Leica ComGate10 User manual

Leica ComGate10
User Manual
Version 3.0
English
Monitoring
Solutions

Leica ComGate10, Introduction 2
Introduction
Purchase Congratulations on the purchase of the Leica ComGate10.
This manual contains important safety directions as well as instructions for setting up
the product and operating it. Refer to "1 Safety Directions" for further information.
Read carefully through the User Manual before you switch on the product.
Keep for future reference!
Product Identifica-
tion
The model and serial number of your product are indicated on the type plate.
Always refer to this information when you need to contact your agency or Leica
Geosystems authorised service centre.
Available documen-
tation
Referto the following resources forall ComGate10 documentation/software:
• the Leica USB documentation card
• https://myworld.leica-geosystems.com
Trademarks • Windows is a registered trademark of Microsoft Corporation in the United States
and other countries
All other trademarks are the property of their respective owners.
Feedback Your feedback is important as we strive to improve the quality of our documentation.
We request you to make specific comments as to where you envisage scope for
improvement.
Please contact your local Leica Geosystems representative to transfer your sugges-
tions.
Leica Geosystems
Address Book
On the last page of this manual, you can find the address of Leica Geosystems head-
quarters. For a list of regional contacts, please visit
http://leica-geosystems.com/contact-us/sales_support.
Validity of this
manual
This manual applies to the ComGate10.
Name Description/Format
Leica
ComGate10
Quick Guide
Provides an overview of the product together with tech-
nical data and safety directions. Intended as a quick
reference guide.
Leica
ComGate10
User Manual
All instructions required in order to operate the product
to a basic level are contained in the User Manual.
Provides an overview of the product together with tech-
nical data and safety directions.
-

Leica ComGate10, Introduction 3
myWorld@Leica Geosystems (https://myworld.leica-geosystems.com) offers a
wide range of services, information and training material.
With direct access to myWorld, you are able to access all relevant services whenever
it is convenient for you.
Service Description
myProducts Add all products that you and your company own and explore your
world of Leica Geosystems: View detailed information on your prod-
ucts and update your products with the latest software and keep up-
to-date with the latest documentation.
myService View the current service status and full service history of your prod-
ucts in Leica Geosystems service centres. Access detailed informa-
tion on the services performed and download your latest calibration
certificates and service reports.
mySupport View the current service status and full service history of your prod-
ucts in Leica Geosystems service centres. Access detailed informa-
tion on the services performed and download your latest calibration
certificates and service reports.
myTraining Enhance your product knowledge with Leica Geosystems Campus -
Information, Knowledge, Training. Study the latest online training
material on your products and register for seminars or courses in
your country.
myTrustedSer-
vices
Add your subscriptions and manage users for Leica Geosystems
Trusted Services, the secure software services, that assist you to
optimise your workflow and increase your efficiency.

Leica ComGate10, Table of Contents 4
Table of Contents
In this manual ChapterPage
1 Safety Directions 5
1.1 General Introduction 5
1.2 Definition of Use 6
1.3 Limits of Use 6
1.4 Responsibilities 6
1.5 Hazards of Use 7
1.5.1 General 7
1.5.2 For the AC Power Supply 9
1.5.3 Repairing of Products 9
1.6 Electromagnetic Compatibility EMC 9
1.7 FCC Statement, Applicable in U.S. 11
1.8 ICES-003 Statement, Applicable in Canada 11
2 Description of the System 12
2.1 General 12
2.2 System Concept 12
2.2.1 Hardware Concept 12
2.2.2 Software Concept 13
2.2.3 Power Concept 14
2.3 ComGate10 and available accessories 14
2.4 System Components 15
2.4.1 ComGate10 15
2.4.2 Cables 16
3 Operation 20
3.1 Preparation 20
3.2 Power Supply 22
3.3 Configuration 22
3.4 Connections 25
3.5 Mounting 26
3.6 Sensor Connection and Setups 26
3.7 LED Indicators on ComGate10 33
4Care and Transport34
4.1 Transport 34
4.2 Storage 34
4.3 Cleaning and Drying 34
5 Technical Data 35
5.1 General Technical Data 35
5.2 Interfaces 36
5.3 Cables to Connect Leica Sensors and External Devices to the
ComGate10 39
5.4 Short Message Service (SMS) 42
5.5 Conformity to National Regulations 43
6 Software Licence Agreement 44

Leica ComGate10, Safety Directions 5
1 Safety Directions
1.1 General Introduction
Description The following directions enable the person responsible for the product, and the
person who actually uses the equipment, to anticipate and avoid operational hazards.
The person responsible for the product must ensure that all users understand these
directions and adhere to them.
About Warning
Messages
Warning messages are an essential part of the safety concept of the instrument. They
appear wherever hazards or hazardous situations can occur.
Warning messages...
• make the user alert about direct and indirect hazards concerning the use of the
product.
• contain general rules of behaviour.
For the users‘ safety, all safety instructions and safety messages shall be strictly
observed and followed! Therefore, the manual must always be available to all persons
performing any tasks described here.
DANGER, WARNING, CAUTION and NOTICE are standardised signal words for iden-
tifying levels of hazards and risks related to personal injury and property damage. For
your safety, it is important to read and fully understand the following table with the
different signal words and their definitions! Supplementary safety information
symbols may be placed within a warning message as well as supplementary text.
Type Description
DANGER Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING Indicates a potentially hazardous situation or an unintended
use which, if not avoided, could result in death or serious injury.
CAUTION Indicates a potentially hazardous situation or an unintended
use which, if not avoided, may result in minor or moderate
injury.
NOTICE Indicates a potentially hazardous situation or an unintended
use which, if not avoided, may result in appreciable material,
financial and environmental damage.
Important paragraphs which must be adhered to in practice as
they enable the product to be used in a technically correct and
efficient manner.

Leica ComGate10, Safety Directions 6
1.2 Definition of Use
Intended use • Computing with software.
• Data communication with external appliances.
Reasonably Fore-
seeable Misuse
• Use of the product without instruction.
• Use outside of the intended use and limits.
• Disabling safety systems.
• Removal of hazard notices.
• Opening the product using tools, for example screwdriver, unless this is permitted
for certain functions.
• Modification or conversion of the product.
• Use after misappropriation.
• Use of products with recognizable damages or defects.
• Use with accessories from other manufacturers without the prior explicit approval
of Leica Geosystems.
• Inadequate safeguards at the working site.
1.3 Limits of Use
Environment Suitable for use in an atmosphere appropriate for permanent human habitation: not
suitable for use in aggressive or explosive environments.
DANGER Local safety authorities and safety experts must be contacted before working in
hazardous areas, or close to electrical installations or similar situations by the person
in charge of the product.
Environment Suitable for use in dry environments only and not under adverse conditions.
1.4 Responsibilities
Manufacturerof
the product
Leica Geosystems AG, CH-9435 Heerbrugg, hereinafter referred to as Leica Geosys-
tems, is responsible for supplying the product, including the user manual and original
accessories, in a safe condition.
Person responsible
forthe product
The person responsible for the product has the following duties:
• To understand the safety instructions on the product and the instructions in the
user manual.
• To ensure that it is used in accordance with the instructions.
• To be familiar with local regulations relating to safety and accident prevention.
• To inform Leica Geosystems immediately if the product and the application
becomes unsafe.
• To ensure that the national laws, regulations and conditions for the operation of
the product are respected.

Leica ComGate10, Safety Directions 7
1.5 Hazards of Use
1.5.1 General
CAUTION If the accessories used with the product are not properly secured and the product is
subjected to mechanical shock, for example blows or falling, the product may be
damaged or people can sustain injury.
Precautions:
When setting up the product, make sure that the accessories are correctly adapted,
fitted, secured, and locked in position.
Avoid subjecting the product to mechanical stress.
DANGER If the product is used with accessories, for example on masts, staffs, poles, you may
increase the risk of being struck by lightning. Danger from high voltages also exists
near power lines. Lightning, voltage peaks, or the touching of power lines can cause
damage, injury and death.
Precautions:
• Do not use the product in a thunderstorm as you can increase the risk of being
struck by lightning.
• Be sure to remain at a safe distance from electrical installations. Do not use the
product directly under or close to power lines. If it is essential to work in such an
environment contact the safety authorities responsible for electrical installations
and follow their instructions.
• If the product has to be permanently mounted in an exposed location, it is advis-
able to provide a lightning conductor system. A suggestion on how to design a
lightning conductor for the product is given below. Always follow the regulations in
force in your country regarding grounding antennas and masts. These installations
must be carried out by an authorised specialist.
• To prevent damages due to indirect lightning strikes (voltage spikes) cables, for
example for antenna, power source or modem should be protected with appro-
priate protection elements, like a lightning arrester. These installations must be
carried out by an authorised specialist.
• If there is a risk of a thunderstorm, or if the equipment is to remain unused and
unattended for a long period, protect your product additionally by unplugging all
systems components and disconnecting all connecting cables and supply cables, for
example, instrument - antenna.
Lightning conduc-
tors
Suggestion for design of a lightning conductor for a GNSS system:
1) On non-metallic structures
Protection by air terminals is recommended. An air terminal is a pointed solid or
tubular rod of conducting material with proper mounting and connection to a
conductor. The position of four air terminals can be uniformly distributed around
the antenna at a distance equal to the height of the air terminal.
The air terminal diameter should be 12 mm for copper or 15 mm for aluminium. The
height of the air terminals should be 25 cm to 50 cm. All air terminals should be
connected to the down conductors. The diameter of the air terminal should be kept
to a minimum to reduce GNSS signal shading.
2) On metallic structures
Protection is as described for non-metallic structures, but the air terminals can be
connected directly to the conducting structure without the need for down conduc-
tors.

Leica ComGate10, Safety Directions 8
Airterminal
arrangement, plan
view
Grounding the
instrument/antenna
DANGER Short circuited terminals can overheat and cause injury or fire, for example if they
come in contact with wires, jewellery, keys, metallised paper or other metals.
Precautions:
Make sure that the terminals do not come into contact with metallic parts.
CAUTION During operation the external antennas produces electromagnetic radiation.
Precautions:
Be sure to remain at a radial distance of more than 0.4m from the external antennas
during the operation of the product.
WARNING Inadequate securing of the working site can lead to dangerous situations, for example
in traffic, on building sites and at industrial installations.
Precautions:
Always ensure that the working site is adequately secured. Adhere to the regulations
governing safety, accident prevention and road traffic.
WARNING If the product is improperly disposed of, the following can happen:
• If polymer parts are burnt, poisonous gases are produced which may impair health.
• By disposing of the product irresponsibly you may enable unauthorised persons to
use it in contravention of the regulations, exposing themselves and third parties to
the risk of severe injury and rendering the environment liable to contamination.
Precautions:
Product-specific treatment and waste management information can be received from
your Leica Geosystems distributor.
a) Antenna
b) Support structure
c) Air terminal
GS_039
a
b
c
a) Antenna
b) Lightning conductor array
c) Antenna/instrument connection
d) Metallic mast
e) Connection to earth
GS_040
e
d
c
a
b
The product must not be disposed with household waste.
Dispose of the product appropriately in accordance with the national
regulations in force in your country.
Always prevent access to the product by unauthorised personnel.

Leica ComGate10, Safety Directions 9
1.5.2 Forthe AC PowerSupply
DANGER Missing Ground Connection
If unit is not connected to ground, death or serious injury can occur.
Precautions:
Always ground power cable and power outlet to avoid electric shock.
DANGER Electric Shock
The product is not designed for use under wet and severe conditions. If unit becomes
wet it may cause you to receive an electric shock.
Precautions:
Use the product only in dry environments, for example in buildings or vehicles. Protect
the product against humidity. If the product becomes humid, it must not be used!
DANGER Electric Shock
Touching the wet power plug or cord may cause you to receive an electric shock.
Precautions:
Never touch the wet power plug or cord.
DANGER Fire, Malfunction and Electric Shock
Improper handling of the power plug or cord, for example mechanical damage or heat,
may cause fire, malfunction or cause you to receive an electric shock.
Precautions:
Handle power plug and cord with care.
1.5.3 Repairing of Products
WARNING Only Leica Geosystems authorised service centres are entitled to repair these prod-
ucts.
1.6 Electromagnetic Compatibility EMC
Description The term Electromagnetic Compatibility is taken to mean the capability of the product
to function smoothly in an environment where electromagnetic radiation and electro-
static discharges are present, and without causing electromagnetic disturbances to
other equipment.
WARNING Electromagnetic radiation can cause disturbances in other equipment.
Although the product meets the strict regulations and standards which are in force in
this respect, Leica Geosystems cannot completely exclude the possibility that other
equipment may be disturbed.

Leica ComGate10, Safety Directions 10
CAUTION There is a risk that disturbances may be caused in other equipment if the product is
used with accessories from other manufacturers, for example field computers,
personal computers or other electronic equipment, non-standard cables or external
batteries.
Precautions:
Use only the equipment and accessories recommended by Leica Geosystems. When
combined with the product, they meet the strict requirements stipulated by the guide-
lines and standards. When using computers or other electronic equipment, pay atten-
tion to the information about electromagnetic compatibility provided by the manufac-
turer.
CAUTION Disturbances caused by electromagnetic radiation can result in erroneous measure-
ments.
Although the product meets the strict regulations and standards which are in force in
this respect, Leica Geosystems cannot completely exclude the possibility that the
product may be disturbed by intense electromagnetic radiation, for example, near
radio transmitters, two-way radios or diesel generators.
Precautions:
Check the plausibility of results obtained under these conditions.
CAUTION If the product is operated with connecting cables attached at only one of their two
ends, for example external supply cables, interface cables, the permitted level of elec-
tromagnetic radiation may be exceeded and the correct functioning of other products
may be impaired.
Precautions:
While the product is in use, connecting cables, for example product to external battery,
product to computer, must be connected at both ends.
Radios ordigital
cellularphones
Use of product with radio or digital cellular phone devices:
WARNING Electromagnetic fields can cause disturbances in other equipment, in installations, in
medical devices, for example pacemakers or hearing aids and in aircraft. It can also
affect humans and animals.
Precautions:
Although the product meets the strict regulations and standards which are in force in
this respect, Leica Geosystems cannot completely exclude the possibility that other
equipment can be disturbed or that humans or animals can be affected.
• Do not operate the product with radio or digital cellular phone devices in the vicinity
of filling stations or chemical installations, or in other areas where an explosion
hazard exists.
• Do not operate the product with radio or digital cellular phone devices near to
medical equipment.
• Do not operate the product with radio or digital cellular phone devices in aircraft.

Leica ComGate10, Safety Directions 11
1.7 FCC Statement, Applicable in U.S.
WARNING
WARNING Changes or modifications not expressly approved by Leica Geosystems for compliance
could void the user's authority to operate the equipment.
Labelling
1.8 ICES-003 Statement, Applicable in Canada
WARNING This Class (B) digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe (B) est conforme à la norme NMB-003 du Canada.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interfer-
ence in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
006196_002
Model: COMGT10LWEU
Art.No.:853396
Leica Geosystems AG
CH-9435 Heerbrugg
This device complies with part 15 of the FCC Rules,
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference that may
cause undesired operations. Manufactured 20XX
Made in China
Input Voltage 12-48 V
Current 0.42 A max.
GSM 850/900/1800/1900 MHz
UMTS 850/900/1900/2100 MHz
LTE B1/B3/B7/B8/B20
WLAN 2.4 GHz
Serial No 123456789ABCD
IMEI 123456789ABCDE
WLAN MAC 123456789ABCD

Leica ComGate10, Description of the System 12
2 Description of the System
2.1 General
Leica M-Com series • The ComGate10 provides the communication from the sensors in the field to the
Internet by a mobile communication provider (GSM/UMTS/HSDPA/HSUPA/LTE
and/or WLAN).
• This product portfolio offers easy installation, reliable communication, connection
of multiple sensors and external devices and increased mobility for periodic or short
term monitoring systems.
Pre-conditions To use a ComGate10 the following items are essential and must be organised
locally prior to installation:
From your Mobile provider:
• A SIM card for the wireless router, that supports the connection from the Internet
to the wireless router by a public IP address, the Mobile Internet and the Short
Message Service (SMS).
• A GPRS/UMTS/LTE breakout number or a standard telephone number.
• If essential, a user name and a password.
• The knowledge about the Access Point Name.
• The knowledge about the Authentication method: Challenge Handshake Authenti-
cation Protocol (CHAP) or Password Authentication Protocol (PAP).
• The knowledge about the PPP (Point-to-Point Protocol) DNS query: Specification
whether a DNS request to the provider is made or not.
From Dynamic Network Services Inc. (www.dyndns.com):
A DynDNS Account with following details:
• A user name and a password.
• A host name, for example myComBox.dyndns.org.
• A server address, normally “members.dyndns.org” is used.
• A server port, normally 80 or 8245.
More hardware:
• A personal computer with a monitor, a keyboard, a PC-mouse and an Ethernet
cable, for example desktop PC or notebook, in order to configure the ComGate10.
• An isolated screwdriver size 0 in order to connect the sensor cables with the
ComGate10.
• Tools in order to mount the ComGate10.
2.2 System Concept
2.2.1 Hardware Concept
Description The ComGate10 can connect two sensors to the Internet/network.
Hardware features Internet connectivity provided by a wireless router.
• Multimode LTE, HSDPA, HSUPA, UMTS, EDGE, GPRS and GSM, LTE/WLAN
• Global connectivity with quadband
• 4G (800 (B20)/850/900/1800/1900/2100/2600 MHz)
• 3G (850/900/1900/2100 MHz)
• Quadband 2G (850/900/1800/1900 MHz)

Leica ComGate10, Description of the System 13
The ComGate10 supports WLAN connections:
The ComGate10 supports following sensor types:
• Leica Total Stations (TPS)
• Leica GPS/GNSS Systems
• Leica Nivel200
• Geotechnical sensors in combination with Campbell Dataloggers
Ports:
• One RS232 serial port in order to connect the sensors
• One USB port in order to connect the sensors
• Two Ethernet ports:
– for the connection to the Internet by Ethernet cable
– for the connection of any other communication module
The Leica ComGate10 contains two coupling relays which can be switched digitally, for
example to connect warning devices like signal lamps or sirens. One of them can be
used to switch the instrument off and on automatically.
Accessory:
The antenna for the mobile Internet/WLAN connection can be purchased as an official
accessory.
2.2.2 Software Concept
Configuration The delivered ComGate10 is preconfigured.
Leica ComBox
Manager
The ComBox Manager software is required to configure the ComGate10. Use this
configuration tool to:
• Set the general settings of the ComGate10, for example name and type.
• Set the settings of the mobile provider, for example phone number, user name and
password.
• Set the DynDNS address on the wireless router.
• Set the port numbers and baud rates of diverse ports, for example ports COM1 to
COM2 or COM1 and USB.
Content of the Leica
M-Com USB card
Following elements can be found on the Leica M-Com ComBox/ComGate10 USB card:
• Software:
– Leica ComBox Manager
– Adobe Reader
• Manual
• TruStory
• Documentation
• Leica Website
Standard Frequencies [GHz] Bandwith [MHz] Net Data Rate
[MBit/s]
Range
Indoor/Outdoor [m]
802.11b 2.4 20 11 35/140
802.11g 2.4 20 54 38/140
802.11n 2.4 20 150 70/250

Leica ComGate10, Description of the System 14
2.2.3 PowerConcept
Description The Leica ComGate10 works in the low voltage range 12–48 V DC.
• In order to prevent hazards to an operator or other persons and damage to prop-
erty, follow the instructions in chapter "3 Operation" and be sure to observe the
precautions in chapter "1 Safety Directions".
• To ensure the correct functionality of the system use only the delivered structural
monitoring devices from Leica Geosystems and never disassemble or modify the
Leica M-Com series products without any advices from Leica Geosystems.
NOTICE Unplugging connecting cables from the ComGate10 during a continuous system causes
malfunctions.
2.3 ComGate10 and available accessories
Containerfordevice
and optional acces-
sories
Optional accessories for ComGate10 available:
*) Content of delivered card box
a) Power supply battery cable
b) Antenna for mobile internet (GSM/UMTS/HSDPA/HSUPA/LTE) and WLAN
c) Cable for communication and power supply to the instrument
d) Power supply cable
e) Power supply for mains voltage
f) ComGate10 with DIN mounting*)
g) Quick Start Guide*)
h) USB card manual*)
006176_002
a
b
e
f
h
d
c
g

Leica ComGate10, Description of the System 15
2.4 System Components
2.4.1 ComGate10
Main components
a) Terminal block
b) SIM card compartment
c) USB host connector for SmartWorx Viva
and Captivate instruments or another
sensor by the USB-serial converter
(RS232)
d) Ethernet switch for local network
e) Ethernet connector for connecting to
the Internet
f) Mini button to reset the ComGate10
g) Status LEDs
h) Connector for first UMTS/LTE antenna
i) Connector for second UMTS/LTE
antenna (MIMO mode)
j) Connector for first WLAN antenna
k) Connector for second WLAN antenna
(MIMO mode)
a) Label
b) Galvanic isolated digital outputs.
The outputs show the difference on
DO1 and DO2. DO2 is switched auto-
matically, if any TPS instrument is
connected by ComBox Manager. DO1
can be used for warning signals.
c) Serial RS232 interface
d) Power supply
e) Connection to the ground. The connec-
tion is required to ensure ESD compat-
ibility.
f) DIN rail mounting
014111_002
a
d
f
g
h
j
i
k
e
c
b
006178_003
a
b
c
d
e
f

Leica ComGate10, Description of the System 16
2.4.2 Cables
Description This chapter describes cables to connect Leica instruments and external devices to the
ComGate10.
All cables listed in this chapter are optional accessories.
All cables with a GEV-description can be ordered from Leica Geosystems.
Leica
TPS1000/TPS1100/
TPS1200 cable
Interface cable GEV241
Leica TM30/TS30
cable
Interface cable GEV240
a) Status LED
b) Mobile LED
c) VPN LED
d) WLAN LED
e) USB LED
006179_001
a
b
c
e
d
Cable features:
• Interface: ComGate10 - TPS instrument
• Transmission: Data and power
• Type: Shielded
• Length: 3 m
• Wires: 5
• Lemo pins: 5
• Unterminated
Cable features:
• Interface: ComGate10 - TM30/TS30
• Transmission: Data and power
• Type: Shielded
• Length: 5 m
• Wires: 8
• Lemo pins: 8
• Unterminated

Leica ComGate10, Description of the System 17
Leica MS60/TS60
MS50/TS50/TM50
instrument cable
Interface cable GEV271
Leica GMX910 cable Interface cable GEV212
Leica GMX902 cable Interface cable GEV247
Interface cable GEV160 + ATEN UC-232A
Leica Nivel210 cable Interface cable GEV207
Cable features:
• Interface: ComGate10 - MS50/TS50/TM50
• Transmission: Data and power
• Type: Shielded
• Length: 2 m
• Wires: 4 + USB
• Lemo pins: 8
• Unterminated
• USB standard plug type A
Cable features:
• Interface: ComGate10 - GMX910
• Transmission: Data and power
• Type: Shielded
• Length: 5 m
• Wires: 5
• Lemo pins: 8
• Unterminated
Cable features:
• Interface: ComGate10 - GMX902
• Transmission: Power
• Type: Shielded
• Length: 2 m
• Wires: 2
• Lemo pins: 2
• Unterminated
Cable features:
• Interface: USB-serial converter - GMX902
• Transmission: Data
• Type: Shielded
• Length: 2.8 m
• Wires: 5
• Lemo pins: 8
• RS232 connector
• This data cable must be connected directly to the D-Sub 9 connector of the ATEN
UC-232A adapter.
Cable features:
• Interface: ComGate10 - Nivel210
• Transmission: Data and power
• Type: Shielded
• Length: 1.8 m
• Wires: 5
• Lemo pins: 5
• Unterminated

Leica ComGate10, Description of the System 18
Leica Nivel220 cable Interface cable GEV207
DB9 cable (RS232) plus RS232/485 converter
Powersupply cable
TP meteo sensor
RS485
DB9 cable (RS232) plus RS232/485 converterplus USB-to-serial converter
Ethernet cable Ethernet cable RJ45
Cable features:
• Interface: RS232/485 converter - Nivel220
• Transmission: Data and power
• Type: Shielded
• Length: 1.8 m
• Wires: 5
• Lemo pins: 5
• Unterminated
Cable features:
• Interface: ComGate10 - RS232/485 converter
• Transmission: Data
• DB9 male to DB9 female
• Connect this cable directly to a serial port of the ComGate10 using USB-to-serial
converter (ATEN UC-232A).
• Leica Geosystems delivers no RS232 cable.
• Leica Geosystems delivers no USB-to-serial converter (ATEN UC-232A).
• Leica Geosystems delivers no RS232/485 converter. It is a product of ICP DAS Co.:
http://www.icpdas.com.
Cable features:
• Interface: ComGate10 - RS232/485 converter
• Transmission: Power
• This cable must be organised locally.
Cable features:
• Interface: ComGate10 - RS232/485 converter
• Transmission: Data
• DB9 male to DB9 female.
• Connect this data cable directly to a serial port of the ComGate10 using USB-to-
serial converter (ATEN UC-232A).
• Leica Geosystems delivers no RS232 cable.
• Leica Geosystems delivers no RS232/485 converter. It is a product of ICP DAS Co.
(http://www.icpdas.com).
• Leica Geosystems delivers no USB-to-serial converter (ATEN UC-232A).
Cable features:
• Interface: Ethernet Switch - Webcam
• Transmission: Data
• Max length: 100 m
• The optional, externally mounted webcam must be connected by an Ethernet cable.
• Leica Geosystems delivers no Ethernet cable.

Leica ComGate10, Description of the System 19
Warning device
cable
Warning device cable
Mobile internet/
WLAN antenna
cable
Antenna cable
For simultaneous use of mobile Internet and WLAN, two antennas of this type
are needed.
Powersupply cable Powercable
Cable features:
• Interface: ComGate10 - warning device
• Connect the optional warning devices directly by standard cables to the
ComGate10. The cables must be organised locally.
• Only an appropriately trained and qualified specialist may install warning devices
with a ComGate10.
• Refer to chapter "5 Technical Data" for information on the specifications of the
digital output or to section "3.6 Sensor Connection and Setups".
Cable features:
• Connectors: 2 × SMA male
• Length: 5.0 m
• The antenna is directly connected to the wireless router by the included antenna
cable.
Cable features:
• Interface: ComGate10 - power supply unit GEV270
• Transmission: Power
• Wires: 2
• Power supply unit (GEV270)

Leica ComGate10, Operation 20
3 Operation
Ensure to carry out all steps in this chapter in the described sequence.
3.1 Preparation
First steps
Set up DynDNS
account
To operate a ComGate10 over the Internet, a DynDNS account has to be available.
Refer to www.dyndns.com how to create an account.
The following information must be available:
• User name and password.
• Host name, for example myComBox.dyndns.org.
• Server address, normally members.dyndns.org.
• Server port, normally 80 or 8245.
Configuring
ComGate10 by
computer
Step Description
1. Open the card box.
2. Check that the items from the packing list are included.
Refer to section "2.3 ComGate10 and available accessories" for more
information.
3. Unpack the ComGate10.
Step Description
1. Connect a notebook or desktop PC with a network cable to the ComGate10.
The network cable must be plugged into the LAN port of the wireless
router.
2. Start the notebook or desktop PC.
The operating system must be Windows XP or higher.
006180_001
This manual suits for next models
1
Table of contents