Leader Easy Pow'air MT236 Installation manual

US
ATTENTION: Dot not attempts to start the MT236 ventilator if you notice any kind of
anomaly. Contact Leader North America, Inc. immediately.
The following checks must be carried out before first starting the fan:
- Make a visual check of the MT236 and its accessories to make sure that no damage
occurred during transport.
- Check that the manual for the HONDA is contained in the pack.
With the engine off, pull the recoil starter. If there is any unusual noise, or if the turbine
gets stuck, stop the engine and contact Leader North America, Inc. immediately.
Read the instruction manual for the engine before filling up with oil or gasoline.
Use the fuel and lubricant recommended in the instruction manual for the engine: fresh,
unleaded gasoline with an octane rating of at least 85.
Fill the engine’s oil sump with a type of oil recommended in the instruction manual.
MT236 : engine HONDA: oil capacity: 0.16 Gallons (20W50)
The limits for oil use are shown in the HONDA engine manual.
Make sure that everyone responsible for or using this equipment is fully aware of the
safety and operating precautions pertaining to rotating machinery.
NOTICE: By its nature, a gasoline engine creates vibrations. It is normal for the fan to vibrate
when in use, particularly at medium power. To ensure better stability for the MT236 fan,
particularly on an uneven surface, put the accelerator up to maximum power. This will
reduce the vibrations and improve the equipment’s stability.
It is possible that there will be some extraneous vibration during the engine’s running-in
period. These will disappear after several hours’ use.
INSTRUCTIONS FOR START-UP :
START-UP OPERATIONS :
The way the MT236 fan is started depends on the terrain on which it is being used.
1/ Check that the fuel tank is full.
2/ Check that there is no fuel leakage.
3/ Place the MT236 fan on a flat surface where there are no slippery products and which is
clear of debris. Make sure there is no obstacle between the fan and the opening for air
entry.
4/ Start the fan after making sure that it is in a stable position, and adjust the accelerator so
as to obtain the desired airflow. (For more information, see the engine manufacturer’s
manual).
5/ During blowing operations, regularly check that no obstacle is preventing the airflow
from penetrating the interior of the building, or blocking the fan’s suction grill
Easy Pow’air MT236 : GENERAL FEATURES
Manufacturer’s reference I60.10.042 I60.10.057
Manufacturer Leader North America, Inc.
Construction :
 Chassis in ø 1.18 ” steel tube –epoxy coating
 Engine Honda GX160 type –4-stroke –4.8HP (5.5 HP SAEJ607)
Fan shroud in 0.1 “ sheet aluminium
Turbine made of composite resin - ø 16 “ –aluminium axle
Run time - 2h10m at full speed
Standard equipment : engine stops automatically in the event of shortage of oil or if the
fan is accidentally knocked over.
Noise level around 90.9 dB(A) at 118 ”.
Retractable handle, two 8” diameter wheels.
Angle of tilt adjustable (from 10° to 20°).
Airflow: 17.376 CFM
Guarantee:
3 years, parts and labour, for the engine, see manufacturer’s documentation
This equipment should be used only by firefighting professionals
ADJUSTING THE TILT:
Use between 6 to 12 feet from the opening
1) Lift the carrying handle, the fan is
automatically tilted to an angle of 10°
(operating angle recommended for 90% of
incidents).
2) To close the carrying handle,
unlock it using the index pin (ref. A).
ADJUSTING THE TILT: LANDING, ENTRY WITH STEPS,
WINDOW:
Use between 12 and 18 feet from the opening
1) To adjust the tilt between 10°
and 20°, unlock the tilt adjustment
lever by moving it a quarter turn.
2) Tilt the fan manually so as to
Center the jet of air on the opening.
3). Lock the lever while holding the
fan in place so as not to alter the tilt.
Option : -10% Tilt Positioning Adaptor
:
A
To tip
20°
10°
To unlock
To lock
Weight : 93 LBS
+/- 0.5 Kg
Weight : 93 lbs
+/- 1lbs
H=21.65’’ W=21.65’’
D=19.3’’
+/- .5’’
Only use 10° tilt on slope
- 10° Position
Handle
Rear
Protection
-10°
US
This equipment is manufactured in compliance with CE directives and ISO-9001. It should be
used only by fire-fighting professionals.
Read this manual completely, together with the attached instructions for the use and
maintenance of the engine before starting up or using the equipment.
Do not remove the gasoline tank cap, or fill the tank, while the engine is running or when it is
hot (let the engine cool down for 2 minutes before filling the gasoline tank).
Keep fingers and hands away from the turbine and the hot parts of the equipment
(cylinder block and exhaust).
Do not start up the engine when the air filter or the air filter cover are removed.
Always use recently produced unleaded gasoline. Gasoline which has been stored for a long
time forms a deposit which could block the carburettor.
Do not run the engine in an enclosed space. (The exhaust gases contain carbon monoxide.)
Do not fill the gasoline tank in an unventilated area.
This ventilator must be operated or repaired only by qualified, trained staff.
Do not start up the engine if the blades or the protective shroud show any signs of damage.
Never move the ventilator when it is running at full speed.
Only use genuine spare parts supplied by Leader North America, Inc. when replacing
damaged or defective parts.
During maintenance operations, the wire leading to the spark-plug should be removed and
fixed elsewhere.
MT236 type blowers must not be used in explosive atmospheres.
Do not remain in the fan’s outlet area (risk of flying debris).
Keep this equipment out of reach of children.
Wear safety glasses, gloves and earmuffs when using this ventilator.
Never allow anyone to use a ventilator without first giving them the necessary instructions.
Do not wear loose clothing which could get caught in the ventilator.
Do not use chocks or any other system for increasing the ventilator’s tilt angle.
Do not forget to put oil in the ventilator’s engine before use.
SAFETY INSTRUCTIONS :
PRECAUTIONS FOR USE :
NOTE : MT236 ventilators operate on the high-speed entrained air principle. These
portable ventilators are designed to clear smoke and gas, volatile or otherwise, by their
blowing (or positive power) action, in all types of premises where an exit has been prepared.
They are designed to be used between 6 to 18 feet away from the opening concerned.
Leader North American, Inc recommends that the minimum opening for escaping smoke
should be double or more than the size of the entry opening
This document has been drawn up in order to help you get to know how to use your
MT236 ventilator.
All operating and safety instructions must be strictly followed in order to avoid
accidents or problems. All operations involving dismantling or repair must be carried out
by Leader North America, Inc. or by an approved dealer.
This document demonstrates the ease of use and maintenance of the MT236 ventilator. If
you have any suggestions for improving this document, Leader North America, Inc. would
be very happy to hear them. Please do not hesitate to contact us.
R = 19.68 “
Code Notice :
MT236.0ZN.3.33.US.0

Other Leader Fan manuals

Leader Easy Pow'air MT240 Installation manual

Leader

Leader Easy Pow'air MT240 Installation manual

Leader EASY 2000 User manual

Leader

Leader EASY 2000 User manual

Leader B215L NEO User manual

Leader

Leader B215L NEO User manual

Leader NEO EVG230 User manual

Leader

Leader NEO EVG230 User manual

Leader EDS230 2HP User manual

Leader

Leader EDS230 2HP User manual

Leader EASY 4000 User manual

Leader

Leader EASY 4000 User manual

Leader ESP280 User manual

Leader

Leader ESP280 User manual

Popular Fan manuals by other brands

Broan LP80 installation guide

Broan

Broan LP80 installation guide

Soleus Air AIR602TF owner's manual

Soleus Air

Soleus Air AIR602TF owner's manual

GOVI polarik 7TN1 operating manual

GOVI

GOVI polarik 7TN1 operating manual

BV BV-WF-01 installation guide

BV

BV BV-WF-01 installation guide

cocweb CF-A-GR Installation and operation instruction

cocweb

cocweb CF-A-GR Installation and operation instruction

Hunter 28743 owner's manual

Hunter

Hunter 28743 owner's manual

Home Decorators Collection 34545-HBUN Use and care guide

Home Decorators Collection

Home Decorators Collection 34545-HBUN Use and care guide

Craftmade Pro Energy Saver 209 installation guide

Craftmade

Craftmade Pro Energy Saver 209 installation guide

B-Air Vent VP-50H instruction manual

B-Air

B-Air Vent VP-50H instruction manual

jablotron Futura installation manual

jablotron

jablotron Futura installation manual

Home Decorators Collection BANNERET Use and care guide

Home Decorators Collection

Home Decorators Collection BANNERET Use and care guide

Optimus F-4205 Instruction manual and owner's guide

Optimus

Optimus F-4205 Instruction manual and owner's guide

VMI CUBE manual

VMI

VMI CUBE manual

Fantech Fit 120H installation manual

Fantech

Fantech Fit 120H installation manual

DAY 73443 instruction manual

DAY

DAY 73443 instruction manual

Hunter Sonic Owner's guide and installation manual

Hunter

Hunter Sonic Owner's guide and installation manual

COMBAT HVE 400 Installation, operation and service manual

COMBAT

COMBAT HVE 400 Installation, operation and service manual

arcelik ARK 293 user manual

arcelik

arcelik ARK 293 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.