Page 4 Form 402803
RETAIN THIS INFORMATION FOR FUTURE REFERENCE
When ordering replacement parts, list: Part Number, Description, Model Number and Series Letter.
LINCOLN provides a Distributor Network that stocks equipment and replacement parts.
VENT VALVE:
The 83948 Vent Valve is operated by compressed air from the same source
which operates the pump. When pump is in operation, air pressure keeps the
vent valve closed and lubricant is directed through the outlet and to the
injectors. When air to the pump is shut off, vent valve opens and supply line
pressure vents back into the reservoir.
SAFETYUNLOADER:
90942 Safety unloader is provided at the pump outlet to prevent the build-
up of dangerously high lubricant pressure in the system. It is factory set to
open at approximately 3,750 psi to 4,250 psi.
NOTE: Safety unloader requires no adjustment and should not be tampered
with.
WHAT TO DO IF:
Pump loses prime: Check lubricant supply.
10127 Vent Plug is provided at the pump outlet for expelling air which may
be pocketed in the lubricant. If pump operated continuously without
discharging lubricant, it is an indication that the pump has lost its prime.
Loosen the vent plug one turn until trapped air is pumped out. If pump
continues to operate without discharging lubricant, 10061 Pump Check and
66002 Steel Ball may be fouled. Remove and clean checks and check seats.
The 83948 VentValve may also be fouled. Foreign material may prevent
14722 Needle from seating proper]), or 14723 Valve Seat may be worn or
damaged. Clean or replace parts.
Failure of injectors to cycle can also be caused by a leak in the supply line.
Examine lines and connections.
Pump fails to operate: Check air supply.
TO PRIME SYSTEM
SUPPLYLINES:
After pump reservoir has been filled with recommended lubricant, loosen
all plugs in dead ends of injector manifolds and supply lines. Turn vent plug
in pump counter-clockwise one complete turn. Depress manual lube
pushbutton on door to start pump. Operate pump until lubricant bleeds
around vent plug to expel air pockets trapped between the pump and the
supply line connection. Tighten vent plug. continue operating pump unitl
lubricant flows around any plug. Tighten plug. Repeat this procedure until
all plug openings are tight and supply lines are primed. Turn off power to
reset controller.
IMPORTANT:
Refer to Owner/Operator Manual C8 259 to program controller on 85209.
FEEDERLINES:
Fill each feed line with lubricant before connecting lines to outlets of
injectors and bearings. This will prevent having to cycle each injector to
fill the feed line between injector and bearing.
INSTRUCTIONS FOR PUMP USING 85209 CONTROL PANEL
TO PRIME SYSTEM
SUPPLYLINES:
After pump reservoir has been filled with recommended lubricant, loosen
all plugs in dead ends of injectors manifolds and supply lines. Turn vent
plug in pump counter-clockwise one complete turn. Set the delay relay to
its maximum position (Refer to Service Manual Section C8, Page 133
Sefies). Depress push button on top of time control to start pump. Operate
pump until lubricant bleeds around vent plug to expel air pockets trapped
between the pump and the supply line connection. Tighten vent plug.
Continue operating pump until lubricant flows around any plug. Tighten
plug. Repeat this procedure until all plug openings are tight and supply
lines are primed. Open line switch to shut off pump.
IMPORTANT:
Reset the delay relay to desired interval (Refer to System Planning Manual).
FEEDERLINES:
Fill each line with lubricant before connecting lines to outlets of injectors and
bearings. This will prevent having to cycle each injector to fill the feed line
between injector and bearing.
INJECTORS:
Check injectors for proper operation by observing the movement of the
indicator stems.
INSTRUCTIONS FOR PUMP USING 83820 TIME CONTROL
INJECTORS:
Check the injectors for proper operation by observing the movement of the
indicator stems.
OPERATION:
When model 85530 times out it will initiate a lube cycle. The air solenoid
is energized to deliver air to the pump and air to the vent valve. Pump
begins dispensing lubricant through injectors to the bearings.
When all bearings have received lubricant, pressure rises in system to
actuate pressure switch. When pressure switch actuates, the control is reset
to de-energize solenoid valve cutting off air to pump and vent valve. Pump
stops, pressure vents and pressure switch de-actuates. Control begins
timing toward next lube event.
OPERATION
The timer (runs constantly when current is on), drives a cam which has lobes
set for the desired lubrication cycle frequency (Refer to Service Manual
Section C8, Page 133 Series). Lobes engage the micro-switch lever arm to
activate the switch, closing the circuit to open the 3-way solenoid air valve
permitting air to operate the pump. The pump discharges lubricant through
the supply line to the injectors. After the injectors operate (discharge lubricant
to the bearings), pump continues to build up lubricant pressure in the supply
line until sufficient to operate the pressure control which moves a switch
plate, breaking the circuit to the 3-way, solenoid air valve, shutting off the air
to the pump. Injectors automatically, re-charge with lubricant and system is
ready for the next lubrication cycle.
The pressure control is factory set for 2,500 psi, adequate for any normal
installation. If higher pressure is necessary (2,900 psi maximum), the pressure
control can be reset;
1) Loosen locknut.
2) Turn the housing clockwise into the pressure control body until proper
pressure is obtained.
3) Tighten locknut.
To lower pressure (1,500 psi minimum);
1) Loose locknut.
2) Turn the housing counter-clockwise into the pressure control
body until proper pressure is obtained.
3) Tighten locknut.