Kohler Mira Play User manual

1 1341122-W2-C
Mira Play
8.5, 9.5 and 10.8 kW Electric Shower
CH
T
emperature
P
ower
Play
These instructions must be left with the user
Installation and User Guide
For SPARES,
ADVICE or REPAIRS
please call us free
on 0800 001 4040
(UK only)

21341122-W2-C

3 1341122-W2-C
WARNING - This shower can deliver scalding temperatures, cause
re, electric shock or other personal injury if not operated, or
maintained in accordance with the instructions, warnings and
cautions contained in this guide and on the appliance.
Please read the important safety information and the operation section
of this guide before using the shower. Failure to follow the instructions
provided with this shower will invalidate the guarantee.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
1. Children younger than 3 years should not use this shower. Children
3 years to under 8 years should only use this shower under
continuous supervision. Children aged 8 years and above and
persons with reduced physical, sensory or mental capabilities or
lack of experience or knowledge can use the shower if they are
given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved.
2. Children shall not be allowed to play with the shower.
3. DO NOT restrict the water ow from the shower outlet, temporarily
bending the shower hose or blocking the shower head while in use
can cause a hot shot of water to be discharged.
4. Cleaning and user maintenance shall not be made by children
without supervision.
5. The outlet must not be connected to any tap or tting other than
those specied.
6. The showerhead must be descaled regularly. Any blockage of the
showerhead or hose can cause damage to the shower.
7. Warning! DO NOT switch on if there is a possibility that the water
in the heater is frozen.
8. The shower must be provided with means for local disconnection
from the supply mains having a contact separation in all poles
that provide full disconnection under overvoltage category III,
the instructions state that means for disconnection must be
incorporated in the xed wiring in accordance with the wiring rules.
Important Safety Information

41341122-W2-C
9. Installation of the shower must be carried out in accordance with
these instructions by qualied, competent personnel. Read all
instructions before installing the shower.
10.DO NOT switch the shower on if water starts leaking from the shower
case. Isolate the electrical supply to the shower immediately.
11.DO NOT switch the shower on if the case appears to be damaged
or incorrectly tted. Isolate the electrical supply to the shower
immediately.
12.DO NOT increase the power setting or adjust the temperature
control rapidly while using the shower.
13.DO NOT switch the shower o and back on while standing in the
water ow.
14.DO NOT change the handset model. Fit only shower heads
recommended by Mira and do no t any additional device to restrict
the water outlet ow.
15.When adjusting the handset mode, point handset away from body
and make sure that the water temperature has stabilised before
continuing to shower.
16.Use caution when altering the water temperature, always check
the temperature before continuing to shower.
17. Switch the shower o at the electrical isolating switch when not in
use. This is recommended with all electrical appliances.
18.Installation of the shower must be carried out in accordance with
these instructions by qualied, competent personnel. Read all
instructions before installing the shower.
19.Isolate the electrical and water supplies before commencing
installation. The electricity must be isolated at the consumer unit
and the appropriate circuit fuse removed, if applicable. Mains
connections are exposed when the cover is removed.
20.DO NOT install the shower in areas with high humidity and
temperature (i.e. Steam rooms and saunas).
21.DO NOT install the shower where it may be exposed to freezing
conditions. Ensure that any pipework that could become frozen is
properly insulated.

5 1341122-W2-C
22.DO NOT connect the outlet of the shower to any tap, control valve,
trigger operated handset or showerhead other than those specied
for use with this shower as the outlet acts as a vent for the tank
body. Only Kohler Mira recommended accessories should be used.
23.DO NOT perform any unspecied modications, or drill or cut holes
in the product other than instructed by this guide. When servicing
only use genuine Kohler Mira replacement parts.
24.DO NOT connect this shower to a Waste Water Heat Recovery
System as this may cause unstable or scalding temperatures to
be delivered from the shower head.
25.Always check the water temperature is safe before entering the
shower.
26.The water supplies to this product must be isolated if the product is
not to be used for a long period of time. If the product or pipework
is at risk of freezing during this period they should also be drained
of water.
27.If the shower is dismantled during installation or servicing then,
upon completion, an inspection must be made to ensure all
electrical connections are tight and that there are no leaks.
28.This appliance is intended to be permanently connected to the
water mains and not connected by a hose set.
29.The water inlet of this appliance shall not be connected to a water
supply obtained from any other water heating system.
30.Warning! This appliance is not to be used to provide a potable
water supply.
31.Maximum Static Pressure is 1000 kPa (10 bar).
32.Minimum Dynamic Pressure is 100 kPa (1.0 bar) 10.8 kW.
Minimum Dynamic Pressure is 70kPa (0.7 bar) 8.5 kW and 9.5 kW

61341122-W2-C
Pack Contents
Tick the appropriate boxes to familiarise yourself with the part names and to conrm
that the parts are included.
1 x Installation & User Guide
1 x Installation Template
1 x Guarantee Card
Documentation
1 x Electric Shower
1 x Component Pack
1 x Fittings Pack
CH
T
emperature
P
ower
Play

7 1341122-W2-C
Wiring Diagram
HEATER TANK
BLUE C
GREEN B
LED
PUSH BUTTON
SWITCH
MICROSWITCH
(RIGHT)
MICROSWITCH
(LEFT)
SOLENOID
BLUE K
BROWN D
TERMINAL BLOCK
L E N
BROWN M
BROWN D
BLUE N
GRAY J
BLUE K
BLUE N
BROWN A
BROWN A
GREEN B
BLUE C
BROWN M
RED F
RED E
BROWN G
BROWN H
GREY J
BROWN G
BROWN H
RED F
BROWN M

81341122-W2-C
Product Variant Model No. Colour
Mira Play 8.5 kW J10G Mira Play 8.5 kW SAT/CHR
9.5 kW J10H Mira Play 9.5 kW SAT/CHR
10.8 kW J10J Mira Play 10.8 kW SAT/CHR
Design Registration: 003617653-0006
Patents: GB2: 427460; Ireland: 85912
Domestic Light Commercial
Heavy Commercial Healthcare
Introduction
Recommended Usage
Products Covered
Patents and Design Registration
Thank you for choosing a Mira shower. To enjoy the full potential of your new shower,
please take time to read this guide thoroughly, and keep it handy for future reference.
Products manufactured by Kohler Mira Ltd are designed to be safe, provided that
they are installed, used and maintained in good working order, in accordance with
our instructions and recommendations.
Follow all warnings, cautions and instructions contained in this guide, and on, or
inside the shower. This guide is also available in digital format from our website or
by contacting customer services.

9 1341122-W2-C
Specications
Electrical Variant
8.5 9.5 10.8
Nominal Power at 240 V ac 8.5 kW 9.5 kW 10.8 kW
Nominal Power at 230 V ac 7.8 kW 8.7 kW 9.9 kW
Recommended MCB Rating 40 A 40 A 45 A
Max Supply Cable Size 16 mm²
Recommended RCD Rating 30 mA tripping current
Recommended Isolator Switch 45 A double-pole with 3 mm contact separation
Appliance Sealing Rating IP X4 - Suitable for installation in Zone 1
Max Ambient Temperature 30°C
Min Ambient Temperature 2°C
Plumbing Variant
8.5 9.5 10.8
Min Dynamic Pressure 70 kPa (0.7 bar) 100 kPa (1.0 bar)
Max Dynamic Pressure 500 kPa (5.0 bar)
Max Static Pressure 1000 kPa (10 bar)
Min Static Pressure 50 kPa (0.5 bar)
Max Inlet Temperature 30°C
Min Inlet Temperature 2°C
Inlet Connection 15 mm Compression / Pusht Coupling
Max Water Hardness 200 ppm CaCO3
Outlet Connection 1/2” BSP Male
Dimensions
Height 348 mm
Width 224 mm
Depth 101 mm

101341122-W2-C
For domestic installations, Mira Showers guarantee the Mira product against
any defect in materials or workmanship for a period of two years from the date of
purchase (shower ttings for one year).
For non-domestic installations, Mira Showers guarantee the Mira product against any
defect in materials or workmanship for a period of one year from the date of purchase.
For Terms and Conditions refer to the back cover of this guide.
Guarantee
European Conformity Information
This range of electric showers complies with the following European directives:
2014/35/EU - Low Voltage Directive (LVD),
2014/30/EU - Electromagnetic Compatibility Directive (EMC),
2011/65/EU - Restriction of Hazardous Substances Directive (RoHS)
This range of electric showers are high power appliances and are subject to
conditional connection. If the main electrical supply fuse is rated less than 80 Amps,
the local electricity supply company must be contacted to conrm if the electrical
supply is adequate.
This range of showers complies with the requirements of the UK’s water regulations.
Disposal and Recycling
End of Product Life
Electrical and electronic devices contain a range of materials that can be separated
for recycling and used in new products.
This product should not be disposed of with your general household
waste. When this product has reached the end of its serviceable life,
please remove any batteries and take it to a recognised WEEE (Waste
Electrical and Electronic Equipment) collection facility such as your local
civic amenity site for recycling.
Your local authority or retailer will be able to advise you of your nearest recycling
facility.

11 1341122-W2-C
1. The plumbing installation must comply with all national or local water regulations
and all relevant building regulations, or any particular regulation or practice
specied by the local water supply company.
2. DO NOT use sealing compounds on any pipe tting or joints.
3. DO NOT install the product in a position in which service access is limited.
4. Decide on a suitable position for the shower (minimum distance of 200 mm from
the ceiling to allow for cover t and removal).
5. The shower is suitable for installation within the shower area and is tted with a
pressure relief valve. It must be positioned over a water catchment area with the
controls at a convenient height for the user.
6. The shower must be tted to a waterproof at and even wall surface.
7. DO NOT t the shower to the wall and tile up to the case.
8. DO NOT seal the gap between the shower and the wall surface.
9. The showerhead should be positioned so that it discharges down the centre line
of the bath or across the opening of a shower cubicle.
10.The showerhead must be directed away from the shower unit, during normal use
the showerhead must not spray directly on to the shower unit.
11. DO NOT apply excessive force to plumbing connections; always provide
mechanical support when making plumbing connections. Any soldered joints
should be made before connecting the shower.
12.This shower is not designed to be plumbed directly from the rear. For rear-entry
supply, add an elbow to the supply pipe and connect as a rising or a falling supply.
13.If pipework and/or electrical cables enter the shower from the rear through a hole
in the wall provision must be made to prevent water ingress back into the wall
structure.
14.This shower is intended to be permanently connected to the mains water supply,
only use the inlet connection supplied with the shower.
DO NOT use any other type of tting.
15. A full bore/non restrictive servicing valve must be tted in a readily accessible
position adjacent to the shower to facilitate maintenance of the shower. DO NOT
use a valve with a loose washer plate (jumper) as this can lead to a build up of
static pressure.
16.A water treatment device should be installed where the water hardness may
exceed 200 ppm. Malfunctions caused by excessive limescale formation are not
covered by this shower’s guarantee (see back page for details).
17.The installation must not cause the hose to be sharply kinked during normal use.
18.DO NOT perform the electrical installation until the plumbing has been completed
and checked for leaks.
Plumbing
Installation Requirements

121341122-W2-C
Zone of
Backflow Risk
30 mm
Minimum
Toilet or
Bidet FC5
Hand
Basin FC3
Bath or Shower
Tray FC3
Electric
Shower
25 mm
Minimum
25 mm Minimum
Hose retaining ring tted and shower ttings xed at a suitable height
preventing dirty water backow
19. The position of the shower and shower ttings must provide a minimum gap of 25
mm between the showerhead and the spill over level of any bath, shower tray or
basin and a minimum gap of 30 mm between the showerhead and the spill over
level of any toilet, bidet or other appliance with a Fluid Category 5 backow risk.
Note: There will be occasions when the hose retaining ring will not provide
a suitable solution for Fluid Category 3 installations, in these instances
an outlet double check valve must be tted, this will increase the required
supply pressure typically by 10kPa (0.1 bar). Double check valves tted in
the inlet supply to the appliance cause a pressure build up, which aect
the maximum static inlet pressure for the appliance and must not be tted.
For Fluid category 5 double check valves are not suitable.

13 1341122-W2-C
Electrical
1. The electrical installation must comply with BS 7671 (commonly referred to as
the IEE Wiring Regulations) and all relevant building regulations, or any particular
regulation or practice specied by the local electricity supply company.
2. Ensure that all circuit protection devices, switches and cabling is adequate for the
rated current of the shower and that the rating of the electricity supply company
fuse and the consumer unit are adequate for the additional demand.
3. The shower must be earthed. Ensure any supplementary bonding complies with
the relevant regulations.
4. This shower is intended to be permanently connected to the xed electrical wiring
of the mains system. A separate supply must be provided from the consumer
unit to the shower.
5. DO NOT supply any other electrical equipment including extractor fans or pumps
via this product.
6. This shower must be provided with means for local disconnection that is
incorporated into the xed wiring in accordance with the relevant local wiring
regulations. This must be a double pole switch, which has at least 3 mm contact
separation in each pole. The switch can be a ceiling mounted pull-cord type within
the shower room or a wall mounted switch tted in the applicable zone area.
7. For new installations a 30mA Residual Current Device (RCD) must be
incorporated into the electrical supply to this shower in accordance with current
wiring regulations. When replacing an existing electric shower we recommend
that a 30mA RCD be incorporated in accordance with current wiring regulations
if not already provided
8. DO NOT apply excessive force to the terminal block.
9. All electrical connections should be checked for tightness to prevent overheating
before switching on the electrical supply.
10.DO NOT switch on the electrical supply until the plumbing has been completed
and checked for leaks.
Plumbing and Electrical Schematic

141341122-W2-C
Warning, isolate
the electrical and
water supplies
before installing
the shower!
Decide on a suitable position for the shower unit and ttings leaving adequate
space for maintenance. A suitable position for the shower will have a minimum clear
distance of 200 mm from the ceilling. See “Installation Requirements - Plumbing”
for further details.
CH
Temperature
Power
CH
Temperature
Power
DO NOT drill through the shower unit into the wall.
DO NOT drill into buried cables or pipes.
Make sure that you use the installation template (supplied).
Installation

15 1341122-W2-C
CH
Temperature
Power
Remove the cover screws.
CH
Temperature
Power
Remove the cover, the service tunnel and the bungs.
Determine the direction and route of
the incoming water supply as shown.
Note! - DO NOT use an incoming
supply entering the shower directly
from the back. Add an elbow to the
supply pipe and connect it as a rising
or falling supply.
1 Min
DO NOT flush through the product by
removing the inlet filter. Debris may
damage the product and invalidate the
guarantee.
Flush for approximately 1 minute through
pipework prior to connection.
1 2
3 4
Screws
Bungs
Screw Service
Tunnel
Cover
Falling
(entering the
shower from
the top).
Rising
(entering the
shower from
the bottom).

161341122-W2-C
Use template provided to mark and drill required xing holes. Do not drill through
the shower unit into the wall. Plaster and brick dust will damage internal components
of product.
Secure the shower to the wall with all the xing screws and wall plugs (supplied)
or appropriate wall xings (non-corrosive) for your installation.
5
6
Place a spirit level on this
line to level the product
before drilling
Important! Read in conjunction with the
Installation and User Guide
Do not drill into buried cables or pipes
Do not drill through the case and into the wall
as dust can cause product failure
Thoroughly ush the pipework before
connecting to the product
Do not perform any unspecied modications,
or drill or cut holes in the product other than
instructed
Use the correct supply cable size BS 7671
Do not use alternative screws to secure the
cover
Do not silicone seal around the product
Do not install where the product or pipework
may become frozen
Telephone: 0844 571 5000
Fax: 01242 282 595
www.mirashowers.co.uk/contact us
Outlet
Connector
107 mm
1339847-W7-A Kohler Mira Limited, January 2018
This Installation Template is compatible
with the following Mira Electric Showers:
Mira Meta, Mira Play and Mira Corus
Determine the direction and route of the
incoming water supply as shown.
Note! - DO NOT use an incoming supply
entering the shower directly from the
back. Add an elbow to the supply pipe
and connect it as a rising or falling
supply.
Falling
(entering the
shower from
the top).
Rising
(entering the
shower from
the bottom).
Electrical
Connections
Inlet
Connector
Main Fixing
Hole
Main Fixing
Hole
Main Fixing
Hole Alternative
Fixing Hole
Top Clearance
200 mm Min
Clearance
105 mm Min

17 1341122-W2-C
Connect the inlet supply pipe to the inlet
connector using a push t elbow or an
elbow with compression nuts and olives.
Turn the water supply ON and check the
shower unit for leaks.
Strip back sucient outer cable insulation
to enable routing to terminal block.
Insert the wires into the terminal block.
Ensure the earth bonding complies with
the relevant regulations.
Tighten the screws in the terminal block,
make sure the wires are secure and tight.
Important! DO NOT use push t elbows
that require specialist tools for removal.
Access to the inlet filter is required
periodically and so any connector needs
to easily removed for maintenance.
Check the inlet lter is in position before
connecting the inlet supply.
Note! When making connections to
the shower do not use jointing paste
products as damage to the shower will
occur.
L (Live) = Brown wire
(Protective Earth) = Green wire
N (Neutral) = Blue wire
7
8
Pushfit
Elbow
Inlet
Connector
Inlet Filter
Inlet
Supply

181341122-W2-C
CH
Temperature
Power
For falling or rising supplies the cover has
thinned sections on the top and bottom
that can be removed to allow entry of the
supply pipe and electrical cables. Note!
DO NOT extend beyond thinned section.
Ret the service tunnel.
Make sure that the control dials are
aligned with the spindles and replace
the cover.
Tighten the three cover screws.
Warning! Do not use alternative screws
to secure the cover. This can cause
internal damage to the appliance. Do not
seal around the back of appliance.
910
11
CH
Temperature
Power
Install the shower ttings Refer to the
separate Shower Fittings Installation
and User Guide. Note! The shower must
be commissioned before use. Refer to
COMMISSIONING.
12
Thinned
Section

19 1341122-W2-C
1
Make sure that temperature control is in
the full cold position. Turn the power control to low as shown.
2
34
Switch on the electrical supply.
Push the START/STOP button to turn
ON the appliance.
56
COLD
0 - 15 secs
HOT
Water flows freely within a few seconds,
temperature remains cool. Turn power control to Medium as shown.
78
5 - 10 secs
COLD
HOT
Temperature will rise slightly. Turn power control to High as shown.
Commissioning

201341122-W2-C
Push the START/STOP button to turn OFF
appliance.
9 10
5 - 10 secs
COLD
HOT
Temperature will rise further. Adjust temperature as required.
Note! Flow rate will reduce when
temperature setting is increased.
Note! A slight hissing sound may be heard
from the shower during operation. High
mains water pressure and high shower
temperatures will affect the tone. This is
quite normal in use.
11 12
Switch off the electrical supply.
13
A small amount of water may continue
to drain over a few minutes. Wait for the
product to fully shut down. (This may take
few seconds)
Table of contents
Other Kohler Mira Bathroom Fixture manuals
Popular Bathroom Fixture manuals by other brands

Tres
Tres RETRO manual

Delabie
Delabie SPORTING Installation

Hans Grohe
Hans Grohe Axor Massaud 18112000 Instructions for use/assembly instructions

Durovin Bathrooms
Durovin Bathrooms Ravenna 56 L Shape manual

Athena BATHROOMS
Athena BATHROOMS Fleet Vanity installation instructions

Grohe
Grohe TECTRON 37 421 Assembly instruction

KEUCO
KEUCO 59556 000171 installation instructions

BELLOSTA
BELLOSTA Edward Lever 0805/3/L Installation instruction

Kohler
Kohler K-704517 Homeowner's guide

DURAVIT
DURAVIT Tulum TU1010 0010 Instructions for mounting and use

Hans Grohe
Hans Grohe Raindance E Showerpipe 27149000 Instructions for use/assembly instructions

Glacier bay
Glacier bay 3073-141-WS Use and care guide