Kolibri KCS-2000 User manual

KCS-2000
Kolibri KCS-2000 Coin Counter & Sorter
USER MANUAL

H
Important Safety Notes:
When using this product, basic safety precautions should always be followed, including
the following:
• Do not use this unit in areas where it may be exposed to water or any other liquids.
• Only use the power cord supplied with the machine. Plug the power cord into a
properly grounded wall outlet. Do not remove the ground pin from the power cord.
Failure to properly ground the machine can result in severe injury or re.
• Make certain the unit is installed on a at surface. Do not operate the machine in
areas with high temperature, humidity or smoke as these conditions may prevent
proper operation.
• Do not start the unit when the rear access panel is open. Ensure no coins are in the
hopper when the machine is rst turned on.
• When not using the unit for an extended period of time, disconnect the power cord
from the wall outlet.
• Unplug the unit from the wall outlet before cleaning. Use a damp cloth or accessories
such as an air duster or soft bristle brush.
• To avoid the risk of electrical shock, do not disassemble this unit. Disassembly will
expose you to dangerous voltages and other safety risks. Incorrect reassembly can
cause an electrical shock when the appliance is subsequently used.
• Take the unit to a qualied technician when service or repair is required. Do not try to
replace any parts yourself.
This manual contains important information on safety measures and
operational features of the KCS-2000 coin counter and sorter. Please
read it carefully before operating your machine and keep it for future
reference.
While every effort has been made to include all features into this user
manual, specications stated may not reect all the features of the later
software versions.
If you have questions about your KCS-2000 and its operation, please
contact technical support at www.kolibriusa.com/contact/.
CHOKING HAZARD.
SMALL PARTS.
Not for children under
3 years old.
DO NOT DISPOSE
IN TRASH. Follow
appropriate local electronics
scrap procedures.
WARNING: RISK OF
ELECTRICAL SHOCK. This
equipment is to be serviced by
trained personnel only.
WARNING: HAZARDOUS
MOVING PARTS. Do not
place fingers, hair, clothes,
lanyard... near moving parts.
PROP 65 WARNING. This product may contain chemicals known to the State
of California to cause cancer, or birth defects or other reproductive harm.
https://oehha.ca.gov/

Table of Contents
1. INTRODUCTION
1.1 About the Kolibri KCS-2000 _____________________________________________________ 2
1.2 Box Contents __________________________________________________________________ 2
1.3 Specications__________________________________________________________________ 3
1.4 Front and Rear Views___________________________________________________________ 4
1.5 Control Panel __________________________________________________________________ 5
2. GETTING STARTED
2.1 Powering Up ___________________________________________________________________ 6
2.2 Counting_______________________________________________________________________ 6
2.3 Adding_________________________________________________________________________ 7
2.4 Setting Batch Quantities________________________________________________________ 7
2.5 Clearing Batch Quantities_______________________________________________________ 9
2.6 Wrapping Coins _______________________________________________________________ 10
3. MAINTENANCE, TROUBLESHOOTING, WARRANTY, CONTACT INFORMATION
3.1 Maintenance__________________________________________________________________ 13
3.2 Troubleshooting ______________________________________________________________ 15
3.3 Warranty______________________________________________________________________ 16
3.4 Contact Information___________________________________________________________ 17
INTRODUCTION
1.
1.1 About the KCS-2000
Thank you for choosing the KCS-2000 Coin Sorter.
The KCS-2000 is a multi-functional coin processing machine which incorporates
all the features of a professional coin counter/sorter/wrapper at an affordable
price. Its large hopper is capable of holding 2,000 coins and the coin trays can
each accumulate up to 900 coins at a time. Displaying the subtotal for each
denomination and the total value make the KCS-2000 an easy all-in-one tool for
any coin handling needs. The KCS-2000 lightweight, compact, and stylish design
will easily t into your business environment.
1.2 Box Contents
1. KCS-2000 Automatic Coin Counter Sorter and Wrapper
2. User Manual
3. Cleaning Cloth
4. Coin Trays
5. Coin Tubes
1 2

1. Control Panel
2. Coin Hopper
3. Coin Trays
4. Plastic Housing
5. Carrying Handle
6. Rear Access Panel
7. Power switch
Denomination USD model
$1 130
25¢ 350
10¢ 900
5¢ 450
1¢ 300
1.4 Front and Rear Views
1.3 Specications
Hopper capacity: Up to 2,000 coins (varies for each currency)
Coin Tray capacities:
Batch range: 0-500 coins
Display: 7 digit LED
Dimensions: 11.18’’ x 10.24’’ x 10.83’’ (284 x 260 x 275 mm)
Weight: 8.7 lbs (3.95 kg)
Counting speed: Up to 300 coins/min
Input power: 110 VAC / 60 Hz or 220 VAC / 50Hz
(refer to input power label on the rear of this unit)
Power consumption: 45 watts maximum
Ambient temperature: 0ºC - 40ºC (32ºF - 104ºF)
Ambient humidity : 30 to 80%
3 4
1
3
2
46
5
7

1.5 Control Panel
Name Function
BAT Selects preset batch quantities
(0, 10, 20, 25, 50, 80, 100, 120, 150, 200, 300, 400, 500)
SET Shows batch quantities set for each denomination. Also
used to set batch quantities for coin trays when pressed
for 3 seconds
+ (Plus) Increases batch quantity by a value of 1
Switches between value reporting and quantity reporting
Also used to set batch quantities for coin rolls when
pressed for 3 seconds
- (Minus) Decreases batch quantity by a value of 1
Also used to clear all batch quantities when pressed for
3 seconds
REPORT Shows value (or quantity) of coins counted for each
denomination
C Clears the display and resets the count
START/STOP Starts or stops operation of the machine
6
GETTING STARTED
2.
2.1 Powering Up
IMPORTANT: Before turning on KCS-2000, make certain no coins are present in the
coin hopper. This will cause an “EA” error when the KCS-2000 self-test is
performed. To clear the “EA” error, press the “START/STOP” button, then
empty any coins present in the coin trays
Plug the power cord attached to the KCS-2000 into a three-prong outlet. Turn on the
power switch located on the rear of the unit. The machine will conduct a self-check. The
main display will show “0” when the test has successfully completed
2.2 Counting
The KCS-2000 always operates in a batching mode by default. To enable simple
counting, all batch quantities need to be set to zero. To set batch quantities to zero,
press and hold the “-” button for approximately three seconds until “C” is displayed on
the left of the LED display.
• Before loading the hopper, make sure there are no uncounted coins remaining in it
from the previous count.
• To count coins, place them into the hopper and press the “START/STOP” button.
• The KCS-2000 will start counting and will automatically sort all coins into the
appropriate coin trays.
• The machine will automatically stop when all coins in the hopper are counted, or if the
batch quantity for any coin denomination is reached.
• To stop the machine, press the “START/STOP” button.
• To resume counting, press the “START/STOP” button.
• When a coin tray becomes full, stop the machine and empty the tray to ensure correct
machine operation. Stopping the machine will not alter or reset the count. You can
continue counting by pressing the “START/STOP” button.
• As it counts, the KCS-2000 will automatically display the total value of counted coins
on the screen.
5

• To view the value of coins counted for each denomination press the “REPORT” button.
The denomination will appear on the left and value of coins counted on the right part of
the screen. To display the number of coins counted, press the “+” button.
While in the report mode, pressing the “+” button will switch the display between value of
coins counted or number of coins counted. The KCS-2000 will remember the last setting
chosen for the report display.
• To reset the coin count before starting a new batch, press the “C” button
2.3 Adding
The KCS-2000 operates in ADD mode by default. In ADD mode, the coin count is added
to the count from previous batches. To start a new count, press the “C” button. This will
reset the coin count to zero.
2.4 Setting Batch Quantities
You may batch the desired quantity of each coin denomination. Each denomination can
be assigned a batch quantity.
1. Setting batch quantities for coin rolls
• Press and hold the “+” button for approximately three seconds until “L” is shown in
the display. This automatically programs each coin denomination for bank coin roll
amounts as follows:
7
Denomination Quantity
$1 25
25¢ 40
10¢ 50
5¢ 40
1¢ 50
Denomination Quantity
$1 100
25¢ 350
10¢ 900
5¢ 450
1¢ 300
2. Setting batch quantities for coin trays
• Press and hold the “SET” button for approximately three seconds until “H” is shown
in the display. This automatically programs each coin denomination for coin tray
amounts as follows:
3. Setting other batch quantities
• Press the “SET” until the desired denomination appears on the left part of the screen.
• To assign a batch quantity for this denomination press the “BAT” button until a desired
batch quantity appears on the display
• (0, 10, 20, 25, 50, 80, 100, 120, 150, 200, 300, 400, 500). Fine adjustments to batch
quantity can be made by pressing “-“ or “+” button.
• Repeat this procedure to set the desired batch quantities for other
coin denominations.
8


11
To use the coin tube attachments, perform the following steps:
1. Remove the coin tray(s) for the denomination coins that will be using coin tubes.
2. Insert the appropriate preformed paper wrapper completely into the tube with the
crimped side on the bottom.
3. Ensure that the wrapper shape is round, and the upper tip is not bent over so coins
can easily fall into the tubes.
4. Secure the coin tubes to the KCS-2000 by gently sliding each tube into the proper slot
in the base of the machine.
5. Set coin roll batch quantities (see section 2.4) for each coin denomination by
pressing and holding the “+” button for approximately three seconds until “L” is
shown in the display. This programs each coin denomination for standard bank
coin roll sizes.
6. Load coins into the coin hopper and press the “START/STOP” button. The KCS-2000
will automatically dispense the correct number of coins into each coin tube.
7. When the number of dispensed coins equals the batch quantity for any
denomination, the KCS-2000 will stop and display a message on the control panel.
For example, after the rst batch of 50 pennies has been counted, the front panel
will display:
1c50 (quantity reporting)
or
1c0.50 (value reporting)
Note: When operating in batch mode, the KCS-2000 will keep a running total for each
denomination coin. For example, after four batches of 50 pennies have been dispensed,
the KCS-2000 will stop and display:
1c200 (quantity reporting)
or
1c2.00 (value reporting)
8. Remove the full coin tube from the KCS-2000 and slide out the paper wrapper
containing the coins. Crimp the open end of the wrapper. Insert and empty wrapper in
the coin tube and reinstall the coin tube.
9. Press the “START/STOP” button to continue batching.
12
3. Attach the coin tubes to the KCS-2000 by gently sliding each tube into the proper slot
in the base of the machine as shown in Figures 2 and 3.
Figure 2 - Installing coin tube Figure 3 - Coin tube in proper position
Figure 4 - US model
Figure 5 - Canadian model
Coin tube locations for each country varies. Use coin denomination labels to help
you place the coin tubes. Coin tubes should be placed exactly underneath the coin
denomination label.
(Set up for other countries may vary)
8
7
43
2
5
6
8
1
743
2
5
6

13
MAINTENANCE AND TROUBLESHOOTING
3.
3.1 Maintenance
ATTENTION: Always power off unit and disconnect from power source
before cleaning.
Most operational problems can be avoided by regular care and preventative
maintenance. Taking regular care of the KCS-2000 will signicantly increase its
lifetime.
To get the best results out of your machine, the following maintenance is
recommended on a regular basis:
1. Clean all external parts of the machine with an air duster or a soft cloth. Do
not use solvents, as they may damage the KCS-2000.
2. Remove the three housing screws and carefully lift up the housing.
3. Remove any foreign objects from the distribution plate.
4. Vacuum or use the air duster to clean the dust left in the
distribution plate.
5. Clean all sensors using an air duster followed by a microber cloth lightly
moistened with isopropyl alcohol.
A. Running sensor
B. Counting sensors
14
Clean all sensors and other dusty parts using compressed air or a soft bristle brush
running sensor counting sensor
Sensor locations
E1
E2
E3
E4
E5
E8
E7
E6

15
3.2 Troubleshooting
Error message display:
Error Message Cause Solution
E 1 - E8 A counting sensor may have
collected dust or is obscured by a
foreign object.
Clean the counting sensor using
an air duster and cleaning swab
(refer to section 3.1). Inspect
coin outlet openings for possible
foreign material that may be
present (rubber bands, paper, etc.)
E9 Running sensor does not detect
the rotation of the coin platter.
Clean the running sensor (refer to
section 3.1).Inspect the interior of
the machine for possible foreign
material that may be preventing
the coin platter from rotating.
EA 1. Coins present in the hopper
when the machine is turned on or
defective coin sensor
1. Press the “START/STOP” button
to clear the error. Empty any coins
in coin trays back into the hopper.
If the error persists, contact Kolibri Technical Service Center (refer to section 3.3).
Other possible errors:
Problem description Cause/Action
Does not function after the unit has
been turned on.
Ensure the power cord is connected properly.
Unplug the machine from any power source and
replace the fuse (F2AL250V) located on the bottom
of the machine.
Inaccurate counting Clean counting sensors using an air duster or
microber cloth. Refer to section 3.1.
Coins are jammed. Turn off the machine. Remove the three housing
screws and carefully lift up the housing. Refer to
section 3.1.
Remove any foreign objects or coins from the
distribution plate. Refer to section 3.1.
Turn the unit on and restart counting.
If the error persists, contact Kolibri Technical Service Center (refer to section 3.4).
16
3.3 Warranty
The KCS-2000 is warranted for a period of one year from the date of purchase. In most cases
a unit malfunction can easily be corrected by performing a thorough cleaning.
• Customer should allow the manufacturer the time and opportunity to test and diagnose the
machine to determine warranty and non-warranty claims
• After receiving and unpacking the unit, customer shall keep the package and its user
manual. Warranties are canceled in the event the device is transported in a non-original
packaging or operation/maintenance conditions are not mett
• Company is not responsible for unit malfunction due to improper maintenance, storage, or
transportation including, but not limited to mechanical damage
• Manufacturer is entitled to introduce updated software, not described in the current
user manual
Non-Warranty Service:
The manufacturer can perform maintenance and cleaning for an extra fee. For a
non-warranty repair or maintenance quotation, contact our Technical Support team.
Warranty service is not available in the following cases:
• Cleaning of the unit from dust and mud
• Operation or maintenance rules requirements set in the user manual are not met
• There is mechanical damage to the unit or the sealed portions of the unit have been opened
or tampered with
• There are foreign objects or liquid inside the unit
The warranty does not cover shipping to Kolibri’s technical service center.

17
3.4 Contact Information
Technical Support contact information:
email: [email protected]
phone: (877) 930 9289
If you need to contact Kolibri Technical Service Center, please have the following
information with you:
• Product Model: Located on the back side of the machine
• Serial Number: Located on the bottom of the machine
• Nature of the problem: What happened, and when did it happen? Did the machine display
an error message?
• Steps Taken: Steps already taken to resolve the problem, and the results. (if any)
Kolibri
©2019 Printed in China.
Specications subject to change without notice.
www.KolibriUSA.com
FNKCD2000102019
Table of contents
Popular Cash Counter & Coin Sorter manuals by other brands

Peradon
Peradon DCT Conversion instructions

Beckmann
Beckmann EMS-58 operating manual

PRO Intellect Technology
PRO Intellect Technology PRO CS-80E user manual

Coinco
Coinco Guardian GLX Series Installation & operation guide

Pecunia
Pecunia M3 Operation manual

Royal Sovereign
Royal Sovereign Quick-Sort CO-1000 instruction manual