Koolance ALX Series User manual

Superior Liquid Cooling Systems
®
English v1.0
ALX Series Products
User’s Manual
ALX Series Products
User’s Manual

A newer version of this User Manual may exist. Please be sure to check our support page
for the latest version of this guide: www.koolance.com
GENERAL PRECAUTION
Please read this manual carefully before beginning the installation of your Koolance
system.
PROHIBITED USE
This product is designed, developed and manufactured as contemplated for general use,
designed, developed and manufactured as contemplated for use accompanying fatal risks or
dangers that, unless extremely high safety is secured, could lead directly to death, personal
injury, severe physical damage or other loss, including without limitation: nuclear power core
or weapon launching control. If these products are used in such hazardous environments,
Koolance Incorporated does not warrant them.
TRADEMARKS
The Koolance name and logo are trademarks or registered trademarks of Koolance, Inc.
only and may be trademarks or registered trademarks of their respective companies.
COPYRIGHT
All rights reserved. Copyright (C) Koolance Incorporated.
!WARNING:Indicates a potentially hazardous situation which, if not avoided,
could result in personal injury or be life-threatening.
!CAUTION:Indicates a potentially hazardous situation which, if not avoided,
may result in damage to equipment or property.
PROHIBITED:Indicates a prohibited action.
ABOUT SIGNS
Throughout this document, critical information is highlighted in gray-colored boxes. The
following symbols are intended to help prevent any situation which may cause personal
injury and/or damage to equipment:
1
Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Table of Contents
Product Diagram ............................................................................................. 3
Positioning the System ................................................................................... 4
Combining Modules ........................................................................................ 4
Wiring.............................................................................................................. 6
Tube Fittings ................................................................................................... 7
Coolant Filling and Powering-On .................................................................... 8
Display Panel .................................................................................................. 9
Temp Set....................................................................................................... 10
Alarm Set ...................................................................................................... 10
Relay Set ...................................................................................................... 11
Pump Set ...................................................................................................... 11
Display Set.................................................................................................... 11
Software Feature .......................................................................................... 12
Troubleshooting ............................................................................................ 13
WARNING: The Koolance liquid coolant contains chemicals which may
be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS
CHEMICALS OUT OF THE REACH OF CHILDREN. Please refer to
the coolant MSDS available on our website: www.koolance.com
!
CAUTION: Supply only the proper input voltage and polarity to the
cooling system, as labeled below the terminals on the unit. Improper
power can damage the unit and is not covered under the warranty.
!
KOOLANCE CONTACT INFORMATION
Koolance Inc. (USA)
Address: 2840 W. Valley Hwy. N., Ste. 101, Auburn, WA 98001, USA
Telephone: +01 253-249-7669
2

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Product Diagram
Radiator Fans
Display
Panel
Power Terminals
Reservoir Fill Port
ALX systems are composed of two modules physically connected together: the
front “RPM” and rear “HXM”. Diagrams below are general representations, as
RPM Reservoir and Pump Module
Coolant Reservoir
Control Buttons
Main Power
Switch
HXM Heat Exchanger Module
Radiator
(Internal)
3

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Positioning the System
Combining Modules
If you have purchased both RPM and HXM modules, they are combined together
using hardware included with those products.
This product must be operated in an upright orientation (shown below). Alternative
orientations can prevent the coolant pump from operating properly.
RPM module onto its rear inlet and outlet.
is a parallel thread, do not use plumber’s
tape.)
the HXM module onto its *front* inlet and
(This is a parallel thread, do not use
plumber’s tape.)
Fittings on Rear of RPM
Fittings on Front of HXM
4

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Fasten the included mounting
bracket to the rear of the RPM
module using four bracket
screws.
The bracket must match the
orientation shown to the right.
Finish combining modules by securing
the bracket with its remaining four
screws.
Two screws are installed into
corresponding holes on each side of
the HXM module.
5

There are several available wire terminals near
the reservoir window of the RPM module:
1. Two K-Type Thermocouples (not included)
2. Relay Output NO/NC (normally open or closed)
3. USB for Data Logging (Type B Plug)
4. HXM Module, Fan & Flow Meter ribbon cable
5. Connect power leads to the red positive “+” and
black negative “-” power terminals, as labeled on
the side of the unit.
Connect the included ribbon cable
between RPM and HXM “HX Module”
plugs. For the data logging feature,
attach the included USB cable.
There is a cable guide beneath the
reservoir to hide some of the wiring.
The ALX cooling system requires a 12VDC power supply (not included). Amperage
for RPM and HXM modules are printed separately on their labels. These can be
added together for the total power requirement and range between 2-8A.
CAUTION: Supply only the proper input voltage and polarity to the
cooling system, as labeled below the terminals on the unit. Improper
power can damage the unit and is not covered under the warranty.
!
Wiring
1
2
3
4
5
For a cleaner appearance, the power and
USB cables can be routed beneath the
HXM module towards the back.
Zip ties are included to secure them to the
radiator grill (use needle-nose pliers).
6
Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Cut tubing into two segments. You
will need to connect each to the rear
Each tubing connection will use a threaded compression
ring or tube clamp to keep it secure. Be sure to thread
the compression ring or tube clamp onto the tubing
before attaching it.
dipping the end of the tubing in water.
Tighten the connection by sliding the compression
into the proper position before releasing.
tapered 1/4-inch NPT. Plumber’s tape (PTFE) is required to
seal them properly.
Tube Fittings
After wrapping with tape, the inlet and
outlet fittings should be inserted by
the last 1-2 rotations.
7

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Power on the cooling unit, and increase the pump speed to move coolant if
needed. When most of the air has been pushed out of the tubing, the liquid
noise will decrease. This process can take several minutes, depending
During this process, liquid components (or the cooling system itself) may need to
be tilted gently to assist with air evacuation. The reservoir level will decrease during
To
maintain the product warranty, use
only Koolance approved coolant.
Many alternative liquids and additives
can cause permanent damage to the
cooling unit (through chemical reaction,
corrosion, biological growth, high thermal
expansion, viscosity, etc.).
port.
etc.) have been connected with tubing,
the large slot-headed screw with a screwdriver or
large coin.
Coolant Filling and Power-On
WARNING:Most coolants are electrically conductive. Use caution
and power cables. Keep the primary AC supply unplugged whenever
!
Never
An air gap must always remain to ac-
commodate thermal expansion of the liquid.
8

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
• On the main screen, hold ◙for 3 seconds to change display units between
°C/°F and LPM/GPM.
• You can exit any menu and return to the main screen by holding ◙for 2
seconds.
• To reset ALL settings to default, hold ▼ + ▲ for 3 seconds.
Main Menu
◙
Use ▼ and ▲ to navigate this menu.
TEMP/FAN SET : Temperature set-point adjustment
ALARM SET : Alarm settings
RELAY SET : Relay Trigger settings
PUMP SET : Pump speed settings
DISPLAY SET : LED display settings
When in the top menu, press ◙to enter one of the above categories. To exit from
here, press ◄.
External Sensors
This unit has an integrated liquid temperature
sensor in the reservoir. It also provides terminals
for connecting up to two K-type thermocouples (not
included) for external temperature monitoring and
set point options.
Display Panel
The Koolance display panel allows control and monitoring of various aspects of
the cooling unit. 5 buttons are used, with directional arrows to navigate or change
settings, and a center button to select/exit.
Navigate Up,
Increase Setting
Navigate Down,
Decrease Setting
Navigate
Left
Navigate
Right
Enter/Exit
◙
▲
▼
9

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
ALARM SET
which are simultaneously active. Upon entering the alarm menu, the last edited
Press ▼or ▲to adjust this value. Press ◙to accept and return to
the previous menu. To disable an alarm, increase or decrease its setting to “ -- ”.
LIQ TEMP : Liquid Temperature (Range: 0 to 99°C)
CH1 TEMP : Thermocouple #1, if attached (Range: 0 to 99°C)
CH2 TEMP : Thermocouple #2, if attached (Range: 0 to 99°C)
FLOW : Coolant Flow Rate (Range: 0.1 to 10.0LPM)
LEVEL : Low Coolant Level in Reservoir (ON, or OFF to disable)
The regular audio alarm is a repeating beep. If a steady alarm tone is heard, this
indicates the relay has been triggered (see “RELAY SET”).
TEMP/FAN SET
Under “TEMP/FAN SET”, you can select the active set-point temperature the
are four options to select from. Press ▼ and ▲ to scroll among them:
LIQ TEMP : Liquid Temperature (Range: -30 to 90°C)
CH1 TEMP : Thermocouple #1, if attached (Range: -20 to 120°C)
CH2 TEMP : Thermocouple #2, if attached (Range: -20 to 120°C)
FAN PWR : Static fan power setting (Range: 0 to 100%)
The sensor currently displayed in this menu is what the system will follow.
Only one can be active. Press ◙to adjust the target value using ▼and ▲. Below
are some examples:
LIQ TEMP= 32C Maintain coolant coming from the system at 32°C
CH1 TEMP= 50C
CH2 TEMP= -5C Maintain the second thermocouple at -5°C, if attached.
(This is not a sub-ambient system. Without external
assistance, this temperature may not be reached.)
FAN PWR= 45% Keep fans at 45% power, regardless of temperature.
Press ◙
menu.
▲
▼
▲
▼
10

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
RELAY SET
can be connected as normally-open (NO), or normally-
closed (NC), labeled near the terminals.
Press ▼or
▲to adjust this value. Press ◙to accept and return to the previous menu. To
disable the relay, increase or decrease its setting to “ -- ”.
LIQ TEMP : Liquid Temperature (Range: 0 to 99°C)
CH1 TEMP : Thermocouple #1, if attached (Range: 0 to 99°C)
CH2 TEMP : Thermocouple #2, if attached (Range: 0 to 99°C)
FLOW : Coolant Flow Rate (Range: 0.1 to 10.0LPM)
LEVEL : Low Coolant Level in Reservoir (ON, or OFF to disable)
The relay is accompanied by a steady audio alarm tone. If a repeating beep is
heard, this indicates the regular alarm has been triggered (see “ALARM SET”).
PUMP SET
The pump speed can be manually set from 1 (lowest) to 10 (highest):
PUMP(1-10) 7LV : Pump Speed Level
Press ▼or ▲to adjust. Press ◙ to return to the
previous menu.
▲
▼
DISPLAY SET
and how they are shown:
DISPLAY
FIXED CYCLIC
Press ◄or ►to change between these
options. Press ◙or press ▲to exit. If “FIXED”
is selected, two lines will be shown:
FAN SET 50% : First line display option
LIQ TEMP 30.5C : Second line display option
11

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
If “CYCLIC” is chosen from the DISPLAY SET menu, multiple values can be rotated
through the front display.
Use ▼and ▲ to navigate to other lines. Press ◙to enable
or disable each value. This will remove the asterisk, thereby hiding that line from
being shown on the main screen:
*FAN SET : (Field varies) Shows current active set-point or fan power
*LIQ TEMP : Shows reservoir liquid temperature
CH1 TEMP
CH2 TEMP : Shows second external sensor temperature (if connected)
FAN : Shows radiator fan RPM
*PUMP : Shows pump impeller RPM
*FLOW
Press ◄to return to the previous menu, or press ► to exit DISPLAY SET.
▲
▼
▼ or ▲ to change what this line will display:
FAN SET : (Field varies) Shows current active set-point or fan power
LIQ TEMP : Shows reservoir liquid temperature
CH1 TEMP
CH2 TEMP : Shows second external sensor temperature (if connected)
FAN : Shows radiator fan RPM
PUMP : Shows pump impeller RPM
FLOW
Press ◙to move to line 2, and similarly use ▼or ▲to choose what will be
displayed on the second line. Press ◙again to exit.
▲
▼
Software Feature
This unit supports Koolance’s “System Monitor” application for viewing cooling
download the latest version of the program. Consult the application’s readme.txt
for further details.
12

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
We hope your Koolance system will provide you with years of reliable cooling
performance. To help avoid unnecessary RMA issues, we have prepared this list
of possible operational problems, and their most common solutions.
visible signs of liquid movement...
top of the reservoir and temporarily set the pump speed to 10 (see “PUMP
SET”) to help push out the air.
If possible while the pump is running, gently tilt your cold plates or other
components connected to the system in various directions to assist with
doing so.
3. The temperature alarm sounds and I’m not sure why...
whenever an alarm sounds. Check that your currently selected temperature
SET”). If you are certain the cooling system is working properly otherwise, try
resetting all system settings by holding ▼ + ▲ for 3 seconds.
5. The front display is locked up or not responding.
Reset all system settings by holding ▼+ ▲for 3 seconds. After a reset, all con-
Troubleshooting
13

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Limited Warranty
Disclaimer
Koolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled
system (“the system”), against defects in materials or workmanship for a period of
one year from the date of purchase, and agrees to repair or replace any defective
Koolance system without charge. Shipping costs are non-refundable.
This warranty is non-transferable. All warranty claims must be accompanied by the original
proof of purchase.
THIS WARRANTY DOES NOT COVER DAMAGE RESULTING FROM ACCIDENT,
MISUSE OR ABUSE, LACK OF REASONABLE CARE, SHIPPING DAMAGE,
MODIFICATIONS, THE AFFIXING OF ANY ATTACHMENT NOT PROVIDED WITH
THE PRODUCT, LOSS OF PARTS, OR OPERATING COMPONENTS AT SPEEDS OR
FUNCTIONS OTHER THAN THOSE SPECIFIED BY THEIR MANUFACTURERS.
Use of unauthorized replacement parts or liquids will void this warranty. Koolance
Incorporated will not pay for warranty service performed by a non-authorized repair
or diagnostic service and will not reimburse the consumer for damage resulting from
warranty service performed by a non-authorized repair service. No responsibility is
assumed for any special incidental or consequential damages due to a defective Koolance
product.
In order to obtain warranty service, contact our RMA department for information. The
product must be shipped postage prepaid to an authorized Koolance service location. It
is suggested that, for your protection, you return shipments of product by insured mail,
insurance prepaid. Damage occurring during shipment is not covered by this warranty.
Shipping costs are non-refundable. No other warranty, written or oral, is authorized by
Koolance Incorporated.
IN NO EVENT SHALL KOOLANCE INCORPORATED OR ITS EMPLOYEES, AGENTS,
SUPPLIERS, MANUFACTURERS, OR CONTRACTORS BE LIABLE FOR ANY
DAMAGES OF ANY KIND OR CHARACTER, INCLUDING WITHOUT LIMITATION
ANY COMPENSATORY, INCIDENTAL, DIRECT, INDIRECT, SPECIAL, PUNITIVE, OR
CONSEQUENTIAL DAMAGES, LOSS OF USE, LOSS OF DATA, LOSS OF INCOME OR
PROFIT, LOSS OF OR DAMAGE TO PERSONS OR PROPERTY, CLAIMS OF THIRD
PARTIES, OR OTHER LOSSES OF ANY KIND OR CHARACTER, AND WHETHER
OR NOT THE POSSIBILITY OF SUCH LOSS OR DAMAGE HAS BEEN NOTIFIED TO
KOOLANCE INCORPORATED.
14

www.arbel-ltd.com
ISO
9001
Other manuals for ALX Series
1
Table of contents
Popular Air Conditioner manuals by other brands

Retro Aire
Retro Aire R40C Installation, operation & maintenance manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

CLIMAVENETA
CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Toshiba
Toshiba RAS-13SKHP-E Service manual

Daikin
Daikin FTKS50EV1B Operation manual

Fujitsu
Fujitsu General ASHH30KMTB Service manual

Airwell
Airwell AW-CFM012-N11 Service manual

Midea
Midea BREEZELESS Technical manual

Carrier
Carrier ROOM AIR CONDITIONER operating manual

Mitsubishi Electric
Mitsubishi Electric Mr.Slim PEA-M200 installation manual

Bard
Bard THE WALL-MOUNT WA3S3-A installation instructions

Toshiba
Toshiba RAS-10J2KV-HK owner's manual