Ledj 150W COB RGBA Par User manual

Order code: LEDJ375
150W COB CW/WW Par
User Manual

www.prolight.co.uk 150W COB CW/WW Par User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.

www.prolight.co.uk 150W COB CW/WW Par User Manual 3
0m 2m 3m 4m 5m1m
3180
1888
1310
12700
7560
5240
1410
840
582
795
472
328
509
302
210
4717
2812
1943
18900
11200
7760
2100
1250
862
1180
703
485
755
450
310
80° - Lux
FULL ON
CW
WW
50° - Lux
FULL ON
CW
WW
40° - Lux
FULL ON
CW
WW
5864
3497
2436
23400
14000
9760
2600
1560
1080
1470
875
610
938
560
390
25° - Lux
FULL ON
CW
WW
7312
4420
3078
29200
17700
12300
3250
1960
1370
1830
1110
770
1170
707
493
50 8040°25° ° °
Product overview & technical specications
TheLEDJ150WCOBCW/WWParusesaCOBLEDtoproduceahighoutputwashwithsmoothcolourmixingand
nocolourshadows.Theyfeaturean80°beamangleandalsocomesuppliedwiththreebeamreductionlenses
(25°,40°and50°)whichareeasilyinterchangeable.The4-buttonDMXdisplayallowsaccessofbuilt-incolour
macros,4selectabledimmercurves,0-100%electronicdimmingandselectionsofstand-aloneandDMXmodes.
150W COB CW/WW Par
257mm 320mm
353mm
•1x150Wcoolwhiteandwarmwhite
COBLED(CW/WW)
•Beamangle:80°native,25°,40°
and50°beamreductionlenses
supplied
•80°-3,180Lux@2m(fullon)
•5kHzrefreshrate
•DMXchannels:2/3/4or6selectable
•Autoandmaster/slavemodes
plusbuilt-inprograms
•0-100%dimmingand
variablestrobe
•Suppliedwithhangingbracket
•4pushbuttonmenuwithLEDdisplay
•PowerCONinput/output
•5-PinXLRinput/output
•3-PinXLRinput/output
•Fancooled
Specications 150W COB CW/WW Par
Powerconsumption 155W
Powersupply 100~240V,50/60Hz
Fuse T3A250V
Dimensions 353x257x320mm
Weight 4.4kg
Ordercode LEDJ375

www.prolight.co.uk 150W COB CW/WW Par User Manual 4
Technical specications
01-Earthpoint
02-Safetyeye
03-LEDdisplay
04-Functionbuttons
05-3-PinDMXinput
06-3-PinDMXoutput
07-5-PinDMXinput
08-5-PinDMXoutput
09-PowerCONinput
10-PowerCONoutput
11-FuseT3A250V
12-Hangingbracket
13-Hangingbracketadjustableknob
Inthebox:1 x xture,
1 x 25° beam reduction lens,
1 x 40° beam reduction lens,
1 x 50° beam reduction lens,
1 x power cable
& 1 x user manual
5-PIN DMX INPUT 5-PIN DMX OUTPUT
3-PIN DMX INPUT 3-PIN DMX OUTPUT
FUSE:
T3A 250V
POWER INPUT:
100-240V~50/60Hz
POWER OUTPUT:
100-240V~50/60Hz
MENU UPENTER DOWN
150W COB CW/WW Par
www.prolight.co.uk
12
09
13
05
11 07 0801 02
04
03
13
12
10
06

www.prolight.co.uk 150W COB CW/WW Par User Manual 5
Operating instructions
MENU
S L A u
Slave mode
d o n
don
d o F F
Display backlight
S t n d
rEv
Display inverse
d E F A
Reset factory settings
h. 0 0 0
h. 2 5 5
C. 0 0 0
C. 2 5 5
F5.00
F5.15
Manual dimming
mode
h. 2 5 5
C L 0 0
C L 0 8
F 5. 0 0
F 5. 1 5
Static colour mode
C L 0 0
Ch02
d. 0 0 1
d. 5 1 2
C h 0 3
C h 0 4
dr-1
dr-4
DMX settings/
dimmer curves
d. 0 0 1
Ch06

www.prolight.co.uk 150W COB CW/WW Par User Manual 6
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestexibilitywhenitcomes
tocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitof
thextureandeachxtureindependently.
ToaccesstheDMXaddressmode,pressthe“MENU”buttonontherearoftheunittoshowd.001on
theLEDdisplay.Nowusethe“UP”and“DOWN”buttonstosettherequiredDMXaddress.Pressthe
“ENTER”buttontoconrmthesetting. TheDMXchannelmodewillnowbedisplayed,usethe“UP”and
“DOWN”buttonsontherearoftheunittoselecteither2/3/4or6DMXchannelmode.
Pressthe“ENTER”buttontoconrmthesetting.Thedimmingcurvesettingswillnowbedisplayed,use
the“UP”and“DOWN”buttonsontherearoftheunittoselectbetweendr-1~dr-4.
Pressthe“ENTER” buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Operating instructions
Channel Value Function
1 000-255 CoolWhitedimmer(0-100%)
2000-255 WarmWhitedimmer(0-100%)
2 channel mode:
Channel Value Function
1 000-255 CoolWhitedimmer(0-100%)
2000-255 WarmWhitedimmer(0-100%)
3000-020 Linear(dimmingcurve)
021-040 SquareLaw(dimmingcurve)
041-060 InverseSquareLaw(dimmingcurve)
061-080 S-Curve(dimmingcurve)
081-255 Defaultdimmingcurve(setviamenu)
3 channel mode:
Channel Value Function
1 000-255 CoolWhitedimmer(0-100%)
2000-255 WarmWhitedimmer(0-100%)
3000-255 Masterdimmer(0-100%)
4 000-020 Linear(dimmingcurve)
021-040 SquareLaw(dimmingcurve)
041-060 InverseSquareLaw(dimmingcurve)
061-080 S-Curve(dimmingcurve)
081-255 Defaultdimmingcurve(setviamenu)
4 channel mode:
Channel Value Function
1 000-255 CoolWhitedimmer(0-100%)
2000-255 WarmWhitedimmer(0-100%)
3000 Nofunction
001-255 Variablewhite(3200K-6400K)
4 000-015 Nofunction
016-255 Strobe(slow-fast)
5 000-255 Masterdimmer(0-100%)
6 000-020 Linear(dimmingcurve)
021-040 SquareLaw(dimmingcurve)
041-060 InverseSquareLaw(dimmingcurve)
061-080 S-Curve(dimmingcurve)
081-255 Defaultdimmingcurve(setviamenu)
6 channel mode:
dr-3-InverseSquareLaw dr-4-S-curvedr-1-Linear dr-2-SquareLaw

www.prolight.co.uk 150W COB CW/WW Par User Manual 7
Operating instructions
Master/slave mode:
Tosetthemasterunit,pressthe“MENU”buttonontherearofthemasterunitthenselectyour
desiredprogram(soundactiveordimmermodes).Tosettheotherunitsinslavemode,pressthe
“MENU”buttonontherearoftheunittoshowSLAuontheLEDdisplayandpressthe“ENTER”
buttontoconrmthesetting.Theunitswillnowruninsequencewiththemasterunit.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.
Manual dimming mode:
Toaccessthemanualdimmingmode,pressthe“MENU”buttonuntilthedisplayshowsh.255onthe
LEDdisplay.Usethe“UP”and“DOWN”buttonstoselecttherequiredbrightnessofwarmwhitefrom
h.000~h.255.Pressthe“ENTER” buttonandthenusethe“UP”and“DOWN”buttonstoselectthe
requiredbrightnessofcoolwhitefromC.000~C.255.Toadjusttheashspeedpressthe“ENTER”
buttonandthenusethe“UP”and“DOWN”buttonstoselectanyvaluefromF5.00~F5.15.
Pressthe“ENTER” buttontoconrmthesetting.
Value: 000 - 255 (000 = low brightness, 255 = high brightness)
Value: 00 - 15 (00 = no ash, 15 = fast ash speed)
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Static colour:
Toaccessthestaticcolourmode,pressthe“MENU”buttonuntilthedisplayshowsCL00ontheLED
display.Usethe“UP”and“DOWN”buttonstoselecttherequiredstaticcolourfromCL00~CL08.
Toadjusttheashspeedpressthe“ENTER” buttonandthenusethe“UP”and“DOWN”buttonsto
selectanyvaluefromF5.00~F5.15.Pressthe“ENTER” buttontoconrmthesetting.
Value: 00 - 15 (00 = no ash, 15 = fast ash speed)
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Display backlight:
Toaccessthedisplaybacklightsetting,pressthe“MENU”buttonuntilthedisplayshowsdononthe
LEDdisplay.Usethe“UP”and“DOWN”buttonstoselecteitherdon(displaybacklighton)~doff
(displaybacklightoff).Pressthe“ENTER” buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Display inverse:
Toaccessthedisplayinversesetting,pressthe“MENU”buttonuntilthedisplayshowsdononthe
LEDdisplay.Pressthe“ENTER” buttontodisplayStndandusethe“UP”and“DOWN”buttonsto
selecteitherStnd(displaystandard)~ (displayinverse).
Pressthe“ENTER” buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
rEv

www.prolight.co.uk 150W COB CW/WW Par User Manual 8
Operating instructions
Reset factory settings:
Toresetthefactorysettings,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.
Pressthe“ENTER” buttontwicetodisplaydEFa.Pressthe“UP”and“DOWN”buttonstogether
andthexturewillberesettoitsfactorysettings.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

www.prolight.co.uk 150W COB CW/WW Par User Manual 9
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk 150W COB CW/WW Par User Manual 10
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk 150W COB CW/WW Par User Manual 11
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

www.prolight.co.uk 150W COB CW/WW Par User Manual 12
Other manuals for 150W COB RGBA Par
1
Table of contents