LANBO LAC8000W User manual

Pre-Water-Cooling Portable Air Conditioner
Model:LAC8000W
Model:LAC8000G
Model:LAC8000WG
USER MANUAL
LANBO

2
CONGRATULATIONS
Congratulations,and thank you for purchasing your new Lanbo
Appliances product.We are confident you will be pleasantly
surprised with the simplicity of use.Before installing and
operating your new appliance,please thoroughly read through
this manual for product description and functions.
To avoid any risks associated with using an electric appliance,it
is important that you read the safety instructions and that the
appliance is installed properly in accordance with the
instructions to avoid potential hazards.Please keep this
instruction manual for future reference if needed.
After unpacking the appliance,please inspect it to verify it is not
damaged.If in doubt,do not use the appliance and contact
Lanbo Appliances customer service center.
CUSTOMER SERVICE:
For assistance or questions regarding your product,please contact
our customer service team at service@lanboappliances.com .
Thank you for your trust and support in Lanbo Appliances!
LANBO INTERNATIONAL INC.
Website:www.lanboappliances.com
Email:service@lanboappliances.com

3
CONTENTS
Important Safety Instructions...................... 4
Diagram of Portable Air Conditioner........ 5
Installation........................................................... 7
Operation Instructions.................................... 8
Display and Operation Instructions.......... 10
Specifications.................................................... 11
Troubleshooting................................................ 12
Care and Maintenance.................................. 14
Warranty.............................................................. 15

4
Important Safety Instructions
Precautions
To reduce the risk of fire,electrical shock,or injury when using your
appliance,follow these basic precautions:
• Before operation,ensure your electrical installation (outlets and
circuits)complies with the power specifications found on the unit.
Before cleaning or maintaining the air conditioner,please turn off
air conditioner and unplug the unit.
Make sure the power cord isn’t kinked,bent,or under the weight of
sharp or heavy objects.
• Do not pull or yank the power cord to unplug the unit or move the air
conditioner.
• Do not insert or unplug the power plug with wet hands.
• Only use a grounded power outlet.Make sure the grounding is
functional.
If the power cord is damaged,it must be replaced by the
manufacturer or a qualified technician in order to avoid fire and
electrical hazards.
• Should abnormal operation occur (such as a burning smell), please
disconnect power cord immediately and contact your local dealer.
• If nobody is present to monitor the operation of the unit,please turn
it off and disconnect the power cord.
Do not splash or pour water on air conditioner to avoid causing a
short circuit or damage to the unit.
• Do not put or hang dripping objects above the air conditioner.
• Keep heat sources away from the air conditioner.
• Ensure the unit is far away from fire,inflammable,or explosive
objects.
• Never allow children or persons with reduced physical,sensory,or
mental capabilities to operate or play around the air conditioner
without direct adult supervision.
• Never allow children to perform cleaning or other user-maintenance.
•
•
•
•

5
Diagram of Portable Air Conditioner
1. Air Outlet
2. Oscillating Vertical Grill
3. Horizontal Grill
4. Control Panel
5. Castors
6. Air Filter
7. Power Cord

6
8. Drain Inlet Cover
9. Water Level Window
10. Drain Outlet Cover
11. Exhaust Vent
12. Low Pressure Air Grid

7
Installation
Special Warning
• After unpacking the appliance,please inspect to verify it is not
damaged.
• Confirm all electrical parameters are consistent with the product
requirements.
• The air conditioner should be placed on a firm,level surface to
minimize noise and vibration.For safe and secure positioning,
place the unit on a smooth,level floor strong enough to support
the unit.
• The unit has casters to aid in maneuverability,but it should only
be rolled on smooth,flat surfaces.Use caution when rolling on
carpeted surfaces.Do not attempt to roll the unit over objects.
• The unit must be placed within reach of a properly rated
grounded socket.
• Never place any obstacles around the air inlet or outlet (11)of
the unit.
• Allow 10 to 12 inches of space from the wall with for efficient
air-conditioning and prevent overheating.
• Keep product away from direct sunlight and other heat sources
such as stoves,radiators,electric heaters,etc.Direct sunlight will
discolor the case and increase energy consumption.
• Never place any obstacles around the air inlet or outlet (11)of
the unit.
• Connect power cord to a qualified receptacle.The shape and
voltage of the socket must be the same as listed on the
nameplate on the back of the case.

8
Operation Instructions
1.When using air conditioner for the first time,open the drain
inlet cover (8), and use the drain hose and funnel to add water
into the water tank.You may also use a gallon pitcher to
slowly fill tank (water tank capacity is 7.3 gallons). Note:Use
low water pressure when filling tank,as excessive pressure
will cause water to overflow.Please check the water level (9),
when water reaches maximum level (MAX), stop filling tank
and close the drain inlet cover (8). Excess water will be
discharged from the drain outlet (10). Connect drain hose to
drain outlet cover (10)to empty water tank.Do not move the
product during water filling.After filling water tank,plug in to
wall outlet.

9
2.Allow unit to sit 8-10 hours before powering on,and DO NOT
push any buttons on the control panel or remote control.After
the recommended 8-10 hours,your unit is ready to power on.
The unit will be in cold storage mode when it is powered on.If
the air conditioner’s cooling capacity is largely reduced,power
off the switch and unit will automatically enter the cold storage
mode.The unit will continue to cool for 8-12 consecutive
hours.
COOLING CAPACITY/OPERATIONAL HOURS
Cooling capacity:160 sq.ft.
Hi-Speed:Cools for 8 hours
Medium-Speed;Cools for 10 hours
Low Speed:Cools for 12 hours
TIPS:In the cold storage mode,the compressor continues to work
until the water in the tank is completely frozen before the compressor
stops.Allow 8-10 hours for optimum freezing time depending on room
temperature.
Once the unit has been in operation for more than 8-10 hours,the
cooling efficiency becomes equivalent to the Fan-Mode.Power off
the unit. (ATTENTION:PLEASE DO NOT UNPLUG THE POWER
CORD)or switch the cooling mode to other modes.The unit will enter
the cold storage mode for another 8-10 hour.Repeat.

10
Display and Operation Instructions
Control Panel:
1.Power Button:ON/OFF
2.Mode Selection Button:
a.Cooling b.Dehumidifier c.Fan
3.Fan Speed Selection:
a.Slow b.Medium c.Fast
4.Display Area
5.Increase Temp Button:Max Temp 88℉
6.Decrease Temp Button:Min Temp 61℉
7.Infrared Sensor
8.Left and Right Oscillation
Note:Temperature cannot be adjusted when in Dehumidifier Mode or
Speed Mode.Fan Speed cannot be adjusted in Dehumidifier Mode.

11
Remote:
1
2
4
3
5
7
8
96
10
11
hr
1.Display Area 2.Increase Temp Button
4.Decrease Temp Button 5.Mode Selection Button
6.Time Setting Button 7.Screen Light Off Button 8.Left and Right
Swing Oscillation 9.Fan Speed Selection 10.Sleep Function button
11.Power Button:ON/OFF
Specifications
1.Package Contents:Portable air conditioner,remote,user manual,
fill hose with funnel,drain hose.
2.Product Size(WxDxH):17.3 x 19.5 x 44.5 inches
3.Net Weight:84.9 lbs
4.Gross Weight:97.4 lbs
5.Package Size(WxDxH):21.9 x 23.4 x 46.1 inches
6.Cooling Capacity:8000 BTU
7.Voltage:110-120 V
8.Frequency:60 Hz
9.Waterproof Level:IP0
10.Refrigerant &Injection Volume:R600A 75g
11.Noise:45 dB
12.Water Tank Volume:7.3 gallons

Troubleshooting
1.Diagnose:Please troubleshoot according to the following table
before contacting maintenance.
Problems Troubleshoot Steps Solution
AC is not
working
Is the power off? Turn on power supply.
Is the plug loose? Plug in correct way.
Has the power switch tripped
or the fuse burned out?
Check electric breaker box for a trip
or seek technical support
Does not start immediately
after it stops?
Please wait 3 minutes before
restarting.
Poor
cooling
effect
Is the voltage too low? Wait for the voltage to return to
normal.
Is the filter dirty? Clean the filter.
Is the setting temperature
appropriate?
Set the temp lower than
ambient temperature.
Are the doors and windows
closed? Close the door and windows.
Remote
is not
working
Whether it has received
strong interference (such as
static electricity,abnormal
power supply voltage)
Unplug it and plug it back in
about 3 minutes,and restart
the AC.
Is the remote control within
the receiving range?
T he receiving range of the remote
Is there an obstruction? Remove the obstruction.
Is the battery low? Replace batteries.
No wind
blowing
Is the air filter blocked? Remove obstruction from filter.
Is the filter is dirty? Clean the filter.
Odor Is there a source of odor in
the room or from the filter?
Remove the source of odor
and clean the filter.
12
control is within 394 inches,
please do not exceed the range.

2 TroubleshootingCodes:
E1:Environmental temperature sensor failure.
Solution:Please contact service technician for assistance via
service@lanboappliances.com.
E2:Water tank temperature sensor failure.
Solution:Please contact service technician for assistance via
service@lanboappliances.com.
3.Warning:
If the following malfunctions occur,please stop the unit and power it
off immediately.Do not attempt to repair or modify the AC by yourself,
please contact a service technician for immediate assistance.
The power cord is unusually hot or damaged
Irregular or unusual operation
A burning odor
Water leakage
.
13

Care and Maintenance
•Cleaning:
Power off unit.Unplug and open the drain cover and then
unscrew the valve switch to drain water.
Wipe the outside of unit with a soft cloth and clean water.
Take off the air filter and clean it with water and then assemble
•Changing Water:This unit has a fully enclosed water tank and
can be changed once a year.Empty water in the tank,then refill
•Draining:To drain the water from tank,open drain cover,
connect hose to the drain pipe,and turn drain switch to the right.
•Filter Cleaning:It is recommended to clean filter every 1-2
months.Open the filter cover on the left side of the air conditioner,
pull out the filter,wipe it clean,dry and then replace.
•Seasonal Cleaning:Preparing unit for storage,unplug power
cord,empty water tank,clean filter,and wipe down the outside of
the air condition.
14
a.
b.
c.

Warranty
For all maintenance,replacement and warranty services,
please contact Lanbo customer service email:
service@lanboappliances.com
Lanbo provides 12-month machine warranty and 36-month
compressor warranty to consumers (warranty starts from
the date of purchase). Lanbo will provide warranty service
according to the status of the product,including but not
limited to maintenance,refund or replacement of products
of the same value.
Limited warranty does not include:damage caused by
accident,abuse,improper use,negligence,unauthorized
repairs or any other reasons beyond the seller ’s control.
The buyer understands and admits that the goods sold here
are mobile air conditioners.The purchaser bears all risks of
using these devices,including deterioration,humidity
changes,temperature changes,leaks,fire,water damage,
mold,mildew,dryness and the risk of similar hazards.
Special note:The warranty only applies to machines
purchased and used in the United States.Moreover,if your
product was purchased at any third-party retailer rather
than directly from Lanbo,we do not provide an extended
warranty policy.You must contact the purchasing retailer
directly.If your retailer does not provide an extended
warranty plan,we recommend that you contact a third-party
warranty provider.However,no matter where you buy it,all
Lanbo portable air conditioners are guaranteed by the
manufacturer for 12 months from the date of purchase.
15

This manual suits for next models
2
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual