LawnMaster BQH3500 Installation manual

SAFETY AND OPERATING MANUAL
PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT
BQH3500(E) / BQH4000(E)
INVERTER
GENERATORS
PROUDLY
NZ OWNED
A STEELFORT PRODUCT

2A STEELFORT PRODUCT | STEELFORT.CO.NZ
I. OPERATOR SAFETY... 3
II. FEATURES & CONTROLS... 5
CONTROL PANEL... 5
III. OPERATION... 8
OPERATION CHECKLIST... 8
OPERATION CONDITIONS... 8
ENGINE OIL... 8
ENGINE FUEL... 9
GROUNDING... 10
BATTERY CONNECTION... 10
IV. STARTING THE GENERATOR... 10
STARTING FUNCTIONS... 10
WIRELESS REMOTE CONTROL ... 11
V. CONNECTING TO ELECTRICAL DEVICES... 12
LOADING CAPACITY... 12
WATTAGE REFERENCE CHART... 13
VI. STOPPING THE ENGINE...13
VII. PARALLEL CONNECTION... 12
VIII. MAINTENANCE... 14
MAINTENANCE SCHEDULE... 15
GENERATOR MAINTENANCE... 16
ENGINE MAINTENANCE... 16
AIR FILTER... 17
SPARK PLUG... 18
SPARK ARRESTER... 18
IX. STORAGE & TRANSPORT... 19
X. TROUBLESHOOTING... 20
XI. SPECIFICATIONS & WIRING DIAGRAMS... 21-23
XII. WARRANTY... 24-26
TABLE OF CONTENTS

3
A STEELFORT PRODUCT | STEELFORT.CO.NZ
I. OPERATOR SAFETY
SAFETY RULES
This manual contains important safety information
and instructions to operate the LawnMaster Inverter
Generator.
PLEASE READ THIS MANUAL CAREFULLY BEFORE
USING THE UNIT.
Failure to adhere to the safety instructions could
result in property damage and/or serious personal
injury.
This manual should be considered a permanent part
of the generator and should remain with the unit at
all times. All information in this publication is based
on the latest product information available at the
time of printing.
Product Information and specications can be
altered and/or improved without notice.
Content from this publication may not be reproduced
without written consent.
DANGER
Indicates a hazardous situation which, if not strictly
complied with, will result in substantial property
damage and or serious injury.
WARNING
Indicates a hazardous situation which, if not strictly
complied with, may result in property damage
CAUTION
Indicates a hazardous situation which, if not strictly
complied with, could result in property damage or
personal injury.
The warnings and precautions discussed in this
manual does not cover all possible conditions and or
scenarios that may occur.
It must be understood by the operator that common
sense and caution must be taken into consideration
when operating this product, as these are factors
which cannot be built into this manual.
WARNING
This generator is intended for domestic consumer
use only. Damage and faults created from
commercial use may void warranty. These generators
are designed for full time operation. No personal
modications should be made to any part of the unit.
DANGER
TOXIC FUMES
• The exhaust of the engine contains carbon
monoxide, an odorless, colorless poison gas.
Using the engine in conned/indoor spaces can
be extremely dangerous and life threatening.
• DO NOT use the generator inside and or in
enclosed spaces EVEN IF doors and windows
are open. Only use the engine in well
ventilated areas and consider wind and airow
when positioning the engine.
KICKBACK
• Rapid retraction of the starter cord will pull
hand and arm towards the engine faster than
you can let go. Unintentional startup can result
in serious injury.
FIRE
• When operating the unit, the engine may create
sparks that could trigger res.
• When operating around dry vegetation such as
agricultural crops, forest, bush, grass, or other
similar environments please be careful.
• This engine may not be equipped with a spark
arresting muer. In some countries and
regions, a spark arrester is required by law.
Please contact your local council and or re
agency for laws and regulations relating to re
prevention requirements.
• Petrol is highly ammable and explosive. A
re and or explosion from petrol can cause
severe burns or result in serious personal injury
including death.
• Keep ammable items away while handling
petrol. Fill fuel tank outdoors and in a well
ventilated area with the engine stopped.
• Always wipe spilled fuel and wait until the fuel
has dried before starting the engine.
• DO NOT operate the engine with known leaks
in the fuel system. Use proper fuel storage and
handling procedures.
• DO NOT store fuel or other ammable materials
near the generator.

4A STEELFORT PRODUCT | STEELFORT.CO.NZ
• Empty the fuel tank before storing or
transporting the generator. Keep re
extinguisher handy at all times.
BATTERY
• Lithium battery is maintenance free, if you have
any question, please contact a local authorised
dealer.
HOT SURFACE
• Running the generator will produce heat and
severe burns may occur upon contact. DO NOT
touch the engine while under operation or just
after stopping the unit.
• Avoid contact with hot exhaust gases and or
hot surfaces.
• Maintain at least 1m of clearance on all sides
to ensure adequate cooling. Combustible
material can catch re upon contact. Maintain
at least 3m of clearance from combustible
materials.
MOVING PARTS
• Moving parts can cause severe injury. Keep
hands and feet away from the unit.
• DO NOT operate engine with covers, shrouds,
or guards removed.
• DO NOT wear loose-tted clothing, dangling
drawstrings or items that could become caught
or entangled.
• Tie up long hair and remove jewelry. The
moving parts may catch operator’s hand, feet,
hair and or loose clothing resulting in serious
injury.
GENERAL WARNINGS
• Before use, check for loose or damaged parts,
signs of oil or fuel leaks, and any other
condition that may impact operation.
• Repair or replace all damaged and or defective
parts immediately.
• Locate all operating controls and safety labels.
• Make sure all the safety instructions are in
correct working condition.
• Operate only on level surfaces.
• DO NOT expose the generator to excessive
moisture, dust, and or dirt.
• Keep all safety guards in place and in proper
working order at all times.
• DO NOT allow any material to block the cooling
slots.
• DO NOT allow children or untrained people to
operate the unit.
• DO NOT leave the generator unattended when
it is in operation. Always turn off the generator
prior to leaving the area.
ELECTRIC SHOCK
• The generator produces powerful voltage and
the electricity and can be dangerous and cause
serious life threatening injuries if an electric
shock is received.
• Please ensure that the unit is properly
connected to an appropriate ground to help
prevent electric shocks.
• Failure to properly ground the unit can result
in electrocution, especially if the generator
is equipped with a wheel kit. Consult an
electrician for local grounding requirements.
• Installation should be performed by a certied
electrician. Improper Installation could result in
serious injury.
• To reduce the risk of electric shocks. DO NOT
use electrical cords that are worn, frayed, bare
or otherwise damaged.
• DO NOT touch bare wires or receptacles.
• DO NOT operate the unit in wet weather.
• Keep the generator dry and DO NOT handle
generator or electrical cords while standing in
water, while barefoot, or while hands or feet
are wet.
• Keep children or pets away.
• DO NOT plug the unit into a building electrical
system without the proper use and installation
of a transfer switch installed by a qualied
electrician.
• When using the generator for backup power,
notify your utility company.
• Use approved transfers to isolate generator
from electric utility.
• Failure to isolate the unit from the power utility
could result in serious injury to the staff and
utility workers due to back-feed of electrical
energy.

5
A STEELFORT PRODUCT | STEELFORT.CO.NZ
II. FEATURES & CONTROLS
1. Fuel Cap
2. Telescoping Handle
3. Control Panel
4. Combination Switch
5. Recoil Starter
6. Oil Drain Plug
7. Air Filter Housing
8. Battery Cover
9. Muer
10. Muer Blind Window
11. Spark Plug Cover
Stop - Off - Run - Choke
1. Power Indicator
2. Overload Indicator
3. Running Indicator
4. Oil Alarm Indicator
5. Fuel Display
6. USB Ports
7. Energy Saving Switch
8. DC Circuit Breaker
9. 12V DC
10. AC Circuit Breaker
11. AC American Type Receptacle
(Applicable Models)
12. Ground Terminal
13. Parallel Kit Terminal
14. AC 20A Circuit Breaker
15. AC Output Receptacle
16. Rest Button
17. Push Button Start
18. Circuit Breaker
19. T Type DC Output

6A STEELFORT PRODUCT | STEELFORT.CO.NZ
OVERLOAD INDICATOR (RED)
When the overload indicator is on, it indicates that
the generating set is overloaded and then the AC
circuit breaker has tripped. It will stop the power
output of generating set to protect the electric
equipment and the generator set itself. At this time,
the running indicator (green) is off and the overload
indicator (red) is on, but the engine is still in running
state.
When the generating set has no output and the
overload indicator is on, please take the following
steps:
1. Lower the total load of the connected electric
devices to the rated output range of the
generator.
2. Check the air lter to ensure it is not clocked
and the generator is in an open area to allow
enough air ow to the generator.
3. Press the reset button.
RUNNING INDICATOR (GREEN)
The running indicator lights up when generating set
starts and has normal output.
OIL ALARM LAMP (YELLOW)
When the oil level drops below the lower limit, the oil
protection system will stop the engine automatically
and oil alarming lamp will blink when recoil starter is
pulled. The engine will not run until the oil has been
lled to the proper level.
Note: If engine stalls or fails to start, turn the
combination switch to “RUN” position and then pull
the recoil starter. If the oil alarming lamp lights up,
it shows lack of oil. Please add appropriate oil and
restart the engine.
RESET BUTTON
The reset button is used to restore output if an
overload occurs. To restore output, reduce the
load(s) and press the reset button.
ENERGY-SAVING SWITCH
When the energy-saving switch is in “ON” position,
the energy saving equipment controls the engine
rpm according to the connected loads. There will
be good fuel consumption and low noise. When the
energy-saving switch is in “OFF” position, the engine
will always run at full rpm no matter what load is
connected to it.
Note: Please set the energy-saving switch to “OFF”
position when connect to an air compressor, pumps,
circular saws etc., Due to large starting current
required.
GROUNDING TERMINAL
The grounding terminal is designed to prevent
electric shock by connecting it to the grounding wire.
The generating set must be properly grounded before
operation.

7
A STEELFORT PRODUCT | STEELFORT.CO.NZ
COMBINATION SWITCH
(STOP & OFF & RUN & CHOKE)
Note: One-button start and remote control start have
auto chokes.
Stop: Switch to turn the generator off.
Note: After the generator is unloaded, please run for
3 minutes with no load to stabilize the temperature,
then stop the generator.
Off: Fuel shut off valve. This position can run out of
the remaining fuel to ensure old fuel is not present
when generator has not been used for long periods.
Note: If you do not plan to use the generator in the
near future, please use this function, or drain the
fuel inside the carburettor using the drain bolt on the
carburettor bowl.
Run: The generator operates normally.
Choke: Close the choke.
Note: Turn to choke position to start when engine is
cold, and turn to Run position to start when engine
is hot.
CIRCUIT BREAKER
When the generator is overloaded or has overheated,
the thermal protection works. Please reduce the
load, or run it for a few minutes without load. Press
the circuit breaker button to restore output power to
equipment.
Note: The circuit breaker is inuenced by factors,
such as operation current and ambient temperature,
so the protection time varies.
PARALLEL KIT TERMINAL
It is used for parallel operation with another inverter
(parallel kit sold separately).
FUEL TANK CAP
Remove the fuel tank cap by rotating it anticlock-
wise.
VENTILATION KNOB (IF APPLICABLE)
The fuel cap is equipped with a ventilation knob
to prevent fuel leakage. During operation, the
ventilation knob must be in the “ON” position for the
generator to operate normally. When the genera-
tor will not be use for a long time or needs to be
transported, turn the ventilation knob to the “OFF”
position to prevent fuel leakage.
TELESCOPING HANDLE
When moving the generator, please hold the tele-
scoping handle and press the button on it, and pull
it outward.
Note: Before moving, please turn off the generator
and fuel switch. Please move the generator on a
relatively at ground. Do not perform the movement
on a surface where the pit exceeds 40mm.

8A STEELFORT PRODUCT | STEELFORT.CO.NZ
III. OPERATION
1. OPERATING CHECKLIST
OPERATING LOCATION
Only use this generator OUTSIDE and in well
ventilated areas.
Only operate the generator on a at, level surface and
in a clean, dry operating environments. Only use the
generator for applications within its operating scope.
If you have any question regarding applicable scope,
please speak to your nearest Service Agent.
In some locations and regions, the generator may
require additional provisions and or regulations for
operation, please consult with your nearest Service
Agent.
DANGER
TOXIC FUMES
The exhaust of the generator contains carbon
monoxide, using the engine indoors may cause
serious personal injury including death. DO NOT use
the generator inside any buildings or within enclosed
spaces EVEN IF doors and windows are open. Place
the generator in a well-ventilated and clean area.
Note the wind direction and airow when placing the
generator.
HIGH ALTITUDE
This generator may require a high altitude carburetor
kit to ensure correct operation at high altitudes.
Consult with your local authorised dealer for high
altitude kit information if you intend to operate
the generator at altitudes above 5, 000 feet (1,500
meters).
CAUTION
• Even with carburetor modication, generator
horsepower will decrease by 3.5% for every
1,000 feet (300 meters) increase in altitude.
The effect of altitude on horsepower will be
greater than this if no carburetor modication
is made.
• Operating the engine at altitudes below 5, 000
feet (1,500 meters) with a modied carburetor
may cause the generator to overheat and result
in serious engine damage. Please restore
factory specications of the carburetor with
your service dealer when using the engine in
low altitude areas.
2. OPERATING CONDITION
Check for loose or damaged parts, signs of oil or fuel
leaks, and any other condition that may affect proper
operation. Repair and or replace with genuine spare
parts immediately.
WARNING
• Failure to correct problem(s) before operation
may result in property damage and or serious
personal injury.
• Remove excessive dirt or debris, especially
around the muer and recoil starter.
• DO NOT move or tip the generator during
operation.
3. ENGINE OIL
• Place the engine on a level surface with engine
stopped. Check the engine oil level.
• Remove the oil maintenance cover.
• Remove the dipstick and wipe it clean.
• Reinstall dipstick into hole; rest on oil ll neck,
DO NOT thread cap into hole.
• Remove the dipstick again and check oil level.
Level should be between the upper and lower
limit.
• Fill to the upper limit of the dipstick with the
recommended oil if the oil level is too low.

9
A STEELFORT PRODUCT | STEELFORT.CO.NZ
Reinstall and fully tighten the dipstick.
Refer to add oil instruction in MAINTENANCE section
for more information.
Oil capacity (rated):
See Parameters
WARNING
• Oil is a major factor affecting performance and
service life.
• We recommend using LawnMaster 4-Stroke
10W30 Oil (PP01020005). You can nd more
information about this in the MAINTENANCE
section of this manual.
• OIL MUST BE PLACED IN ENGINE BEFORE
STARTING. This engine is not lled with oil at
the factory. Any attempt to crank or start the
engine before it has been properly lled with
the recommended type and amount of oil may
result in engine damage and void your warranty.
CAUTION
Operate generator only on level surfaces. The engine
is equipped with a low oil sensors (if applicable) that
will automatically stop the engine when the oil level
falls below safe threshold. To avoid the inconvenient
unexpected shutdowns, ll to the upper limit and
check oil levels regularly.
4. ENGINE FUEL
• With the engine stopped, check the fuel level
gauge. Rell the fuel tank if necessary.
• Use clean, fresh, regular unleaded petrol.
• DO NOT mix oil with petrol.
• Always wipe up any spilled fuel.
• Be sure not to ll above the upper limit mark
• Always allow room for fuel expansion.
• DO NOT use engine and or carburetor cleaning
products in the fuel tank as this could result in
permanent damage.
• It is important to prevent gum deposits from
forming in essential fuel system components,
such as the carburetor, fuel lter, fuel hose or
tank during longterm storage. Also, experience
indicates that alcohol-blended fuels (gasohol,
ethanol or methanol) can attract moisture,
which could lead to separation and formation
of acids during longterm storage.
• Acidic fuels can damage the fuel system while
in storage. Be sure to review the instructions in
the “Storage” section.
• Petrol/Alcohol Blends: up to 10% alcohol, 90%
unleaded petrol by volume is approved as a
fuel. Other forms of petrol/alcohol blends are
not approved.
• Damage and faults caused by old, stale or
contaminated fuel may void warranty.
DANGER
• Do not ll the fuel tank above the upper limit.
Over lling will result in engine damage and
may void warranty.
• Petrol is highly ammable and extremely
explosive. Keep ammable items away while
handling petrol as this could result in a re.
• Fill fuel tank outdoors and well-ventilated areas
with the generator stopped.
• Always wipe off spilled fuel and wait until the
fuel has dried before starting the generator.
CAUTION
• To minimise gum deposits in your fuel system
and to insure easy starting, do not use petrol
that is left over from the previous seasons.
• Pressure can build up in the fuel tank. Allow
the generator to cool for at least two minutes
before removing fuel cap. Loosen the fuel cap
slowly to relieve any pressure in the tank.

10 A STEELFORT PRODUCT | STEELFORT.CO.NZ
5. GROUNDING
• The generator must be properly connected
to an appropriate ground. It helps prevent
electrical shock if a ground fault condition
exists in the generator or in connected
electrical devices, especially when the unit is
equipped with a wheel kit. Proper grounding
also helps dissipate static electricity, which
often builds up in ungrounded devices.
DANGER
ELECTRICAL SHOCK
Failure to properly ground the generator could result
in electric shocks.
A ground terminal on the frame of the generator has
been provided and can be found on the end of the
generator. For remote grounding, connect a (4 mm2)
length of heavy gauge copper wire between the
generator ground terminal and the copper rod driven
into the ground.
The National Electrical Code requires that the frame
and external electrically conductive parts of this
generator be properly connected to an approved
earth ground. Local electrical codes may also require
proper grounding of the unit. We strongly
recommend that you consult with a qualied
electrician for grounding requirements in your area.
6. BATTERY CONNECTION
(IF APPLICABLE)
Remove the battery maintenance cover, connect the
battery terminal to the motor terminal, and reinstall
the maintenance cover.
IV. STARTING THE GENERATOR
Pull the starter handle 6-8 times to prell fuel system
before initial operation or removal from long term
storage. Failure to do so could result in bad starting
experience.
1. Perform operating checklist (see page 10) and
remove all loads.
2. Turn the ventilation knob of fuel cap to the
“ON” position to ensure fuel ow.
(Some Applicable Units)
The following are suitable for hand start:
3. COLD START
Turn the combination switch to “CHOKE”
position to shut off the choke.
WARM START
Turn the combination switch to “RUN”
position, if not started, please turn the
combination switch to “CHOKE” position
before restarting.
4. MANUAL START
1. When starting engine, grasp the recoil
starter handle and pull slowly until
resistance is felt. Then pull rapidly to
avoid kickback. When pulling the recoil
starter, Firmly grasp the generator to
avoid tumble of generator or personal
injury caused by tumble.

11
A STEELFORT PRODUCT | STEELFORT.CO.NZ
WARNING
Check starter cord conditions before operating. Have
it replaced immediately by local authorised dealer if
cord is frayed.
DANGER
Beware of KICKBACK. Rapid retraction of the starter
cord will pull hand and arm towards the engine faster
than you can let go. Unintentional startup may result
in serious personal injury.
5. ELECTRIC START
Cold/ hot engine start (electric start):
Turn the combination switch to “Run”
position. Press the engine switch and
release it after the engine starts
If it fails to start, release the switch. The unit will
restart by itself. If it fails to start after repeated 5
times, please allow the generator to cool for 1 minute
and start again.
IMPORTANT
• Do not continue to start the generator without
identifying the fault.
• DO NOT try to start the generator after
changing to a different battery without
authorisation.
• If the generator fails to start after three
attempts, the generator still fails to start or
stops after starting, please search and solve
the fault.
• The engine should not exceed 15 seconds of
continuous attempts to start. If the engine fails
to start, please allow the generator to cool for
at least 1 minute before your next attempt.
Failure to do this will damage the starter motor
and may void warranty.
• If the generator idles for a long period of time
due to other improper use/ other factors; the
lithium battery will be undercharged and so the
generator cannot be electrically started. Follow
the manual start steps to control the choke and
to start the generator manually. The generator
will automatically charge the lithium battery
during operation.
5. WIRELESS REMOTE CONTROL
(IF APPLICABLE)
Press and hold the “ON” key for 1 second
and release it to start the generator.
If it fails to start, the generator will restart
by itself. If it fails to start after repeated
5 times, please allow the generator to
cool for 1 minute and start again.
IMPORTANT
• Sometimes the generator can take a few
attempts to start in cold weather. If machine
does not start in the rst 10 seconds, wait for
30 seconds before attempting again.
• If the motor turns a little then stops when
you press the Start key, it may indicate a low
battery. Charge the battery before operation or
start by recoil start.
WARNING
The starting remote controls come from the factory
pre-set, users do not need to link to the generator
when rst used. If you need to link (pair) the remote
transmitter, press and hold the start button for
5seconds and release, then press the “ON” button
for 1second. If the generator starts, the remote
transmitter is successfully paired.

12 A STEELFORT PRODUCT | STEELFORT.CO.NZ
When electrical device requires a large starting
current, please put the energy-saving switch in the
“OFF” position; When the starting current required
by electrical device is small, put the energy-saving
switch in the “ON” position.
After completing the operations above, the generator
can be connected to electrical devices.
WARNING
It is prohibited to start or close the generating
set when the output terminal of generating set is
connected to an electric device and the electric
device is in “ON” state.
V. CONNECT TO ELECTRICAL
DEVICES
Inspect power cord for damage before using. A
hazard is electrical shocks from crushing, cutting or
heat damage.
1. Allow the engine to stabilise and warm up for a
few minutes after starting.
2. Make sure the electrical devices are in “OFF”
position and the load current is not higher
than the maximum withstanding current of the
single socket
DANGER
If connected devices overheat, turn them off and
disconnect them from generating set.
ELECTRICAL SHOCK
• To reduce the risk of electrical shock, DO NOT
use electrical cords that are worn, frayed, bare
or otherwise damaged.
• DO NOT touch bare wires or receptacles.
• DO NOT handle generator or electrical cords
while standing in water, while barefoot, or while
hands or feet are wet.
LOADING CAPACITY
You must make sure your generator can supply
enough rated (running) and surge (starting) watts for
the electrical devices you plan to power at the same
time. Follow these simple steps to calculate the
running and starting watts that are necessary for
your purposes.
WARNING
• DO NOT overload the generator.
• Exceeding the generator’s capacity can
damage the generator and/or electrical devices
connected to it. Faults and damaged caused by
overloading may void warranty.
1. Select the electrical devices you will power at
the same time.
2. The amount of power you need to run all the
devices is the total rated (running) watts of
these items.
3. Identify how many surge (starting) watts you
will need. Surge wattage is the short burst of
power needed to start electric power tools and
or appliances. Because not all motors start at
the same time, total surge watts can
be estimated by adding only the electrical
device(s) with the highest additional surge
watts to the total rated watts from step 2.
When the generator is being used as a back up power
supply for a building, you are required to have an
isolating switch installed by a qualied electrician.
This is to ensure the generator is not connected
to the main electrical grid. Failure to isolate the
generator from the electrical grid may result in injury
or death to electrical utility workers, or damage to
the generator due to the back feed of electrical
current.

13
A STEELFORT PRODUCT | STEELFORT.CO.NZ
WATTAGE REFERENCE CHART
VI. STOPPING THE ENGINE
1. Remove the connectors of all electric
equipment from the generating set panel.
2. Turn the combination switch to the “stop”
position, the generator stops operation
WARNING
NEVER stop the engine with electrical devices
connected and with the connected devices turned
“ON”.
WIRELESS REMOTE CONTROL
(IF APPLICABLE)
• Press and hold the “OFF” button for at least
0.3 seconds to stop the generator. After the
generator stops , turn the combination switch
to the “stop” position.
• When the control distance is shortened or the
indicator light is on but the remote control
function is not available, Wireless remote
replace the battery. Contact your local dealer
for more information.
ONE BUTTON START-STOP
(IF APPLICABLE)
• Press the start-stop button to turn off the
generator. After the generator shutdown, turn
the combination switch to “stop” position.
WARNING
If the generator will not be used for a long time,
please turn the combination switch to the “off’’
position. After the fuel in the carburetor bowl runs
out and the generator automatically shuts down, turn
the knob to the “stop” position. If the combination
switch knob is not turned to the “stop” position,
there is a risk of fuel leakage. And the battery will be
undercharged after a long time placed, resulting in
failure to start the generator.
3. For some applicable models, after the
generator stops and cools down, turn the fuel
tank cap ventilation knob to “OFF” position.

14 A STEELFORT PRODUCT | STEELFORT.CO.NZ
VII. PARALLEL OPERATION
Only applicable to some models.
Make sure that the generator is in a good running
state before connecting it to other similar generator
units. The total power of electric devices should not
exceed rated power of the generator.
When the electric motor starts, the overload indicator
(red) will light up and will normally stop within 4
seconds. If it doesn’t go out, please consult your
Service Dealer.
During parallel operation, energy-saving switches of
generator should be in the same position.
1. Connecting one generator to other generator
set(s) in parallel. Use the parallel kit to make
the parallel connection (the parallel kit needs to
be purchased separately).
2. Start the engine in proper order and make sure
that the running indicator (green) is normal.
3. Connect the plug of electric devices to the AC
receptacle of parallel kit.
4. Run the electrical devices.
VIII. MAINTENANCE
It is the operator’s responsibility to complete all
scheduled maintenance and or servicing in a timely
manner. Always correct any issues before operating
the generator. Follow all inspection and
maintenance recommendations that are listed in the
manual.
WARNING
Improper maintenance and or failure to correct
problems prior to operating the unit may cause the
unit to malfunction and result in property damage
and or serious personal injury. Improper maintenance
and servicing may void warranty.
DANGER
Accidental starts can cause serious personal injury.
Remove and ground the spark plug wire before
performing any service.
CAUTION
The lter element may contain PAHs, PAHs that
is harmful for your health. Please wear gloves for
protection during air lter maintenance.

15
A STEELFORT PRODUCT | STEELFORT.CO.NZ
1. MAINTENANCE SCHEDULE
Before servicing the generator, stop the
generator, disconnect all electric devices and battery
(if equipped) and allow the generator to cool down.
Follow the service intervals indicated in the chart
below. Service your generator more frequently when
operating in adverse conditions. Contact your local
Service Dealer if the generator requires maintenance.
Note 1: Applicable types (if available).
Note 2: Before each season and after (whichever comes rst).
Note 3: Service more frequently under severe, dusty, dirty conditions.
Note 4: To be performed by knowledgeable and or experienced owners. However, we recommend using an
authorised service agent to conduct all maintenance and servicing need for the purpose of voiding issues with
warranty.

16 A STEELFORT PRODUCT | STEELFORT.CO.NZ
2. GENERATOR MAINTENANCE
• Make certain that the generator is kept clean
and stored properly.
• Use a damp cloth to clean exterior surfaces of
the generator.
• Use an compressed air (25 PSI) to clear dirt
and debris from the generator.
• Inspect all air vents and cooling slots to ensure
that they are clean and unobstructed.
WARNING
• DO NOT use water to clean the generator. Water
can enter the generator through the cooling
slots and damage the generator windings.
• DO NOT modify the generator in any way.
• DO NOT tamper with governed speed.
Generator supplies correct rated frequency and
voltage when running at factory set.
• Tampering with the factory reset governor will
void your warranty
3. ENGINE MAINTENANCE
3.1 ENGINE OIL
LawnMaster 10W30 Oil (PP01020005) is
recommended. Other viscosities shown in the chart
may be used when the average temperature in your
area is within the indicated range. OIL MUST BE
PLACED IN ENGINE BEFORE STARTING.
Ambient temperature
Oil capacity (rated):
See Parameters.
3.2 ADDING OIL
1. Place the engine on a level surface.
2. Remove the air lter maintenance cover and
dipstick and wipe it clean.
3. Add recommended oil to the upper limit.
4. Fully tighten the dipstick and reinstall the air
lter maintenance cover.

17
A STEELFORT PRODUCT | STEELFORT.CO.NZ
CAUTION
OIL LEVEL CHECK
Reinstall dipstick into tube; rest on oil ll neck,
DO NOT thread cap into tube.
• Dispose of used oil at an approved waste
management facility.
3.3 CHANGING OIL
CAUTION
Change the oil when in hot engine state. The oil can
reach up to 140 °C under that condition. Careful
operation should be taken to prevent burns.
1. Place the machine on a level surface which is
300mm higher than the ground.
2. Remove the air lter maintenance cover.
3. Remove the oil drain plug
4. Place the oil container box under the oil drain
hole of the generator and remove the drain bolt
to drain out all the used oil.
5. Fully tighten the drain bolt before reinstalling
the drain plug.
6. Add recommended oil to the upper limit.
7. Fully tighten the dipstick and install the air lter
maintenance cover back in place.
8. Properly dispose of any used oil at an approved
waste management facility.
WARNING
The engine is not lled with oil at the factory. Any
operation before it has been properly lled with the
recommended type and amount of oil may result in
engine damage and void your warranty.
4. AIR FILTER
1. Loosen the lter x bolt and remove the cover
of the air lter.
2. Remove the foam lter element.
3. Wash in liquid detergent and warm water
4. Squeeze thoroughly dry in a clean cloth.
5. Saturate in clean engine oil.
6. Squeeze in a clean, absorbent cloth to remove
all excess oil.
7. Place the lter in the assembly.
8. Fasten the air lter cover with the x bolt, and
the mounting it back to the air lter body.

18 A STEELFORT PRODUCT | STEELFORT.CO.NZ
WARNING
DO NOT run the engine without the air lter, or
serious danger can result.
5. SPARK PLUG
1. Clean any dirt from the spark plug cap and
spark plug base.
2. Remove the spark plug cap.
3. Using socket wrench to loose and remove the
spark plug.
4. Inspect the spark plug and spark plug washer,
if it’s damaged or worn, replace with new one.
Clean the spark plug with wire brush if reuse it.
5. Check spark plug gap. Carefully bend side
electrode to adjust the gap if necessary.
SPARK PLUG GAP: 0.6MM - 0.8MM
6. Carefully thread the plug into the engine by
hand.
7. After the spark plug is in position, use spark
plug wrench to tighten the plug.
SPARK PLUG TIGHTEN TORQUE: 15-20 N.M
8. Attach the spark cap to the plug and connect
the spark plug wire to the plug.
WARNING
Only use the recommended spark plug or equivalent.
DO NOT use spark plugs that have improper heat
range.
9. Install spark plug maintenance cover.
SPARK ARRESTER
(IF APPLICABLE)
1. Allow the generating set to cool completely
before servicing the spark arrester.
2. Remove the muer blind window rst.
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the
spark arrester screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Reinstall the spark arrester in the muer and
reinstall the muer blind window.

19
A STEELFORT PRODUCT | STEELFORT.CO.NZ
IX. STORAGE & TRANSPORTATION
STORAGE
The generating set should be started at least once
every 2 weeks and allowed to run for at least 20
minutes. Follow the instructions below for longer
term storage if the generating set will be out of
service for 2 months or more.
WARNING
FIRE OR EXPLOSION
Gasoline is highly ammable and extremely
explosive. Empty the fuel tank and shut off fuel valve
before storing or transporting this generating set.
1. Allow the generating set to cool completely
before storage.
2. Clean the generating set according to
instructions in Maintenance section.
3. Drain all fuel completely from the fuel tank,
fuel hose and carburetor to prevent gum from
forming.
4. Turn the combination switch in “STOP” position
to cut off the fuel.
5. Remove the oil drain plug to drain out the oil
6. Remove the spark plug and pour about 15 ml of
fresh oil into the cylinder. Pull the recoil starter
slightly to distribute the oil and lubricate the
cylinder. And then attach the spark plug.
7. Store the unit in a clean, dry area out of direct
sunlight.
8. Disconnect the battery.
TRANSPORTATION
When generator is being transported or put into short
term storage, the generator should be in the normal
operating position and xed vertically to prevent fuel
leakage. The combination switch should be in the
“stop” position and knob of the fuel cap should be
turned to the “OFF” position.
WARNING
When transporting do not overll the tank. Do not
operate the generating set while it is on vehicle.
Take the generating set off the vehicle and use it
in a well-ventilated place. Avoid a place exposed to
direct sunlight when putting the generating set on a
vehicle. If the generating set is left in an enclosed
vehicle for many hours, high temperature inside the
vehicle could cause fuel to vaporize resulting in a
possible explosion. Do not drive on a rough road for
an extended period with the generating set on board.
If you must transport the generating set on a rough
road, drain the fuel beforehand.

20 A STEELFORT PRODUCT | STEELFORT.CO.NZ
X. TROUBLE SHOOTING
This manual suits for next models
3
Table of contents
Other LawnMaster Portable Generator manuals
Popular Portable Generator manuals by other brands

BE Power Equipment
BE Power Equipment BE2800i Operator's manual

EcoPower
EcoPower CIPR-15Z NG/LP Installation and user instructions

WhisperPower
WhisperPower GV4 Piccolo installation manual

MQ Power
MQ Power DCA-150SSKII Parts and operation manual

Alpha Technologies
Alpha Technologies AlphaGen DCX2000 quick start guide

Champion
Champion 100520 Operator's manual