Installation and Maintenance Service Manual
A. Outdoor intake
B. Supply air
C. Extract indoor
D. Exhaust air
E. Kitchen hood connection (by-pass – extraction without heat recovery)
F. Bathroom connection (by-pass – extraction with out heat recovery)
E
F
3 Picture
We reserve the right to make changes without prior notice.
Brief Description of the Unit
• Casings of air handling units are made of galvanized steel sheets, which are powder painted. Mineral wool is used
for thermal insulation and sound attenuation. Unit cover panels are 15...20 mm thick. The air handling unit is in-
tended for ventilation of small-sized spaces (eg. single family houses, ats). The unit is designed to be mounted on
kitchen hood. As standard, the unit is designed for indoor placement. The operating temperature range for the unit
is -300C ... 400C, outdoor air temperature.
The air handling unit is not to be used to transport solid particles, even not in areas where there is a risk of
explosive gases.
• KOMFOVENT DOMEKT REGO 200VE(W) is equipped with a rotary heat exchanger, air lters, an electric air
heater, fans and automation control system, to ensure safe and efcient operation of the unit.
• Before you open the door, the unit must be switched off and the fans must have been given time to stop (up to 3
minutes).
• The unit contains heating elements that must not be touched when they are hot.
• To maintain a good indoor climate, comply with regulations and, to avoid condensation damage, the unit must never
be stopped apart from during service/maintenance or in connection with an accident.
• If the unit is placed in spaces with high humidity, condensation might occur on the surface of the unit when outdoor
temperatures are very low.
DOMEKT REGO 200VE(W) B(K) Air Handling Unit Schemes
1. Rotary heat exchanger
2. Supply air lter
3. Exhaust air lter
4. Supply fan
5. Exhaust fan
6. Electric air heater*
7. Automation control system
* AHU REGO-200VW-B is suitable for use with water duct air heater.