FlowMaster Rotary Driven Hydraulic Pump
Page Number - 6 7.5A-18100-D00 Form 402971
Disassembly Procedure (See illustration #6)
Tools Required:
- Hex Bit Socket Wrenches (3/8 square drive) with 3/8 hex,
5/32 hex, 1/4 hex.
- 3/8 O.D. Steel Rod
- 12 Crescent Wrench
- Spanner Wrench (for 3/8 diameter tube, 1/8 pin)
- 1/2 to 3/8 square drive adapter
- Torque wrench (1/2 square drive, 0 - 50 ft-lb capacity)
- Torque wrench (3/8 square drive, 0 - 120 in-lb capacity)
- 1/4 nut driver
- Screwdriver (flat blade, 1/8 blade width)
1. Remove the four Socket Head Screws (33) and separate
Manifold from the Hydraulic Motor (42).
2. Remove Pipe Plug (45) and drain the crankcase oil from
the Pump Housing (46).
3. Remove six self-threading Screws (29) and remove the
Housing Cover (30) and the Cover Gasket (31).
4. Remove Retaining Ring (57) and pull the Shovel Plug
(56) from the Housing Tube (55).
5. Remove two Socket Head Screws (44) and separate the
Hydraulic Motor (42) from the Pump Housing (46).
6. Remove two Outlet Pin Nuts (50) from the Pump Housing
(46).
7. Remove the Pump Subassembly (1 through 28) from
the Pump Housing (46). Pushing the subassembly up
with a wooden or plastic rod 3/4 O.D. against the Check
Seat Housing (28) is helpful.
8. Remove the Housing Tube (55) from the Pump Housing
(46) by inserting a 3/4 rod through the inlet holes at the
bottom of the Housing Tube (55) and unscrewing it.
9. Remove the Bronze Bearing (51), the O-Ring (52), and
the Backup Washer (53) from the Housing Tube (55).
10. Remove the Crankrod Assembly (1 through 8) from the
pump by unscrewing the Button Head Screws (12) and
then pulling out the Wrist Pin Bushings (13).
11. Remove the Check Seat Housing (28) from the
Reciprocating Tube (21). There is a 3/8 Allen Head
socket in the throat of the Check Seat Housing (28) to
facilitate removal.
12. Unscrew the Wrist Pin Anchor (14) from the
Reciprocating Tube (21) and pull the Plunger Assembly
(9 through 20) from the tube.
13. Using a 1/2 wooden or plastic rod, push the Cup Seal
(22) and the Pump Cylinder (24) from the Reciprocating
Tube (21).
14. Remove the Pump Plunger (20) from the Plunger Link
Rod (17). A spanner wrench, which uses the holes in
the Pump Plunger, is required.
15. Unscrew the Plunger Link Rod (17) from the Plunger
Tube (11) and slide off the Cup Seal (16), the Backup
Washer (15) and the Wrist Pin Anchor (14).
16. Unscrew the Plunger Tube (11) from the Outlet Pin (9).
17. To dismantle the Crankrod Assembly (1 through 8),
remove Flat Head Screws (1) and the Inner and Outer
Weights (2 & 3).
18. Remove the Retaining Rings (6) and press the Crank
Eccentric (7) out of the Ball Bearing (8). Be sure to
support the Ball Bearing (8) on the inner race.
Pump Assembly Procedure
1. When the pump is dissembled, it is recommended to
replace all seals and gaskets, which are included in the
270663 repair kit.
2. In the process of disassembly, examine the following
components and replace if excessive wear is indicated:
Ball Bearing (8), Crank Eccentric (7), Crankrod (5), Wrist
Pin Bushings (13), Plunger Tube (11), Pump Plunger and
Upper Check Parts (20, 19 and 18), Pump Cylinder (24),
Check Seat Housing and Lower Check Ball (28 and 26),
upper Bronze Bushing (51), Housing Tube (55), Shovel
Plug (56), and Reciprocating Tube (21).
3. Assembly Procedure is the reverse of the Disassembly
Procedure except for the following:
4. Install parts (22) through (28) into the Reciprocating Tube
(21) after the plunger assembly (9 through 20) is
installed.
5. Install the Pump Subassembly (1 through 28) into the
pump Housing (46) before tightening the Housing Tube
(55) to the Pump Housing (46). Be sure the
Reciprocating Tube (21) is inserted through both
bushings before tightening the Housing Tube (55).
6. Use loctite 242 (or similar product) medium strength
thread lock on all torqued threaded connections. Extreme
care must be exercised to prevent excess compound from
flowing into critical areas such as clearance fits and ball
check. Allow a minimum of 30 minutes cure time before
operating the pump.
7. Torque Specifications:
A. Plunger Tube (11) to Outlet Pin (9) - 100 to 110 In.-Lbs.
B. Button Head Screws (12) to Wrist Pin Anchor (14) 100
to 110 In.-Lbs.
C. Plunger Tube (11) to Plunger Link Rod (17) - 100 to 110
In.-Lbs.
D. Plunger Link Rod (17) to Pump Plunger (20) - 100 to
110 In.-Lbs.
E. Flat Head Screws (1) to Outer Weight (2) - 100 - 110
In.-Lbs.
F. Wrist Pin Anchor (14) to Reciprocating Tube (21) - 20 to
25 Ft.-Lbs.
G. Check Seat Housing (28) to Reciprocating Tube (21) -
20 to 25 Ft.-Lbs.
H. Outlet Pin Nut (50) to Pump Housing (47) - 30 to 35 Ft.-
Lbs.
I. Housing Tube (55) to Pump housing (47) - 20 to 25 Ft.-
Lbs.
8. Fill cranckcase with oil up to pipe plug (39) before
fastening housing cover (30) and housing gasket (31).
©
© indicates change