LAUNDRY SOLUTION SX205100A User manual

LAUNDRY SOLUTION CO., LTD.
Tel : 076-617171 / 089-7246756 / 086-2762580
Website : www.laundryparts.in.th mail : [email protected]
SX205100A
Dryer Controller
User Manual
Please read the man al caref lly before installation and operation!
Software version
X1.LC001A.X20.001-1 V100A4
Rights Reversed, Pirate P nished

【Safety Precautions】
Installatio
n
Please x the controller to avoid vibrate drops。
Please install the controller in the metal or not
inammable board.
Please guarantee electric cabinet temperature among
-10℃~+50℃ adding the ventilating fan when
necessary.
Do not expose in the sunlight strong airow and mist
Do not expose in corrosive and pollution gas such as
sulde gas salt mist.
Wiring
Please conrm the power supply is OFF.
Let the professional worker to wiring
Signal without source input please do not connect with
power supply
Please increase the system protection, avoids the
controller invalid and cause dangerous.
Please observe the strong and weak electricity
separation principle.
Please use the conforms to the technical standard wire
Please select the parallel method
Parameter According to the machine conguration set the related
parameter guarantees the machine running.
Run
After conrming the wiring correctly then power on.
Guarantee environmental condition and the power
supply voltage is in permit condition only in this way
can start the machine.
When running please do not inspect the signal.
When running please do not change the parameter
setting.
When running please do not approach the machine.
Maintenan
ce,
inspection
The user has any repair needs please contact with
manufacturer do not intend to repair it by yourself.
Please do not pull twist the power line and
communication line.
Please do not touch the controller device directly.
Others Please be careful when simulating and adjusting the
controller on the desk.Presence of high voltage could
cause electrical hazard and injury.
Symbol explanation
Please familiarize yourself with the following standard warning symbols. They are
used throughout this manual to alert you the possible hazards. Anyone installing
operating and servicing this controller must understand these symbols and follow all
the safety rules in this manual.
It ill cause the dangerous situation, possibly ill cause
the personal injury or death hen error using.
It ill cause the dangerous situation, possibly ill lead to
personal injury or death, property damage and economic
loss hen error using.
【Responsibility statement】

In case of any consequence which corrupts or bugs the
controller’s software PUNP reserves the right to repair the
bug but does not have the responsibility to undertake any
compensation.
In case of the controller’s hardware error PUNP has the right
to repair the aw but does not have the duty to undertake
any responsibility.
Because of improper use PUNP does not have the duty to
undertake any responsibility.
PUNP has the right to go to the end user’s service but does
not have the duty.
NOTE:This manual is subject to change ithout separate noti%cation.

Content
1. G N RAL..............................................................................................................................................5
2. INSTALLATION.....................................................................................................................................6
2.1. Dimension....................................................................................................................................6
2.2. lectric connection.......................................................................................................................7
3. FRAME CHART.....................................................................................................................................8
4. BUTTONS INTRODUCTION.................................................................................................................9
5. RUNNING.............................................................................................................................................10
5.1. Startup........................................................................................................................................10
5.2. Idle mode...................................................................................................................................10
5.3. Automatic running mode............................................................................................................10
5.3.1. Start automatic running...................................................................................................10
5.3.2. Change time,temperature................................................................................................10
5.3.3. nding automatic running................................................................................................10
6. PROGRAMMING.................................................................................................................................11
6.1. Select and enter.........................................................................................................................11
6.2. dit.............................................................................................................................................11
6.3. xit and save..............................................................................................................................11
7. PARAMETER.......................................................................................................................................12
7.1. Parameter initialization...............................................................................................................12
7.2. Machine parameter setup..........................................................................................................12
7.3. Modify password........................................................................................................................13
8. ALARM.................................................................................................................................................14
8.1. Alarm reset.................................................................................................................................14
8.2. Alarm information and obviation................................................................................................14

SX205100A Dryer Controller
1. GENERAL
This schematic photo is just for reference!
The controller is specially designed for the control of the automatic dryer. It features stability and
reliability in operation.
The controller has very convenient human-machine interaction interface with liquid crystal display
to show state of operation of the machine including temperatures at Led display and thus helps
monitoring effect.
5 different cycles can be programmed and upon a single touch of the [R n] key, the machine will
run automatically to the end of the selected cycle.
5/16

SX205100A Dryer Controller
2. Installation
2.1. Dimension
6/16

SX205100A Dryer Controller
2.2. Electric connection
220VAC/ 24VDC
L
COM1
220VAC/ 24VDC
COM2
Com1
Fwd
Rev
Heat 1
Heat 2
Fan
Cool
Al arm
Com2
Power input
Gnd
I nput
Emergency Stop
Overheat
Motor overload
Door Single
Gnd
Outdrum temperature
Indrum temperature(Optional)
Wiring chart
123 4 567 8 912
123123 4 1 2345
N
NOTE:Thi drawing i only for reference.
Note:
(1)The diagram above is only for reference.
(2)Voltage outputs of the transformer is AC9.8V (loaded voltage), do not directly connect to AC
220V.
(3)The transformer should be configured by users if the input voltage range of the transformer is
out of the of : AC220V(±10%).
(4)Voltage connected with relay ≤ AC220V (DC 24V); Relay current < 5A
(5)Output to carry an electric voltage for connecting, the customer can connect into according to
own effective demand, needing not certainly AC220V.
(6)Do not use the port standby.
(7)Make sure the temperature around the controller and the connecting cable is lower than 60℃.
7/16

SX205100A Dryer Controller
3. Frame chart
Power on
Startup
Machine Check
Parameter Setup
Idle
Select Program Alarm
Run Program Edit Program
8/16

SX205100A Dryer Controller
4. B ttons introd ction
This schematic photo is j st for reference!
Icon Function
[Start] button
Under “Door Closed” and “Idle” status, press this button to start executing the selected
automatic formula.
[Stop] button
1.Under “auto” Mode, press this button to stop current running formula.
2.When there is an error appeared in the machine, the computer will signal an alarm
automatically with audible sound. Pressing this button will stop audible alarm sound. Press
this button again after troubleshooting. If the error has been resolved or can be ignored, the
computer will go back to “Idle” status. Or else the controller will alarm again.
[Set] button
1.In the count down status, press this button for 3 seconds, you can enter into user
parameter setup.
2.In the idle status, press this button, you can enter into user program edit.
[Up] button
1. When running, you can change motor direction mode, single direction or bi-direction.
2. Under setting status, press this button to choose your desired item.
[Down] button
1. When running, you can change motor direction mode, single direction or bi-direction.
2. Under setting status, press this button to choose your desired item.
9/16

SX205100A Dryer Controller
5. R nning
5.1. Start p
After power is on, the LCD shows the startup interface for 10 seconds. If press [Set] button for 3
seconds during the 10-second-display, you can enter into user parameter setup.
5.2. Idle mode
Not use temp. sensor of in drum Use temp. sensor of in drum
5.3. A tomatic r nning mode
5.3.1. Start a tomatic r nning
On Idle interface, choose your desired program by pressing [Down] or [Up] buttons under “Door
Closed” status, and then press [R n] button to start the program.
Drying Cooling
The left of 1st line, display the current running program number.
The left of 2nd line, display the current running action.
The right of 1st line and 2nd line, display the time.
3rd line and 4th line, display the temperature of in drum and out drum.
5.3.2. Change time,temperat re
Select the setting items by pressing [Set] button and set the value by pressing [Down] or [Up]
button.
5.3.3. Ending a tomatic r nning
After complete cool, the controller becomes ending status. The controller beeps on to clue user,
you can stop the buzzer by pressing [Stop] button during this beeping time.
Note: In the dry process, press [Stop] button to come into cool process. And in the cool process,
press [Stop] button to end the program.
10/16
Auto Dryer
9
X1LC001AX2000
1-1.V100A00
4

SX205100A Dryer Controller
6. Programming
There are 5 programs on the controller.
6.1. Select and enter
Select your desired program under “Idle” status by pressing [Down] or [Up] buttons, and pressing
the [Set] button, then the LCD will ask you to input the passwords.
After inputting correct passwords, it will enter into “program” status.
Default password is empty, you can enter the interface without entering passwords..
6.2. Edit
1st page 2nd page
Select the setting items by pressing [Set] button and set the value by pressing[Down] or [Up]
button.
Items Defa lt Range Introd ction
Dry parameters
Dry hour 1 0-9
Dry min 0 0-59
Dry temp 90℃0-255 ℃Temperature of out durm when dry.
Cool parameters
Cool hour 0 0-9
Cool min 10 0-59
Cool temp 30 0-255 Temperature of out durm when cool.
Other parameters
Motor dir BiDi BiDi、SiDi BiDi:the motor rotating in bi-direction.
SiDi:the motor rotating in single direction
Dry mode Time Time、
Temp
Time:The controller begin to count down regardless of
the dry temperature.
Temp:The controller begin to count down when reach
the dry temperature.
DryInDrum 120 ℃0-255 ℃Temperature of in durm when dry.
6.3. Exit and save
If press the [Stop] button under “program” status, the controller will exit with saving the program.
11/16
Input pa word-8
DryHourMin: 01:00
Dry temp: 90℃
CoolHourMi: 00:10
Cool temp: 30℃
Motor dir: BiDi
Dry mode: Time
DryInDrum: 120℃

SX205100A Dryer Controller
7. Parameter
Note: All parameters have already been config red for the machines in factory. Don’t intend to
modify any parameter witho t any special req irement. Some modification will lead to abnormal
work.
After power is on, the LCD shows the startup interface. Press [Set] button for 3 seconds during the 10
seconds counting down,then the LCD will ask you to input the passwords.
After enter the correct password, you can enter into parameters setting interface.
Default password is: [Up], [Down], [Up], [Down], [Down], [Up], [Down], [Up]
Press [Down] or [Up] button to select setting item and press [Set] button to enter into the selected
item.
After modification, press [Stop] button for 3 seconds to reserve the modified value and exit to the
idle page.
7.1. Parameter initialization
On the top menu Of parameter setup interface, press [Down] or [Up] button to select “1:Reset
data” and press [START] button to enter into this item.
Press [Down] or [Up] button to select “1: Reset paramet.” and press [Set] button to reset all the
parameters to default value.
Press [Down] or [Up] button to select “2: Reset program” and press [Set] button to reset all the
programs to default value.
Press [Stop] button to exit.
7.2. Machine parameter set p
On the top menu Of parameter setup interface, press [Down] or [Up] button to select “2:Machine
setup” and press [Set] button to enter into this item.
12/16
Input pa word-8
PARAM T RS
1:Reset data
2:Machine setup
<Stop>3S quit
1:Reset data
1:Reset paramet.
<Set> start
<Stop> quit
2:Machine setup
1:Fwd run time
Now: 10sec
<Stop> quit

SX205100A Dryer Controller
Select the sub-item by pressing [Down] or [Up] button and enter the setting mode by pressing
[Set] button. Under the setting mode, you can set the value by pressing [+] or [-] button.
Press [Stop] button to exit.
Items Defa lt Range Introd ction
1) Drum roll time 35sec 0~255sec Time of motor forward/reverse run.
2) Drum stop time 35sec 0~255sec Time of motor forward/reverse stop.
3)Heat1 temp dif 2℃0~255℃The difference of temperature allow main heat acts.
4)Heat2 temp dif 5℃0~255℃The difference of temperature allow assistant heat
acts.
5)Door closed N.O. N.O.
N.C.
Open: Door closed when input signal is invalid.
Close: Door closed when input signal is valid.
6)MotorOverload N.O. N.O.
N.C.
Open: Motor overload when input signal is invalid.
Close: Motor overload when input signal is valid.
7)Overheat N.C. N.O.
N.C.
Open: Overheat when input signal is invalid.
Close: Overheat when input signal is valid.
8) mergency N.C. N.O.
N.C.
Open: mergency stop when input signal is invalid.
Close: mergency stop when input signal is valid.
9)InDrumSensor No No, Yes Yes: Use temperature sensor of in drum.
10)In drum ctrl No No, Yes Yes: Control temperature of in drum.
11)In drum alarm 150℃70~180℃
Max temperature of in drum.
When the temperature is higher than the set value, the
controller will alarm.
12)OutDrumAlmDif 15℃1~30℃
Difference of temperature for out drum temp alarm.
Max temperature of out drum = Diff. temp+ Program
Setting temp.
13)Language Chinese Chinese,
nglish
14)Temp. units Celsius Celsius,
Fahrenheit
7.3. Modify password
On the top menu of parameter setup interface, press [Down] or [Up] button to select “3: Mod.
password” and press [Set] button to enter into this item.
1
2
3
In passwords inputting screen,once a button pressed, a “*” will be displayed on the LCD. [Set] is
used to delete and [Stop] is used to exit the screen.
13/16
Old password-8 New password-8 Confirm password

SX205100A Dryer Controller
8. Alarm
8.1. Alarm reset
When error occurs, the computer will signal an alarm automatically with audible sound.
Pressing [Stop] button will stop audible alarm sound. Press [Stop] button again after
troubleshooting. If the error has been resolved or can be ignored, the computer will go back to
“Idle” status. Or else the computer will alarm again.
8.2. Alarm information and obviation
No. Alarm Name Troubleshooting
#2 OutDrumSensor Please check temperature sensor of out drum.
#3 InDrumSensor Please check temperature sensor of in drum.
#4 MotorOverload Please check the capacity of machine, or check the input of overload.
#5 Overheat Please check the input of Overheat.
#6 OutDrumTmpHi The temperature of out drum is higher than Max temperature of out drum.
#7 InDrumTmpHigh The temperature of in drum is higher than Max temperature of in drum.
#8 mergency Please check the input of mergency stop.
#51 Paramet. err Please contact with factory.
#52 Program err Please contact with factory.
#53 System err Please contact with factory.
14/16
Table of contents
Other LAUNDRY SOLUTION Controllers manuals