2NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
These appliances are designed to operate
on natural or propane gas only.
Inputofappliancevariesfrom13,500to17,500
BTU/HR.
WARNING: THESE FIREPLACES ARE
VENTEDHEATERS. DONOTBURN WOOD
OR OTHER MATERIAL IN THESE APPLI-
ANCES.
CONGRATULATIONS!
In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the finest and most
dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a
wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX
Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your LENNOX product.
INTRODUCTION
The Fireplace models covered in this manual
are Direct-Vent sealed combustion gas fire-
place heaters designed for residential applica-
tion. Direct-Vent appliances operate with the
combustionchambercompletelyisolatedfrom
the inside atmosphere. All air for combustion
is brought in from the outside and exhaust
gases are vented through the same Direct
Vent, vent system.
The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation. External
electrical power is required to operate the
optional electrically powered components if
installed. Electrical power must be wired dur-
ing appliance installation.
These appliances comply with National Safety
StandardsandaretestedandlistedbyWarnock
Hersey (Report No. J20021557) to ANSI
Z21.88-2000(inCanada,CSA-2.33-2000),and
CAN/CGA-2.17-M91 in both USA and Canada,
as vented gas fireplace heaters.
Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
currentCAN/CGAB149installationcode.) Elec-
trical wiring must comply with local codes. In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
thecurrentCSAC22.1CanadianElectricCode.)
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATIONANDLISTINGSOFTHISUNIT.
TABLE OF CONTENTS
Introduction..................................... page 2
General Information......................... page 2
Operation/Care of Your Appliance ... page 3
Gas Controls.................................... page 3
Variable Flame Adjustment .............. page 4
Maintenance .................................... page 4
Control Compartment Access .......... page 4
Front Glass Enclosure Panel,
Removal and Installation ............... page 4
Maintenance Schedule..................... page 5
Burner Adjustments......................... page 6
Flame Appearance and Sooting ....... page 6
Adjustment ...................................... page 6
Log Placement................................. page 7
Glowing Embers Placement ............. page 7
Appliance Checkout ......................... page 7
Wiring Diagram ............................... page 7
Warranty.......................................... page 8
Replacement Parts .......................... page 8
Product Reference Information ....... page 8
Accessory Components ................... page 8
Troubleshooting Guide ..................... page 11
Lighting Instructions ....................... page 12
Replacement Parts List ..................... page 14
GENERAL INFORMATION
Note: Installation and repair should be per-
formedby aqualifiedservice person.The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
airpassage ways of the appliance be keptclean.
S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'appareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Duetohightemperatures the appliance should
be located out of traffic and away from furni-
ture and draperies. Locate furniture and win-
dow coverings accordingly.
Nominal operating pressures for the manifold
side of the gas control system are: 3.5 inches
water column (0.87 kPa).
Donotusethese appliances if anyparthasbeen
under water. Immediately call a qualified, pro-
fessional service technician to inspect the ap-
pliance and to replace any parts of the control
system and any gas control which have been
under water.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
ORPROPERTYDAMAGE. REFERTOTHIS
MANUAL. FOR ASSISTANCE OR ADDI-
TIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.
.oNledoM
ezisecifirO noitavelE
teeF
)sreteM(
larutaNenaporP
8233TDM
54# 840.0
hcni
0054-0
)0231(
8233RDM