3. Place the round holes of the Extender Brackets onto the ends of the long patch panel
mounting screws and secure the brackets with hex nuts (user-supplied).
2. Mount the Extender Brackets to rack or cabinet rail using long rack-mount screws and hex
nuts (screws and nuts are user- supplied).
3. Mount patch panel to the cage nuts using supplied rack-mount screws, or user-supplied
rack mount screws (if different size rack mount hardware is used for this installation).
Note: The Extender Brackets are NOT recommended for recessing angled patch panels, as the
jacks at either end of the angled panels would not be easily accessible to users.
4. Insert the rack-mount screws through the Cable Management Bar(s) into the
Extender Brackets.
Note: There will typically be one cable management bar used for a 1RU panel and two cable
management bars used for a 2RU panel.
49006-AMB Angled Rear Cable Management Bar
using Extender Brackets shown
1RU Flat Panel Recessed using Extender Brackets
2RU Angled Panel using Extender Brackets
2RU Flat Panel Recessed using Extender Brackets
Potential Solutions With Use of Extender Brackets:
Use of the Extender Brackets to Recess-Mount
a Flat Patch Panel
Solution: Extender Brackets provide desired
setback of the patch panel.
Solution: Extender Brackets avoid interfering
rail profile and provide desired setback of the
patch panel.
Note: 2-post racks, which have these flange-type vertical rails, may also exist.
1. Place cage nuts in the square holes on the Extender Brackets.
Notes:
• If using the 2RU size Extender Brackets, cage nuts are only needed in the
top and bottom holes of each bracket for this application.
• These cage nuts are user-supplied and should match job site hardware in
size (12-24, 10-32, M5, or M6 hardware are all commonly used).
2. Mount patch panel to cabinet or rack vertical rails using the long rack-mount screws.
Note: These screws are user-supplied and should match job site hardware size (12-24, 10-32,
M5, or M6 hardware are all commonly used).
1. Place cage nuts into all the square holes on the Extender Brackets.
Notes:
• Cage nuts are also user-supplied and should match job site installation
hardware size.
• If 49258-TWB Cable Management is being installed, only one cage nut will
be required on each Extender Bracket for a 1RU installation, or two cage
nuts per bracket for a 2RU installation.
Installation
Potential Solutions with Use of Extender Brackets:
Use of the Extender Brackets with Other
Rear Cable Managers
Installation
49006-AMB Angled Rear Cable
Management Bar
49258-TWB Tie Wrap Bar49005-DMB High-density Cable
Management Bar
Note: 2-post racks, which have these flange-type vertical rails, may also exist.
Note: Both 1RU and 2RU Flat or angled patch panels are supported in this application.
Installation of Rear Cable Managers in cabinets or 4-post racks may be aided by use of the
Extender Brackets:
Solution: Extender Brackets avoid interfering
rail profile and provide proper setback for
cable manager.
Solution:
Extender Brackets provide proper
setback for rear cable manager.
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com
LIMITED 1 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by
Leviton is free of defects in materials and workmanship under normal and proper use for one year from the purchase date. Leviton’s
only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-
3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation.This warranty is void
if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner,
or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by
the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose,
is limited to one year. Leviton is not liable for incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty
obligation.The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.