Lightcloud XDIM User manual

1(844) LIGHTCLOUD
1(844) 544-4825
WE’RE HERE TO HELP:
Welcome
Lightcloud
XDIM/LCB
Phase Dimmer

Hello
The Lightcloud Blue Phase Dimmer can be used to
control the wired standard lighting or wirelessly control
the Lightcloud Blue-enabled lighting, no Gateway or
Hub required. Easily use the up/down paddle to adjust
the dim level or turn lights on/off. Indicator lights
illuminate to reflect current brightness levels and online
status.
Product Features & Specifications
• Voltage: 120V
• Color: Matte White
• Dimming Protocol: Phase-cut
• Max Load (Dimming Capacity):
LED/CFL: 300W
INC/HAL/ELV: 500W
MLV: 400VA
• Warranty:
3-year, limited warranty
• Compatible with a broad
range of high-efficiency loads
• Power monitoring
(neutral wire is required)
• Neutral optional for
retrofit applications
• High/Low end adjustment

Safety Information
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
1 (844) 544-4825
• To avoid risk of fire and electrical shock, products shall be installed
in accordance with electrical code and regulations.
• Cut off the power at the circuit breaker or fuse before installation.
• If you’re not clear about any content of the instructions, please
consult a licensed electrician.
• To avoid the risk of overheating and possible damage to the
equipment, do not use the product to control a receptacle,
motor-operated appliance or a transformer-supplied appliance.
• This product applies to compatible, dimmable incandescent,
magnetic low-voltage halogen, electronic low-voltage halogen,
CFL and LED products.
• When connecting multiple products with a single dimmer, do not
mix product types. All products shall be either dimmable LED, CFL
or incandescent products. Using the same type of products will
enhance dimmer performance.
• Switch to the leading edge control mode when an inductive load
(i.e., incandescent or magnetic low-voltage halogen) is used.
Switch to trailing edge control mode when a capacitive load
(i.e., electronic low-voltage halogen, CFL or LEDis used.

Parts Included and Tools Needed
1
Parts Included
Jumper Wire
(1 pcs)
Mounting
Screws (2 pcs)
Base Plate
(1 pcs)
5PIN Wiring
Terminal (2 pcs)
2PIN Wiring
Terminal (3 pcs) Connection Wire (5pcs)
Face Plate
(1 pcs)
Dimmer (1 pcs)
Tools Needed to Install the Dimmer
2
• 5mm Philips Screwdriver
• Electrical Tape
• Electrician Knife
• Test Pencil
• Pliers
• Ruler

Basic Operation
1
Replaceable Control Component
• Control Component can detach from
Power/Communication Component.
Power/Communication Component
Control Component

• White indicator light will remain on for 3 seconds. The timeout
and brightness of the indicator lights can be adjusted in the
Lightcloud Blue app.
Basic Operation
(cont’d)
Functional Parts
Power Indicator
Power
Indicator
Power Cut
Off Switch
Brightness
Indicator
Off/Down
Paddle
On/Up Paddle
Switch
Reset
Switch
Status
Indicator
• Short Press: Within 0.5 seconds
• Long Press: Over 0.5 seconds
• Double Press: Within 1 second
2
2a

• Turn light off: When the light is on, short press the
Off/Down Paddle once
• Quickly adjust to the lowest dim level: When the light is on
or off, press the Off/Down Paddle 2 times
• Gradually decrease brightness: When the light is on, press
and hold the Off/Down Paddle, the brightness gradually
decreases, until you release it until the brightness reaches
0% or until you release it to stop the brightness change
• Turn light on: When the light is off, short press the On/Up
Paddle once
• Continuously increase brightness: When the light is on,
short press the On/Up Paddle, the brightness increases
until the brightness reaches 100%
• Gradually increase brightness: When the light is on, press
and hold the On/Up Paddle, the brightness will gradually
increase until the brightness reaches the minimum level or
until the On/Up is released
• Quickly adjust brightness: When the light is on or off, press
the On/Up Paddle for 2 consecutive times
Basic Operation
(cont’d)
On/Up Paddle
Off/Down Paddle
2c
2b
• F: Forward Phase Control (leading edge control mode)
• A: Auto detect control mode
• R: Reverse Phase Control (training edge control mode)
Switch
2d
Note: after dip switch, please power off and then power on again.

Basic Operation
(cont’d)
Basic Operation
(cont’d)
Brightness Indicator
2h
LED 11
LED 10
LED 9
LED 8
LED 7
LED 6
LED 5
LED 4
LED 3
LED 2
LED 1
Power
Indicator
Brightness
Indicator
• Flash red (1s on/ 1s off): Device is not provisioned
• Steady green: Device is provisioned
2e
Status Indicator Light
2f
• Push in to connect to line voltage
• Pull out to disconnect light voltage
Power Cut Off Switch
2g
• Restoring factory settings: Press and hold the reset switch
until the status indicator light blinks red. The dimmer is now
reset and ready to be paired. (The dimmer is waiting to be
added to the Lightcloud Blue network)
Reset Switch
Note: When pairing to the Lightcloud Blue APP, Bluetooth must
be enabled on the mobile device.

Basic Operation
(cont’d)
Multi-Gang Installation Derating
5
Single-Gang
Rating
500W ELV
400VA MLV
400W ELV
300VA MLV
300W ELV
200VA MLV
300 W CFL/LED/
Electronic
self-ballasted
300 W CFL/LED/
Electronic
self-ballasted
300 W CFL/LED/
Electronic
self-ballasted
120 Vac,
60 Hz,
500 W Tungsten
Double-Gang
Rating
Triple-Gang
Rating
120 Vac,
60 Hz,
400 W Tungsten
120 Vac,
60 Hz,
300 W Tungsten
Note: Brightness Indicator lights will stay illuminated while circuit it powered on.
No.
1
2
3
4
Brightness Level
Brightness Level 1
Brightness Level 2
Brightness Level 3
Brightness Level 4
5
Brightness Level 56
7
8
9
10
Brightness Indicator
LED 2
LED 2~LED 3
Brightness Level 9 LED 2~LED 10
LED 2~LED 4
Brightness Level 8 LED 2~LED 9
LED 2~LED 5
LED 2~LED 6
Brightness Level 6 LED 2~LED 7
Brightness Level 10 LED 2~LED 11
Brightness Level 7 LED 2~LED 8

Installing your Lightcloud Blue Device
1Turn off Power
OFF
OFF
WARNING
• Place the wall switch in the off position
If the XDIM dimmer is currently installed, it can be converted
to a XDIM/LCB dimmer, no rewiring required.
2Remove Existing Switch
Remove Existing Switch
Replacing the XDIM dimmer Control
Component
• Remove existing wall panel and switch mounting screws.
• Carefully pull switch from wall box, identify and remove
the wires attached to the switch, then remove the switch.
• Do not remove the wires from the wall at this time.
(for new installations where an existing switch does not
exist, skip this step.)
• Turn off the main power at the breaker
panel or remove the fuse from the fuse box
2a
2b
• Remove the face plate to access the Power Cut Off Switch.
• Pull the Power Cut Off Switch out and remove the XDIM
Control Component.
• Replace it with the Operation Paddle Assembly for the
XDIM/LCB.
• Push in the Power Cut Off Switch.
• Skip to Controlling your Lightcloud Blue Device to continue.

Installing your Lightcloud Blue Device
Find a Suitable Location
• Lightcloud Blue devices should be positioned within
60 ft. of each other
• Building materials such as brick, concrete and steel
construction may require additional Lightcloud Blue
devices to extend around an obstruction
3
Identify the Type of Circuit
4
(cont’d)
Note If the wiring layout in the wall box does not resemble any of
these configurations, consult an electrician.
IMPORTANT NOTE:
For a Single-Pole application, note that one of the screw
terminals from the old switch being removed usually is a
different color (Black) or labeled Common. Tag the wire with
electrician tape and identify as the Common (hot wire or load)
in both the dimmer wall box and Single-Pole wall box.
Add an additional
Lightcloud Blue Device
to extend network range
around corners
BRICK, CONCRETE,
OR METAL WALL
<=60 ft.
<=60 ft.
Lightcloud
Blue APP
DRYWALL
OR SIMILAR
recommend <50ft.
depend on phone’s
BLE capability

Installing your Lightcloud Blue Device
(cont’d)
Single-Pole
Hot
Neutral
Ground
Load
Hot or Load
Neutral
Ground
Traveler 1
Traveler 2
3-Way

Installing your Lightcloud Blue Device
5
Typical Wiring
Single-Pole
(cont’d)
5a
Wiring Scheme 1 (neutral and hot wire)
N
P LD
L
Dimmer
Hot
Neutral
Ground
Load
screw
screw
Copper
Silver screw Black screw
Brass screw
Green
Tagged wire
Location 1
Dimmer
To breaker
or load
(Light(s))
To breaker
or load
(Light(s))
Copper
screw Brass
screw
Black
screw
Green
screw
Silver
screw
Ground
(Green or Bare Copper)
N
P
L
White
LD

Installing your Lightcloud Blue Device
(cont’d)
Wiring Scheme 2 (hot wire only)
N
P LD
L
Dimmer
Hot
Neutral
Ground
Load
screw
screw
Copper
Silver screw Black screw
Brass screw
Green
Tagged wire
Location 1
Dimmer
To breaker
or load
(Light(s))
To breaker
or load
(Light(s))
Copper
screw Brass
screw
Black
screw
Green
screw
Silver
screw
Ground
(Green or Bare Copper)
N
P
L
LD
Note: if you want to wiring XDIM/LCB without netural wire, you can consult with RAB.

Installing your Lightcloud Blue Device
(cont’d)
To breaker
or load
(Light(s))
Copper
screw Brass
screw
Black
screw
Tagged wire
Green
screw
Ground Jumper Wire
Common
terminal
Screw 2Screw 1
To breaker
or load
(Light(s))
Traveler 2
Traveler 1
Green
screw
Silver
screw
Ground
(Green or Bare Copper) (Green or Bare Copper)
N
P
L
LD
White
Wiring Scheme 4 (dimmer load side)
Hot
Neutral
Load
Ground
Jumper
Green 3-Way
Switch
Common
terminal Dimmer
Copper screw
Silver screw Black screw
Brass screw
N
P
L
LD
screw
Green
Location 1 Location 2
3-Way Switch
Dimmer
3-Way (3-way switch for retrofit installation, neutral and hot wire)
5b
Wiring Scheme 3 (dimmer line side)
N
P
L
LD
Common
terminal
GreenDimmer 3-Way
Switch
Hot
Neutral
Ground
Ground
Load
Jumper
Silver
screw Black screw
Brass screw
screw
Copper
screw
Green

Note: if you want to wiring XDIM/LCB without
netural wire, you can consult with RAB.
Installing your Lightcloud Blue Device
(cont’d)
To breaker
or load
(Light(s))
Copper
screw Brass
screw
Black
screw
Tagged wire
Green
screw
Ground Jumper Wire
Common
terminal
Screw 2Screw 1
To breaker
or load
(Light(s))
Traveler 2
Traveler 1
Green
screw
Silver
screw
Ground
(Green or Bare Copper) (Green or Bare Copper)
N
P
L
LD
Wiring Scheme 6 (dimmer load side)
Hot
Neutral
Load
Ground
Jumper
Green 3-Way
Switch
Common
terminal Dimmer
Copper screw
Silver screw Black screw
Brass screw
N
P
L
LD
screw
Green
Location 1 Location 2
3-Way Switch
Dimmer
3-Way (3-way switch for retrofit installation, hot wire only)
5c
Wiring Scheme 5 (dimmer line side)
N
P
L
LD
Common
terminal
GreenDimmer 3-Way
Switch
Hot
Neutral
Ground
Ground
Load
Jumper
Silver
screw Black screw
Brass screw
screw
Copper
screw
Green

Installing your Lightcloud Blue Device
(cont’d)
Wiring Scheme 7 (dimmer line side) Wiring Scheme 8 (dimmer load side)
N
P
L
Hot
Neutral
Ground
Ground
Load
Jumper
Dimmer Green Toggle
screw
Silver Black screw
Brass screw
LD
Copper
Switch
Hot
Neutral
Load
Ground
Jumper
Green Toggle
Switch
Common
terminal
Dimmer
Silver Black screw
Brass screw
Green
N
P
L
Copper screw
LD
3-Way (toggle switch for new construction installation, neutral and hot wire)
5d
screw screw
screw
Green
screw
Screw 1
Screw 2
Toggle Switch
Copper
screw Brass
screw
Black
screw
Green
screw
Silver
screw
N
P
L
LD
White
To breaker
or load
(Light(s))
Tagged wire
Green
screw
Ground Jumper wire
To breaker
or load
(Light(s))
Traveler 2
Traveler 1
Ground
(Green or Bare Copper) (Green or Bare Copper)
Location 1 Location 2
Dimmer

Note: if you want to wiring XDIM/LCB without
netural wire, you can consult with RAB.
Installing your Lightcloud Blue Device
(cont’d)
Wiring Scheme 9 (dimmer line side) Wiring Scheme 10 (dimmer load side)
N
P
L
Hot
Neutral
Ground
Ground
Load
Jumper
Dimmer Green Toggle
screw
Silver Black screw
Brass screw
LD
Copper
Switch
Hot
Neutral
Load
Ground
Jumper
Green Toggle
Switch
Common
terminal
Dimmer
Silver Black screw
Brass screw
Green
N
P
L
Copper screw
LD
3-Way (toggle switch for new construction installation, hot wire only)
5e
screw screw
screw
Green
screw
Screw 1
Screw 2
Toggle Switch
Copper
screw Brass
screw
Black
screw
Green
screw
Silver
screw
N
P
L
LD
To breaker
or load
(Light(s))
Tagged wire
Green
screw
Ground Jumper wire
To breaker
or load
(Light(s))
Traveler 2
Traveler 1
Ground
(Green or Bare Copper) (Green or Bare Copper)
Location 1 Location 2
Dimmer

Installing your Lightcloud Blue Device
(cont’d)
6
Install and Fix the Dimmer
• Carefully position all wires inside the wall box, leaving
enough room to insert the dimmer housing. Secure the
dimmer with the mounting screws provided.
Mounting screws
Wall Box
Dimmer
• Place the base plate
over the installed
dimmer and secure
it using provided
screws.
7
Install the Wall Plate
Separate Plate
7a
Screws
Base Plate
Dimmer

• Connect the face plate to the installed base plate and
gently push it until it clicks into place.
Installing your Lightcloud Blue Device
(cont’d)
Face Plate
Base Plate
This manual suits for next models
1
Table of contents