FEATURES AND SPECIFICATIONS
LEDS: 12 10 Watt LEDs (RGBW 4 in 1)
Beam angle: 25 º
Control system: DMX-512
DMX channels: 8
DMX connectors: 3 pin XLR
Voltage: 100 - 250 VAC / 50/60Hz
Max power consumption: 150 Watts
Size: 11 5/8"D x 11 5/8"W x 11 1/4"H
Body material: Cast Aluminum
Body color: black
Weight: 11 lbs
DESCRIPTION
The FXLD1012C4I is a PAR style RGBW LED
lighting fixture. It is suitable for stage, disco, night
club, and other artistic applications. It has several
stand alone control modes and can operate via a DMX-
512 external signal. A double yoke enables it to be
operated in several positions.
INSTALLATION
LOCATION
The FXLD1012C4I is rated IP20 and is intended for
INDOOR USE ONLY.
Locate the unit in a well ventilated area away from
moisture and heat. Holes are provided on the yoke to
install a lighting bar pipe clamp. A safety cable should
also be used.
POWER CONNECTIONS
The FXLD1012C4I has a line cord for connection to a
120 VAC, 15 Amp, 60Hz, grounded service.
The safety ground pin on the power cord must be used.
DMX CONNECTIONS
A system using DMX control should be connected as a
chain of devices. In other words the control signal
cable should proceed from the controller to the first
receiving device and then to others in a continuous
"daisy chain" fashion.
The fixture has a DMX IN and a DMX OUT connector
to be used to connect the chain. The control cable
should NOT be split into a multiple run star
arrangement with a cable running from the controller
directly to each receiving device pack.
DMX CONNECTOR PIN ASSIGNMENTS
There are two different connectors which can be used
for DMX control. They are both XLR type connectors.
Some units use 3 pin connectors. Others use 5 pin
connectors. The FXLD1012C4I receives a DMX signal
on the 3 pin MALE connector on the back of the unit.
The 3 pin FEMALE connector is used to connect the
next DMX device on the control chain. If your console
uses a 5 pin connector you can make up an adapter
cable to accommodate this. The table below shows the
pin assignments for BOTH the 3 pin and 5 pin
connectors.
DMX TERMINATION
A DMX chain should be terminated at the last
receiving device on the chain. This is done by
PIN # SIGNAL NAME
1 DMX COMMON
2 DMX DATA -
3 DMX DATA +
4 NOT USED
5 NOT USED
CAUTION
RISK OF ELECTRIC SHOCK

Page 2 of 4
FXLD1012C4I LED FIXTURE
Version0.1 OWNERSMANUAL 02/15/2012
www.lightronic.com
Lightronics Inc. 509 Central Drive Virginia Beach, Va 234354 757 486 3588
installing a commonly available 1/4 Watt, 120 Ohm
resistor across the DATA - and DATA + wires at the
last device. If you have only a few fixtures very close
together and a very short run to the controller then you
may be able to operate without the terminator.
OPERATION
Operating options are set using the LCD display and 4
buttons
(MENU, UP, DOWN, ENTER)
on the rear of
the fixture.
Push
MENU
to access the operating options. Then use
UP
and
DOWN
to scroll through the available choices.
When you reach the option you want to set or change -
push
ENTER
.Now you can view the current setting
for the option and/or change it. Push
ENTER
to save
your changes. See the "MENU NAVIGATION"
diagram for additional details.
There are 7 main operation modes: DMX, Color Fade,
Color Change, Color, Master Auto, and Master Sound,
and Master/Slave Operation
DMX OPERATION
Use the DMX512 menu to set the starting address of
the unit. You can set the starting address of the unit
with the UP and DOWN buttons.
The fixture uses eight channels assigned as follows:
CHANNEL 1: Master for the RGBW channels.
CHANNEL 2: Strobe rate for the RGBW channels.
CHANNEL 3: Red level (255 = maximum).
CHANNEL 4: Green level (255 = maximum).
CHANNEL 5: Blue level (255 = maximum).
CHANNEL 6: White level (255 = maximum).
CHANNEL 7: RGBW Color selection for 25 colors
and effects.
CHANNEL 8: Mixing speed for channel 7 functions.
DISPLAY ON/OFF
You can set the display so that it will turn off after a
short delay by using the
Display _OFF
menu. Push
MENU to turn it back on.
COLOR FADE
The Color Fade mode cycles smoothly through a
sequence of colors. Use the
COLOR FADE
menu to
set the speed and activate the option. The range is
from 00 to 255. 255 is fastest.
COLOR CHANGE
The Color Change mode switches through a sequence
of seven colors. Use the
Color Change
menu to set
the sequence speed and activate the option. The range
is from 00 to 255. 255 is fastest.
COLOR
The Color menu enables you to set the unit to one of
15 colors or OFF. Use the
Color
menu to select a
color. 00 is OFF.
MASTER AUTO
The Master Auto mode causes the unit to cycle through
both the Color Change and Color Fade sequences.
There is no selection or speed setting. The effect
begins when you enter the
Master Auto
menu.
MASTER SOUND
The Master Sound mode causes the unit to cycle
through the Color Change sequence in sync with music
bass notes. There is no selection or speed setting. The
effect begins when you enter the
Master Sound
menu.
FXLD1012C4I REAR PANEL VIEW
MENU UP DOWN ENTER
FUSE
DMX IN DMX OUT
SELECT MENU < >
DMX512 ADDRESS 001
POWER

Page 3 of 4
FXLD1012C4I LED FIXTURE
Version0.1
OWNERSMANUAL
02/15/2012
www.lightronic.com
Lightronics Inc. 509 Central Drive Virginia Beach, Va 234354 757 486 3588
MASTER /SLAVE OPERATION
The FXLD1012C4I can operate in a Master/Slave
mode where one of the units can synchronize up to 4
other units.
Connect the units together using the DMX IN and
DMX OUT connectors. Set the unit to be the Master
in one of the modes above. Use the Slave menu to set
the others to consecutive numbers 1 thru 4 as needed.
MAINTENANCE AND REPAIR
TROUBLESHOOTING
Check that you have power applied to the unit.
Check the fuse.
Check the DMX control cable.
Check the address settings of the unit and the
controller.
REPAIR
The only FXLD1012C4I user serviceable part is a
externally accessible fuse.
DISCONNECT THE UNIT FROM POWER BEFORE
CHECKING OR REPLACING THE FUSE.
Replace the fuse ONLY with a 5mm x 20mm 2.0
Amp, 250VAC, fast blow fuse.
Internal service on the unit by other than Lightronics
authorized agents will void the warranty. If service is
required, contact the dealer from whom you purchased
the item, or contact the Lightronics, Service
Department, 509 Central Drive, Virginia Beach, VA
23454. Tel: 757 486 3588.
PHOTOMETRIC CHARACTERISTICS
Distance Illuminance Beam Diam.
(ft) (Lux) (ft)
10 917 6
20 230 12
30 112 17
CAUTION DO NOT OPEN UNIT
RISK OF ELECTRIC SHOCK
RISK OF FIRE

This product is warranted for a period of TWO YEARS from the date of purchase against defects in
materials and workmanship.
This warranty is subject to the following restrictions and conditions:
A) If service is required, you may be asked to provide proof of purchase from an authorized
Lightronics dealer.
B) This warranty is valid only for the original purchaser of the unit.
C) This warranty does not apply to damage resulting from abuse, misuse, accidents, shipping,
and repairs or modifications by anyone other than an authorized Lightronics service
representative.
D) This warranty is void if the serial number is removed, altered or defaced.
E) This warranty does not cover loss or damage, direct or indirect arising from the use or
inability to use this product.
F) Lightronics reserves the right to make any changes, modifications, or updates as deemed
appropriate by Lightronics to products returned for service. Such changes may be made
without prior notification to the user and without incurring any responsibility or liability for
modifications or changes to equipment previously supplied. Lightronics is not responsible
for supplying new equipment in accordance with any earlier specifications.
G)This warranty is the only warranty either expressed, implied, or statutory, upon which the
equipment is purchased. No representatives, dealers or any of their agents are authorized
to make any warranties, guarantees, or representations other than expressly stated herein.
H) This warranty does not cover the cost of shipping products to or from Lightronics for
service.
I) Lightronics Inc. reserves the right to make changes as deemed necessary to this warranty
without prior notification.
WARRANT
Y
Lightronics Inc. 509 Central Drive Virginia Beach, VA 23454 20100211
Other Lightronics Floodlight manuals