TABLE OF CONTENTS
Shipping and Packing List 2...........................................
General 2...........................................................
Installing Control System Components 3................................
Mag-Mount Installation 3............................................
HD Display Installation 4............................................
Smart Hub Installation 4.............................................
Wiring for Control System Components 5...............................
Configuring Heat Sections on Air Handler Control 10......................
Smart Hub Operations 11.............................................
Smart Hub Indicators and Connectors 12..............................
Connecting Mobile Application to Smart Hub 13........................
Installer System Setup 14.............................................
Dealer Control Center 16..............................................
Equipment - System 17..............................................
Equipment - System 17.............................................
Equipment - Heat Pump 22..........................................
Equipment - Air Conditioner 24.......................................
Equipment - Air Handler 24..........................................
Equipment - Furnace 25.............................................
Equipment - Thermostat (HD Display) 26..............................
Equipment - Zoning Control 27.......................................
Equipment - Add / Remove Equipment 27.............................
Equipment - Reset All Equipment 27..................................
Notifications 28....................................................
Maintenance History 49.............................................
Tests 49...........................................................
Diagnostics 49.....................................................
Information 49.....................................................
System Configurations 50.............................................
Glossary 59.........................................................
FCC Compliance 60..................................................
Replacement Parts 60................................................
Index 61............................................................
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause
property damage, personal injury or loss of life. Installation and service must be
performed by a qualified installer, service agency or the gas supplier
SHIPPING AND PACKING LIST
1 - iComfort®S30 which includes:
> High definition (HD) wall mounted display interface with a Mag-Mount wall
base and optional use wall plate
> Smart Hub controller
4 - Mounting screws
4 - Wall anchors
1 - Installation and Setup and User Guides
1 - Warranty certificate
GENERAL
This iComfort®S30 is an electronic communicating, color display touchscreen and
7-day programmable interface which communicates directly with a Smart Hub. The
Smart Hub controller stores system parameters and settings in non-volatile
memory (i.e., retains data when electrical power fails or is turned off). After online
registration is completed, the system may then be accessed by the homeowner
from anywhere using a remote Internet connection via computer or personal
communicating device. This home environmental control system also supports:
SWireless bands 802.11b, 802.11g and 802.11n,
SLennox wireless point-to-point connection to other Lennox Smart Hubs in
home and other mobile devices running Lennox applications.
SThree languages are supported (English, Français and Español),
SAir conditioning or heat pump units with up to four stages of heat / two stages
of compressor operation (2 stages of heat pump heating, 2 stages of auxiliary
back-up heating, 2 stages of emergency heating),
SVariable - capacity / multiple - stage heat/cool, universal compatibility
(gas/electric/heat pump/air conditioner)
SDual-fuel capable (iComfort®heat pump only) with two balance points.
SIndoor air quality with time‐based notification of consumables including media
filters, UVC bulbs, humidifier pads, and PureAir system catalyst service /
replacement,
SiHarmony®zoning system (2 - 4 zones),
SLennox iComfort®Equipment Interface Module (Catalog number 10T50)
(connects the iComfort ®S30 to non-communicating indoor and outdoor units.
SHumidification measurement and control,
SDew point adjustment control,
SHumiditrol®Enhanced Dehumidification Accessory (EDA),
SEquipment maintenance reminders,
SHeat/Cool mode -- Permits control of heating, cooling, humidification, and
dehumidification without user involvement,
SAll Lennox branded iComfort®outdoor units have a outdoor temperature
sensor factory installed,
SEnhance defrost control options for Lennox communicating heat pumps using
Intellifrost Adaptive Defrost Control, part number 103369-04 or later.