SKINTOP® CLICK Assembly Instructions
1. Position and press the gland
into the housing.
(all snap-fits have to be clicked)
. Fasten the gland with counter-
clockwise rotation of the pressure nut.
3. Lead the cable through.
4. Tighten the cap nut by the hand with a clockwise
rotation during you hold the pressure nut.
5. Retighten the cap nut with prescribed torque.
SKINTOP® CLICK Disassembly Instructions
1. Position the disassembly tool and
push the tool over latch to unlock.
. Open latch system by pressing
with both thumbs on SKINTOP®
CLICK.
3. Push out SKINTOP® CLICK with
both thumbs.
Dimension
Diameter for
unthreaded
holes
[mm]
SKINTOP ®
CLICK
clamping-and
sealing range
[mm]
SKINTOP ®
CLICK-R
clamping-and
sealing range
[mm]
Torque M
[Nm]
Ø1 1 ,3 -0, 4,5 - 7 3,5-5 1,0
Ø16 16,3 -0, 5 - 9 4-7 ,5
Ø 0 0,3 -0, 7 - 13 5-10 6
Ø 5 5,3 -0, 9 - 17 6-13 8
Ø3 3 ,3 -0, 11 - 0 7-15 7
Temperature range:
- 0°C bis +100°C
Deutsche Montageanleitung siehe Rückseite