Lakes LK861 Installation and operating instructions

Island Sliding Door & Side Panel
Installation & Maintenance Instructions
04.19
10.19

IMPORTANT NOTES :
Please read carefully & retain these instructions for future reference.
1. For ease & safety we advise that two persons assemble this product.
2. Protect shower tray surface at all times.
3. Exposed glass corners/edges MUST NOT contact hard surfaces at any time.
4. Check for cables, pipes etc. before drilling walls.
5. Ensure all surfaces are dry, clean & free from loose debris or dust.
6. Unpack goods with care (small parts can become lodged in packaging and inadvertantly discarded)
Check parts supplied against parts and ttings listed herein.
Damaged parts / omissions may be resolved by calling Lakes helpline.
7. Whilst precautions are taken in manufacture, care must be taken when handling as rail ends may have sharp edges.
8. Before commencing, check that :
a) shower tray (if used) is level & completely sealed to nished / tiled walls.
b) nished walls are sound and free of cracks, loose tiles / grout.
9. AFTER INSTALLATION DO NOT WET ENCLOSURE FOR 48 HOURS TO ENSURE FULL CURE OF SILICONE SEALANT.
Use :
General Care & Maintainance.
Provided this product is installed and operated in accordance with these instructions problems should not arise
however should maintainance be required it should be carried out by a competant person with reference to these
instructions. Before any work is carried out, the root cause of the problem must be identied. Lakes service engineers
are available if necessary to consult / carry out remedial work. Call Lakes helpline.
Cleaning. (Every one to two weeks depending on local water (hardness) conditions)
All glass panels in this product have a hydrophobic coating which aids “runo” of water droplets, reducing the need
for frequent cleaning however for best appearence & product life regular cleaning is recommended.
Use ONLY mild soap / detergent solutions to clean, rinse with water, squeegee glass panels and wipe frames dry
with a soft cloth. Under no circumstances should abrasive, caustic or scouring products be used. Non-complience
with these cleaning instructions may cause decorative nishes to deteriorate & could adversly aect safe operation
of the enclosure.
Daily Care.
To prevent the build up of limescale, do not allow water droplets to dry on glass or frames. After showering, rinse
with water, remove droplets of water from glass with a squeegee & wipe frame with a soft cloth.
Customer Service.
Quality guarantee : Lakes Bathrooms Ltd. guarantee shower doors and enclosures against any manufacturing or
material defects fot the lifetime of the product. We will resolve defects free of charge by repairing / replacing parts
as we feel necessary. To be free of charge, service work must be carried out by Lakes Bathrooms or approved agents.
Seals are considered“wear & tear” parts and as such are guaranteed for 12 months from purchase.
Not covered by this guarantee : Damage or defects that result from improper installation, improper use or lack of
maintenance (including limescale buildup). Damage or defects that result from repairs / modications undertaken.
by unauthorised persons. This guarantee is in addition to statuatory and other legal rights.
What to do if anything goes wrong : Should the product not fuction correctly on initial use, rstly contact the insaller
to check that unit installation & comissioning are in accordance with these instructions. Should this not resolve
diculties or should performance decline, consult ‘Troubleshooting’ section of these instructions to see if simple
home maintenance is needed. alternatively our helpline sta can assist or arrange for a service engineer to visit if
necessary.
Spares : We maintain an extensive spare parts stocks. spares can be ordered / purchased from your retailer in the rst
instance. Parts will normally be despatched within two working days from placement of order.

Parts List :-
Island Sliding Door
(Seperate Boxed Product)
Side Panel &
Trim Assembly
Magnetic Seal Kit Threshold Corner Kit
Corner Bracket Kit
Wall Profile
Assembly
Wall Prole
Cover

Tools Required :-
Power drill & 8mm
masonry or tile bit
Pencil Spirit level with vertical bubble
Tape measure
Pozidriv screwdriver
Good quality silicone
sealant and applicator
Allen keys
(2.5, 3, & 5mm)
Hacksaw
Setting Out :-
Door Size
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
Adjustment (mm)
970 - 995
1070 -1095
1170 - 1195
1270 - 1295
1370 - 1395
1470 - 1495
1570 - 1575
1670 - 1695
1770 - 1795
1870 - 1895
1970 - 1995
Side Panel Size
700
750
800
900
1000
Adjustment (mm)
675 - 695
725 - 745
775 - 795
875 - 895
975 - 995
Ensure tray is completely level and all tray / wall edges
are completely sealed prior to installation.
DO NOT BEGIN INSTALLATION ON A TRAY WHICH
HAS NOT BEEN FULLY SEALED.

Door Size
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
“X”
Position “X”
982
1082
1182
1282
1382
1482
1582
1682
1782
1882
1982
To nd outside of wall prole positions,
measure & mark “X” & “Y” for selected enclosure size.
Using position “X” , oer wall prole up to wall and
ensuring the prole is completely plumb, mark
centre of slots in wall prole.
Drill marked positions with 8mm bit and t
wall plugs then repeat process for side panel prole.
Fix using M4 x 40mm screws and washers
Repeat fo side panel prole (Y)
1.
3.
4.
Assemble threshold to suit handing.
1. Insert threshold bar assembly into
end of corner joining trim.
2. Fix with M4 x 10mm screw
3. Insert glazing gasket
4. Insert buer to suit hand
Push xed panel glass & trim assembly
into wall prole, repeat with side panel.
Holes in glass of side panel must be to
front of enclosure.
Panel Size
700
750
800
900
1000
Position “Y”
680
730
780
880
980
“Y”
2.

Lower threshold assembly onto tray and slide end trim under the side panel glass.
Ensure threshold is parallel to front of tray and distance from front is equal along it’s
complete length (10mm Min.)
Fit xed panel into wall prole and
lower into threshold channel.
Fixed panel glass (A) should be tted
with hole countersinks to the front
of the enclosure and with open edge
adjacent to guide block in centre of
threshold.
(A)
G
l
a
s
s
G
u
i
de
B
l
o
ck

Assemble horizontal rail to suit desired hand.
Door assembly for
RIGHT HAND enclosure.
Door assembly for
LEFT HAND enclosure.
Wheel assembly
Handle assembly
Assemble door to suit desired hand.
Fixed Panel Spigot Kits
Blanking Kit
Rail End Cap
Horizontal rail set up for
RIGHT HAND door shown.
Reverse for Left Hand.

Part assemble corner bracket as shown below to suit desired handing of enclosure.
Assembly to suit RIGHT HAND door.
Reverse and use opposite doorstop
buer for left hand.
Assembly for
xed panel spigot.
Assembly for
blanking kit.
Remove 2x screws from top of open
end of horizontal rail and
take out doorstop. Slide horizontal rail onto
assembled door.
Ensure wheels are running
on the track.
Fix bracket to rail
using screws
removed when taking
out doorstop.
Use boss tment tool to hold
boss in place during assembly

1 .
2.

1

Adjust door so that bottom edge of glass runs as close as
possible to guide without interference.
With the door closed, use 3mm allen key through
holes in top of horizontal rail to raise or lower the door.
Door may need moving slightly to left or right to align
hole and adjusting screw.
Z
With drip lip to INSIDE, offer threshold capping upto threshold corner. Adjacent to centre
guide block, measure / mark length required & neatly / squarely cut capping to length Z
before fitting.
Push magnetic seals onto edge
of door glass and side panel.
Seals may be wetted to ease fit.
threshold corner
centre guide block
(cut at this end of capping ONLY)

Apply a continuous bead of clear silicone sealant as shown EXTERNALLY ONLY.

Basic Troubleshooting :
Door motion noisy / Door not running smoothly.
Check edge seals not dragging on glass or fouling any other part of the enclosure
Check wheels engaged correctly on track and roll smoothly
Check door glass adjusted correctly (not dragging on guide)
Leakage:
The sealing method described in these instructions relies on a continuous seal being applied
between walls & tray before installing the enclosure, it ensures a watertight seal around the
perimeter of the enclosure to the shower walls & tray.
In the unlikely event of an enclosure leak water will be visible on the outside of the
enclosure itself or around the perimeter joints only. Water appearing outside of the
enclosure i.e. at oor level is normally due to incorrect tray installation.
Lakes Bathrooms Ltd.
Alexandra Way
Ashchurch
Tewkesbury
Gloucestershire
Gl20 8NB
Service - England, Scotland, Wales.
08:30 - 17:00 Mon to Thurs
08:30 - 16:30 Fri
Tel:- 01684 853870
Email:- admin@lakesshoweringspaces.com
www.lakesshoweringspaces.com
Service - Northern Ireland
Ian A Kernohan
Firtrees
Green Way Industrial Estate
Conlig
Northern Ireland
BT23 7SU
08:30 - 17:00 Mon to Thurs
08:30 - 16:30 Fri
Tel:- 02891 270233
Email:- info@iakonline.com
Table of contents
Other Lakes Bathroom Fixture manuals
Popular Bathroom Fixture manuals by other brands

Axor
Axor MyEdition 70 47050 1 Series Installation/User Instructions/Warranty

Fantini Rubinetti
Fantini Rubinetti PARTI INCASSO N017A instructions

Helvex
Helvex H-3008 installation guide

Tribata.
Tribata. Bastow GEORGIAN G5318 quick guide

Triton
Triton SALSA Installation and operating instructions

Hans Grohe
Hans Grohe Vernis Blend 71420 Series Assembly instructions

Kohler
Kohler K-2210 Installation and care guide

BELLOSTA
BELLOSTA romina 1003 Installation instruction

Hans Grohe
Hans Grohe Finoris 230 76060 Series Instructions for use/assembly instructions

Pfister
Pfister Hanover 808 Series manual

Viega
Viega Advantix 4935.1 Instructions for use

ROGERSELLER
ROGERSELLER Flow 123002 quick start guide