manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leader
  6. •
  7. Fan
  8. •
  9. Leader NEO EVG230 User manual

Leader NEO EVG230 User manual

EVG230 NEO.00.ZN03.42.US.0
WARNING: Do not attempt to start the ventilator if you notice any kind of anomaly.
Contact Leader North America immediately.
The following checks must be carried out before first starting the fan:
- Make a visual check of the ventilator and its accessories to make sure that no damage
occurred during transport.
- If there is any unusual noise, or if the impeller gets stuck, stop the engine and contact
Leader North America immediately.
- Make sure that everyone responsible for or using this equipment is fully aware of the safety
and operating precautions pertaining to rotating machinery.
INSTRUCTIONS FOR START-UP:
START-UP OPERATIONS:
The way the EVG230 NEO fan is started depends on the terrain on which it is being used.
Freely downloadable interactive ventilation courses at
www.leader.educexpert.com
1/ Place the ventilator on a flat surface where there are no slippery products and which is
clear of debris. Make sure there is no obstacle between the fan and the opening for air entry.
2/ Start the fan after making sure that it is in a stable position.
3/ During blowing operations, regularly check that no obstacle is preventing the airflow from
penetrating the interior of the building, or blocking the fan’s suction grill.
USING :
ADJUSTING THE TILT:
Use between 6 and 20 feet from the opening
1) Lift the carrying handle, the fan
is automatically tilted to an angle of
10° (operating angle recommended
for 90% of incidents).
2) To close the carrying handle,
unlock it using the index pin (ref. A).
ADJUSTING THE TILT: LANDING, ENTRY WITH STEPS,
OR WINDOW:
Use between 12 and 20 feet from the opening
1) To adjust the tilt between 10°
and 20°, unlock the tilt adjustment
lever by moving it a quarter turn.
2) Tilt the fan manually so as to
center the jet on the opening.
3). Lock the lever while holding the
fan in place so as not to alter the tilt.
EVG230 NEO : GENERAL FEATURES
Manufacturer’s reference I63.10.042N
Manufacturer LEADER SAS, Octeville sur mer - FRANCE
Warranty: 6 years, parts and labour, wear parts excluded
2 years for electric motor
This equipment is designed and manufactured in FRANCE.
This equipment should be used only by firefighting professionals
Construction:
1.1KW (1.5hp) 115V±10% - 50/60 Hz- motor TEFC
Operates on15 amp circuit breaker with up to 200ft of 10awg wire
GFCI compatible
Nominal maximum current required: 13.9 amps
A high-tech composite grid
Impeller made of composite resin - ø 16.5” – aluminium hub
Noise level +/- 85.2 dB(A) at 10ft
UL motor certification
Retractable handle
Angle of tilt adjustable (from 10° to 20°).
Airflow 17010cfm
Warning: Always keep your hands away from moving parts.
Before starting:
Regardless the power supply (whether it be mains or generator) make
certain that the necessary energy is present and stable in tension and
frequency (Nominal +/-10%) before plugging the device.
1. Use wiring strengths which are compatible with the installed capacity.
2. Place the EVG230 NEO fan on a flat surface with no slippery products or debris, and
make sure that there is no obstacle between the fan and the opening for air entry.
Starting the motor:
1. Start the fan after making sure that it is in a stable position.
2. Switch the potentiometer on the ▌position to start the fan.
3. Adjust the potentiometer on the power prefered from 0 à 100%.
Stopping the motor:
1. Move the potentiometer on the o position.
-For security reasons, in case of a power cute, the unit does not start off
automatically. To restart the potentiometer should be returned to o.
USE WITH PORTABLE GENERATING SETS:
Electric motors require a high level of power to start up. If the EVG230 NEO ventilator is
used with a portable generating set, Leader North America. recommends that a minimum
power level of 3kVA should be available.
490
558
To tip
20°
10°
To unlock
To lock
Weight : 78.3 lbs
+/- 1lbs
A
US
H=21.96’’ W=21.65’’
D=19.29’’
+/- .5’’
EVG230 NEO.00.ZN03.42.US.0
This document has been drawn up in order to help you get to know how to use your
ventilator.
All operating and safety instructions must be strictly followed in order to avoid accidents
or problems. All operations involving dismantling or repair must be carried out by Leader
North America, or by an approved dealer.
This document demonstrates the ease of use and maintenance of the ventilator. If you
have any suggestions for improving this document, Leader North America would be
very happy to hear them. Please do not hesitate to contact us.
This equipment should be used only by fire-fighting professionals.
Read this manual completely, together with the attached instructions for the use and
maintenance of the engine before starting up or using the equipment.
Keep fingers and hands away from the impeller and the hot parts of the equipment.
This ventilator must be operated or repaired only by qualified, trained staff.
Do not start up the engine if the blades or the protective shroud show any signs of damage.
Never move the ventilator when it is running at full speed.
Only use genuine spare parts supplied by Leader North America when replacing defective
parts.
During maintenance operations, the wire leading to the spark-plug should be removed and
fixed elsewhere.
EVG ventilator must not be used in explosive atmospheres.
Do not remain in the fan’s outlet area (risk of flying debris).
Keep this equipment out of reach of children.
Wear safety glasses, gloves and earmuffs when using this ventilator.
Never allow anyone to use a ventilator without first giving them the necessary instructions.
Do not wear loose clothing which could get caught in the ventilator.
Do not use chocks or any other system for increasing the ventilator’s tilt angle.
SAFETY INSTRUCTIONS :
PRECAUTIONS FOR USE:
NB: This ventilator operates on the high-speed entrained air principle. These portable
ventilators are designed to clear smoke and gas, volatile or otherwise, by their blowing (or
positive power) action, in all types of premises where an exit has been prepared. They are
designed to be used between 6 to 20 feet away from the opening concerned.
Leader North America recommends that the minimum opening for escaping smoke
should be the same size as the entry opening: the ideal would be double the size.
High expansion foam adapter without coupling
I60.20.105
5m ventilation duct
I60.20.101
Protective cover
I60.20.017
Prop for -10° tilt, useful for ventilating semi-
basements
I60.20.130
5m diam. duct 400mm for V-BOX
extractor/blower kit
I63.20.014
V-BOX cube for extractor/blower kit
I63.20.017
US
Translation of original user’s
guide
Area without
gravel / waste
Optional accessories:
Identification:
Designation
Reference
Serial
Number
Contact
Date of
manufacture

This manual suits for next models

1

Other Leader Fan manuals

Leader Easy Pow'air MT240 Installation manual

Leader

Leader Easy Pow'air MT240 Installation manual

Leader ESP280 User manual

Leader

Leader ESP280 User manual

Leader B215L NEO User manual

Leader

Leader B215L NEO User manual

Leader EASY 2000 User manual

Leader

Leader EASY 2000 User manual

Leader EDS230 2HP User manual

Leader

Leader EDS230 2HP User manual

Leader EASY 4000 User manual

Leader

Leader EASY 4000 User manual

Leader Easy Pow'air MT236 Installation manual

Leader

Leader Easy Pow'air MT236 Installation manual

Popular Fan manuals by other brands

Aria QBV100 owner's manual

Aria

Aria QBV100 owner's manual

Kichler Lighting 35155 manual

Kichler Lighting

Kichler Lighting 35155 manual

Hinkley NEO 905452FMW-LDD instruction manual

Hinkley

Hinkley NEO 905452FMW-LDD instruction manual

BMI Schiedel RITE-VENT ICID PLUS installation instructions

BMI

BMI Schiedel RITE-VENT ICID PLUS installation instructions

Airworks 29TFOM owner's manual

Airworks

Airworks 29TFOM owner's manual

Kichler Lighting Botella instruction manual

Kichler Lighting

Kichler Lighting Botella instruction manual

Global 246340 instruction manual

Global

Global 246340 instruction manual

Samaire SA493 instruction manual

Samaire

Samaire SA493 instruction manual

Field Controls 46284600 manual

Field Controls

Field Controls 46284600 manual

AIGOSTAR 718356204934 instruction manual

AIGOSTAR

AIGOSTAR 718356204934 instruction manual

Morris MFS-162226 instruction manual

Morris

Morris MFS-162226 instruction manual

AC Infinity CLOUDLINE user manual

AC Infinity

AC Infinity CLOUDLINE user manual

Ortech OIF6-260 manual

Ortech

Ortech OIF6-260 manual

RP LIGHTING 1070W installation guide

RP LIGHTING

RP LIGHTING 1070W installation guide

Black & Decker BXFP51006GB manual

Black & Decker

Black & Decker BXFP51006GB manual

Kenmore 405.34036310 Use & care guide

Kenmore

Kenmore 405.34036310 Use & care guide

NuTone QTREN110FLT manual

NuTone

NuTone QTREN110FLT manual

Kooper 2160663 User instructions

Kooper

Kooper 2160663 User instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.