1. Feature
ZL-6XXA-R is an electronic thermostat with RS 485, dedicated to control the cold storage,
seafood machine, water heaters, etc.
Front panel water-proof level is IP65. The small case size is same as those on the market.
2. Main Function
● Temperature measurement
● Temperature display
● Temperature calibration
● Compressor delay protection
● Buzzer alarm output
● Defrost control (Based on both timer and temperatures)
● Fan control
● Max high-temperature or min low-temperature exceed warning.
● Sensor failure warning
● External warning input
● RS 485
3. Model List
Model
ZL-610A-R
ZL-620A-R
ZL-630A-R
Cool+External Alarm Input+High Efficient Intelligent Defrost+RS 485
Cool+External Alarm Input+High Efficient Intelligent Defrost +Fan Control+RS 485
Function
Cool+External Alarm Input+Periodic Defrost+RS 485
4. Size Specification
1. Front panel dimension: 78* 34.5mm
2. Drilling template: 71* 29mm
3. Whole machines dimension: 78* 34.5* 71mm
4. Length of sensor(s): 3m (including the sensor probe)
5. Technical Specification
● Temperature Sensor: NTC
● Setting Range: -40~120℃
● Display Range: -50~130℃

● Working Temperature: -10~45℃
● Storage Temperature: -30~70℃
● Humidity: 5~85%RH (without dewing)
● Power Supply: AC185 ~ 245V 50HZ
● Terminal Wire: <= 2 * 1.5mm2 or 1 * 2.5mm2
● Load Current: 10A 250Vac(Resistive load)
● Case: PC + ABS Fire Proof
● Protection Degree: IP65 (front panel)
6. Operation Instruction
6.1 Display Indication
Display Sign Description
Icon Function On Off Blinking
Compressor On Off Compressor will be on after
protection delay
Defrost Defrosting ---- Water dripping during defrosting
Temperature Setting
Setting temperature
---- ----
Repairing Faulty No fault ----
Warning Warning No warning
----
Panel Digit Indication
Four red digits display the measured temperature and warning code.
No. Display Code Warning Information
1 E01 Room temperature sensor fault
( short circuit or open circuit )
2 E02 Defrosting temperature sensor fault
( short circuit or open circuit )
3 Hi Temperature exceeds the MAX value
4 Lo Temperature exceeds the MIN value
5 EE Data access error
6 Err Password error
7 iA External warning
8 dEF Defrosting operation
9 UnL Restore the default password ”1111”
6.2 Keypad Operation
6.2.1 Set refrigeration temperature

Keeping 【S】 pressed for 3 seconds to enter temperature setting mode. The indicator
is on, and the digital shows the set temperature. Press key 【▲】 or 【▼】 to change
the set temperature ( Keeping 【▲】 or 【▼】 pressed, it will be adjusted quickly.). Press
【S】, the set temperature will be saved and leave the setting mode. Or do not press any key
for 30 seconds; the device will leave the set mode without saving the set data.
6.2.2 Set system parameters
Enter Into System Parameter Setting Mode
Use the password to enter into the parameter setting mode, the factory password is “1111”.
Keep 【P】 pressed for 3 seconds to enter the mode. The digital displays 『---0』, then press
【▼】 to the digit of the password, press 【▲】 to the value of the digit, press 【S】 to
confirm. If the password is wrong, it will shows 『Err』, and returns to the measuring
temperature states after the buzzer beeping 3 times. If the password is right, the buzzer beeps
once and enters into the mode. Digital will display a parameter code『U10』. Press 【▲】
or 【▼】 to select the parameter code. Press 【S】 to show its value. Press 【▲】 or 【▼】
to set the value. Press【S】 to return parameter code display status.
Exit the Mode
Keep depressing 【P】 for 3 seconds, the set parameters will be saved, the mode exits.
If do not press any key for 30 seconds, the mode will exit without saving all the set data.
6.3 Parameter Code and Description Table:
ZL-610A-R:
No
Parameter
code Function Range Note Factory
setting
1 U10 Compressor power on delay time 1~100min 3
2 U11 Compressor MIN continuous work
time 0~100min 3
3 U12 Compressor run frequency 0~8 0: Disable 5
4 U20 Room temperature sensor calibration
-9.9~+9.9 0
5 U22 Temperature difference 0.1~+10.0℃ The hysteresis
of control 1.0
6 U30 Defrosting cycle 0~180 hour 0: Not defrost 12
7 U31 Defrosting﹙end﹚time 1~180min 30
8 U33 Dripping water time 0~180min 5
9 U34 Over temperature warning delay
time after defrost ends 0~180 hour 0: Disable 2
10
U35 Defrost when the device starts 0~1 0: Disable
1:Enable 0
11
U36 Defrost delay time when the device
start 0~180min 0: Disable 0
12
U50 High-temperature warning deviation
value to Max Temp 0~60℃ 0: Disable 0

13
U51 Low-temperature warning deviation
value to Min Temp 0~60℃ 0: Disable 0
14
U52 Over-temperature warning delay
time 1~180min 30
15
U53 First over-temperature warning
delay time after power supply 0~180 hour 0: Disable 2
16
U60 External input warning mode 0~4
0:Warning off
1:On, Lock
2:On, Unlock
3:Off, Lock
4:Off, Unlock
0
17
U61 External warning input delay 0~120min 0
18
U62 Buzzer warning 0~1 0:Warning off
1:Warning on
19
U97 Baud rate setting 0 ~ 3
0: 2400bps
1: 4800bps
2: 9600bps
3: 19200bps
3
20
U98 Device address 1 ~ 99 ---- 1
21
U99 Password 0000~9999 1111
22
End Finished setting
ZL-620A-R:
No
Parameter
code Function Range Note Factory
setting
1 U10 Compressor power on delay time 1~100min 3
2 U11 Compressor MIN continuous work
time 0~100min 3
3 U12 Compressor run frequency 0~8 0: Disable 5
4 U20 Room temperature sensor
calibration -9.9~+9.9 0
5 U21 Defrosting sensor calibration -9.9~+9.9 0
6 U22 Temperature difference 0.1~+10.0℃ The hysteresis
of control 1.0
7 U30 Defrosting cycle 0~180 hour 0: Not defrost
12
8 U31 Defrosting﹙end﹚time 1~180min 30
9 U32 Defrosting end temperature 0.5~50℃ 15
10
U33 Dripping water time 0~180min 5
11
U34 Over temperature warning delay
time after defrost ends 0~180 hour 0: Disable 2
12
U35 Defrost when the device starts 0~1 0: Disable 0

1:Enable
13
U36 Defrost delay time when the device
start 0~180min 0: Disable 0
14
U50 High-temperature warning deviation
value to Max Temp 0~60℃ 0: Disable 0
15
U51 Low-temperature warning deviation
value to Min Temp 0~60℃ 0: Disable 0
16
U52 Over-temperature warning delay
time 1~180min 30
17
U53 First over-temperature warning
delay time after power supply 0~180 hour 0: Disable 2
18 U60
External input warning mode 0~4
0:Warning off
1:On, Lock
2:On, Unlock
3:Off, Lock
4:Off, Unlock
0
19
U61 External warning input delay 0~120min 0
20
U62 Buzzer warning 0~1 0:Warning off
1:Warning on
21
U97 Baud rate setting 0 ~ 3
0: 2400bps
1: 4800bps
2: 9600bps
3: 19200bps
3
22
U98 Device address 1 ~ 99 ---- 1
23
U99 Password 0000~9999 1111
24
End Finished setting
ZL-630A-R:
No
Parameter
code Function Range Note Factory
setting
1 U10 Compressor power on delay time 1~100min 3
2 U11 Compressor MIN continuous work
time 0~100min 3
3 U12 Compressor run frequency 0~8 0: Disable 5
4 U20 Room temperature sensor calibration
-9.9~+9.9 0
5 U21 Defrosting sensor calibration -9.9~+9.9 0
6 U22 Temperature difference 0.1~+10.0℃ The hysteresis
of control 1.0
7 U30 Defrosting cycle 0~180 hour 0: Not defrost
12
8 U31 Defrosting﹙end﹚time 1~180min 30
9 U32 Defrosting end temperature 0.5~50℃ 15

10
U33 Dripping water time 0~180min 5
11
U34 Over temperature warning delay time
after defrost ends 0~180 hour 0: Disable 2
12
U35 Defrost when the device starts 0~1 0: Disable
1:Enable 0
13
U36 Defrost delay time when the device
start 0~180min 0: Disable 0
14
U40 Fan start temperature -45~+120℃ -10
15
U41 Fan start-up delay 0~600sec 60
16
U42 Fan stop delay 0~600sec 0
17
U43 Fan mode 0~1 0: Controlled
1: Free mode
0
18
U50 High-temperature warning deviation
value to Max Temp 0~60℃ 0: Disable 0
19
U51 Low-temperature warning deviation
value to Min Temp 0~60℃ 0: Disable 0
20
U52 Over-temperature warning delay time
1~180min 30
21
U53 First over-temperature warning delay
time after power supply 0~180 hour 0: Disable 2
22
U60 External input warning mode 0~4
0:Warning off
1:On, Lock
2:On, Unlock
3:Off, Lock
4:Off, Unlock
0
23
U61 External warning input delay 0~120min 0
24
U62 Buzzer warning 0~1 0:Warning off
1:Warning on
25
U97 Baud rate setting 0 ~ 3
0: 2400bps
1: 4800bps
2: 9600bps
3: 19200bps
3
26
U98 Device address 1 ~ 99 ---- 1
27
U99 Password 0000~9999 1111
28
End Finished setting
7. Control Function Description
7.1 Compressor Control
● When the temperature “Set temperature”+”U22”, and the compressor has stopped for ≧
“U10”, the compressor starts.
● When the temperature “Set temperature”≦-”U22”, and the compressor has run for “U11”,

the compressor stops.
For example:
If set temperature is 18℃,【U22】is 2 . When the temperature 20 , compressor starts. If ℃ ≧ ℃
the temperature 16≦ ℃,compressor stops. The room temperature will be between 18±2 .℃
● Compressor emergent on
Press and hold “▼” key for 5 seconds, the compressor will power on if the following meets:
◆ The compressor has stopped for "U10";
◆ The controller is not in defrosting or dripping water states;
◆ Room temperature is between "Set temperature"+”U22” and “Set
temperature”-”U22”.
After compressor emergent on, when room temperature goes down to “Set
temperature”-”U22”, it stops cooling.
7.2 Compressor Delay Protection
● After power supply, the compressor is able to start only after the time (U10) has passed.
● After the compressor stops, it is able to restart again only after the time (U10) has passed.
● After the compressor starts, it is able to stop only after the time (U11) has passed.
7.3 Fan Control (Only for ZL-630A-R)
7.3.1 Fan control mode: Controlled mode and free mode.
7.3.2 Controlled mode
● In the state of cooling, when the evaporator temperature is less than (U40), or the cooling
time is more than (U41), the fan will starts.
● If set 0 for (U41), the fan will start immediately when come into the cooling state.
● After cooling stops, the fan will stop after the time of (U41).
● If set 0 for (U41), the fan will stop immediately when cooling stops.
7.3.3 Free mode
The fan will be always running, except during defrosting. In this mode, (U40), (U41) and
(U42) parameters have no effect.
7.4 Protection Running Mode When Room Temperature Sensor Fails
When the room temperature sensor fails, the system will automatically run into the protected
running mode. In this mode, the compressor will run and stop with the period of 30 minutes.
Compressor works for U12* 3 minutes, stops for ﹛30 - (U12* 3) ﹜minutes.
For example: Set 【U12】 is 3,when the temperature sensor fails,compressor runs for 9
minutes and then stops 21 minutes, move in circles. If U12=0, system stops when sensor fails
7.5 Protection Running Mode When Defrost Temperature Sensor Fails
(for ZL-620A-R, ZL-630A-R)
● When the defrost sensor fails, the controller will periodically defrost according to (U30)
and (U31). The dripping water function will be cancelled.
● If the fan is in the "controlled mode", it will cancel the conditions of fan temperature
control; the fan will work according to (U41) and (U42) parameter. (For ZL-630A-R)
7.6 Defrosting Function
7.6.1 Automatic defrosting
● When the compressor continuously running time reaches the time of defrost cycle (U30),
the system starts to defrost.
● When one of the conditions (defrosting end time (U31) and defrosting end temperature

(U32)) meets, the defrosting stops.
● ZL-610A-R will periodically defrost according to (U30) and (U31) parameter.
7.6.2 Manual forced defrosting
● When in non-defrosting stage, keep 【▲】 pressed for 7 seconds, the system starts forced
defrosting.
● When in defrosting stage, keep 【▲】 pressed for 7 seconds, the defrosting stops.
7.6.3 Dripping water function
● After defrosting, system will drip water for the time (U33), then start cooling.
● This function will not work when:
After manual forced defrosting Defrosting temperature sensor fails◆ ◆
7.6.4 Check defrosting data
● Check defrosting sensor temperature:
When the digit shows the room temperature, depress 【▲】, the digits will show defrost
sensor’s temperature. Do not keep depressing for 7 seconds, to avoid the device stops forced
defrosting. (Suits for ZL-620A-R and ZL-630A-R)
● Check the left time of defrosting or dropping:
Depress 【▼】to show the left time of defrosting, or dripping. Do not keep depressed for 7
seconds.
7.7 Buzzer Function
Buzzer sounds shortly for every key press. When confirming the parameter setting, it sounds
longer. 3 short beeps means invalid. When the system comes wrong or external alarm input,
the buzzer alarm function will be off if U62=0, or the buzzer continuous alarming if U62=1.
After the system problem solved and disappears, press 【P】 key to stop warning.
7.8 High-temperature and Low-temperature Warning
● When the room temperature ≥ “set temperature”+ “U50”, and the time reaches to “U52 or
U53 or U34”, high temperature warning starts.
● When the test temperature ≦“set temperature”+ “U51”, and the time reaches to “U52 or
U53 or U34”, low temperature warning starts.
7.9 External Input Warning
There are following ways for the external warning input, when the condition meets, the
device will warn:
Normal On: If close, warning starts.
Normal Off: If open, warning starts.
Lock: when the external warning input signal disappears, system keeps warning, until
pressing the【P】key to stop the warning.
Unlock: when the external warning input signal disappears, warning stops.
7.10 Temperature Calibration Function
When there is tolerance between the measured temperature and real temperature, set
parameter U20 and U21 to calibrate. The calibration range is ±9.9℃. When setting the
parameter, the step is 0.1℃ for every key press. Keep the key pressed, the set data will
increase/decrease continuously and quickly.
7.11 Restore the Default Parameters and Password
Keep【P】and 【▲】keys pressed for 5 seconds, the device displays “UnL”, press 【▼】 twice,
buzzer sounds, system auto restores the default parameters and password“1111”.

8. Controller Installation
8.1 Warning
Avoid installing the device in the following environment:
● Relative humidity is greater than 90%, or possibly dewing.
● Strong vibration.
● Possibility be dropped, or within fog.
● Exposed to eroding and polluting gases (such as: air containing sulfur and ammonia, salty
fog, smoky mist) to prevent erosion and oxidation.
● Ambient containing explosive or inflammable materials/gases.
8.2 Installation Procedure
Insert the controller into hole (step one) Slide the bracket to fix the device (step two)
9. Electrical Connection
Warning
● Electrical wiring must be manipulated by certified electrician.
● Wrong power supply may damage the device and system seriously.
● Try with effort to layout the sensors and switches line apart from inductive load lines and
power supply lines. The sensors and switches lines are not allowed go with the power supply
lines and inductive load lines in a same pipeline, and are not allowed to pass near the
contactor, breaker and the similar.
● Reduce the length of sensors’ wiring as possible, avoid forming a spiral shape near the
power devices.
● Avoid direct contact with the internal electronic components.
● After finish and check the electrical wiring layout, before connect them to the device,
please follow this instruction: Pay attention the “electrical wiring diagram” below, wrong
connection possibly damages the device and the system, and may be dangerous to the user.
All security and protecting device for the equipments are necessary. They are very important
to protect the equipments, and the user’s safety.

Electrical wiring diagram
This manual suits for next models
3