KUL KU-SAC120W User manual

Split AC
User Manual
Models: KU-SAC120W
KU-SAC180W
KU-SAC220W

CONTENTS
SAFETY PRECAUTIONS
NAMES OF PARTS
INDOOR UNIT DISPLAY
OPERATING INSTRUCTIONS
PROTECTION
INSTALLATION MANUAL
MAINTENANCE
TROUBLESHOOTING
EMERGENCY FUNCTION & AUTO-RESTART FUNCTION
REMOTE CONTROLLER
....................................................................................................1
.................................................................................................................4
.........................................................................................................5
..............................................6
........................................................................................................7
.............................................................................................11
.........................................................................................................................16
....................................................................................................17
....................................................................................................................26
..........................................................................................................27

During the installation of the indoor and
outdoor units the access to the working area
should be forbidden to children.
Unforeseeable accidents could happen.
Make sure that the base of the outdoor unit is
firmly fixed.
Check that air cannot enter the refrigerant
system and check for refrigerant leaks when
moving the air con ditioner.
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
Carry out a test cycle after installing the air
conditioner and record the operating data.
The ratings of the fuse installed in the built
incontrol unit are T 5A / 250V .
The user must protect the indoor unit with a
fuse of suitable capacity for the maximum input
current or with another overload protection
device.
Ensure that the mains voltage corresponds to
that stamped on the rating plate. Keep the switch
or power plug clean. Insert the power plug
correctly and firmly into the socket, thereby
avoiding the risk of electric shock or fire due to
insufficient contact.
Check that the socket is suitable for the plug ,
otherwise have the socket changed.
Do not install the appliance at a distance of
less than 50 cm from inflammable substances
(alcohol, etc.) Or from pressurised containers
(e.g. spray cans).
If the appliance is used in areas without the
possibility of ventilation, precautions must be
taken to prevent any leaks of refrigerant gas
from remaining in the environment and creating
a danger of fire
The packaging materials are recyclable and
should be disposed of in the separate waste
bins .Take the air conditioner at the end of its
useful life to a special waste collection centre
for disposal.
Only use the air conditioner as instructed in
this booklet. These instructions are not intended
to cover every possible condition and situation .
As with any electrical household appliance ,
common sense and caution are therefore always
recommended for installation, operation and
maintenance.
The appliance must be installed in accordance
with applicable national regulations.
Before accessing the terminals , all the power
circuits must be disconnected from the power
supply.
Read this guide before installing and using the
appliance.
1
T
he appliance must be fitted with means for
disconnection from the supply mains having a
contact separation in all poles that provide full
disconnection under overvoltage category III
conditions, and these means must be incorporated
in the fixed wiring in accordance with the wiring
rules.
The appliance shall be installed in accordance
with national wiring regulations.
This appliance can be used by children aaged
from 8 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
shall not play with the appliance. Cleaning and
user maintenance shall not be made by
children without supervision.
The air conditioner must be installed by
professional or qualified persons.

SAFETY RULES AND RECOMMENDATIONS FOR THE USER
Do not try to install the conditioner alone;
always contact specialized technical personnel.
Cleaning and maintenance must be carried out
by specialised technical personnel. In any case
disconnect the appliance from the mains
electricity supply before carrying out any
cleaning or maintenance.
Ensure that the mains voltage corresponds to
that stamped on the rating plate. Keep the switch
or power plug clean. Insert the power plug
correctly and firmly into the socket , thereby
avoiding the risk of electric shock or fire due
to insufficient contact.
Do not pull out the plug to switch off the
appliance when it is in operation, since this
could create a spark and cause a fire, etc.
If the appliance gives off smoke or there is a
smell of burning, immediately cut off the pow
er supply and contact the Service Centre.
Have repairs carried out only by an authorised
Service Centre of the manufacturer . Incorrect
repair could expose the user to the risk of
electric shock, etc.
The prolonged use of the device in such
conditions could cause fire or electrocution.
Never remain directly exposed to the flow of
cold air for a long time. The direct and prolonged
exposition to cold air could be dangerous for your
health .Particular care should be taken in the
rooms where there are children , old or sick
people.
This appliance has been made for air
conditioning domestic environments and must
not be used for any other purpose , such as for
drying clothes, cooling food, etc.
The packaging materials are recyclable and
should be disposed of in the sparate waste
bins . Take the air conditioner at the end of its
useful life to a special waste collection centre
for disposal.
Only use the air conditioner as instructed in
this booklet.These instructions are not int ended
to cover every possible condition and situation.
As with any electrical household appliance,
common sense and caution are therefore always
recommended for installation , operation and
maintenance.
Always use the appliance with the air filter
mounted . The use of the conditioner without
air filter could cause an excessive accumulation
of dust or waste on the inner parts of the device
with possible subsequent failures.
Unhook the automatic switch if you foresee
not to use the device for a long time.
The airflow direction must be properly adjusted.
The user is responsible for having the appliance
installed by a qualified technician , who must
check that it is earthed in accordance with current
legislation and insert a thermomagnetic circuit
breaker.
E
nsure that the appliance is disconnected from
the power supply when it will remain inoperative
for a long period and before carrying out any
cleaning or maintenance.
Selecting the most suitable temperature can
prevent damage to the appliance.
The flaps must be directed downwards in
the heating mode and upwards in the cooling
mode.
T
he batteries in remote controller must be
recycled or disposed of properly.
Disposal of Scrap Batteries --- Please discard
the batteries as sorted municipal waste at the
accessible collection point.
2

SAFETY RULES AND PROHIBITIONS
3
Do not bend , tug or compress the power cord
since this could damage it. Electrical shocks or
fire are probably due to a damaged power cord.
Specialised technical personnel only must replace
a damaged power cord.
Do not use extensions or gang modules.
Do not touch the appliance when barefoot or
parts of the body are wet or damp.
Do not obstruct the air inlet or outlet of the
indoor or the outdoor unit.
The obstruction of these openings causes a
reduction in the operative efficiency of the
conditioner with possible consequent failures
or damages.
In no way alter the characteristics of the
appliance.
Do not install the appliance in environments
where the air could contain gas , oil or sulphur
or near sources of heat.
Do not climb onto or place any heavy or hot
objects on top of the appliance.
Do not leave windows or doors open for long
when the air conditioner is operating.
Do not direct the airflow onto plants or
animals.
Along direct exposition to the flow of cold
air of the conditioner could have negative
effects on plants and animals.
Do not put the conditioner in contact with
water.
The electrical insulation could be damaged
and thus causing electrocution.
Do not climb onto or place any objects on the
outdoor unit
Never insert a stick or similar object into the
appliance. It could cause injury.
T
his appliance is not intended for use by
persons (including children ) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety.
C
hildren should be supervised to ensure
that they do not play with the appliance.
If the supply cord is damaged, it must be
replaced by the manufacturer,its service
agent or similarly qualified persons in
order to avoid a hazard.

NAMES OF PARTS
No. Description
1
2
Front panel
Air filter
Optional filter (if installed)
3
Terminal block cover
4
Emergency button
5
6
LED Display
Signal receiver
7
Airflow direction louver
8Deflectors
9
Remote controller
10
Note: the above figures are only intended to be a
simple diagram of the appliance and may not
correspond to the appearance of the units that
have been purchased.
No. Description
13 Air outlet grille
Terminal block cover
14
gas valve
15
liquid valve
16
11
Indoor unit rating label ( )Stick position optional
17
Outdoor unit rating label
12
Ionizer (if installed)generator
13
15
16
17
INDOOR UNIT
4
OUTDOOR UNIT
12-3
6
4-5
9
11 8
10 7
14
DISPLAY HEALTHY3D
ON/OFF
SWING
FAN
TIMER SUPER
SLEEPMODE
ECO
CLOCK
12
INDOOR UNIT
OUTDOOR UNIT
10

INDOOR UNIT DISPLAY
1
2
5
3
4
1 2 345
The shape and position of switches and indicators may be different according to the model, but their
function is the same.
12 4 5
3
5
1
2
3
4
5
3
12
3
54
No.
Led Function
POWER This symbol appears when the unit is power on
1
2
3
4
5
Temperature display (if present)
/Error code
(1) Lights up during Timer operation when
the air conditioner is operational
(2)Displays the malfunction code when fault
occurs.
SLEEP mode
Lights up during Timer operation.
The symbol appears when the unit is turned
on, and disappear when the unit is turned off.
SLEEP
TIMER
RUN
3
4
2
1245

EMERGENCY FUNCTION & AUTO-RESTART FUNCTION
6
Remark: the externalstatic pressure ofheat pumps is0 Pa forall models.
The shape and position of the emergency button
may be different according to the model, but their
function is the same.
ON/OFF
Emergency
button
The emergency button in some models could be on
the right part of the unit under the front panel.
The appliance is preset auto - restart function by
manufacturer. In case of a sudden power failure, the
module memorizes the setting conditions before the
power failure. when the power restores, the unit
restarts automatically with all the previous settings
preserved by the memory function.
Open and lift the front panel up to an angleto reach the
emergency button.
1. One press of the emergency button(one beep) will
lead to the forced COOLING operation
2. Two press of the emergency button within 3 sec
(two beeps) will lead to the forced HEATING
operation.
3. To switch off the unit , you just need to press the
button again ( a single long beep) .
4. After 30 minutes in forced operation , the air
conditioner will automatically start working in 23
cooling mode, auto fan speed.
* The FEEL function is described in page 15.
If the remote controller fails to work or maintenance
necessary, proceed as follows:
display PCB
front panel
To deactivate the AUTO-RESTART function ,pro-
ceed as follows:
1. Switch the air conditioner off and plug it off.
2. Press the emergency button meanwhile plug
it in.
3. Keep pressing the emergency button for more
than 10 seconds until you hear four short beeps
from the unit. The AUTO-RESTART function is
deactivate.
To activate the AUTO - RESTART function ,
follow the same procedure until you hear three
short beeps from the unit.
Emergency
button
ON / OFF
POWER
SLEEP
TIMER
RUN
EMERGENCY FUNCTION
AUTO-RESTART FUNCTION
Emergency
button
ON/OFF
front panel
1033A

REMOTE CONTROLLER
7
The shape and position of buttons and indicators maybe difference according to the model, but their
function is the same.
The out looking and some function of remote controller maybe difference.
The unit confirms the correct reception of each press button with a beep.
To select the mode of operation
To LED displayswitch on/off the
To activate or deactivate of the movement of the deflectors.
To activate the function SLEEP
To switch - on /off HEALTHY funtion.It is a button which controls the ionizer or
plasma genera for available model only.
In cooling mode,press this button ,the temperature will increase 2 on the base of
setting temperature
In heating mode, press this button, the temperature will decrease 2 on the base of
setting temperature
Press this button to activate / deactivate the Super function which enables the unit to reach
the preset temperature in the shortest time.
In COOL mode, the unit will give the maximum cooling temperature with 16 ,high fan
speed.
In HEAT ode, the unit will give the maximum heating temperature with 31 ,high fan
speed.
Press it to decrease temperature/ time setting.
Press it to increase temperature / time setting.
Press it tostart or stopoperation.
Press it toset auto-off timer
.
To select the fan speed of auto/low/mid/high
No.
8
10
12
6
14
7
9
13
MODE
SWING
DISPLAY
SLEEP
HEALTHY
ECO
SUPER or TURBO
11
3D
CLOCK
1
(TEMP DN)
(TEMP UP)
2
3
4
ON/OFF
FAN
5TIMER
When you press "3D", the horizontal and vertical vanes will swing together at the
same time.
RESET
ANTI-MILDEW
Button Function
To activate the function ANTI-MILDEW
To restart REMOTE CONTROLLER
16
15
When you press this button,the time will be flickering;then through" "and
" ",you can adjust the time(one time you press,one minute you adjust;and if
you continue to press,the time change rapidly ), after adjusting to your required
time, please press this button again to fix the time.
Mute To activate the function of Mute
or or

REMOTE CONTROLLER
ON/OFF
SWING
FAN
TIMER SUPER
SLEEPMODE
ECO
111
3
2
9
13
8
12
4
14
10
5
6
DISPLAY HEALTHY3D
CLOCK
7
1
3
4
5
12
13
10
9
8
7
6
ON OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
DRY
FAN
HEAT
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
2
COOL
FEEL
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
ANTI-MILDEW
SWING SLEEP HEALTHY
DISPLAY RESET
15
16
SLEEP
TIMER SWING
MODE
ON/OFF
2
1
6
5
8
FAN
3
10
4
Auto
Feel Cool
Low
Dry Heat
Mid
High
Sleep
Swing
Timer
OFF
Timer
Fan
C
h
ON
MODE
FAN SLEEP
ECO TIMER
SWING
TURBOHEALTHY
DISPLAY
SWING
6
8
1
2
3
5
12
13
10
10
4
7
9
6
5
8
2
1
3
4
MID
AUTO
SWING X
HIGH
LOW
DRY
FAN
HEAT
COOL
FEEL
SLEEP
SWINGYSUPER
TIMER ON TIMER OFF
ON/OFF
FAN SWING X SWING Y
SUPER SLEEP
MODE
TIMER
10
Mode
Fan
Eco
Temp Swing
Timer
Display
Sleep
Mute Turbo Health
8
3
6
7
9
13
10
5
16
4
1
2
12
8
The shape and position of buttons and indicators maybe difference according to the model, but their
function is the same.
The out looking and some function of remote controller maybe difference.
Mildew
or

REMOTE CONTROLLER
Remote controller DISPLAY
Meaning of symbols on the liquid crystal display
9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
FEEL mode indicator
COOLING indicator
DEHUMIDIFYING indicator
FAN ONLY OPERATION indicator
HEATING indicator
SIGNAL RECEPTION indicator
TIMER OFF indicator
TIMER ON indicator
AUTO FAN indicator
LOW FAN SPEED indicator
or MIDDLE FAN SPEED indicator
or
or
HIGH FAN SPEED indicator
QUIET or
or SLEEP indicator
or
AUTO or
or FLAP SWING indicator
15
SUPER indicator
16
17
HEALTHY indicator
TIMER
ON
or
or
TIMER
OFF
or
HEALTHY
ON
18
ECO indicator
19
ANTI-MILDEW indicator
or
POWERFUL
or
or ECO
or
BATTERY indicator
or
or
or
or
or
or
or
or
or
20
21
22
COMFORTABLE SLEEP indicator (optional)
FEEL indicator(optional)
Meaning
No. Symbols
(FLASH)
FLAP and Deflectors SWING indicator
CLOCK indicator
23
or
or
TURBO
or
24 Mute indicator
or
or
or
or
or
or
or
or
or
or
(FLASH)
or
or

REMOTE CONTROLLER
Signal
receptor
10
DRY
FAN
HEAT
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
COOL
FEEL
DRY
FAN
HEAT
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
COOL
FEEL
+
+
+
DISPLAY HEALTHY
3D
ON/OFF
SWING
FAN
TIMER SUPER
SLEEPMODE
ECO
CLOCK
Remote controller holder
DISPLAY HEALTHY3D
ON/OFF
SWING
FAN
TIMER SUPER
SLEEPMODE
ECO
CLOCK
DISPLAY HEALTHY
3D
ON/OFF
SWING
FAN
TIMER SUPER
SLEEPMODE
ECO
CLOCK
Replacement of Batteries
Remove the battery cover plate from the rear of the remote controller,
by sliding it in the direction of the arrow.
Install the batteries according the direction (+and -)shown on the Remote
Controller.
Reinstall the battery cover by sliding it into place.
Use 2 LRO 3 AAA (1.5V) batteries . Do not use rechargeable
batteries . Replace the old batteries with new ones of the same
type when the display is no longer legible.
Do not dispose batteries as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
NOTE:if you adjust the remote controller in cooling mode,
it will not be possible to activate the heating function in units with
heating pump . you need to take out the batteries and repeat the
procedure described above.
1. Direct the remote controller toward the Air conditioner.
2. Check that there are no objects between the remote control
and the Signal receptor in the indoor unit.
3. Never leave the remote controller exposed to the rays of the sun.
4. Keep the remote controller at a distance of at least 1m from the
television or other electrical appliances.
Recommendations for locating and using the remote controller holder (if present)
The remote controller be kept in a wall-mounted holder
Refer to picture 2:
When you insert the batteries for the first time in the remote
controller or if you change them, you need to program the remote
controller of only cooling or cooling and heating.
When you insert the batteries, the symbols ( ) and
( ) start fashing. If you push whatever button when
the symbol ( ) is displayed, the remote controller is
adjusted in only cooling mode . If you push whatever button when
the symbol ( ) is displayed , the remote controller is
adjusted in Cooling and heating mode.
COOL
HEAT
COOL
HEAT
Refer to picture 1:
i. When you open the battery cover, you can see a DIP switch on
the cover back.l
Ii. NOTE:After adjusting the function, you need to take
out the batteries and repeat the procedure described above.
DIP switch on position
Function
The remote controller is adjusted in degree celsius
The remote controller is adjusted in only cooling mode
The remote controller is adjusted in cooling and heating mode
The remote controller is adjusted in degree fahrenheit.
Cool
Heat
C
F

OPERATING INSTRUCTIONS
Filter
Heat
Fan
Exchanger
“SWING”CONTROL OF THE AIR FLOW
11
flaps
flap
movement Deflectors
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
ANTI-MILDEW
MODE
FAN SLEEP
ECO TIMER
SWING
TURBOHEALTHY
DISPLAY
SWING
AIR
SWING
OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
DRY
FAN
HEAT
COOL
FEEL
C
h
ON
TIMER
HEALTHY
The direction of the air outlet is motorized up and down
by flaps, and manually moved right and left by the vertical
deflectors, for some models, the vertical deflectors could be
controlled by motor as well.
The air sucked by the fan enters from the grill and
passes through the filter, then it is cooled/dehumidified
or heated through the heat exchanger.
The air outlet flow is uniformly dist-
ributed in the room.
It is possible to position the direction
of the air in the optimal.
In cooling mode , orient the flaps in horizontal
direction;
In heating mode, orient the flaps downward as
the warm air tends to rise.
The deflectors are positioned manually and placed un-
der the flaps .They allow to direct the air flow rightw-
ard or leftward.
Never position Flaps manually, the delicate mech-
anism might seriously damaged!
Never poke fingers, sticks or other objects in the air
inlet or outlet vents. Such accidental contact with live
pants might cause unforeseeable damage or hurt.
This adjustment must be done while the appliance
is switched off.
SWING
The key activates the motorized deflectors ,
the air flow is directed alternatively from left to right.
(Optional function, depends on the models)
SWING
The key or activates the FLAP ,
the air flow is directed alternatively from
up to down .In order to guarantee an even
diffusion of the air in the room.
SWING
SWING

OPERATING INSTRUCTIONS
COOLING MODE
The cooling function allows the air condit-
ioner to cool the room and at the same time
reduces Air humidity.
COOL
To activate the cooling function ( COOL ) , press the
MODE button until the symbol ( COOL )
appears on the display.
12
HEATING MODE
OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
DRY
FAN
HEAT
COOL
FEEL
ANTI-MILDEW
C
h
ON
COOL
1
2
3
OFF
C
AUTOQUIET
POWERFUL
TIMER
HEALTHY
DRY
FAN
HEAT
COOL
FEEL
ON
HEAT
ON
hr
DELAY
AIR
SWING
FAN
SPEED
C
h
1
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
ANTI-MILDEW
1
2
3
1
TIMER
HEALTHY
TIMER
HEALTHY
The cooling function is activated by setting the button
or at a temperature lower than that of the room.
To optimize the function of the Air conditioner, adjust
the temperature (1) , the speed (2) and the direction
of the air flow (3) by pressing the button indicated.
HEAT
The heating function allows the air conditi-
oner to heat the room.
To activate the heating function ( HEAT ) , press the
MODE button until the symbol ( HEAT )
appears on the display.
With the button or set a temperature higher than
that of the room..
To optimize the function of the Air conditioner adjust
the temperature ( 1 ), the speed ( 2 ) and the direction
of the air flow ( 3 ) by pressing the button indicated
In HEATING operation, the appliance can automatically
activate a defrost cycle, which is essential to clean the
frost on the condenser so as to recover its heat exchange
function.This procedure usually lasts for 2-10 minutes
during defrosting,indoor unit fan stop operation.
After defrosting ,it resumes to HEATING mode
automatically.
If the appliance is fitted with a electrical heater,
which delays appliance to startup in a few seconds
to ensure an immediate output of hot air (Optional ,
depends on the model).

OPERATING INSTRUCTIONS
POWER SLEEP TIMER RUN
Indoor display
13
TIMER MODE----TIMER OFF
TIMER MODE----TIMER ON
POWER SLEEP TIMER RUN
Indoor display
TIMER
ON
OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
DRY
FAN
HEAT
COOL
FEEL
ANTI-MILDEW
C
h
ON
1
2
3
.
TIMER
HEALTHY
TIMER
HEALTHY
Note: The TIMER function can be set at
half-hour intervals.
TIMER
HEALTHY
POWER SLEEP TIMER RUN
Indoor display
TIMER
OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
DRY
FAN
HEAT
COOL
FEEL
C
h
ON
OFF
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
ANTI-MILDEW
1
.
TIMER
ON To set the time of the air conditioner
To program the automatical switching-on time, the
appliance should be power off.
Press TIMER at the fist time , set the temperature with
pressing the button or ;
Press TIMER at the second time , set the rest time with
pressing the button or ;
Press TIMER at the third time, confirm the setting, then
the rest time to next automatical switching-on could be
read on the display.
NOTE !
Before proceeding with the time: program the working
mode with the button MODE (2) and the fan speed
with the button FAN (3) . Switch the conditioner
off (with the key ON/OFF ).
TIMER
To set the automatic switching-off
of the air conditioner
The timed stop is programmed by pressing TIMER ,
Set the rest time by pressing the button or ,until the rest
time displayed is to your demand then press TIMER again.
OFF
Note:To cancel the setted function ,press the TIMER
button again.
Note:To cancel the setted function, press the TIMER
button again.
Note:In case of power off,it is necessary to set TIMER
ON again
Note:In case of power off,it is necessary to set TIMER
OFF again

OPERATING INSTRUCTIONS
14
FAN
The conditioner works in only
ventilation.
To set the FAN mode , Press MODE untill
( FAN ) appears in the display.
Whith pressing FAN button the speed changes
in the following sequence: LOW/ MEDIUM/HIGH
/AUTO in FAN mode.
The remote control also stores the speed that was set
in the previous mode of operation.
In FEEL mode (automatic) the air conditioner auto-
matically chooses the fan speed and the mode of
operation (COOLING or HEATING).
This function reduces the humid-
ity of the air to make the room
more comfortable.
To set the DRY mode , Press MODE untill
( DRY ) appears in the display .An automatic
function of alternating cooling cycles and air fan
is activated.
DRY
FAN MODE
DRY MODE
OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
DRY
FAN
HEAT
COOL
FEEL
ANTI-MILDEW
C
h
ON
3
FAN
TIMER
HEALTHY
DRY
OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
DRY
FAN
HEAT
COOL
FEEL
ANTI-MILDEW
C
h
ON
TIMER
HEALTHY

OPERATING INSTRUCTIONS
Ambient temp Auto temp.
20 23
23
26
20 ~26
Operation mode
HEATING ( FOR HEAT PUMP TYPE)
DRY
COOL
18
FAN (FOR COOL ONLY TYPE)
To optimize the function of the air conditioner, adjust
the temperature(only 2 )(1), the speed (2) and the
direction of the air flow (3) by pressing the buttons
indicated
To activate the SLEEP mode of operation, press the
SLEEP button on the remote controller until the sym-
bol (AUTOQUIET ) appears on the display.
AUTO QUIET
The function SLEEP automatically adjusts the
temperature to make the room more comfortable
during the night . In cooling or dry mode , the set
temperature will automatically raise by1 every
60 minutes, to achieve a total rise of 2 during the
first 2 hours of operation.
In heating mode the set temperature is gradually
decreased by 2 during the first 2 hours of operation.
After 10 hours running in sleep mode the air conditio-
ner is swicthed off automatically.
15
FEEL MODE
POWER SLEEP TIMER RUN
Indoor display
FEEL
OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
DRY
FAN
HEAT
COOL
FEEL
C
h
ON
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
ANTI-MILDEW
1
2
3
OFF ON
C
AUTOQUIET
POWERFUL
hr
DELAY
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
DRY
FAN
HEAT
COOL
FEEL
C
h
ON
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
SWING SLEEP HEALTHY
ANTI-MILDEW
AUTOQUIET
SLEEP MODE
1
.
.
TIMER
HEALTHY
TIMER
HEALTHY
FEEL Automatic mode.
To activate the FEEL (automatic) mode of operation,
press the MODE button on the remote controller until
the symbol ( FEEL ) appears on the display.
In FEEL mode the fan speed and the temperature
are set automatically according to the room temperature
(tested by the temperature sensor which is incorporated
in the indoor unit).

PROTECTION
16
The air conditioner is programmed for comfortable and suitable living conditions, if it is used in abnormal
conditioner as below, certain safety protection features might come into effect.
Outdoor temperature is over 24
2
Room temperature is over 27
Outdoor temperature is below -7
1
3
Heating
Cooling
Dry
Outdoor temperature is over 43
Room temperature is below 21
Room temperature is below 18 C
For T1 Climate condition models:
For Tropical (T3) Climate condition models:
The unit does not operate immediately if it is turned on after being turned off or after changing the
mode during operation. this is a normal self-protection action, you need wait for about 3 minutes.
No.
MODE
2
1
3
Heating
Cooling
Dry
No.
MODE
Outdoor temperature is over 24
Room temperature is over 27
Outdoor temperature is below -7
Outdoor temperature is over 52
Room temperature is below 21
Room temperature is below 18 C
Ambient temperature
Ambient temperature
The capacity and efficiency are according to the test conducted at full-load operation*.
*The highest speed of indoor fan motor and the maximum open angle of the flaps and deflectors
are requested.

INSTALLATION MANUAL---Selecting the Installation Place
condensed water drain pipe
150
150
150
Sleeve
insulating covering
electrical cable
Mounting plate
Do not install the outdoor unit near sources of heat,
steam or flammable gas.
Do not install the unit in too windy or dusty places.
Do not install the unit where people often pass.Select
a place where the air discharge and operating sound
will not disturb the neighbours.
Avoid installing the unit where it will be exposed
to direct sunlight ( other wise use a protection , if
necessary, that should not interfere with the air flow).
Reserve the spaces as shown in the picture for the air to
circulate freely.
Install the outdoor unit in a safe and solid place.
If the outdoor unit is subject to vibration, place rubber
gaskets onto the feet of the unit..
water drain pipe
300
500
2000
300
minimum space to be reserved (mm) showing
in the picture
500
Outdoor unit
Indoor unit
be less than 5m
Height should
Outdoor unit
Indoor unit
be less than 5m
Height should
Installation Diagram
17
INDOOR UNIT
OUTDOOR UNIT
The purchaser must ensure that the person and/or company who is to install, maintain or repair this air
conditioner has qualifications and experience in refrigerant products.
Install the indoor unit on a strong wall that is not subject
to vibrations.
The in let and outlet ports should not be obstructed:the
air should be able to blow all over the room.
Do not install the unit near a source of heat , steam,or
flammable gas.
Install the unit near an electric socket or private circuit.
Do not install the unit where it will be exposed to
direct sunlight.
Select a site where the condensed water can be easily drained
out, and where it is easily connected to outdoor unit.
Check the machine operation regularly and reserve the
necessary spaces as shown in the picture.
Select a place where the filter can be easily taken out.
Should be less
than 15m
Should be less
than 15m

INSTALLATION MANUAL---Installation of the Indoor unit
50
5mm
Note : Keep the drain pipe down towards the direction
of the wall hole, otherwise leakage may occur.
Before starting installation, decide on the position of the
indoor and outdoor units, taking into account the minim-
um space reserved around the units
To install, proceed as follows:
The hole must slope downwards towards the exterior
Note : The shape of the mounting plate may be different
from the one above, but installation method is similar .
Indoors Outdoors
Front panel
Terminal block cover
wiring diagram
18
Installation of the mounting plate
Drilling a hole in the wall for the piping
Electrical connections---Indoor unit
Do not installyour air conditioner in a
wet room suchas a bathroom or laundry etc
The installation siteshould be 250cm or more
above the floor.
1 Always mount the rear panel horizontally and vertically
2. Drill 32 mm deep holes in the wall to fix the
plate;
3. Insert the plastic anchors into the hole;
4 .Fix the rear panel on the wall with provided tapping screws
5.Be sure that the rear panel has been fixed firmly enough
to withstand the weight
1. Make the piping hole ( 55) in the wall at a slight
downward slant to the outdoor side.
2. Insert the piping-hole sleeve into the hole to prevent the
connection piping and wiring from being damaged when
passing through the hole.
1. Open the front panel.
2. Take off the cover as indicated in the piciure ( by
removing a screw or breaking the hooks).
3. For the electrical connections, see the circuit diagram
on the right part of the unit under the front panel.
4. Connect the cable wires to the screw terminals by
following the numbering ,Use wire size suitable to
the electric power input (see name plate on the unit)
and according to all current national safety code
requirements.
The cable connecting the outdoor and indoor units
must be suitable for outdoor use.
The plug must be accessible also after the appliance
has been installed so that it can be pulled out if nece-
ssary.
An efficient earth connection must be ensured.
If the power cable is damaged, it must be replaced by
an authorised Service Centre.
Note:Optional the wires can been connected to the main
PCB of indoor unit by manufacturer according to the
model without terminal block.
This manual suits for next models
2
Table of contents
Languages:
Popular Air Conditioner manuals by other brands

Mitsubishi Electric
Mitsubishi Electric PUZ-ZM200YKA2-ET Service manual

Whynter
Whynter ARC-12SDH instruction manual

Hitachi
Hitachi RAM-55QH4 Service manual

Tecumseh
Tecumseh TC300 SERIES Operator's manual

Frigidaire
Frigidaire LRA257ST216 installation instructions

Airwell
Airwell AW-CFM012-N11 Service manual