manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LEDone Distribution Inc
  6. •
  7. Floodlight
  8. •
  9. LEDone Distribution Inc LOD-KFL20W-**K User manual

LEDone Distribution Inc LOD-KFL20W-**K User manual

This manual suits for next models

2

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Phone: 1-510-770-1189 | Fax: 1-510-217-9461 | Web:www.ledonedistribution.com | E-mail: info-service@ledonedistribution.com
`
FLOOD LIGHT INSTALLATION INSTRUCTIONS
LOD-KFL20W-XXK LED FLOOD LIGHT FIXTURE
LOD-KFL30W-XXK LED FLOOD LIGHT FIXTURE
LOD-KFL50W-XXK LED FLOOD LIGHT FIXTURE
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
JUNCTION BOX MOUNTING
Mount to a weatherproof junction box and cover plate (not supplied) as shown. To ensure weatherproof seal, apply
weatherproof silicone sealant back of junction box. This is especially important with an uneven wall surface.
1. Thread fixture into Cover Plate. Seal arm thread using Teflon tape or silicone sealant.
2. Connect wires correctly.
3. Attach cover to Junction Box.
4. Aim floodlight in the direction desired and tighten locknut and Arm Screw.
Flood Screws
Junction
(not supplied)
Cover Plate
(not supplied)
Junction
(optional)
Cover
(optional)
Flood
Leveling Bubble
Knock Out Solts
Plug
Screws
Phone: 1-510-770-1189 | Fax: 1-510-217-9461 | Web:www.ledonedistribution.com | E-mail: info-service@ledonedistribution.com
`
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or
maintenance.
Trunnion Mounting
CAUTION: UL and C-UL listed or CSA certified liquid tight
cord grip suitable for use with three conductor type STW
flexible cord shall be used for connection to a wet location
outlet box provided by others.
To adjust the angle of the fixture using the trunnion:
1. Loosen the Pivot Bolts & angle locking screw.
2. Adjust fixture to desired angle.
3. Tighten Pivot Bolts & angle locking screw.
Ground Mounting
Mount to a Mighty Post as shown.
1. Thread fixture into Mighty Post Cap.
2. Connect wires correctly.
3. Place Mighty Post Cap on the Mighty Post.
4.Aim floodlight in the direction desired and tighten
locknut and Arm Screw.
WIRING
Universal voltage driver permits operation at 120V to
277VAC, 50 or 60 Hz except fixtures factory ordered with a
(PC)
1. Connect the black fixture lead to the (+) LINE supply
lead.
2. Connect the white fixture lead to the (-) COMMON
supply lead.
3. Connect the GROUND wire from fixture to supply ground
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to
Touch. Do not clean or maintain while fixture is Energized.
1. Clean lens & fixture with non-abrasive glass cleaning
solution.
2. Do not open fixture to clean the LED. Do not touch the
LED.
Fig.1 Without photocell
Fig2. With photocell
TROUBLESHOOTING
1. Check that the line voltage at fixture is correct. Refer
to wiring directions.
2. Is the fixture grounded properly?