LINET OptiCare X Parts list manual

Instructions for Use and
Technical Description
OptiCare X
Integrated Mattress System for Multicare X
D9U003VSX-0101
Version: 00
Publication Date: 2021-10

D9U003VSX-0101_00
2
Manufacturer:
L I N E T spol. s r.o.
Želevčice 5
274 01 Slaný
Tel.: +420 312 576 111
Fax: +420 312 522 668
E-mail: [email protected]
http://www.linet.com
Service department: [email protected]
OptiCare X
Integrated mattress system for Multicare X
Author: LINET, s.r.o.
Related links: www.linet.com
D9U003VSX-0101
Version: 00
Publication Date: 2021-10
Copyright © L I N E T, s.r.o., 2021
Translation © L I N E T, s.r.o., 2021
All rights reserved.
All trademarks and brands are the property of the appropriate owners. The manufacturer reserves the right to changes in the
contents of the instructions for use that relate to the product´s technical regulations. It is for this reason that the contents of the in-
structions for use may indicate dierences from the current manufacture of the product. Reproduction, also excerpts, only with prior
permission of the publisher. Subject to changes due to technical developments. All technical data are rated data and are subject to
construction and manufacturing tolerances.

D9U003VSX-0101_00
3
1 Symbols and Denitions .............................................4
1.1 Warning Notices..........................................................4
1.1.1 Types of Warning Notices ........................................4
1.1.2 Structure of Warning Notices ...................................4
1.2 Instructions..................................................................4
1.3 Lists.............................................................................4
1.4 Symbols on the Package (OptiCare X) .......................5
1.5 Symbols and Labels on the Mattress (OptiCare X).....6
1.6 Serial Labels with UDI (OptiCare X) ...........................9
1.6.1 Serial Label for OptiCare X (SCU and mattress) .....9
1.6.2 Wash Label (mattress).............................................9
1.7 Acoustic signalisation (OptiCare X).............................10
1.8 Abbreviations ..............................................................11
1.9 Denitions ...................................................................11
2 Safety Instructions (only OptiCare X for Multicare X)
..........................................................................................12
3 Intended use (OptiCare X) ........................................... 15
3.1 User population...........................................................15
3.2 Contraindications ........................................................15
3.3 Operator......................................................................15
4 Product Description (OptiCare X)............................... 16
4.1 Mattress Structure.......................................................18
4.2 Cover ..........................................................................18
4.3 Bottom Deck ...............................................................18
4.4 Heel Section................................................................18
4.5 Safety Straps ..............................................................18
4.6 Transport Handles.......................................................19
4.7 SCU (System Control Unit) .........................................19
4.7.1 FIRMWARE.............................................................. 19
5 Technical Specication (OptiCare X) .........................20
5.1 Mechanical Specications...........................................20
5.2 Electrical Specications ..............................................20
5.3 Environment Conditions..............................................21
5.4 Electromagnetic Compatibility.....................................21
5.4.1 Manufacturer Instructions - Electromagnetic Emissions
..........................................................................................21
5.4.2 Manufacturer Instructions - Electromagnetic Susceptibility
..........................................................................................22
6 Use and Storage Conditions (OptiCare X) ................. 23
6.1 Storage .......................................................................23
7 Scope of Delivery and Product Variants (OptiCare X)
..........................................................................................23
7.1 Delivery .......................................................................23
7.2 Scope of Delivery........................................................23
8 Putting into Service (only OptiCare X for Multicare X)
..........................................................................................24
8.1 SCU (System Control Unit) .........................................26
8.2 Replacing the Mattress ...............................................26
9 Manipulation (OptiCare X for Multicare X) ................. 27
9.1 Manual CPR (during Transport or Power Loss) .......... 28
9.2 Automatic CPR (Multicare X with OptiCare X) ............29
9.3 Integrated Mattress Screen (Multicare X with OptiCare X)
..........................................................................................31
9.4 OptiCare X Mattress Controls (Multicare X with OptiCare X)
..........................................................................................32
9.4.1 MATTRESS DISCONNECTED................................32
9.4.2 MATTRESS IDENTIFICATION ................................33
9.4.3 MATTRESS INFLATION ..........................................33
9.4.4 OPTIMIZE MODE ...................................................34
9.4.5 MICROCLIMATE MANAGEMENT........................... 37
9.4.6 MOBILE MODE........................................................38
9.4.7 PRONE MODE ........................................................39
9.4.8 MAX MODE .............................................................41
9.4.9 CPR MODE (CPR ACTIVATED) ..............................42
9.4.10 PUMP DISCONNECTED.......................................43
9.4.11 AUTOMATIC PRESSURE ADJUSTMENT ERROR
..........................................................................................44
9.4.12 SCU LOG OUT ......................................................45
9.4.13 STATUSES (Multiboard X - LCD touchscreen)......46
9.5 Fault Codes (OptiCare X integrated mattress)............49
10 Equipment .................................................................. 50
10.1 X-ray Pocket .............................................................50
11 Cleaning/Disinfection (OptiCare X) ..........................51
11.1 Routine Cleaning and Disinfection ............................ 52
11.2 Full Cleaning and Disinfection...................................52
11.3 Removing the Mattress Cover...................................53
12 Troubleshooting (OptiCare X)...................................53
13 Maintenance (OptiCare X) .........................................57
13.1 Regular maintenance................................................57
13.2 Spare Parts ............................................................... 57
13.3 Safety Technical Checks...........................................57
14 Disposal (OptiCare X) ................................................58
14.1 Environment Protection.............................................58
14.2 Disposal ....................................................................58
14.2.1 Within Europe ........................................................58
14.2.2 Outside Europe ......................................................58
15 Warranty (OptiCare X)................................................59
16 Standards and Regulations (OptiCare X) ................59
Table of Contents

D9U003VSX-0101_00
4
1 Symbols and Denitions
1.1 Warning Notices
1.1.1 Types of Warning Notices
Warning notices are dierentiated by the type of danger using the following signal words:
► CAUTION warns about the risk of material damage.
► WARNING warns about the risk of physical injury.
► DANGER warns about the risk of fatal injury.
1.1.2 Structure of Warning Notices
SIGNAL WORDS!
Type and source of danger!
► Measures to avoid the danger.
1.2 Instructions
Structure of instructions:
► Perform this step.
Results, if necessary.
1.3 Lists
Structure of bulleted lists:
■ List level 1
□ List level 2
● List level 3

D9U003VSX-0101_00
5
1.4 Symbols on the Package (OptiCare X)
FRAGILE, HANDLE WITH CARE
THIS WAY UP
KEEP DRY (PROTECT FROM HUMIDITY)
PAPER RECYCLING SYMBOL
DO NOT STACK DURING STORAGE
DO NOT USE HAND TRUCK HERE
OVERSEAS PACKAGE: STACKING LIMIT BY NUMBER (3 PACKAGES FOR TRANS-
PORT)
OVERSEAS PACKAGE: STACKING LIMIT BY NUMBER (5 PACKAGES FOR STORAGE)
RECYCLING SYMBOL

D9U003VSX-0101_00
6
1.5 Symbols and Labels on the Mattress (OptiCare X)
DO NOT IRON!
DO NOT USE PHENOL!
DO NOT WRING!
REGULARLY INSPECT THE INSIDE OF THE COVER FOR CONTAMINATION
MACHINE WASH AT MAX. 71°C FOR 3 MINUTES
TUMBLE DRY ON LOW HEAT SETTING (MAX. 60°C)
HANDWASH WITH DETERGENT
(INITIAL TEMPERATURE OF HOT WATER SHOULD NOT EXCEED 50°C)
DISINFECT USING SOLUTION CONTAINING LESS THAN 1000 ppm OF CHLORINE
(REFER TO INSTRUCTIONS FOR USE)
WIPE WITH WATER
DRY

D9U003VSX-0101_00
7
DO NOT USE PHENOL!
HANDWASH WITH DETERGENT
(INITIAL TEMPERATURE OF HOT WATER SHOULD NOT EXCEED 50°C)
DISINFECT USING SOLUTION CONTAINING LESS THAN 10000 ppm OF CHLORINE
(REFER TO INSTRUCTIONS FOR USE)
DISINFECT USING SOLUTION CONTAINING LESS THAN 1000 ppm OF CHLORINE
(REFER TO INSTRUCTIONS FOR USE)
WIPE WITH WATER
COVER MATERIALS ARE FIRE RESISTANT TO BS7175, SOURCE 0, 1 AND 5
MATTRESS FOOT PART (OptiCare X)
WEEE SYMBOL (RECYCLE AS ELECTRONIC WASTE,
DO NOT PUT INTO THE HOUSEHOLD WASTE)
MEDICAL DEVICE (compatible with Medical Device Regulation)
MANUFACTURER
OptiCare X
0
5
25
75
95
100
OptiCare X
0
5
25
75
95
100
OptiCare X
0
5
25
75
95
100
OptiCare X
0
5
25
75
95
100
0
5
25
75
95
100

D9U003VSX-0101_00
8
MANUFACTURING DATE
REFERENCE NUMBER (PRODUCT TYPE DEPENDING ON CONFIGURATION)
SERIAL NUMBER
ONLY SUITABLE FOR INDOOR USE
APPLIED PARTS TYPE B
WARNING
READ INSTRUCTIONS FOR USE
T1AH ANTI-SURGE FUSE (SCU FUSE)
ALTERNATING CURRENT
THERMAL PROTECTION FOR TRANSFORMER

D9U003VSX-0101_00
9
SAFETY ISOLATING TRANSFORMER (GENERAL)
EARTH GROUND
CE MARK (EUROPEAN CONFORMITY)
1.6 Serial Labels with UDI (OptiCare X)
1.6.1 Serial Label for OptiCare X (SCU and mattress)
Serial label of the OptiCare X SCU is placed on the SCU under the foot board of the Multicare X bed. The serial label contains
information about Address of Manufacturer, Manufacturing Date (Year-Month-Day), Product Reference Number, Product Serial
Number, Global Trade Item Number (GTIN), Unique Device Identication (UDI), symbols and electrical specications. Serial label
of the OptiCare X mattress is placed at the mattress foot end. The serial label contains information about Address of Manufacturer,
Manufacturing Date (Year-Month-Day), Product Reference Number, Product Serial Number, Global Trade Item Number (GTIN),
Unique Device Identication (UDI) and symbols.
1.6.2 Wash Label (mattress)

D9U003VSX-0101_00
10
1.7 Acoustic signalisation (OptiCare X)
SOUND MEANING
REPEATED BEEP: 0,2s sound / 1s silence
(high priority)
Overpressure Fault (fault number 5)
Pressure Calibration Fault (fault number 94)
Solenoid Fail (fault number 98)
Deation Fault During CPR (fault number 105)
REPEATED BEEP: 0,2s sound / 5s silence
(medium priority)
Pressure Sensor Fault (fault number 4)
Air Hose Disconnected (fault number 101)
Inate Fault (fault number 102)
Kinked Air Hoses (fault number 107)
REPEATED BEEP: 0,2s sound / 10s silence
(low priority)
Major Inate Fault (fault number 2)
Deate Fault (fault number 3)
BOD Valve Fault (fault number 6)
Blower Fault (fault number 7)
Clogged Blower Filter (fault number 8)
Valve Short Circuit (fault number 14)
Not Supported Type of Mattress (fault number 106)
Optimization Failed (fault number 108)

D9U003VSX-0101_00
11
1.8 Abbreviations
AC ( ~ ) Alternating Current
CE European Conformity
CPR Cardiopulmonary Resuscitation
dB Sound Intensity Unit
DC ( ) Direct Current
CUC Conguration number
EMC Electromagnetic Compatibility
FET Field-eect transistor
HF High Frequency
HPL High Pressure Laminate
ICU Intensive Care Unit
INT. Duty Cycle
IP Ingress Protection
IV Intravenous
LED Light Emitting Diodes
ME Medical Electrical (Equipment)
ON Activation
OFF Deactivation
ppm parts per million, millionth (1000 ppm = 0,1%)
REF Reference Number (product type depending on conguration)
SCU System Control Unit (integrated mattress)
SN Serial Number
SW Software
SWL Safe Working Load
UDI Unique Device Identication (for medical devices)
USB Universal Serial Bus
WEEE Waste Electrical and Electronic Equipment
1.9 Denitions
Maximum Patient Weight The highest allowable load on the mattress.
Adult Patient having a physical size equal to or more than 146 cm, a mass equal to or more than
40 kg and a body mass index (BMI) equal to or more than 17 (according to IEC 60601-2-
52).

D9U003VSX-0101_00
12
OptiCare X for Multicare X
2 Safety Instructions (only OptiCare X for Multicare X)
WARNING!
Multicare X bed with OptiCare X integrated mattress system should be left in its lowest position when the pati-
ent is unattended in order to reduce risk of injury due to falls!
WARNING!
Siderails of the Multicare X bed should be located in the „up“ position to reduce the risk of the patient acci-
dentally slipping or rolling o the OptiCare X integrated mattress!
WARNING!
Inappropriate handling of the Multicare X power supply cord, e. g. by kinking, shearing or other mechanical
damages is hazardous!
WARNING!
When routing cables from OptiCare X integrated mattress system in the Multicare X bed avoid squeezing tho-
se cables between parts of the Multicare X bed!
WARNING!
The OptiCare X integrated mattress system with Multicare X bed are intended for adults.
► Follow the chapter Intended use.
WARNING!
OptiCare X integrated mattress system is compatible only with Multicare X bed. The OptiCare X integrated
mattress system can only be used when installed on a LINET Multicare X bed frame.
WARNING!
To avoid the risk of electric shock, the Multicare X bed must only be connected to a supply mains with pro-
tective earth.
WARNING!
No modication of OptiCare X integrated mattress system is allowed.
WARNING!
Do not modify OptiCare X integrated mattress system without authorization of the manufacturer.
WARNING!
If OptiCare X integrated mattress system is modied, appropriate inspection and testing must be conducted to
ensure continued safe use of the equipment.
WARNING!
An additional multiple socket-outlet or extension cord shall not be connected to the medical electrical system
of the OptiCare X integrated mattress system with Multicare X bed.
WARNING!
OptiCare X integrated mattress system must be used exclusively by or under supervision of trained and quali-
ed nursing personnel!
WARNING!
Sta expert assessment is needed to consider all individual cases of contraindications!
► Certain bed positions are not suitable for specic diagnosis/medical conditions. Fowler position is not
suitable for spinal cord injuries! Trendelenburg position is not suitable for patients with higher intracranial pre-
ssure!

D9U003VSX-0101_00
13
OptiCare X for Multicare X
WARNING!
Length adjustment of the Multicare X bed must be proportional to the height of patient and to the placement of
the OptiCare X integrated mattress system!
► Risk of trapping or squeezing because of patient´s body constitution disproportionate to the size of
mattress support platform!
WARNING!
During specic investigations or treatments the signicant risks of reciprocal interference posed by OptiCare
X integrated mattress system with Multicare X bed may occur.
WARNING!
Any serious incident that has occurred in relation to the device (OptiCare X integrated mattress system)
should be reported to the manufacturer and the competent authority of the Member State in which the user
and/or patient is established!
WARNING!
Only authorised and trained person using the tool is allowed to change fuses and power supplies of the Opti-
Care X integrated mattress system!
WARNING!
This medical device (OptiCare X integrated mattress system) is not intended for oxygen enriched environment!
WARNING!
This medical device (OptiCare X integrated mattress system) is not intended for use with ammable substan-
ces!
WARNING!
This medical device (OptiCare X integrated mattress system) is not portable medical electrical equipment!

D9U003VSX-0101_00
14
OptiCare X for Multicare X
Additional Instructions for correct use:
► Follow the instructions for use carefully.
► Ensure any user has read and understood the instructions for use completely before operating the product.
► Use OptiCare X integrated mattress system exclusively as specied in the instructions for use and in perfect working
order.
► If necessary, check the OptiCare X functions daily or at each shift change.
► Use the Multicare X bed exclusively with the correct mains supply.
► Ensure that the OptiCare X integrated mattress system is operated exclusively by qualied personnel who have been
trained according to the instructions for use.
► Ensure OptiCare X integrated mattress system is operated by qualified personnel trained in using the Multicare X bed
in accordance with the instructions for use by manufacturer or by person approved by the manufacturer, eventually by authorized
representative or by person approved by the authorized representative.
► Ensure that the patient (health permitting) has been informed about the operation of the OptiCare X integrated mattress
system and all applicable safety instructions.
► Contact service department of the manufacturer immediately to let it replace any damaged parts by the original spare
parts.
► Ensure that maintenance and installation are performed exclusively by qualied personnel who have been trained by the
manufacturer.
► During unavoidable excess loads (e. g. CPR), adjust bed mattress support platform with OptiCare X integrated mattress
system to the lowest position.
► Ensure that only one adult patient lies on the OptiCare X mattress at any time.
► To avoid injury or crushing, take extra caution when operating any moving parts of the Multicare X bed.
► When using lifting poles or infusion stands, ensure that OptiCare X integrated mattress system will not be
damaged when you move or adjust Multicare X bed.
► Keep the Mattress support platform with OptiCare X integrated mattress system in the lowest position at any time when
the healthcare personnel are not treating the patient in order to prevent the patient from falling or injuries.
► Ensure that siderails of Multicare X bed are operated exclusively by healthcare personnel.
► Never handle the mains plug of Multicare X bed with wet hands.
► Disconnect Multicare X bed from the mains exclusively by pulling the mains plug.
► Disconnect Outlet Power cable from the mains exclusively by pulling the mains plug.
► When pulling the mains plug, always hold the plug, not the cable.
► Improper handling of mains cable can cause an electric shock hazard, other serious injuries or damage to OptiCare X
mattress system.
► Ensure that the stipulated duty cycle of Multicare X bed is not exceeded.
► To prevent failures, use exclusively the manufacturer’s original accessories.
► Ensure that the stipulated safe working load is not exceeded.
► If the patient‘s condition could lead to an entrapment, leave the mattress support platform with OptiCare X integrated
mattress system in the at position whilst unattended.
► Do not exceed the maximum patient weight limit of the Multicare X and of the OptiCare X integrated mattress system at
the same time.
► Do not use the SCU near ammable gases. (This does not apply to oxygen cylinders.)
► Do not hang anything on any cable.
► Never use OptiCare X integrated mattress system near radiators or other heat sources.
► After each emergency situation always check if any of the Multicare X controllers (controllers in siderails, handset or Atten-
dant Control Panel) is not involuntarily pressed by the bed accessories or by the OptiCare X integrated mattress.
► To avoid unintended activation of moving parts during any use of the bed always check that none of the control elements
of the Multicare X bed is pressed by persons, by OptiCare X integrated mattress or by other objects.
► Never cover the SCU while in use.
► Never cover the lter of SCU while in use.

D9U003VSX-0101_00
15
3 Intended use (OptiCare X)
The intended use is to prevent and support treatment of pressure injuries.
OptiCare X integrated mattress system is compatible only with Multicare X bed.
3.1 User population
► Caregivers (nurses, doctors)
► Technical Personnel
► Transport Personnel
► Cleaning Personnel
► Adult patients (weight >= 40 kg, height >= 146 cm, BMI >= 17) at moderate risk levels in the intensive care (Application
Environment 1 and 2, as in IEC 60601-2-52)
► Patients with any stage/category of pressure ulcers
3.2 Contraindications
OptiCare X integrated mattress system is contraindicated for patients:
► with cervical traction
► or unstable spinal fractures, spinal cord injury, fractures at risk of complication by a moving surface
► or trauma patients where spinal injuries have not been excluded or cleared
3.3 Operator
► Caregiver

D9U003VSX-0101_00
16
4 Product Description (OptiCare X)
1
2
6
4
7
8
3
5
1. Cover
2. Comfort Layer
3. Air Cell Sets
4. Plastazote Foam Base
5. Foam Base
6. CPR Valve
7. Base Cover
8. Heel Section
Fig. OptiCare X Mattress Description
HEAD END

D9U003VSX-0101_00
17
Fig. Structure of the Air Cell Sets (top view) 1. Area A (WHITE CELLS)
2. Area B (GREY CELLS)
3. Area S (BLUE CELLS)
1
1
2
3
3
2
1

D9U003VSX-0101_00
18
Fig. Fixation of Comfort Layer to the cells (Fixation toggles)
HEAD END
4.1 Mattress Structure
The OptiCare X mattress consists of 4 sections that are held together by 6 quick release xation toggles. The 3 sections include
cover, comfort layer, air cell set and foam base which supports the leg section and side formers. Within the central cut-out of the
foam base is a 10 mm high density foam sheet to protect the patient if the mattress is deated. Air cell set is divided into Area A and
Area B. A two-part cover (1) made of water resistent vapour permeable material encloses the mattress. Beneath the cover and on
the top of the upper air layer is a removable polyester comfort layer (2). The 2 air layers consist of 10 separate air modules for easy
and cost eective replacement in case of user damage. 7 of these air modules are connected together to form the Constant Low
Pressure air mattress, while the other 2 act as air manifolds for the MICROCLIMATE Management (MCM) function. The mattress
has a 7 degree heel slope to help further o-loading of pressure in the vulnerable heel area.
4.2 Cover
The top part of the cover consists of highly moisture- and vapour-permeable (MVP) two-way stretch material which forms an inte-
gral part of the MICROCLIMATE Management (MCM) function. The cover top is equipped with a full 360-degree zip to allow easy
removal for cleaning or replacement. The zip is covered by a waterproof ap to protect the mattress against uid ingress.
The cover base is made from water-impermeable high-strength non-stretch material that is suitable for any demanding environ-
ment. Additional quick-release straps prevent the mattress from shifting if the head board or foot board is removed. Optional ZO-
NED Cover is characterized by the middle slippery zone on its surface.
4.3 Bottom Deck
The bottom air layer is enclosed by a foam base fully contained within a removable waterproof cover. This provides support for the
patient when entering or exiting the bed. The angled sides of the foam base are designed to t securely into the shaped sides of the
Multicare X patient platform to prevent any movement of the mattress when the patient is getting into or out of the bed.
4.4 Heel Section
The heel section is made up of 2 foam in air cells each with a custom designed internal foam shape that allows the 2 cells to collap-
se back into a reduced shape when pressed in by the foot board of the bedframe. This reduces the length of the mattress by 190
mm when compressed. The heel cells will self inate when the bed is lengthened.
4.5 Safety Straps
The sides of the foam base fit the sides of the Multicare X mattress support platform to prevent the mattress from shifting when the
patient is getting into or out of bed.
The mattress is equipped with additional quick-release straps to prevent the mattress from shifting if the head or foot board is remo-
ved. These straps are located on head end and foot end of the bed.
To x the strap:
► Loop black strap around metal bed frame and feed it back through the plastic clip.
To release the strap:
► Pull loose end of strap upward to release clip.

D9U003VSX-0101_00
19
Fig. Base Cover Description
1
3
1
2 2
2 2
1
HEAD END
1. Safety Straps (to fix mattress on the Matress Platform)
2. Transport Handles
3. Aip Pipes
4.6 Transport Handles
WARNING!
Material damage and risk of injury due to incorrect use!
► Transport the mattress using transport handles without patient on it!
Transport handles are intended for transport of the mattress only.
4.7 SCU (System Control Unit)
The SCU (System Control Unit) is installed under the leg section of the bed frame. It is possible to have the Multicare X bed
delivered with the SCU factory-tted, or to have it retrotted by approved service personnel. OptiCare X ready Multicare X bed is
equipped with a dedicated power outlet for the SCU at the auxiliary power distribution point. The SCU is operated via the Integrated
Mattress Screen on the Multiboard X LCD touchscreen. There is no ON/OFF switch on SCU. The SCU is equipped with a compre-
hensive alarm system which detects any problems with the system performance.
The alarm system
► Gives audible and visual alarms via the Multiboard X if a problem requires immediate action.
► Stores information for the service personnel to review later.
4.7.1 FIRMWARE
The system control unit includes rmware that can be updated only by an authorised service technician.
This rmware is protected against unauthorised access by mechanical housing (tool is needed to access) and by exclusive compa-
tibility with an authorised software tool and specic cable.

D9U003VSX-0101_00
20
5 Technical Specication (OptiCare X)
All technical data are rated data and are subject to construction and manufacturing tolerances.
WARNING!
If Multicare X bed is used with OptiCare X integrated mattress system, respect values of mechanical and elect-
rical specications which can harm none of them!
5.1 Mechanical Specications
Parameter Value
External dimensions of Inated Mattress (length x width x height) 214 cm x 87 cm x23 cm
Length of the Integrated Mattress Extension 19 cm
Dimensions of the X-ray Pocket (length x width) 90 cm x92 cm
External dimensions of SCU 36 cm x 22 cm x10 cm
Weight of Inated Mattress 14 kg (31 lbs)
Weight of SCU 6 kg (13.1 lbs)
Ination time after storage max. 10 min
CPR deation time (depending on patient weight, chosen mode - optimization
or maximum internal pressure - and on type of CPR - electric or manual)
max. 30 s
Remain Inated in Transport Mode 12 hours (whem starting from Maximum
Inate Mode)
Sound Pressure Level max. 46 dBA (normal operation without
any sounding alert signal)
Maximum Patient Weight 250 kg (551 lbs)
Minimum Mattress Load 40 kg
Maximum Washing Temperature of the mattress cover ELITE (MIC200) 71°C
Maximum Washing Temperature of the mattress cover ENDURANCE (SIOEN
RP9774-2)
71°C
Maximum Washing Temperature of the mattress cover ZONED (DARTEX) 55°C
Maximum Drying Temperature of the mattress cover ELITE (MIC200) 55°C
Maximum Drying Temperature of the mattress cover ENDURANCE (SIOEN
RP9774-2)
55°C
Maximum Drying Temperature of the mattress cover ZONED (DARTEX) 55°C
Fire Resistance of the Cover according to BS7175 - ignition source 5
Fire Resistance of the Top Cover according to 16 CFR 1632
Fire Resistance of the whole mattress according to BS7177 - ignition source 5,
16 CFR 1632
5.2 Electrical Specications
Parameter Value
Input Voltage, Frequency:
EU version
USA version
Brazilian version
220-240 V AC, 50/60 Hz
100-127 V AC, 50/60 Hz
220 V AC, 60 Hz
Maximum Power Input max. 40 VA (when operating from mains supply)
Ingress Protection (EN 60529) IPX4
Protection Class Class I with Applied Parts Type B
Electrical Safety in conformity with EN 60601-1
SCU Fuse
220-240 V AC version
100-127 V AC version
2 x T0,5AH Anti-surge Fuse
2 x T1AH Anti-surge Fuse
Table of contents
Other LINET Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

Regency
Regency LWMS3015 Assembly instructions

Furniture of America
Furniture of America CM7751C Assembly instructions

Safavieh Furniture
Safavieh Furniture Estella CNS5731 manual

PLACES OF STYLE
PLACES OF STYLE Ovalfuss Assembly instruction

Trasman
Trasman 1138 Bo1 Assembly manual

Costway
Costway JV10856 manual