LaserLight LL-2500 User manual

User's Manual
FOUR TUNNELS RED AND GREEN LASER SHOW SYSTEM
LL-2500
Read this manual before using. Do not attempt to open the housing or repair
this device by yourself without contact us!

This chart lists the DMX dipswitch setting for DMX address 1 through 511. Follow the
instructions below to configure fixture dipswitches with you desired DMX address.
DMX Address Quick Reference Chart
Page 9
DMX Address Chart
DipSwitch Position
DMX Address
DipSwitch Position

Notes:
1. DMX console can not be used in Master-Slave operation (Sound Active or AUTO mode ).
2. There should be only one master unit in Master-Slave operation. Unpacking:
Thank you for purchasing this product. Please read user guide for safety and operations
information before using the product. Keep this manual for future reference. This product
can create perfect laser programs and effects since it has passed a series of strictly tests
1. If the power supply indicator doesn't light up and the laser doesn't work, please check the before delivery. Please check the attachments listed on the page after opening the carton.
power supply and the input voltage. In the event of carton damage or attachment missing in transit, please contact your dealer
2. In Stand-Alone operation, if the power supply indicator is light up and sound active indic- or our after sales service department.
ator isn't light up, but the laser is shut off doesn't work.
A. Because sound is too small make for laser shut off in sound active, please increase the Attachments:
music volume or increase audio sensitivity with sensitivity knob, please check as below. 1. Laser Light: 1PCS
B. Please check if unit has been set up in slave mode, then set up in master mode. 2. Power Cable: 1PCS
3. In Master-Slave operation, slave unit don't function, please check as below. 3. User Guide: 1PCS
A. Make sure to there's only one master in the chain, and the others are set in slave mode.
B. Make sure to control the unit without DMX console controlling.
C. Make sure to take a good quality power cable and connection. Notice:
4. In DMX mode operation, the laser is OFF and the DMX signal indicator is unlighted, pl- 1. Do not exposure the human eye direct to laser beam.
ease check as below. 2. Do not turn on and off the unit frequently.
A. Make sure to set up the DMX mode. 3. Before using this unit make sure the power supply is ground.
B. Make sure to have a good connection.
4. This unit is intended for indoor use only and should be prevented form water, moisture
5. In DMX operation, the unit can’t be controlled by the DMX console, but the DMX signal
and shake. The working temperature of this unit is 18~30℃, do not use this continuously
indicator is flashing, please make sure the DMX console and unit have the same channel. over 4 hours, otherwise it shortens the lifetime of the unit.
6. If the output beam direction above isn't the right way, please restart the unit. 5. Use cleaning tissue to remove the dust absorbed on the external lenses periodically to
7. If the unit is fail, please turn off the unit, then turn on again after 5 minutes.
optimize light output.
6. Do not remove or break the warranty label, otherwise it void the warranty.
After trying the above solution you still have a problem, please contact your dealer or 7. Always replace with the exact same type fuse, replacement with anything other than the
our company for service. specified fuse can cause fire or electric shock and damage your unit, and will void your ma-
nufactures warranty.
DANGER
LASER RADIATION AVOID EXPOSURE
TO BEAM CLASS 3B LASER PRODUCT
Page 8 Page 1
!
General instructions
Troubleshooting

Master-Slave Operation
This mode will allow you to link up to 32 units together without controller.
1. Voltage: AC110V or AC220V-240V/ 50HZ-60HZ/ Fuse: 2A/250V 1. Install the units in a suitable position (laying or appending).
2. Rated Power: 30W 2. Choose a unit to function as Master mode, set dipswitch to select Sound Active or
3. Laser: 25+25mW@532nm, green DPSS laser,100+100mW@650nm, red DPSS laser AUTO mode. The others must be set to Slave mode, set dipswitch to select Slave mode.
4. Working Modes: DMX, Sound Active, AUTO, Master-Slave 3. Use standard XLR microphone cable chain your units together via the XLR connector
5. DMX Control Channel: 7 channels on the rear of the units. For longer cable runs we suggest a terminator at the last fixture.
6. Graphics & Effects: more than 100 patterns, over 300 effects 4. Turn on the all units' power, the units begins reset, then the unit begins working. The
7. Interface: 3 pins XLR jack for DMX or Maser-Slave linking
slave units will react the same as the master unit.
8. Size: 600*180*150mm 5. The units will react to the low frequencies of music via the internal microphone. Adjust
9. Weight: 6.8Kg the audio sensitivity knob on the back of the master unit to make the unit more or less se-
nsitive in sound active.The panel has LED indicating for sound active.
1. Various working modes
Includes four working modes as DMX, Sound Active, AUTO and Master-Slave Control
for different applications. Universal DMX Operation (DMX mode)
2. Various programs This mode allows you to use universal DMX-512 console to operate.
The double tunnel laser beam is compages, more than 50 laser patterns, over 200 laser 1. Install the units in a suitable position (laying or appending).
effects. Different working modes has different program. 2. Use standard XLR microphone cable chain your units together via the XLR connector
3. DMX control on the rear of the units. For longer cable runs we suggest a terminator at the last fixture.
The unit has 7 channels to control in DMX mode. The unit has BLACK OUT function. 3. Assign a DMX address to each the unit using dipswitches, see the "DMX Address
The uint will shut OFF if no DMX512 signal.
Quick Reference Char".
4. Master-Slave function 4. Turn on the all units' power, the units begins reset, then the unit begins working.
The system allow link many units (as slave unit) together to doing synchro job without
5. Use DMX console to control your units.
console in sound active or AUTO mode.
5. LED indicating and shut-off function
In sound active mode, the unit's panel has LED indicating for sound active. The unit will
shut off after 8 seconds when the music stops.
6. DPSS Laser
Use Diode-Pumped Solid State green laser, stable output and long working life.
Page 2 Page 7
Technical Specification
Features
……
1: Master: Sound/AUTO
POWE
N:Slave
2:Slave
1: DMX Mode
N:DMX Mode
2:DMX Mode
……
POWE
DMX Signal

DMX address calculation
For DMX mode, DMX512 address from #1 to 9# dipswitches must be set, the address is
set from 1 to 511. Each dipswitch represents a binary value.
Dipswitch Value Dipswitch Value
#11#632
#22#764
#34#8128
#48#9256 Front Panel Figure
#516 #10
Set to "0"
1. Laser Aperture One 2. Sound Active Microphone
One unit has 7 channels, so each unit must be assigns 7 channels at least. We may assign 8
3. Sound Active Indicator:Blue 4. Power Indicator:Red
channels for one unit, then DMX address = 8*N + 1, N=0, 1, 2, 3 ……
Example
One loop address=1, two loop address=9, three loop address=17, four loop address=25
Loop Address Binary Dipswitches
1 1 100000000 #1
2 9 100100000 #1+#4
3 17 100010000 #1+#5
4 25 100110000 #1+#4+#5 Rear Panel Figure
The dipswitches setting for DMX address see the " DMX Address Quick Reference Chart ". 1. Power Jack 2. Cooling Fan
3. Audio Sensitivity Knob
4. DMX Signal Indicator: Green
5. Dipswitches: Function Setting 6. DMX or Linking Jack
Stand-Alone Operation (Sound Active, AUTO mode)
The mode allows a single unit to react to the beat of the music in the master mode.
1. Install the units in a suitable position (laying or appending).
2. Set dipswitch to select Sound Active or AUTO mode. Sound Active
3. Turn on the unit power, the unit begins reset, then the unit begins working. The change of the laser pattern is controlled by sound, that is, the rhythm of the sound
4. The unit will react to the low frequencies of music via the internal microphone. Adjust control the effect of the changing laser pattern. Turning the sensitivity knob in the
the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in clockwise direction to increase the fixture’s sensitivity to sound, the knob in the counter
sound active.The panel has LED indicating for sound active. clockwise direction to decrease. The laser diode will automatically turn off after 8 seconds
when the music stops.
AUTO
Auto cycles the built-in programs without being controlled externally. It has no laser
OFF
Page 6 Page 3
Function & Setting
Operation
Front/Rear Panel
1: Master: Sound/AUTO
2: Master:
N: Master: Sound/AUTO
……
POWE
POWE
POWE
1
5
6
2
3
4

DMX Control
The system only accepts the DMX512 signal of international standard to control the system
mode, the laser pattern ON /OFF, the size, the position, the speed, etc.
DMX Control Parameter Chart
Close, laser OFF
Static patterns of DMX mode
Dynamic patterns of DMX mode
Sound active mode
AUTO mode
Pattern selection 52 static/dynamic patterns
Position-X Adjust position-X
Position-Y Adjust position-Y
Scanning speed 0 is speedy, 255 is slow There are 52 static patterns, the sizes of the patterns that DMX value is 140 previous are
Dynamic pattens
0 is speedy, 255 is slow, has ten
adjustable, the following irregular patterns are non-adjustable. There are 52 dynamic pat-
play speed
grade speed
terns, whose sizes are non-adjustable.
Static pattern size 0 is small, 255 is big
Function setting
CH2 Parameter Chart For Function Uses dipswitches to assign a unit’s function: DMX/slave, or sound active, or AUTO mode.
For the unit is DMX mode, set the DMX address. Each dipswitch represents a binary value.
See the “Function chart”.
Dipswitch #10 is use to set master or slave mode. Master modes have sound active and
AUTO mode. Slave modes have DMX and Slave mode. The units automatically identify
DMX or SLAVE mode by data receives. Dipswitch #9 use to is set sound active or AUTO
mode in master mode.
Page 4 Page 5
60~64
V line 1
ladder line 3
dot rectangle turn
ve-flex dot line
square extend
ladder line 1
dot square extend
dot diagonal
ladder line 2
dot circle jump
190~194
circle jump
185~189
45~49
dot diagonal
dot circle to add
175~179
rectangle turn
50~54
135° diagonal
scan circle extend
180~184
55~59
35~39
vert-dot line
40~44
45° diagonal
dot circle turn
170~174
circle turn
165~169
ho-flex dot line
vertical line move
ver-extend line
vert-dot line move
vert-flex line
dot rectangle extend
25~29
hori-dot line
circle roll
155~159
vert-shrink line
rectangle extend
30~34
vertical line
dot circle roll
160~164
15~19
scan circle
20~24
horizontal line
dot circle flash
150~154
circle flash
145~149
chiasma line
hori line flex
hor-extend line
hori dot line flex
hori-flex line
hori dot line move
5~9
dot circle 1
dot circle to big
135~139
hori-shrink line
hori line move
10~14
dot circle 1
scan circle to big
140~144
0~4
circle
circle to big
130~134
christcross
dot diagonal move
DMX value
Static patterns
Dynamic patterns
DMX value
Static patterns
Dynamic patterns
CH5
0~255
CH6
0~255
CH7
0~255
many dot 2
square dot jump
CH4
0~255
125~129
dot rectangle 2
45° diagonal move
255
square dot
many dot jump 2
CH3
0~255
120~124
rectangle 2
dot line scan
250~254
dot wave flowing
CH2
0~255
115~119
dot rectangle 1
line scan
245~249
many dot 1
many dot jump 1
200~255
110~114
rectangle 1
long sector round 2
240~244
spirality line
dot bird fly
150~199
105~109
dot square
long sector round 1
235~239
wave dot line
wave flowing
100~149
100~104
square
short sector round 2
230~234
wave line
220~224
pentagon 3
pentagon star turn
50~99
95~99
dot triangle 2
short sector round 1
225~229
pentagon 4
bird fly
diagonal jump
215~219
pentagon 2
tetragon turn
CH1
Mode
0~49
90~94
triangle 2
dot diagonal jump
Channel
Function
Value
Description
85~89
dot triangle 1
80~84
triangle 1
ver-dot line jump
210~214
pentagon 1
dot pentagon turn
70~74
V line 2
hori-dot line jump
75~79
V dot line 2
vertical line jump
200~204
DMX value
Static patterns
tetragon 1
dot square turn
tetragon 2
pentagon turn
205~209
Dynamic patterns
Dynamic patterns
65~69
V dot line 1
hori-line jump
195~199
ladder line 4
square turn
DMX value
Static patterns
Function Chart





Table of contents
Popular Floodlight manuals by other brands

HQ Power
HQ Power VDLLUF user manual

Night Watcher
Night Watcher NW1200X Installation & operating manual

superbrightleds
superbrightleds FLCKM Series user manual

MegaLite
MegaLite Indi PAR RW300 user manual

HQ Power
HQ Power VDPLPS36BP user manual

Timeguard
Timeguard LEDPRO10WH Installation & operation instructions

Tranberg
Tranberg TEF 9964 Helideck user manual

Teryair
Teryair TSL-50 FLOOD TYPE Operation and maintenance guide

GE
GE PF-154 instructions

HOLOPHANE
HOLOPHANE Predator Small Floodlight Marine Installation and maintenance manual

Eterna
Eterna SAP70MINI Safety and installation instructions

Fanton
Fanton 62660 instructions