
Thesymbol onthe leftmeansthat thecooling systemisunder the
high pressure and your appliance was marked with a warning
labelwhichcontainsthissymbol.
This Cooler uses CO Refrigerant that operates at High
2
Pressures. A High Pressures Safety switch is used to protect the
system from exceeding the desired safety limit. When the
pressure switch activates it cut off the power supply to the
Controller, which in turn shuts the complete cooler down. After
the system pressures come back to the normal range, the
Pressure Safety Switch is deactivated & the cooler starts to
operatenormalagain.
Ifthesupplycord isconnectedtotheplug andthe coolerdoes not
operate (lamps are off, all electrical components are off), please
unplug the cooler and call a qualified service technician who has
experience with CO refrigerators & is authorized to work with
2
CO refrigerators. Please do not try to repair the cooler by
2
yourself.
CO2
5

6
1
2
3
4
5
67
89
9810
11
11
12
12
11
13
13
1 - Door
2 - Power compartment
3 - Shelf
4 - Adjustable height
5 - Interior ventilation fan
6 - Canopy
7 - Green light
8 - Thermostat setting knob
9 - Lighting switch
10 - Fan switch
11 - Interior lighting
12 - Thermometer
13 - Electronic thermostat (optional)
4. TECHNICAL FEATURES OF SINGLE DOOR VISI-COOLERS

S 56 SC S 88 SC
0/+10 0/+10
337x303x450
435x488x740 398x361x557
490x546x840
S 240 SC M1 S 240 SC M1C
0/+10 0/+10
490x553x1070
600x621x1366 595x653x1500
600x621x1366
42 42
D 418 G CD D 418 G CD C
0/+10
0/+10
497x534x1552
595x664x1936 595x695x2118
497x534x1552
S 149 SC
S 149 SL
0/+10
490x466x670
595x645x840
•S 149 WIC H •S 149 WIC ST
490x466x670
595x645x840 490x466x670
595x645x840
•S 149 WIC ST and S 149 WIC H model coolers should only be used for wine conservation.
Values specified above tables are given according to standard values and can vary by optional
features.
7

D 372 SC M4
D 372 SL M4
D 372 SC M4 TD D 372 SC M4C STD
0/+10
0/+10
490x453x1070
595x653x1500
D 372 SC M4C
D 372 SC M4C TD
0/+10
490x447x1570
595x650x2000 490x447x1570
595x620x2000
SC 505 TF
0/+10
SC 505 STD
SC 505 HP
0/+10
615x469x1343
695x615x1997 625x425x1358
720x610x1997
S 650 SC
0/+10
SC 600 STD
0/+10
SC 600 HG
0/+10
615x608x1343
695x754x1997 615x608x1570
695x754x2201 616x682x1355
695x815x1981
D 372 SC M5C
0/+10
490x447x1570
595x650x1870
•D 372 WIC H •D 372 WIC ST
490x453x1070
595x653x1500 490x453x1070
595x653x1500
•NOTE : D 372 WIC ST, D 372 WIC H, S 149 WIC ST and S 149 WIC H model coolers should only
be used for wine conservation.
•D 372 WIC ST and D 372 WIC H model coolers should only be used for wine conservation.
Values specified above tables are given according to standard values and can vary by optional
features.
8

Class Temperature °CRelative Humidity %Dew Point °C
Climate Classes
0
1
2
3
4
5
6
7
8
20
16
22
25
30
27
40
35
23,9
50
80
65
60
55
70
40
75
55
9,3
12,6
15,2
16,7
20,0
21,1
23,9
30,0
14,3
9

PLEASE INSERT SHELVES AS
SHOWN, KEEPING PRICE LOGO
STICKER STRIP IN FRONT.
STICKER STRIP
MountingtheShelves:
Thereare 5shelves providedwith themodels ;3 with ;2 withS 149and
S88SC;and1withS 56SC. Firstinsert theuppermostshelfinthe uppermosthooks inthe bodyInsertthe
otherscorrespondinglywiththesamemethod.Chillingprocessinthebodytakesplacethroughtheinternal
aircirculation.Thereforedonotplacetheshelvesveryclosetooneanother.
D372, D148, SC505TF S240 SC
For models SC 505 HP , SC 505 STD, SC 600, S 650 :
WARNING:
Yourcoolercanhave afluorescentlamp.Ifthefluorescentlamp don'tilluminateorstarttoblinking,
please call techical service to repair it in a short while. Please do not remain your cooler with non
workinglightingsystem.
10

11

12

ATTENTION:
The defrost button can be used to set the cooler manually on defrost mode which will last for 10 minutes
COMPRESSOR (Compressor light) : If green light is on, it shows that compressor is active.
FAN (Fan light) : If green light is on, it shows that inner fans are active.
On screen of the control panel, symbols stated below can apeear depending on the type of the
trouble that maybe formed and cooling mode of the cooler.
"USE" : Your cooler is ready to use.
"–––" : Your cooler is in stand-by mode.
"888" : Your cooler is in protection against freezing mode.
“dO" : It shows that door is open.
"dEF" : System is in defrost mode.
"rSF" : There is problem at cooling system, contact your cooler maintenance.
"SLO" : Cooler is shut down because the voltage is low.
"SHI" : Cooler is shut down because the voltage is high.
"Pf1" : Input problem, contact your cooler maintenance.
1 2 3 4 5 6 7
8 9 10 11
13

Control unit flashes for a few seconds in order to check if all
connectionsaremadecorrectlywhenthecoolerispluggedin.Thisis
normal, then the display will indicate current temperature. Set
temperature has been adjusted to keep your beverages at optimum
temperature,pleasedonotattempttochangethesettings.
9.2 FOR CAREL ECOBOX and CAREL ENERGY SAVING CONTROLLED MODELS:
LIGHT : Pushing at lest 0.5 seconds the keypad, the light status will be toggled. Pushing the
keypad,andbefore than thelightstatus will betoggle,the display willshow"On" or "OFF"inorder
towarnhowthelightstatusisgoingtochange.
DAY/NIGHT MODE : The thermostat changes its mode automatically. If the door continuously
closed for more than 4 hour the thermostat mode will be night and the lights of cooler will be off.
Lights can be on/off by pushing the light button. If the door is opened at the night mode, the mode
willbeday.Atthe nightmodeyour cooler consumelessenergy. If youwantto changethemode to
thenightyoumustto pushtheday-nightbutton,after60second fromthepushingthemodewillbe
night.
ECO MODE: Pushing the keypad at lest 3 seconds the ECO mode will toggle (if ECO
mode is running then it will end, if ECO mode is waiting then it will start). Pushing the
keypad, before then the ECO mode will toggle, the display will show "ECO" mode will
toggle, the display will show "ECO" (Economy) or "nor" (normal) in order to warn how the
functioning mode is going to change. If the thermostat is at the ECO mode, the cooler will
consumelessenergy.
CAREL ECOBOX CAREL ENERGY SAVING TYPE 1 CAREL ENERGY SAVING TYPE 2
14




B6019507_K11
This manual suits for next models
24
Table of contents
Other Klimasan Accessories manuals
Popular Accessories manuals by other brands

AsashiKASEI
AsashiKASEI SenseAir eSENSE installation manual

Flightcom
Flightcom CONNECT quick start guide

Sterling
Sterling 25001301 Installation and Maintenance

IVDT
IVDT SkidWeigh ED2E-EP Series Installation & Calibration Manual

TeraBee
TeraBee TeraRanger Evo user manual

ThunderDog
ThunderDog TH4000BB instruction manual

Sani king
Sani king Perform-Max 920 instruction manual

Dometic
Dometic COOLPRO TC 14 Operation manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 641B61 Installation and operating manual

Orbit
Orbit B-HYVE 71003 manual

Lanberg
Lanberg SM01-WP10 user manual

ATON
ATON Source Input Wall PlateWallplate DHSIP product manual