Ledvance Area Light 5A User manual

4177724
Area Light 5A
The LEDVANCE Value Class Wattage
Selectable Area Flood 5A luminaires are
environmentally preferable LED
alternatives to traditional HID luminaires,
offering up to 78% in energy savings.
Ideal in place of traditional luminaires, or
in new installations, the Area Light 5A
series are wattage/lumen selectable for
use in parking lots, building facades, and
general area lighting.
LEDVANCE Luminaries
Value Class Wattage Selectable Area Flood
For warranty coverage, please register at www.ledvanceUS.com
WARNING
Please Read All Instructions Before Attempting Installation
• TO PREVENT PERSONAL INJURY OR PRODUCT DAMAGE ONLY LICENSED ELECTRICIANS SHOULD PROVIDE ALL
INSTALLATION SERVICES.
• TO AVOID ELECTRIC SHOCK OR COMPONENT DAMAGE DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OR
SERVICING.
• THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC) AND ALL
APPLICABLE FEDERAL, STATE AND LOCAL ELECTRIC CODES AND SAFETY STANDARDS.
• USE ONLY UL (OR OTHER NTRL) APPROVED WIRE FOR INPUT/OUTPUT CONNECTIONS. MINIMUM SIZE 18 AWG OR 14
AWG FOR CONTINUOUS RUNS.
• DO NOT INSTALL IN A HAZARDOUS ATMOSPHERE, EXCEPT WHERE THE AMBIENT TEMPERATURE DOES NOT EXCEED
THE RATED OPERATING TEMPERATURE OF THE FIXTURE.
• USE CAUTION WHEN HANDLING THIS PRODUCT DURING OR AFTER OPERATION AS IT MAY BECOME HOT AND CAUSE
BURNS. DISCONNECT PRODUCT AND ALLOW COOLING PRIOR TO SERVICING.
• ANY ALTERATION OR MODIFICATION OF THIS PRODUCT IS EXPRESSLY FORBIDDEN AS IT MAY CAUSE SERIOUS
PERSONAL INJURY, DEATH, PROPERTY DAMAGE AND/OR PRODUCT MALFUNCTION.
• TO PREVENT PRODUCT MALFUNCTION AND / OR ELECTRICAL SHOCK THIS PRODUCT MUST BE PROPERLY
GROUNDED.
• CAUTION -RISK OF FIRE
• THIS LUMINAIRE IS DESIGNED TO OPERATE IN AMBIENT TEMPERATURES RANGING FROM -40°F TO +122°F (-40°C TO
+50°C).

4177724
Safety Precautions:
IMPORTANT:
READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN FOR FUTURE REFERENCE.
GENERAL:
Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier.
Wattage Selection Switch
-Use a tool (screwdriver) to open the knockout on in the front of the luminaire and select the desired wattage. Then use a
tool (screwdriver) to replace and tighten knockout.
Trouble Shooting Checklist
•Check your power source.
•Check electrical connections

4177724
Universal Mounting Bracket:
*Comes fitted with slip fitter. Square and round pole mount in the box,
Pole Drill Pattern:

4177724
Installation: Slip fitter Mount
1. Attach the pole mount bracket/installation bar to the slip
fitter and screw down bolts until fully tightened.
1. Remove any spare parts from the bracket.
2. Loosen the four bolts on the bracket, connect the wires
correctly, and pull the wires into the pole. Place the bracket
into the pole and lock the four bolts. Note: Adjustable angle
range is 0-90°
Installation: Square Pole Mount
2. Thread the wires into the square pole, attach the bracket
to the square pole with bolts, connect the wires properly
and close the junction box once wiring is complete.

4177724
Installation: Photocell
Installation: Round Pole Mount
1. Attach the pole mount bracket/installation bar
to the slip fitter and screw down bolts until fully
tightened.
2. Thread the wires into the round pole, attach
the bracket to the round pole with bolts, connect
the wires properly and close the junction box
once wiring is complete.
1. When the photocell function is required, photocell should
be installed on the back of light;
When it’s not required, shorting cap should be installed on
the back of light.

4177724
Wiring Diagram
Installation: Motion Sensor
1. Unscrew the 1/2 plug; install the sensor in the socket.

4177724
Luminaire de grandes surfaces 5A
Les luminaires LEDVANCE pour grandes
surfaces à puissance sélectionnable et de classe
valeur 5A sont des alternatives DEL
écologiquement responsables par rapport aux
luminaires à DHI traditionnels et sont 78 % plus
écoénergétiques.
Parfaits pour remplacer les luminaires
traditionnels ou pour les nouvelles installations, la
série de luminaires pour grandes surfaces 5A est
sélectionnable en puissance/lumens et peut être
utilisée dans les stationnements, sur les façades
de bâtiments et pour l’éclairage général.
Luminaires LEDVANCE
Luminaire pour grandes surfaces à puissance
sélectionnable et de classe valeur
Pour la couverture de la garantie, veuillez vous inscrire à www.ledvanceUS.com.
Veuillez lire attentivement toutes les directives d’installation avant de tenter l'installation.
• POUR ÉVITER DES BLESSURES CORPORELLES OU DES DOMMAGES AU PRODUIT, SEULS DES ÉLECTRICIENS CERTIFIÉS
DOIVENT EFFECTUER TOUS LES TRAVAUX D'INSTALLATION
• AFIN D’ÉVITER DES CHOCS ÉLECTRIQUES OU DES DOMMAGES AUX COMPOSANTS, COUPER L'ALIMENTATION
ÉLECTRIQUE AVANT DE PROCÉDER À L'INSTALLATION OU À L'ENTRETIEN.
• CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN
LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS
• UTILISER EXCLUSIVEMENT DES FILS HOMOLOGUÉS UL (OU AUTRE NTRL) POUR LES RACCORDS D'ENTRÉE ET DE
SORTIE. TAILLE MINIMALE DE CALIBRE AMÉRICAIN 18 OU 14 POUR LES ENFILADES CONTINUES
• NE PAS INSTALLER DANS UNE ZONE DANGEREUSE, SAUF SI LA TEMPÉRATURE AMBIANTE NE DÉPASSE PAS LA
TEMPÉRATURE DE FONCTIONNEMENT NOMINALE DU LUMINAIRE.
• MANIPULER LE PRODUIT AVEC SOIN LORS OU APRÈS L’OPÉRATION CAR IL PEUT DEVENIR CHAUD ET CAUSER DES
BRÛLURES. DÉBRANCHER LE LUMINAIRE ET LE LAISSER REFROIDIR AVANT DE LE RÉPARER
• TOUTE MODIFICATION OU ALTÉRATION DE CE PRODUIT EST EXPRESSÉMENT INTERDITE CAR ELLE PEUT ENTRAÎNER
DES BLESSURES GRAVES, LA MORT, DES DOMMAGES MATÉRIELS ET/OU UN DYSFONCTIONNEMENT DU PRODUIT
• AFIN D'ÉVITER TOUT MAUVAIS FONCTIONNEMENT DU PRODUIT ET/OU CHOC ÉLECTRIQUE, CE PRODUIT DOIT ÊTRE
CORRECTEMENT MIS À LA TERRE
• ATTENTION –RISQUE D’INCENDIE
• CE LUMINAIRE EST CONÇU POUR FONCTIONNER DANS DES TEMPÉRATURES AMBIANTES DE -40°C À 50°C (-40°F À 122°F)
AVERTISSEMENT

4177724
Mesures de sécurité :
IMPORTANT :
VEUILLEZ LIRE ATTENTIVEMENT LES DIRECTIVES D’INSTALLATION AVANT L’INSTALLATION DE CE LUMINAIRE.
GARDER CES DIRECTIVES POUR RÉFÉRENCE FUTURE.
GÉNÉRAL :
Lors de la réception de l'appareil, vérifiez soigneusement qu'il n'y a pas de dommages causés durant le transport et si des dommages
sont constatés aviser le transporteur.
Interrupteur de sélection de puissance (W)
-Utiliser un outil (tournevis) pour ouvrir l’entrée défonçable située à l'avant du luminaire et sélectionner la puissance
désirée. Ensuite, utiliser un outil (tournevis) pour remettre en place et resserrer l'entrée défonçable.
Liste de vérification pour le dépannage
•Vérifier la source d’alimentation
•Vérifier les raccords électriques

4177724
Support de montage universel :
*Inclus avec le raccord lisse. Montage pour mât rond et carré compris dans la boîte
Gabarit de perçage des mâts :

4177724
Installation : montage sur raccord lisse
1. Fixer le support de montage/barre d’installation du mât
sur le raccord lisse et visser les écrous jusqu'à ce qu'ils
soient complètement serrés.
1. Retirer toutes les pièces de rechange du support.
2. Desserrer les quatre écrous du support, connecter les
fils correctement et tirer les fils dans le poteau. Placer le
support dans le mât et rattacher les quatre écrous.
Remarque : l'angle réglable est de 0 à 90°.
Installation : montage sur mât carré
2. Insérer les câbles dans le mât carré, y fixer le support à
l'aide des écrous, connecter les câbles correctement et
fermer la boîte de jonction une fois le câblage terminé.
Support
Câble
Luminaire
Écrou ajustable
Support AM
Écrou de verrouillage
Support
Capuchon de caoutchouc
Barre d’installation

4177724
Installation : cellule photoélectrique
Installation : montage sur mât rond
1. .Fixer le support de montage/barre
d’installation du mât sur le raccord lisse et
visser les écrous jusqu'à ce qu'ils soient
complètement serrés.
2. Insérer les câbles dans le mât rond, y fixer le
support à l'aide des écrous, connecter les
câbles correctement et fermer la boîte de
jonction une fois le câblage terminé.
1. Lorsque la fonction de cellule photoélectrique est
requise, la cellule photoélectrique doit être installée à
l'arrière du luminaire ; lorsqu'elle n'est pas requise, une
fiche mise en court-circuit doit être installée à l'arrière du
luminaire.
Fiche de mise en court-circuit
Cellule photoélectrique
Luminaire
Douille
Barre d’installation
Capuchon en caoutchouc
Mât rond
Adaptateur de mât
Support A et D

4177724
Schéma de câblage
Installation : détecteur de mouvement
1. Dévisser la fiche 1/2 ; installer le détecteur dans la douille.
LUMINAIRE
PILOTE DEL GRAD. –(rose)
GRAD. + (pourpre)
ALIMENTATION
(noir/brun)
NEUTRE
(blanc/bleu)
MISE-À-LA-TERRE
(vert/jaune vert)
Câble d'alimentation
0-10V c.c.
*Si applicable
ALIM.
N
M.-À-T.
GRAD. +
GRAD. -
Détecteur de
mouvement
Fiche 1/2
Détecteur à
infrarouge passif
Table of contents
Languages:
Other Ledvance Outdoor Light manuals

Ledvance
Ledvance 1906 PIPE FLOOR 250X1590 User manual

Ledvance
Ledvance SMART+ WIFI FLOOD User manual

Ledvance
Ledvance UPLIGHT 7017359 User manual

Ledvance
Ledvance SMART+ ZB OUTDOOR FLEX RGBW User manual

Ledvance
Ledvance SMART+ WIFI TABLE FRAME User manual

Ledvance
Ledvance SMART+ WIFI GLOBE CAMERA TRACE User manual

Ledvance
Ledvance VINTAGE 1906 BUBBLE TABLE User manual

Ledvance